Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros

Base de dados
Tipo de documento
Ano de publicação
Intervalo de ano de publicação
1.
Neuroradiology ; 51(5): 319-26, 2009 May.
Artigo em Inglês | MEDLINE | ID: mdl-19219600

RESUMO

PURPOSE: This study aimed to retrospectively analyze a series of patients with complex posterior circulation stenosis who underwent stent-assisted angioplasty to evaluate the feasibility of the procedure and summarize the experience with regard to complications. METHODS: A total of 16 consecutive patients with 27 complex posterior circulation artery stenoses refractory to medical therapy were enrolled. Technical success rate, periprocedural complication, and long-term follow-up result were evaluated. RESULTS: The study population included 16 patients with 27 lesions. A total of 36 stents were successfully implanted. The technical success rate was 100%, and the overall periprocedural complication rate was 12.5% (2/16). During a median of 25.5 months of follow-up, three patients presented recurrent transient ischemic attacks, which were confirmed had restenosis more than 50% by control angiography or transcranial Doppler. CONCLUSIONS: Stent-assisted angioplasty is a feasible treatment method for complex posterior circulation artery stenosis. However, it appears to be associated with a relatively high periprocedural complication rate. Therefore, strict periprocedural management to reduce mortality and morbidity is needed.


Assuntos
Arteriopatias Oclusivas/diagnóstico , Arteriopatias Oclusivas/cirurgia , Prótese Vascular , Cateterismo/instrumentação , Doenças Arteriais Cerebrais/diagnóstico , Doenças Arteriais Cerebrais/cirurgia , Stents , Desenho de Equipamento , Estudos de Viabilidade , Humanos , Projetos Piloto , Resultado do Tratamento
2.
Zhong Nan Da Xue Xue Bao Yi Xue Ban ; 33(8): 751-4, 2008 Aug.
Artigo em Zh | MEDLINE | ID: mdl-18772519

RESUMO

OBJECTIVE: To investigate the relationship between the clinical features of carotid transient ischemic attacks (TIA) and the intracranial or extracranial angiostenosis. METHODS: Location and degree of stenosis of involved arteries were examined by the digital subtraction angiography in 52 patients with carotid TIA. RESULTS: Intracranial or extracranial vascular lesions of different degrees were revealed in 45 patients (86.5%), and 29 out of 45 (64.4%) had more than one site. Severe stenosis and occlusion occurred more frequently in TIA patients with short duration (less than 1 hour) and multiple attacks (more than twice). CONCLUSION: Most patients with TIA of carotid systems have stenosis in intracranial or extracranial arteries. TIA with short duration and multiple attacks always accompany with severe stenosis or occlusion in intracranial or extracranial arteries. Digital subtraction angiography helps to identify the vascular etiology of TIA and provides the instruction of therapeutic regimen.


Assuntos
Angiografia Digital , Estenose das Carótidas/diagnóstico por imagem , Transtornos Cerebrovasculares/diagnóstico por imagem , Ataque Isquêmico Transitório/diagnóstico por imagem , Adulto , Idoso , Estenose das Carótidas/complicações , Estenose das Carótidas/patologia , Angiografia Cerebral , Transtornos Cerebrovasculares/complicações , Transtornos Cerebrovasculares/patologia , Feminino , Humanos , Ataque Isquêmico Transitório/patologia , Masculino , Pessoa de Meia-Idade
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA