RESUMO
The liver differs from other organs in that two vascular systems deliver its blood - the hepatic artery and the portal vein. However, how the two systems interact is not fully understood. We therefore studied the microvascular geometry of rat liver hepatic artery and portal vein injected with the contrast polymer Microfil(®). Intact isolated rat livers were imaged by micro-CT and anatomic evidence for hepatic arteriolo-portal venular shunts occurring between hepatic artery and portal vein branches was found. Simulations were performed to rule out the possibility of the observed shunts being artifacts resulting from image blurring. In addition, in the case of specimens where only the portal vein was injected, only the portal vein was opacified, whereas in hepatic artery injections, both the hepatic artery and portal vein were opacified. We conclude that mixing of the hepatic artery and portal vein blood can occur proximal to the sinusoidal level, and that the hepatic arteriolo-portal venular shunts may function as a one-way valve-like mechanism, allowing flow only from the hepatic artery to the portal vein (and not the other way around).
Assuntos
Artéria Hepática/anatomia & histologia , Fígado/irrigação sanguínea , Veia Porta/anatomia & histologia , Animais , Imageamento Tridimensional , Ratos , Microtomografia por Raio-XRESUMO
PURPOSE: It has been shown that coherently scattered x rays can be used to discriminate and identify specific components in a mixture of low atomic weight materials. The authors demonstrated a new method of doing coherently scattered x-ray tomography with a thin sheet of x ray. METHODS: A collimated x-ray fan-beam, a parallel polycapillary collimator, and a phantom consisting of several biocompatible materials of low attenuation-based contrast were used to investigate the feasibility of the method. Because of the particular experimental setup, only the phantom translation perpendicular to the x-ray beam is needed and, thus, there is no need of Radon-type tomographic reconstruction, except for the correction of the attenuation to the primary and scattered x rays, which was performed by using a conventional attenuation-based tomographic image data set. The coherent scatter image contrast changes with momentum transfer among component materials in the specimen were investigated with multiple x-ray sources with narrow bandwidth spectra generated with anode and filter combinations of Cu/Ni (8 keV), Mo/Zr (18 keV), and Ag/Pd (22 keV) and at multiple scatter angles by orienting the detector and polycapillary collimator at different angles to the illuminating x ray. RESULTS: The contrast among different materials changes with the x-ray source energy and the angle at which the image was measured. The coherent scatter profiles obtained from the coherent scatter images are consistent with the published results. CONCLUSIONS: This method can be used to directly generate the three-dimensional coherent scatter images of small animal, biopsies, or other small objects with low atomic weight biological or similar synthetic materials with low attenuation contrast. With equipment optimized, submillimeter spatial resolution may be achieved.
Assuntos
Imageamento Tridimensional/métodos , Espalhamento de Radiação , Microtomografia por Raio-X/métodos , Imageamento Tridimensional/instrumentação , Microtomografia por Raio-X/instrumentaçãoRESUMO
OBJECTIVE: This study is motivated by the possibility of using computed tomography (CT) to detect early coronary atherosclerosis by the increased CT values within the arterial wall resulting from vasa vasorum proliferation. METHODS: Coronary arteries (n = 5) with early atherosclerotic changes were injected with Microfil and scanned (micro-CT). Noise was added to the CT projection data sets (to represent the radiation exposure of current clinical CT scanners) and then reconstructed to generate 3-dimensional images at different voxel sizes. RESULTS: Higher CT values were detected because of contrast agent in vasa vasorum if voxel size was less than (150 microm)(3). Contrast in the main lumen increased the CT values dramatically at voxels greater than (100 microm)(3), whereas CT values of the same specimen without contrast in the main lumen remained constant. CONCLUSIONS: Voxel sizes less than (200 microm)(3) are needed to quantitate arterial wall opacification due to vasa vasorum proliferation.
Assuntos
Angiografia Coronária/métodos , Vasos Coronários/anatomia & histologia , Tomografia Computadorizada por Raios X/métodos , Vasa Vasorum/anatomia & histologia , Cadáver , Humanos , Imageamento Tridimensional , Técnicas In Vitro , Interpretação de Imagem Radiográfica Assistida por Computador , Análise de Regressão , Vasa Vasorum/diagnóstico por imagem , Microtomografia por Raio-XRESUMO
We assess the performance of a cadmium zinc telluride (CZT)-based Medipix3RX energy-resolving and photon-counting x-ray detector as a candidate for spectral microcomputed tomography (micro-CT) imaging. It features an array of 128 × 128 , 110 - µ m 2 pixels, each with four simultaneous threshold counters that utilize real-time charge summing. Each pixel's response is assessed by imaging with a range of incident x-ray intensities and detector integration times. Energy-related assessments are made by exposing the detector to the emission from an I-125 radioisotope brachytherapy seed. Long-term stability is assessed by repeating identical exposures over the course of 1 h. The high yield of properly functioning pixels (98.8%), long-term stability (linear regression of whole-chip response over 1 h of acquisitions: y = - 0.0038 x + 2284 ; standard deviation: 3.7 counts), and energy resolution [2.5 keV full-width half-maximum (FWHM) (single pixel), 3.7 keV FWHM (across the full image)] make this device suitable for spectral micro-CT.
RESUMO
OBJECTIVES: To determine if hemorrhage into an arterial wall can be detected in CT images by virtue of the iron content. MATERIALS AND METHODS: Aortas from male apoE(-/-)/LDL(-/-) mice (n = 31) were infused in situ with contrast agent, for micro-CT scanning and histology. Roentgen-opacities within the aortic walls were identified by histology and micro-x-ray fluorescence to be iron or calcium. Dual-energy scanning was performed at 2 energy levels using synchrotron-based micro-CT [(2 microm)(3) voxels, 16 and 20 keV] and 64-slice CT (0.4 x 0.4 x 0.6 mm voxels, 80 and 120 kVp). RESULTS: Opacities were identified as hemorrhage-related clusters of multiple punctate deposits, containing both Fe (0.48 x 10(-12) g/voxel) and Ca (3.18 x 10(-2) g/voxel), or as isolated confluent accumulations of exclusively calcium. Subtraction of the dual-energy CT scans discriminated iron from calcium deposits. CONCLUSION: Detection and quantification of iron deposits in hemorrhaged atherosclerotic lesions is feasible by dual-energy CT imaging.
Assuntos
Doenças da Aorta/diagnóstico por imagem , Apolipoproteínas E/genética , Aterosclerose/diagnóstico por imagem , Hemorragia/diagnóstico por imagem , Lipoproteínas LDL/genética , Tomografia Computadorizada por Raios X/métodos , Animais , Doenças da Aorta/patologia , Aterosclerose/genética , Aterosclerose/patologia , Cálcio/análise , Modelos Animais de Doenças , Hemorragia/patologia , Ferro/análise , Masculino , Camundongos , Camundongos Endogâmicos C57BL , Camundongos Knockout , Técnica de SubtraçãoRESUMO
Changes in arterial wall perfusion are an indicator of early atherosclerosis. This is characterized by an increased spatial density of vasa vasorum (VV), the micro-vessels that supply oxygen and nutrients to the arterial wall. Detection of increased VV during contrast-enhanced computed tomography (CT) imaging is limited due to contamination from blooming effect from the contrast-enhanced lumen. We report the application of an image deconvolution technique using a measured system point-spread function, on CT data obtained from a photon-counting CT system to reduce blooming and to improve the CT number accuracy of arterial wall, which enhances detection of increased VV. A phantom study was performed to assess the accuracy of the deconvolution technique. A porcine model was created with enhanced VV in one carotid artery; the other carotid artery served as a control. CT images at an energy range of 25-120 keV were reconstructed. CT numbers were measured for multiple locations in the carotid walls and for multiple time points, pre and post contrast injection. The mean CT number in the carotid wall was compared between the left (increased VV) and right (control) carotid arteries. Prior to deconvolution, results showed similar mean CT numbers in the left and right carotid wall due to the contamination from blooming effect, limiting the detection of increased VV in the left carotid artery. After deconvolution, the mean CT number difference between the left and right carotid arteries was substantially increased at all the time points, enabling detection of the increased VV in the artery wall.
RESUMO
Changes in arterial wall perfusion mark the onset of atherosclerosis. A characteristic change is the increased spatial density of vasa vasorum (VV), the microvessels in the arterial walls. Measuring this increased VV (IVV) density using contrast-enhanced computed tomography (CT) has had limited success due to blooming effects from contrast media. If the system point-spread function (PSF) is known, then the blooming effect can be modeled as a convolution between the true signal and the PSF. We report the application of image deconvolution to improve the CT number accuracy in the arterial wall of a phantom and in a porcine model of IVV density, both scanned using a whole-body research photon-counting CT scanner. A 3D-printed carotid phantom filled with three concentrations of iodinated contrast material was scanned to assess blooming and its effect on wall CT number accuracy. The results showed a reduction in blooming effects following image deconvolution, and, consequently, a better delineation between lumen and wall was achieved. Results from the animal experiment showed improved CT number difference between the carotid with IVV density and the normal carotid artery after deconvolution, enabling the detection of VV proliferation, which may serve as an early indicator of atherosclerosis.
RESUMO
Early atherosclerosis changes perfusion of the arterial wall due to localized proliferation of the vasa vasorum. When contrast agent passes through the artery, some enters the vasa vasorum and increases radiopacity of the arterial wall. Technical challenges to detecting changes in vasa vasorum density include the thin arterial wall, partial volume averaging at the arterial lumen/wall interface and calcification within the wall. We used a photon-counting spectral CT scanner to study carotid arteries of anesthetized pigs and micro-CT of these arteries to quantify vasa vasorum density. The left carotid artery wall was injected with autologous blood to stimulate vasa vasorum angiogenesis. The scans were performed at 25-120 keV; the tube-current-time product was 550 mAs. A 60 mL bolus of iodine contrast agent was injected into the femoral vein at 5mL/s. Two seconds post injection, an axial scan was acquired at every 3 s over 60 s (i.e., 20 time points). Each time point acquired 28 contiguous transaxial slices with reconstructed voxels 0.16 × 0.16 × 1 mm3. Regions-of-interest in the outer 2/3 of the arterial wall and in the middle 2/3 of the lumen were drawn and their enhancements plotted versus time. Lumenal CT values peaked several seconds after injection and then returned towards baseline. Arterial wall CT values peaked concurrent to the lumen. The peak arterial wall enhancement in the left carotid arterial wall correlated with increased vasa vasorum density observed in micro-CT images of the isolated arteries.
RESUMO
We assessed the performance of a cadmium zinc telluride (CZT)-based Medipix3RX x-ray detector as a candidate for micro-computed tomography (micro-CT) imaging. This technology was developed at CERN for the Large Hadron Collider. It features an array of 128 by 128, 110 micrometer square pixels, each with eight simultaneous threshold counters, five of which utilize real-time charge summing, significantly reducing the charge sharing between contiguous pixels. Pixel response curves were created by imaging a range of x-ray intensities by varying x-ray tube current and by varying the exposure time with fixed x-ray current. Photon energy-related assessments were made by flooding the detector with the tin foil filtered emission of an I-125 radioisotope brachytherapy seed and sweeping the energy threshold of each of the four charge-summed counters of each pixel in 1 keV steps. Long term stability assessments were made by repeating exposures over the course of one hour. The high properly-functioning pixel yield (99%), long term stability (linear regression of whole-chip response over one hour of acquisitions: y = -0.0038x + 2284; standard deviation: 3.7 counts) and energy resolution (2.5 keV FWHM (single pixel), 3.7 keV FWHM across the full image) make this device suitable for spectral micro-CT. The charge summing performance effectively reduced the measurement corruption caused by charge sharing which, when unaccounted for, shifts the photon energy assignment to lower energies, degrading both count and energy accuracy. Effective charge summing greatly improves the potential for calibrated, energy-specific material decomposition and K edge difference imaging approaches.
RESUMO
OBJECTIVES: The purpose of this work was to measure and compare the iodine contrast-to-noise ratio (CNR) between a commercial energy-integrating detector (EID) computed tomography (CT) system and a photon-counting detector (PCD) CT scanner capable of human imaging at clinical dose rates, as well as to determine clinical feasibility using human cadavers. MATERIALS AND METHODS: A research dual-source PCD-CT scanner was used, where the "A" tube/detector subsystem used an EID and the "B" tube/detector subsystem used a PCD. Iodine CNR was measured in 4 anthropomorphic phantoms, simulating 4 patient sizes, at 4 tube potential settings. After biospecimen committee approval, PCD scans were performed on a fresh-frozen human head and a whole-body cadaver using clinical dose rates. Scans were repeated using the EID and identical parameters, and qualitative side-by-side comparisons were performed. RESULTS: For the same photon fluence, phantom measurements demonstrated a mean increase in CNR of 11%, 23%, 31%, 38% for the PCD system, relative to the EID system, at 80, 100, 120, and 140 kV, respectively. Photon-counting detector CT additionally provided energy-selective imaging, where low- and high-energy images reflected the energy dependence of the iodine signal. Photon-counting detector images of cadaveric anatomy demonstrated decreased beam hardening and calcium blooming in the high-energy bin images and increased contrast in the low-energy bins images relative to the EID images. Threshold-based PCD images were qualitatively deemed equivalent in other aspects. CONCLUSIONS: The evaluated research PCD-CT system was capable of clinical levels of image quality at clinical dose rates. It further provided improved CNR relative to state-of-the-art EID-CT. The energy-selective bin images provide further opportunity for dual-energy and multienergy analyses.
Assuntos
Meios de Contraste , Processamento de Imagem Assistida por Computador/métodos , Imagens de Fantasmas , Intensificação de Imagem Radiográfica/métodos , Interpretação de Imagem Radiográfica Assistida por Computador/métodos , Tomografia Computadorizada por Raios X/métodos , Adulto , Idoso , Cadáver , Criança , Feminino , Humanos , Recém-Nascido , Iodo , Ruído , Fótons , Tomografia Computadorizada por Raios X/instrumentaçãoRESUMO
This study evaluated the conventional imaging performance of a research whole-body photon-counting CT system and investigated its feasibility for imaging using clinically realistic levels of x-ray photon flux. This research system was built on the platform of a 2nd generation dual-source CT system: one source coupled to an energy integrating detector (EID) and the other coupled to a photon-counting detector (PCD). Phantom studies were conducted to measure CT number accuracy and uniformity for water, CT number energy dependency for high-Z materials, spatial resolution, noise, and contrast-to-noise ratio. The results from the EID and PCD subsystems were compared. The impact of high photon flux, such as pulse pile-up, was assessed by studying the noise-to-tube-current relationship using a neonate water phantom and high x-ray photon flux. Finally, clinical feasibility of the PCD subsystem was investigated using anthropomorphic phantoms, a cadaveric head, and a whole-body cadaver, which were scanned at dose levels equivalent to or higher than those used clinically. Phantom measurements demonstrated that the PCD subsystem provided comparable image quality to the EID subsystem, except that the PCD subsystem provided slightly better longitudinal spatial resolution and about 25% improvement in contrast-to-noise ratio for iodine. The impact of high photon flux was found to be negligible for the PCD subsystem: only subtle high-flux effects were noticed for tube currents higher than 300 mA in images of the neonate water phantom. Results of the anthropomorphic phantom and cadaver scans demonstrated comparable image quality between the EID and PCD subsystems. There were no noticeable ring, streaking, or cupping/capping artifacts in the PCD images. In addition, the PCD subsystem provided spectral information. Our experiments demonstrated that the research whole-body photon-counting CT system is capable of providing clinical image quality at clinically realistic levels of x-ray photon flux.
Assuntos
Fótons , Tomografia Computadorizada por Raios X/métodos , Humanos , Imagens de Fantasmas , Radiometria/instrumentação , Radiometria/métodos , Tomografia Computadorizada por Raios X/instrumentação , Raios XRESUMO
The primary goal of our study was to determine changes in bone mineralization in postmenopausal osteoporotic women treated for 3 years with risedronate or placebo. A secondary goal was to determine the relationship between mineralization and indices of bone turnover measured on the same biopsies. The degree of mineralization was measured by micro-computed tomography using Synchrotron radiation (Synchrotron microCT) in the trabecular bone of paired transiliac biopsies taken at baseline and after 3 years of treatment from patients receiving risedronate 5 mg daily (n=11) or placebo (n=8). In the risedronate-treated patients, the average mineralization (Avg-MIN) and peak mineralization (Peak-MIN) at 3 years were significantly increased from baseline by 4.7% (P<0.0001) and 5.4% (P=0.0003), respectively and showed significant negative correlation to turnover indices. In the placebo-treated patients, the increases in Avg-MIN (2.0%) and Peak-MIN (1.6%) were not significantly different from baseline and correlation to turnover indices was weaker. Risedronate significantly reduced the ratio of low- to high-mineralized bone fractions estimated by volume (BMR-V) and surface area (BMR-S) by 70.1% and 54.1%, respectively from baseline. These changes were consistent with the significant reduction of turnover from baseline assessed by reductions in mineralizing surface, MS/BS (-72.8%); activation frequency, Ac.F (-60.4%); and bone formation rate, BFR-BV (-63.6%) in the same biopsies in the risedronate-treated patients. Comparing the pair-wise changes from baseline, risedronate significantly reduced the low-mineralized bone fraction in comparison to placebo, as indicated by a larger reduction of BMR-V (P=0.015) and BMR-S (P=0.035). In the risedronate group, BMR-V and BMR-S showed significant positive correlation to MS/BS (R2: 0.83 and 0.92, respectively). The correlations to Ac.F and BFR-BV were also significant, with BMR-S showing a strong relation (R2: 0.77 and 0.79, respectively). The data suggest that BMR-V and BMR-S are markers of turnover of trabecular bone and may be used to assess treatment effect on turnover in bone biopsies. The results demonstrate that the reduction of turnover by risedronate increased the degree of mineralization and reduced the ratio of low- to high-mineralized bone fractions which may increase bone's resistance to fracture.
Assuntos
Calcificação Fisiológica/efeitos dos fármacos , Ácido Etidrônico/análogos & derivados , Osteoporose Pós-Menopausa/tratamento farmacológico , Tomografia Computadorizada por Raios X/métodos , Idoso , Biópsia , Densidade Óssea , Conservadores da Densidade Óssea/farmacologia , Conservadores da Densidade Óssea/uso terapêutico , Interpretação Estatística de Dados , Ácido Etidrônico/farmacologia , Ácido Etidrônico/uso terapêutico , Feminino , Humanos , Ílio/efeitos dos fármacos , Ílio/patologia , Vértebras Lombares/química , Pessoa de Meia-Idade , Osteoporose Pós-Menopausa/patologia , Ácido Risedrônico , Síncrotrons , Fatores de Tempo , Tomografia Computadorizada por Raios X/instrumentação , Resultado do TratamentoRESUMO
A combination of experimental, theoretical, and imaging methodologies is used to examine the hierarchical structure and function of intramyocardial arteriolar trees in porcine hearts to provide a window onto a region of myocardial microvasculature which has been difficult to fully explore so far. A total of 66 microvascular trees from 6 isolated myocardial specimens were analyzed, with a cumulative number of 2438 arteriolar branches greater than or equal to 40 µm lumen diameter. The distribution of flow rates within each tree was derived from an assumed power law relationship for that tree between the diameter of vessel segments and flow rates that are consistent with that power law and subject to conservation of mass along hierarchical structure of the tree. The results indicate that the power law index increases at levels of arteriolar vasculature closer to the capillary level, consistent with a concomitant decrease in shear stress acting on endothelial tissue. These results resolve a long standing predicament which could not be resolved previously because of lack of data about the 3D, interconnected, arterioles. In the context of myocardial perfusion, the results indicate that the coefficient of variation of flow rate in pre-capillary distal arterioles is high, suggesting that heterogeneity of flow rate in these arterioles is not entirely random but may be due at least in part to active control.
Assuntos
Arteríolas/fisiologia , Circulação Coronária/fisiologia , Coração/fisiologia , Miocárdio , Animais , Vasos Coronários/diagnóstico por imagem , Vasos Coronários/fisiologia , Coração/diagnóstico por imagem , Microvasos/diagnóstico por imagem , Microvasos/fisiologia , Suínos , Microtomografia por Raio-XRESUMO
BACKGROUND AND AIMS OF THE STUDY: For implanted Björk-Shiley convexo-concave (BSCC) heart valves, structural failure of the valve's U-shaped outlet strut results in embolization of its blood flow-regulating disc (occluder), with consequent patient morbidity and mortality. After a variable and unpredictable number of cardiac cycles, one strut leg may fatigue ('single-leg separation'; SLS); subsequently the other strut leg may also fatigue, resulting in full structural failure ('outlet strut failure'; OSF). Some BSCC valves are believed to be at more risk of SLS and OSF than others. As valves may function in the SLS condition for some time before OSF occurs, several investigators have sought non-invasive methods to differentiate valves with SLS struts from valves with intact struts in order to provide a rationale for prophylaxis. Herein, we report the use of X-ray microcomputed tomography (micro-CT) to image and characterize SLS strut fractures, including fracture faces otherwise visible only by means of physical sectioning. METHODS: An X-ray micro-CT system was adapted to provide high-resolution, three-dimensional (3D) images of intact and fractured BSCC valve outlet struts in vitro. System modifications included use of a tungsten anode X-ray source to achieve sufficiently high X-ray energies to overcome attenuation within the metal structures, and a hafnium filter to minimize the imaging artifact caused by X-ray beam hardening. For rotating the valve for tomographic scanning, special alignment procedures were developed to maintain the region of interest within the field of view. Typical 3D images of the outlet struts were composed of cubic voxels, 10 microm on a side. Image analysis and display software was used to view the outlet struts and the fractures from several perspectives, including en-face images of fracture surfaces. RESULTS: 3D volume data representations of the SLS and intact outlet struts were obtained, facilitating identification of fracture location and geometry. Enface images of the fracture surfaces were also generated. Several different fracture geometries were observed, such as fractures with and without longitudinal gaps between the fracture faces, and fractures with and without lateral displacement between the faces. En-face views showed varying degrees of roughness on fracture faces. CONCLUSION: This application of micro-CT to image outlet strut fractures in BSCC valve explants demonstrates the value of this method for fracture characterization in vitro, including visualization of fracture faces of SLS struts without physical sectioning. Although the method is not suitable for clinical use because it requires high-intensity X-rays, micro-CT can serve as a tool to understand further any failure mechanisms, and to aid the development of clinical differentiation methods.
Assuntos
Próteses Valvulares Cardíacas , Falha de Prótese , Tomografia Computadorizada por Raios X/métodos , Humanos , Processamento de Imagem Assistida por Computador , Imageamento TridimensionalRESUMO
A double-walled copper vessel, 32 cc in volume, was fabricated for scanning tissue specimens while maintained below freezing point. To keep specimen temperature within +/- 1 degrees C, temperature sensors within the chamber control, the rate of inflow of the cold nitrogen gas vented through the chamber. The specimen is attached to a small platform on top of a vertical pin which is attached to the computer-controlled rotating stage under the vessel. The purpose of this arrangement is to permit scanning of specimens up to 2 cm3 that (1) cannot be "fixed" (e.g., with formalin) because of analyses which are incompatible with prior fixation (certain immunohistochemistry and biomolecular methods), or (2) are "snap"-frozen during a transient process, such as the accumulation and/or washout of radiopaque indicators. Examples of "cryoscans" of porcine carotid and coronary artery wall opacification in either untouched or acutely stented arteries, snap-frozen immediately after selective intra-arterial injection of a contrast agent, show accumulation of contrast in the extravascular space indicating increased endothelial permeability or endothelial and medial disruption following stent placement. The detection of contrast in the adventitia suggest that vasa vasorum deliver the contrast agent from the main lumen to the adventitial extravascular space but not to the media.
Assuntos
Artérias Carótidas/diagnóstico por imagem , Angiografia Coronária/métodos , Processamento de Imagem Assistida por Computador/métodos , Tomografia Computadorizada por Raios X/métodos , Angiografia/métodos , Animais , Meios de Contraste , Criopreservação , Perfusão , Suínos , Tomografia Computadorizada por Raios X/instrumentação , Vasa Vasorum/diagnóstico por imagemRESUMO
PURPOSE: To examine the anatomy of Schlemm's canal (SC) and collector channels (CCs) in normal human and primary open-angle glaucoma (POAG) eyes under low and high perfusion pressure. METHODS: In normal (n = 3) and POAG (n = 3) eye pairs, one eye was perfused at 10 mm Hg while the fellow eye was perfused at 20 mm Hg for 2 hours. Eyes were perfusion fixed at like pressures, dissected into quadrants, embedded in Epon Araldite, and scanned by three-dimensional micro-computed tomography (3D micro-CT). Schlemm's canal volume, CC orifice area, diameter, and number were measured using ANALYZE software. RESULTS: Normal eyes showed a larger SC volume (3.3-fold) and CC orifice area (9962.8 vs. 8825.2 µm(2)) and a similar CC diameter (34.3 ± 17.8 vs. 32.7 ± 13.0 µm) at 10 mm Hg compared to 20 mm Hg. In POAG eyes, SC volume (2.0-fold), CC orifice area (8049.2 µm(2)-6468.4 µm(2)), and CC diameter (36.2 ± 19.1 vs. 29.0 ± 13.8 µm) were increased in 10 mm Hg compared to 20 mm Hg perfusion pressures. Partial and total CC occlusions were present in normal and POAG eyes, with a 3.7-fold increase in total occlusions in POAG eyes compared to normal eyes at 20 mm Hg. Visualization of CCs increased by 24% in normal and by 21% in POAG eyes at 20 mm Hg compared to 10 mm Hg. Schlemm's canal volume, CC area, and CC diameter were decreased in POAG eyes compared to normal eyes at like pressures. CONCLUSIONS: Compensatory mechanisms for transient and short periods of increased pressure appear to be diminished in POAG eyes. Variable response to pressure change in SC and CCs may be a contributing factor to outflow facility change in POAG eyes.
Assuntos
Glaucoma de Ângulo Aberto/fisiopatologia , Pressão Intraocular/fisiologia , Malha Trabecular/patologia , Idoso , Idoso de 80 Anos ou mais , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Malha Trabecular/anatomia & histologiaRESUMO
There is an increased body of evidence to suggest that the vasa vasorum play a major role in the progression and complications of vulnerable plaque leading to acute coronary syndrome. We propose that detecting changes in the flow in the vascular wall by intravascular ultrasound signals can quantify the presence of vasa vasorum. The results obtained in a porcine model of atherosclerosis suggest that intravascular ultrasound-based estimates of blood flow in the arterial wall can be used in vivo in a clinical research setting to establish the density of vasa vasorum as an indicator of plaque vulnerability.
Assuntos
Doença da Artéria Coronariana/diagnóstico por imagem , Circulação Coronária , Vasos Coronários/diagnóstico por imagem , Ultrassonografia de Intervenção , Vasa Vasorum/diagnóstico por imagem , Animais , Doença da Artéria Coronariana/fisiopatologia , Vasos Coronários/fisiopatologia , Modelos Animais de Doenças , Diagnóstico Precoce , Estudos de Viabilidade , Feminino , Placa Aterosclerótica , Valor Preditivo dos Testes , Sus scrofa , Vasa Vasorum/fisiopatologiaRESUMO
Structural data about the human lung fine structure are mainly based on stereological methods applied to serial sections. As these methods utilize 2D images, which are often not contiguous, they suffer from inaccuracies which are overcome by analysis of 3D micro-CT images of the never-sectioned specimen. The purpose of our study was to generate a complete data set of the intact three-dimensional architecture of the human acinus using high-resolution synchrotron-based micro-CT (synMCT). A human lung was inflation-fixed by formaldehyde ventilation and then scanned in a 64-slice CT over its apex to base extent. Lung samples (8-mm diameter, 10-mm height, N = 12) were punched out, stained with osmium tetroxide, and scanned using synMCT at (4 µm)(3) voxel size. The lung functional unit (acinus, N = 8) was segmented from the 3D tomographic image using an automated tree-analysis software program. Morphometric data of the lung were analyzed by ANOVA. Intra-acinar airways branching occurred over 11 generations. The mean acinar volume was 131.3 ± 29.2 mm(3) (range, 92.5-171.3 mm(3)) and the mean acinar surface was calculated with 1012 ± 26 cm(2). The airway internal diameter (starting from the bronchiolus terminalis) decreases distally from 0.66 ± 0.04 mm to 0.34 ± 0.06 mm (P < 0.001) and remains constant after the seventh generation (P < 0.5). The length of each generation ranges between 0.52 and 0.93 mm and did not show significant differences between the second and eleventh generation. The branching angle between daughter branches varies between 113-degree and 134-degree without significant differences between the generations (P < 0.3). This study demonstrates the feasibility of quantitating the 3D structure of the human acinus at the spatial resolution readily achievable using synMCT.
Assuntos
Imageamento Tridimensional , Pulmão/anatomia & histologia , Microtomografia por Raio-X , Adulto , Humanos , Processamento de Imagem Assistida por Computador , Imageamento Tridimensional/métodos , Pulmão/diagnóstico por imagem , Masculino , Software , SíncrotronsRESUMO
Analog summation methods of x-ray imaging have nonlinearity in signal readout and dynamic range limitations. To minimize these limitations, a photon counting CCD-based gamma camera imaging system has been developed and evaluated.
Assuntos
Câmaras gama , Aumento da Imagem/instrumentação , Semicondutores , Técnica de Subtração/instrumentação , Tomografia Computadorizada de Emissão de Fóton Único/instrumentação , Tomografia Computadorizada por Raios X/instrumentação , Desenho Assistido por Computador , Desenho de Equipamento , Análise de Falha de Equipamento , Miniaturização , Fótons , Reprodutibilidade dos Testes , Sensibilidade e EspecificidadeRESUMO
The objective of this study was to investigate the influence of pore geometry on the transport rate and depth after repetitive mechanical deformation of porous scaffolds for tissue engineering applications. Flexible cubic imaging phantoms with pores in the shape of a circular cylinder, elliptic cylinder, and spheroid were fabricated from a biodegradable polymer blend using a combined 3D printing and injection molding technique. The specimens were immersed in fluid and loaded with a solution of a radiopaque solute. The solute distribution was quantified by recording 20 microm pixel-resolution images in an X-ray microimaging scanner at selected time points after intervals of dynamic straining with a mean strain of 8.6+/-1.6% at 1.0 Hz. The results show that application of cyclic strain significantly increases the rate and depth of solute transport, as compared to diffusive transport alone, for all pore shapes. In addition, pore shape, pore size, and the orientation of the pore cross-sectional asymmetry with respect to the direction of strain greatly influence solute transport. Thus, pore geometry can be tailored to increase transport rates and depths in cyclically deformed scaffolds, which is of utmost importance when thick, metabolically functional tissues are to be engineered.