Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 8 de 8
Filtrar
1.
Am Heart J ; 177: 102-11, 2016 07.
Artigo em Inglês | MEDLINE | ID: mdl-27297855

RESUMO

Management of patients with acute chest pain remains challenging. Cardiac biomarker testing reduces the likelihood of erroneously discharging patients with acute myocardial infarction (AMI). Despite normal contemporary troponins, physicians have still been reluctant to discharge patients without additional testing. Nowadays, the extremely high negative predictive value of current high-sensitivity cardiac troponin (hs-cTn) assays challenges this need. However, the decreased specificity of hs-cTn assays to diagnose AMI poses a new problem as noncoronary diseases (eg, pulmonary embolism, myocarditis, cardiomyopathies, hypertension, renal failure, etc) may also cause elevated hs-cTn levels. Subjecting patients with noncoronary diseases to unnecessary pharmacological therapy or invasive procedures must be prevented. Attempts to improve the positive predictive value to diagnose AMI by defining higher initial cutoff values or dynamic changes over time inherently lower the sensitivity of troponin assays. In this review, we anticipate a potential changing role of noninvasive imaging from ruling out myocardial disease when troponin values are normal toward characterizing myocardial disease when hs-cTn values are (mildly) abnormal.


Assuntos
Dor no Peito/diagnóstico por imagem , Doença da Artéria Coronariana/diagnóstico por imagem , Infarto do Miocárdio/diagnóstico por imagem , Troponina/sangue , Cardiomiopatias/sangue , Cardiomiopatias/complicações , Cardiomiopatias/diagnóstico por imagem , Dor no Peito/sangue , Dor no Peito/etiologia , Angiografia por Tomografia Computadorizada , Angiografia Coronária , Doença da Artéria Coronariana/sangue , Doença da Artéria Coronariana/complicações , Diagnóstico Diferencial , Ecocardiografia sob Estresse , Teste de Esforço , Humanos , Imageamento por Ressonância Magnética , Infarto do Miocárdio/sangue , Infarto do Miocárdio/complicações , Imagem de Perfusão do Miocárdio , Miocardite/sangue , Miocardite/complicações , Miocardite/diagnóstico por imagem , Embolia Pulmonar/sangue , Embolia Pulmonar/complicações , Embolia Pulmonar/diagnóstico por imagem , Sensibilidade e Especificidade , Tomografia Computadorizada de Emissão de Fóton Único
2.
J Cardiovasc Magn Reson ; 15: 5, 2013 Jan 16.
Artigo em Inglês | MEDLINE | ID: mdl-23324388

RESUMO

BACKGROUND: Although echocardiography is used as a first line imaging modality, its accuracy to detect acute and chronic myocardial infarction (MI) in relation to infarct characteristics as assessed with late gadolinium enhancement cardiovascular magnetic resonance (LGE-CMR) is not well described. METHODS: One-hundred-forty-one echocardiograms performed in 88 first acute ST-elevation MI (STEMI) patients, 2 (IQR1-4) days (n = 61) and 102 (IQR92-112) days post-MI (n = 80), were pooled with echocardiograms of 36 healthy controls. 61 acute and 80 chronic echocardiograms were available for analysis (53 patients had both acute and chronic echocardiograms). Two experienced echocardiographers, blinded to clinical and CMR data, randomly evaluated all 177 echocardiograms for segmental wall motion abnormalities (SWMA). This was compared with LGE-CMR determined infarct characteristics, performed 104 ± 11 days post-MI. Enhancement on LGE-CMR matched the infarct-related artery territory in all patients (LAD 31%, LCx 12% and RCA 57%). RESULTS: The sensitivity of echocardiography to detect acute MI was 78.7% and 61.3% for chronic MI; specificity was 80.6%. Undetected MI were smaller, less transmural, and less extensive (6% [IQR3-12] vs. 15% [IQR9-24], 50 ± 14% vs. 61 ± 15%, 7 ± 3 vs. 9 ± 3 segments, p < 0.001 for all) and associated with higher left ventricular ejection fraction (LVEF) and non-anterior location as compared to detected MI (58 ± 5% vs. 46 ± 7%, p < 0.001 and 82% vs. 63%, p = 0.03). After multivariate analysis, LVEF and infarct size were the strongest independent predictors of detecting chronic MI (OR 0.78 [95%CI 0.68-0.88], p < 0.001 and OR 1.22 [95%CI0.99-1.51], p = 0.06, respectively). Increasing infarct transmurality was associated with increasing SWMA (p < 0.001). CONCLUSIONS: In patients presenting with STEMI, and thus a high likelihood of SWMA, the sensitivity of echocardiography to detect SWMA was higher in the acute than the chronic phase. Undetected MI were smaller, less extensive and less transmural, and associated with non-anterior localization and higher LVEF. Further work is needed to assess the diagnostic accuracy in patients with non-STEMI.


Assuntos
Ecocardiografia , Imagem Cinética por Ressonância Magnética , Infarto do Miocárdio/diagnóstico , Miocárdio/patologia , Adulto , Idoso , Distribuição de Qui-Quadrado , Doença Crônica , Meios de Contraste , Feminino , Gadolínio DTPA , Humanos , Modelos Logísticos , Masculino , Pessoa de Meia-Idade , Análise Multivariada , Contração Miocárdica , Infarto do Miocárdio/diagnóstico por imagem , Infarto do Miocárdio/patologia , Infarto do Miocárdio/fisiopatologia , Variações Dependentes do Observador , Razão de Chances , Valor Preditivo dos Testes , Reprodutibilidade dos Testes , Estudos Retrospectivos , Volume Sistólico , Fatores de Tempo , Função Ventricular Esquerda
3.
Eur Heart J Cardiovasc Imaging ; 18(9): 980-987, 2017 Sep 01.
Artigo em Inglês | MEDLINE | ID: mdl-28329376

RESUMO

AIMS: To compare the prognostic value of negative non-invasive cardiac investigations (coronary computed tomographic angiography [CCTA], cardiovascular magnetic resonance [CMR], exercise electrocardiographic testing [EET], positron emission tomography [PET], stress-echocardiography [SE], and single-photon emission tomography [SPECT]) in patients with suspected or known coronary artery disease (CAD) and to explore the effect of adjustment for population event risk and presence of CAD. METHODS AND RESULTS: MEDLINE/PubMed database, EMBASE and Cochrane Library were searched from January-1990 to April-2015 for studies reporting annual event rates (AER) of myocardial infarction (MI) and cardiac death. Pooled estimates of AERs were calculated using a DerSimonian and Laird random-effects model. Multivariable linear meta-regression analysis was performed to compare the AER after a negative test result between modalities and to adjust for population event risk and proportion of patients with CAD. In 165 studies (122,721 patients), pooled AERs after negative test results differed significantly between modalities ranging from 0.32% for CCTA to 1.66% for SE, P < 0.001. However, the AER after a negative test result was positively correlated (r = 0.726, P < 0.001) with population event risk. Adjusting for population event risk and proportion of patients with CAD resulted in more similar event rates after a negative test result. CONCLUSION: This meta-analysis is the first study comparing the prognostic value of all available non-invasive cardiac investigations. Outcome differences between modalities after a negative test result are profoundly influenced by large variations in population event risk and a negative test result for all modalities conveys an excellent prognosis for patients with suspected or known CAD.


Assuntos
Técnicas de Imagem Cardíaca/métodos , Doença da Artéria Coronariana/diagnóstico por imagem , Idoso , Doenças Assintomáticas , Angiografia por Tomografia Computadorizada/métodos , Angiografia Coronária/métodos , Doença da Artéria Coronariana/complicações , Doença da Artéria Coronariana/mortalidade , Progressão da Doença , Ecocardiografia sob Estresse/métodos , Feminino , Humanos , Imagem Cinética por Ressonância Magnética/métodos , Masculino , Pessoa de Meia-Idade , Infarto do Miocárdio/diagnóstico por imagem , Infarto do Miocárdio/mortalidade , Tomografia por Emissão de Pósitrons/métodos , Prognóstico , Índice de Gravidade de Doença , Tomografia Computadorizada de Emissão de Fóton Único/métodos
4.
Int J Cardiol ; 248: 433-439, 2017 Dec 01.
Artigo em Inglês | MEDLINE | ID: mdl-28733074

RESUMO

BACKGROUND: We aimed to evaluate the microvascular function in patients with microvascular angina (MVA) by assessing 1) the endothelial glycocalyx barrier properties using sublingual microscopy, and 2) the myocardial perfusion reserve using cardiovascular magnetic resonance (CMR) imaging. METHODS: Sublingual microscopy was performed in 13 MVA patients (angina pectoris, ST-depression on treadmill testing, normal coronary angiogram) and compared with 2 control groups of 13 volunteers and 14 patients with known obstructive coronary artery disease (CAD). To test the glycocalyx-mediated microvascular responsiveness, the erythrocyte perfused boundary region (PBR) was assessed at baseline and after nitroglycerin challenge. RESULTS: The baseline PBR of MVA patients was similar to controls with CAD (p=0.72), and larger than in volunteers (p=0.02). Only the volunteers demonstrated a significant increase in PBR after nitroglycerin (p=0.03). In the 13 MVA patients, adenosine stress CMR perfusion imaging was performed. Although a significant increase in myocardial perfusion was observed in both the subendocardium and subepicardium during stress, the subendocardial perfusion reserve was significantly lower (p=0.02). The PBR responsiveness of the sublingual microvasculature showed a strong correlation with the transmural myocardial perfusion reserve (r=0.86, p<0.001). CONCLUSIONS: Patients with MVA can be characterized by microvascular glycocalyx dysfunction using sublingual microscopy. The strong correlation between sublingual PBR responsiveness and myocardial perfusion reserve suggests that the glycocalyx may play an important role in the regulation of microvascular volume for myocardial perfusion and supports the concept of impaired glycocalyx barrier properties in MVA.


Assuntos
Circulação Coronária/fisiologia , Angina Microvascular/diagnóstico por imagem , Microvasos/diagnóstico por imagem , Idoso , Feminino , Humanos , Masculino , Angina Microvascular/fisiopatologia , Microvasos/fisiopatologia , Pessoa de Meia-Idade , Soalho Bucal/irrigação sanguínea , Soalho Bucal/diagnóstico por imagem , Imagem de Perfusão do Miocárdio/métodos , Estudos Prospectivos
6.
Am J Cardiol ; 112(8): 1069-74, 2013 Oct 15.
Artigo em Inglês | MEDLINE | ID: mdl-23827406

RESUMO

Although electrocardiography is frequently used as an initial test to detect or rule out previous myocardial infarction (MI), the diagnostic performance of commonly used electrocardiographic scoring systems is not well described. We aimed to determine the diagnostic accuracy of (1) the Universal Definition, (2) Minnesota ECG Code (MC), (3) Selvester QRS Score, and (4) assessment by cardiologists using late gadolinium enhancement cardiovascular magnetic resonance imaging as the reference standard. Additionally, the effect of electrocardiographic patterns and infarct characteristics on detecting previous MI was evaluated. The 3-month follow-up electrocardiograms of 78 patients with first-time reperfused ST elevation MI were pooled with electrocardiograms of 36 healthy controls. All 114 electrocardiograms were randomly analyzed, blinded to clinical and LGE-CMR data. The sensitivity of the Universal Definition, MC, Selvester QRS Score, and cardiologists to detect previous MI was 33%, 79%, 90%, and 67%, respectively; specificity 97%, 72%, 31%, and 89%, respectively; diagnostic accuracy 54%, 77%, 71%, and 74%, respectively. Probability of detecting MI by cardiologists increased with an increasing number (odds ratio [OR] 2.00, 95% confidence interval [CI] 1.30 to 3.09), width (OR 1.02, 95% CI 1.01 to 1.03), and depth (OR 1.16, 95% CI 1.07 to 1.27) of Q waves as well as increasing infarct size (OR 1.15, 95% CI 1.06 to 1.25) and transmurality (OR 1.05, 95% CI 1.01 to 1.08; p <0.05 for all). The time-consuming MC and rapid visual assessment by cardiologists achieved the best and similar diagnostic accuracies to detect previous MI. The diagnostic performance of all 4 electrocardiographic scoring systems was modest and related to the number, depth, and width of Q waves as well as increasing infarct size and transmurality. In conclusion, the exclusion of a previous MI based solely on electrocardiographic findings should be done with caution. Future studies are needed to define which patients should be referred to additional diagnostic testing.


Assuntos
Eletrocardiografia , Imagem Cinética por Ressonância Magnética/métodos , Infarto do Miocárdio/diagnóstico , Miocárdio/patologia , Adulto , Diagnóstico Diferencial , Feminino , Seguimentos , Humanos , Masculino , Pessoa de Meia-Idade , Infarto do Miocárdio/fisiopatologia , Estudos Prospectivos , Curva ROC , Reprodutibilidade dos Testes , Índice de Gravidade de Doença
7.
J Am Coll Cardiol ; 59(19): 1719-28, 2012 May 08.
Artigo em Inglês | MEDLINE | ID: mdl-22554604

RESUMO

OBJECTIVES: This study aimed to determine the diagnostic accuracy of the 3 most commonly used noninvasive myocardial perfusion imaging modalities, single-photon emission computed tomography (SPECT), cardiac magnetic resonance (CMR), and positron emission tomography (PET) perfusion imaging for the diagnosis of obstructive coronary artery disease (CAD). Additionally, the effect of test and study characteristics was explored. BACKGROUND: Accurate detection of obstructive CAD is important for effective therapy. Noninvasive myocardial perfusion imaging is increasingly being applied to gauge the severity of CAD. METHODS: Studies published between 1990 and 2010 identified by PubMed search and citation tracking were examined. A study was included if a perfusion imaging modality was used as a diagnostic test for the detection of obstructive CAD and coronary angiography as the reference standard (≥50% diameter stenosis). RESULTS: Of the 3,635 citations, 166 articles (n = 17,901) met the inclusion criteria: 114 SPECT, 37 CMR, and 15 PET articles. There were not enough publications on other perfusion techniques such as perfusion echocardiography and computed tomography to include these modalities into the study. The patient-based analysis per imaging modality demonstrated a pooled sensitivity of 88% (95% confidence interval [CI]: 88% to 89%), 89% (95% CI: 88% to 91%), and 84% (95% CI: 81% to 87%) for SPECT, CMR, and PET, respectively; with a pooled specificity of 61% (95% CI: 59% to 62%), 76% (95% CI: 73% to 78%), and 81% (95% CI: 74% to 87%). This resulted in a pooled diagnostic odds ratio (DOR) of 15.31 (95% CI: 12.66 to 18.52; I(2) 63.6%), 26.42 (95% CI: 17.69 to 39.47; I(2) 58.3%), and 36.47 (95% CI: 21.48 to 61.92; I(2) 0%). Most of the evaluated test and study characteristics did not affect the ranking of diagnostic performances. CONCLUSIONS: SPECT, CMR, and PET all yielded a high sensitivity, while a broad range of specificity was observed. SPECT is widely available and most extensively validated; PET achieved the highest diagnostic performance; CMR may provide an alternative without ionizing radiation and a similar diagnostic accuracy as PET. We suggest that referring physicians consider these findings in the context of local expertise and infrastructure.


Assuntos
Doença da Artéria Coronariana/metabolismo , Imageamento por Ressonância Magnética/métodos , Imagem de Perfusão do Miocárdio/métodos , Miocárdio/patologia , Tomografia por Emissão de Pósitrons/métodos , Tomografia Computadorizada de Emissão de Fóton Único/métodos , Idoso , Angiografia Coronária/métodos , Doença da Artéria Coronariana/diagnóstico , Doença da Artéria Coronariana/epidemiologia , Humanos , Pessoa de Meia-Idade , Perfusão , Prevalência , Padrões de Referência , Sensibilidade e Especificidade
8.
PLoS One ; 6(10): e26567, 2011.
Artigo em Inglês | MEDLINE | ID: mdl-22028910

RESUMO

BACKGROUND: The aim of this study was to explore the feasibility and reproducibility of a time-efficient coronary vessel wall measurement approach using an improved motion-sensitized driven equilibrium (iMSDE) pulse sequence. METHODOLOGY: In this study, the iMSDE pulse sequence was first optimized and then applied on a group of healthy volunteers (N = 10) to evaluate its feasibility of vessel wall visualization. The same technique was also applied on a separate group of volunteers (N = 19) for a reproducibility study by scanning the same subject in two separate sessions. The iMSDE sequence was found to provide good coronary vessel wall delineation. It was also found to provide reproducible coronary vessel wall diameter and thickness measurements in both proximal and middle segments of the right coronary artery. CONCLUSION: The feasibility and reproducibility of iMSDE based coronary vessel wall imaging were demonstrated for the first time, paving the way for further testing in a clinical environment for fast and accurate coronary artery disease detection.


Assuntos
Vasos Coronários/anatomia & histologia , Processamento de Imagem Assistida por Computador/métodos , Imageamento por Ressonância Magnética/métodos , Movimento , Adulto , Idoso , Estudos de Viabilidade , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Reprodutibilidade dos Testes , Fatores de Tempo
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA