Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 40
Filtrar
1.
Artigo em Inglês | MEDLINE | ID: mdl-38713879

RESUMO

PURPOSE: An increased value of tibiofemoral rotation is frequently observed in patients with patellofemoral instability or maltracking. Nevertheless, the appropriate approach for addressing this parameter remains unclear so far. One potential approach for correcting tibiofemoral rotation is femoral rotational osteotomy. We hypothesized that femoral rotational osteotomy affects tibiofemoral rotation. METHODS: All patients who underwent femoral rotational osteotomy between January 2018 and May 2022 were included in this study. Pre- and postoperative tibiofemoral rotation and the degree of femoral rotation were measured using two-dimensional (2D) and three-dimensional (3D) measurements. The effect of femoral rotation on tibiofemoral rotation was assessed. RESULTS: Forty knees (18 right and 22 left) of 36 patients (28 females and 8 males) were included. Mean preoperative femoral torsion was 32.1 ± 10.1° in 2D and 30.8 ± 10.1° in 3D. Femoral rotation was performed by -14.1 ± 8.3° using 2D measurements and -15.0 ± 8.0° using 3D measurements. Tibiofemoral rotation changed from 9.9 ± 6.2° to 9.7 ± 6.0° (p = n.s.) in 2D, and from 10.2 ± 5.5° to 9.4 ± 5.4° (p = n.s.) in 3D. CONCLUSION: Tibiofemoral rotation showed no significant changes after femoral rotational osteotomy. Hence, femoral rotational osteotomy cannot be used to correct tibiofemoral rotation in addition to correcting the femoral version. Other surgical techniques need to be evaluated if correction of tibiofemoral rotation is required. LEVEL OF EVIDENCE: Level III.

2.
Knee Surg Sports Traumatol Arthrosc ; 32(5): 1179-1186, 2024 May.
Artigo em Inglês | MEDLINE | ID: mdl-38504510

RESUMO

PURPOSE: The multifactorial nature of patellofemoral instability requires a comprehensive assessment of the affected patients. While an association between tibial tuberosity (TT) torsion and patellofemoral instability is known, its specific effect has not yet been investigated. This study investigated the effect of TT torsion on patellofemoral instability. METHODS: This retrospective cohort study compared patients who underwent surgical intervention for patellofemoral instability and asymptomatic controls. TT torsion was measured in addition to other commonly assessed risk factors for patellofemoral instability using standardised computed tomography (CT) data of the lower extremities. The diagnostic performances of the assessed parameters were evaluated using receiver operating characteristic curve analysis and odds ratios (ORs) were calculated. RESULTS: The patellofemoral instability group consisted of 79 knees, compared to 72 knees in the asymptomatic control group. Both groups differed significantly in all assessed parameters (p < 0.001), except for tibial torsion (n.s.). Among all parameters, TT torsion presented the best diagnostic performance for predicting patellar instability with an area under the curve of 0.95 (95% confidence interval [CI], 0.91-0.98; p < 0.001). A cut-off value of 17.7° yielded a 0.87 sensitivity and 0.89 specificity to predict patellar instability (OR, 55.2; 95% CI, 20.5-148.6; p < 0.001). CONCLUSION: Among the evaluated risk factors, TT torsion had the highest predictive value for patellofemoral instability. Patients with TT torsions ≥ 17.7° showed a 55-fold increased probability of patellofemoral instability. Therefore, TT torsion should be included in the assessment of patients with patellofemoral instability. LEVEL OF EVIDENCE: Level III.


Assuntos
Instabilidade Articular , Articulação Patelofemoral , Tíbia , Tomografia Computadorizada por Raios X , Humanos , Instabilidade Articular/cirurgia , Instabilidade Articular/diagnóstico , Masculino , Feminino , Estudos Retrospectivos , Adulto , Articulação Patelofemoral/diagnóstico por imagem , Articulação Patelofemoral/cirurgia , Tíbia/cirurgia , Tíbia/diagnóstico por imagem , Valor Preditivo dos Testes , Adulto Jovem , Fatores de Risco , Anormalidade Torcional/cirurgia , Anormalidade Torcional/diagnóstico , Anormalidade Torcional/diagnóstico por imagem , Curva ROC , Adolescente
3.
Int Orthop ; 48(5): 1217-1224, 2024 May.
Artigo em Inglês | MEDLINE | ID: mdl-38388804

RESUMO

PURPOSE: Lateralized stems in primary cementless total hip arthroplasty (THA) showed to be associated with aseptic femoral loosening. However, femoral head length also affects femoral offset but was not considered so far. This study analyzed the impact of high femoral offset (hFO) combinations, formed by lateralized stems or large femoral head lengths, on aseptic femoral component loosening. METHODS: Retrospective cohort study was performed including all patients that underwent primary cementless THA at our institution between July 2004 and December 2016. Patients were screened for aseptic femoral component loosening and grouped in aseptic loosening (AL) and non-aseptic loosening (nAL) group. Medical records were screened; implant details were noted and classified in hFO and standard femoral offset (sFO) combinations. Supposed risk factors for aseptic loosening were analyzed. RESULTS: Two thousand four hundred fifty-nine THA could be included, containing 14 THA (0.6%) with aseptic femoral component loosening. The AL group contained 11 hFO combinations (78.6%), whereas in the nAL group, 1315 hFO combinations (53.8%) were used. Subgroup analysis showed significant difference between two groups for hFO combinations (p = 0.014), age (p = 0.002), NSAR (p = 0.001), and bilateral THA on same day (p = 0.001). The multiple logistic regression analysis showed that hFO combination was the only variable for increased probability of aseptic loosening (OR, 3.7; p = 0.04). CONCLUSION: High femoral offset combinations, formed by lateralized stems or large femoral head lengths in our collective of standard straight stems implanted by an anterior approach, show a 3.7-fold increased probability for aseptic femoral component loosening. Adjustment of the postoperative protocol may be considered in these cases to ensure proper stem ingrowth.


Assuntos
Artroplastia de Quadril , Prótese de Quadril , Humanos , Artroplastia de Quadril/efeitos adversos , Artroplastia de Quadril/métodos , Prótese de Quadril/efeitos adversos , Estudos Retrospectivos , Seguimentos , Falha de Prótese , Reoperação/efeitos adversos , Desenho de Prótese , Fatores de Risco , Resultado do Tratamento
4.
Int Orthop ; 2024 Apr 29.
Artigo em Inglês | MEDLINE | ID: mdl-38684549

RESUMO

PURPOSE: Symptomatic hips with borderline hip dysplasia (BHD) morphology pose a challenge in differentiating stable from unstable hips. The current study aims to compare indirect radiographic signs of instability in a symptomatic BHD population to those in a healthy cohort. METHODS: The study group consisted of patients with a lateral centre-edge angle (LCEA) with values 18° ≤ LCEA < 25° who underwent corrective periacetabular osteotomy (PAO) and reported an improvement in patient-reported outcome measures (PROMs). The comparison group consisted of a healthy cohort of athletes who did not complain of any hip-related symptoms and who had normal values of their hip morphological parameters (LCEA, acetabular index (AI°), alpha angle (α°), femoral version, acetabular version). Indirect signs of instability consisting of the femoro-epiphyseal acetabular roof index (FEAR), iliocapsularis-to-rectus-femoris (IC/RF) ratio and labral dimensions (height-to-length ratio) were assessed in both groups. Partial Pearson correlation, logistic multiple regression analysis and Receiver-Operating Characteristic (ROC) curve analysis were performed to determine correlations, as well as the sensitivity and specificity of these signs to differentiate between healthy hips and BHD. RESULTS: On binary logistic multiple regression analysis, the FEAR Index was the only independent predictor to differentiate between BHD and healthy hips (p < 0.001). The IC/RF ratio did not achieve significance. The calculated area under the curve (AUC) was 0.93 (0.87 - 0.99, CI 95%, p < 0.001) for the FEAR Index and 0.81 (0.70 - 0.92, CI 95%, p < 0.001) for the height-length ratio. Using the predefined cut-off values (dysplastic-FEAR Index ≥ 5° or labral height-to-length ratio ≤ 0.5), 27% sensitivity/100% specificity and 20% sensitivity/ 100% specificity, were achieved. ROC analysis provided the following new thresholds: FEAR Index ≥ -5° (73% sensitivity/97% specificity); labral height-to-length ratio ≤ 0.8 (70% sensitivity, 79% specificity). CONCLUSION: In our cohort, the FEAR index was an independent parameter that could differentiate between borderline dysplastic and asymptomatic hips. The previously published values for both the FEAR index and labral hypertrophy ratio had a poor sensitivity in differentiating symptomatic unstable BHD from healthy hips. The cut-off values of ≥ -5° (FEAR index) and ≤ 0.8 (labral height-to-length ratio) provided acceptable sensitivity and specificity when comparing to morphological healthy hips.

5.
Arthroscopy ; 2023 Dec 25.
Artigo em Inglês | MEDLINE | ID: mdl-38151166

RESUMO

PURPOSE: To investigate the impact of hip adduction and abduction on the femoro-epiphyseal acetabular roof (FEAR) index using conventional anteroposterior pelvic radiographs of patients with borderline hip dysplasia (BHD). METHODS: Patients with BHD (lateral center edge angle [LCEA] with values of 18° ≤ LCEA <25°) and who were subject to periacetabular osteotoym were selected from a consecutive retrospective cohort from January 2009 to January 2016. The hip ad-/abduction (adduction handled as negative values) and the FEAR index (lateral opening angles handled as positive values) were measured in the initially standardized acquired pelvic radiographs. Thereafter, using surgical planning software, different degrees of hip adduction and abduction were simulated from 20° of adduction to 30° of abduction, and the FEAR index was measured at each position. Pearson correlation was used to identify a potential correlation between the hip ad-/abduction and the FEAR index. RESULTS: Eighty-nine hips were included. Initial radiographs showed unintentional mean ad-/abduction of -5.3° ± 3.1° (range, -14° to 2°). The mean FEAR index at the initial ad-/abduction angle was -3.6° ± 7.2° (range, -18.0° to 16.0°) and was significantly different from neutral position (0° of ad-/abduction) -9.2° ± 7.0° (range, -27.0° to 10.0°) (P < .001). The FEAR index was negatively correlated to the hip ad-/abduction angle (r = 1, P < .001), with lower values for the FEAR index with the hip in abduction. CONCLUSIONS: Significant differences in FEAR index measurements were observed depending on hip ad-/abduction on pelvic radiographs. A linear change of the FEAR index of 5° per 5° of hip adduction or abduction could be demonstrated, with adduction resulting in increasing and abduction in decreasing values for the FEAR index. LEVEL OF EVIDENCE: Level III, diagnostic study.

6.
Knee Surg Sports Traumatol Arthrosc ; 31(4): 1500-1506, 2023 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-33891162

RESUMO

PURPOSE: Medial open wedge high tibial osteotomy (MOWHTO) is an effective treatment option for realignment of a varus knee. However, a simple supra-tuberositary osteotomy can lead to patella baja and potentially increases the tibial tuberosity-trochlear groove distance (TTTG). The purpose of this study was to quantify the influence of MOWHTO on TTTG. METHODS: Three-dimensional (3D) surface models of five lower extremities with a varus hip-knee-ankle angle (HKA) and a borderline TTTG (≥ 15 mm), five lower extremities with a varus HKA and a normal TTTG (< 15 mm) and a 3D statistical shape model (SSM) of a neutrally aligned healthy knee were analysed by simulating MOWHTO with a stepwise increment of one degree of valgisation from the preoperative coronal deformity (0°-15°) for each patient, resulting in a total of 165 simulations. Postoperative 3D TTTG and tibial torsion (TT) were measured for each simulation. A mathematical formula was developed to calculate the increase of TTTG after MOWHTO. Mean differences between simulated and calculated TTTG were analysed. RESULTS: Mean preoperative HKA was 6.5 ± 3.0° varus (range 0.8°-11.5°). Mean TTTG increased from 14.2 ± 3.2 mm (range 9.6-19.1) preoperatively to 18.8 ± 3.8 mm (range 14.5-25.0) postoperatively (p = 0.001). TTTG increased approximately linear by + 0.5 ± 0.2° (range 0.3-0.8) per 1° of valgisation with a high positive correlation (0.99, p = 0.001) from 0° to 15°. Mean difference between simulated and calculated TTTG was 0.03 ± 0.02 mm (range 0.01-0.07) per 1° of valgisation (p < 0.001). CONCLUSION: MOWHTO results in an approximately linear increase in TTTG of + 0.5 mm per 1° of valgisation in the range from 0° to 15° and the lateralisation of the tibial tuberosity can be calculated reliably using the described formula. Preoperative analysis of TTTG in patients undergoing MOWHTO may prevent unintentional patellofemoral malalignment. LEVEL OF EVIDENCE: III.


Assuntos
Osteoartrite do Joelho , Patela , Humanos , Patela/cirurgia , Tíbia/cirurgia , Articulação do Joelho/cirurgia , Osteotomia/métodos , Extremidade Inferior , Osteoartrite do Joelho/cirurgia , Estudos Retrospectivos
7.
Knee Surg Sports Traumatol Arthrosc ; 31(12): 5293-5298, 2023 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-37715052

RESUMO

PURPOSE: Revision total knee arthroplasty (RTKA) results in high costs with inadequately low reimbursement in different healthcare systems. Therefore, a financial analysis was performed comparing costs and reimbursements of primary total knee arthroplasty (PTKA) versus RTKA using financial and total knee arthroplasty-register data from a large tertiary hospital, the Cantonal Hospital of St. Gallen (KSSG), Switzerland. METHODS: All PTKA and RTKA performed between January 2012 and September 2019 at the KSSG were included. Financial and TKA-register data for each case were collected, including detailed cost allocation, reimbursement, patients' insurance status, type and indication for surgery and length of hospital stay. RTKA was further subdivided in one-stage and two-stage RTKA. Direct hospital costs were analyzed and compared to reimbursement in both groups. Cost-coverage ratios were calculated. RESULTS: 730 PTKA and 106 RTKA were included. The RTKA group contained 66 one-stage and 40 two-stage RTKA. Cost-coverage ratio for PTKA and RTKA showed to be 110.9% and 81.3%, respectively. Cost-coverage ratio was lower for two-stage RTKA than for one-stage RTKA with 74.1% and 92.3%, respectively. CONCLUSION: RTKA leads to financial deficits especially for tertiary hospitals within the Swiss healthcare system. Restructuring of the reimbursements for PTKA and RTKA should be considered in favor of RTKA. Otherwise, tertiary hospitals will face a growing financial burden with the constantly increasing annual number of RTKA procedures, predominantly performed in this type of hospitals. LEVEL OF EVIDENCE: III.


Assuntos
Artroplastia do Joelho , Humanos , Artroplastia do Joelho/métodos , Suíça , Atenção à Saúde , Hospitais , Fatores de Tempo , Reoperação , Estudos Retrospectivos
8.
Knee Surg Sports Traumatol Arthrosc ; 30(2): 389-396, 2022 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-34417835

RESUMO

PURPOSE: Joint line orientation (JLO) plays an important role in total knee arthroplasty (TKA), but its influence on patient-reported outcomes (PROs) is unclear. The purpose of this study was to examine JLO impact as measured by the forgotten joint score (FJS-12). The hypothesis was that restoring the joint line (JL) parallel to the floor would influence joint awareness favorably, i.e., allow the patient to forget about the joint in daily living. METHODS: All computer-navigated primary TKAs using a cemented, cruciate-retaining (CR) design implanted between January 2018 and September 2019 were reviewed in this retrospective single-center analysis. Primary endpoints were: clinical [range of motion (ROM)], and patient-reported (FJS-12) and radiographical outcomes [tibia joint line angle (TJLA), hip knee axis (HKA), mechanical medial proximal tibia angle (mMPTA) as well as mechanical lateral distal femoral angle (mLDFA)]. RESULTS: Seventy-six patients (mean age: 70.3 ± 9.7 years, mean BMI: 29.7 ± 5.2 kg/m2) were included. Postoperative ROM averaged 118.7 ± 9.6°. The mean FJS-12 improved from 16.4 ± 15.3 (preoperatively) to 89.4 ± 16.9 (1-year follow-up; p < 0.001). Clinical outcomes and PROs did not correlate with JLO (p = n.s.). Cluster analysis using six measures revealed that a medially opened TJLA was associated with significantly better postoperative FJS-12. CONCLUSION: Tibial JLO was found to have no effect on PROs. Considering the JLO in the coronal plane alone probably has questionable clinical relevance. Lower limb alignment should be assessed in all three planes and correlated with the clinical outcome. LEVEL OF CLINICAL EVIDENCE: Level IV.


Assuntos
Artroplastia do Joelho , Prótese do Joelho , Osteoartrite do Joelho , Idoso , Idoso de 80 Anos ou mais , Humanos , Articulação do Joelho/diagnóstico por imagem , Articulação do Joelho/cirurgia , Pessoa de Meia-Idade , Osteoartrite do Joelho/cirurgia , Estudos Retrospectivos , Tíbia/cirurgia
9.
J Hand Surg Am ; 47(7): 691.e1-691.e10, 2022 07.
Artigo em Inglês | MEDLINE | ID: mdl-34507869

RESUMO

PURPOSE: Our study aimed to analyze the functional and radiological intermediate-term outcome of 3-dimensional-guided corrective osteotomies for malunited distal radius fractures and to evaluate the progression of osteoarthritis after this intervention. METHODS: All patients with malunited distal radius fractures who underwent 3-dimensional-guided corrective osteotomies from October 2008 to January 2015 were included. Pre- and postoperative range of motion, grip strength, and postoperative patient-reported outcomes were assessed. Pre- and postoperative osteoarthritis grading was performed using conventional radiographs and the osteoarthritis grading system described by Knirk and Jupiter. Additionally, the evaluation of articular stepoff was performed using pre- and postoperative computed tomography. RESULTS: Fifteen patients, with a mean follow-up of 6 years (range, 4.1-10.4 years), were included. According to rater 1, 8 cases had no postoperative osteoarthritis progression, 6 cases had progression of 1 grade, and 1 case had progression of 2 grades. According to rater 2, there was no progression in 11 cases, and there was progression of 1 grade in 2 cases and progression of 2 grades in 2 cases. Compared with before the surgery, the patients demonstrated a mean improvement of 14.8 kg (±12.6 kg) in grip strength after the surgery. At the last follow-up, the mean Patient-Rated Wrist Evaluation score was 11.8 (±12.0), the mean Disabilities of the Arm, Shoulder and Hand score was 11.1 (±11.4), and the mean residual pain score on the visual analog scale was 0.8 (±1.0). CONCLUSIONS: The intermediate-term outcome of 3-dimensional-guided corrective osteotomies for distal radius intra-articular malunions showed excellent patient-reported outcomes and no clinically relevant progression of osteoarthritis. TYPE OF STUDY/LEVEL OF EVIDENCE: Therapeutic IV.


Assuntos
Fraturas Mal-Unidas , Osteoartrite , Fraturas do Rádio , Seguimentos , Fraturas Mal-Unidas/diagnóstico por imagem , Fraturas Mal-Unidas/cirurgia , Humanos , Osteoartrite/diagnóstico por imagem , Osteoartrite/cirurgia , Osteotomia/métodos , Rádio (Anatomia) , Fraturas do Rádio/diagnóstico por imagem , Fraturas do Rádio/cirurgia , Amplitude de Movimento Articular , Estudos Retrospectivos , Resultado do Tratamento
10.
BMC Musculoskelet Disord ; 22(1): 739, 2021 Aug 28.
Artigo em Inglês | MEDLINE | ID: mdl-34454445

RESUMO

BACKGROUND: Several hip and knee pathologies are associated with aberrant femoral torsion. Diagnostic workup includes computed tomography (CT) and magnetic resonance imaging (MRI). For three-dimensional (3D) analysis of complex deformities it would be desirable to measure femoral torsion from MRI data to avoid ionizing radiation of CT in a young patient population. 3D measurement of femoral torsion from MRI has not yet been compared to measurements from CT images. We hypothesize that agreement will exist between MRI and CT 3D measurements of femoral torsion. METHODS: CT and MRI data from 29 hips of 15 patients with routine diagnostic workup for suspected femoroacetabular impingement (FAI) were used to generate 3D bone models. 3D measurement of femoral torsion was performed by two independent readers using the method of Kim et al. which is validated for CT. Inter-modalitiy and inter-reader intraclass correlation coefficients (ICC) were calculated. RESULTS: Between MRI and CT 3D measurements an ICC of 0.950 (0.898; 0.976) (reader 1) respectively 0.950 (0.897; 0.976) (Reader 2) was found. The ICC (95% CI) expressing the inter-reader reliability for both modalities was 0.945 (0.886; 0.973) for MRI and 0.957 (0.910; 0.979) for CT, respectively. Mean difference between CT and MRI measurement was 0.42° (MRI - CT, SD: 2.77°, p = 0.253). CONCLUSIONS: There was consistency between 3D measurements of femoral torsion between computer rendered MRI images compared to measurements with the "gold standard" of CT images. ICC for inter-modality and inter-reader consistency indicate excellent reliability. Accurate, reliable and reproducible 3D measurement of femoral torsion is possible from MRI images.


Assuntos
Fêmur , Imageamento Tridimensional , Fêmur/diagnóstico por imagem , Humanos , Imageamento por Ressonância Magnética , Reprodutibilidade dos Testes , Tomografia Computadorizada por Raios X
11.
BMC Musculoskelet Disord ; 21(1): 635, 2020 Sep 26.
Artigo em Inglês | MEDLINE | ID: mdl-32979919

RESUMO

BACKGROUND: The tibial slope plays an important role in knee surgery. However, standard radiographic measurement techniques have a low reproducibility and do not allow differentiation between medial and lateral articular surfaces. Despite availability of three-dimensional imaging, so far, no real 3D measurement technique was introduced and compared to radiographic measurement, which were the purposes of this study. METHODS: Computed tomography scans of 54 knees in 51 patients (41 males and 10 females) with a mean age of 46 years (range 22-67 years) were included. A novel 3D measurement technique was applied by two readers to measure the tibial slope of medial and lateral tibial plateau and rim. A statistical analysis was conducted to determine the intraclass correlation coefficient (ICC) for the new technique and compare it to a standard radiographic measurement. RESULTS: The mean 3D tibial slope for the medial plateau and rim was 7.4° and 7.6°, for the lateral plateau and rim 7.5° and 8.1°, respectively. The mean radiographic slope was 6.0°. Statistical analysis showed an ICC between both readers of 0.909, 0.987, 0.918, 0.893, for the 3D measurement of medial plateau, medial rim, lateral plateau and lateral rim, respectively, whereas the radiographic technique showed an ICC of 0.733. CONCLUSIONS: The proposed novel measurement technique shows a high intraclass agreement and offers an applicable opportunity to assess the tibial slope three-dimensionally. Furthermore, the medial and lateral articular surfaces can be measured separately and one can differentiate the slope from the plateau and from the rim. As three-dimensional planning becomes successively more important, our measurement technique might deliver a useful supplement to the standard radiographic assessment in slope related knee surgery. LEVEL OF EVIDENCE: Level III, diagnostic study.


Assuntos
Articulação do Joelho , Tíbia , Adulto , Idoso , Feminino , Humanos , Imageamento Tridimensional , Articulação do Joelho/diagnóstico por imagem , Articulação do Joelho/cirurgia , Masculino , Pessoa de Meia-Idade , Radiografia , Reprodutibilidade dos Testes , Tíbia/diagnóstico por imagem , Adulto Jovem
12.
BMC Musculoskelet Disord ; 21(1): 50, 2020 Jan 23.
Artigo em Inglês | MEDLINE | ID: mdl-31973718

RESUMO

BACKGROUND: Subtrochanteric or supracondylar femoral rotational osteotomies are established surgical treatments for femoral rotational deformities. Unintended change of the mechanical leg axis is an identified problem. Different attempts exist to plan a correct osteotomy plane, but implementation of the preoperative planning into the surgical situation can be challenging. Goal of this study was to identify the critical threshold of mal-angulation of the osteotomy plane and of femoral rotation that leads to a relevant deviation of the postoperative mechanical leg axis using a computer simulation approach. METHODS: Three-dimensional (3D) surface models of the lower extremity of two patients (Model 1: 42° femoral antetorsion; Model 2: 6° femoral retrotorsion) were generated from computed tomography data. First, baseline subtrochanteric and supracondylar rotational osteotomies, perpendicular to the femoral mechanical axis were simulated. Afterwards, mal-angulated osteotomies in sagittal and frontal plane followed by different degrees of rotation were simulated and frontal mechanical axis was analyzed. RESULTS: 400 mal-angulated osteotomies have been simulated. Mal-angulation of ±30° with 30° rotation showed maximum deviation from preoperative mechanical axis in subtrochanteric osteotomies (4.0° ± 0.4°) and in supracondylar osteotomies (12.4° ± 0.8°). Minimal mal-angulation of 15° in sagittal plane in subtrochanteric osteotomies and mal-angulation of 10° in sagittal plane in supracondylar osteotomies altered the mechanical axis by > 2°. Mal-angulation in sagittal plane showed higher deviations of the mechanical axis (up to 12.4° ± 0.8°), than in frontal plane mal-angulation (up to 4.0° ± 1.9°). CONCLUSION: A femoral rotational osteotomy, perpendicular to the femoral mechanical axis, has no considerable influence on the mechanical leg axis. However, mal-angulation of femoral rotational osteotomies showed relevant changes of the mechanical leg axis. In supracondylar respectively subtrochanteric procedures, mal-angulation of only 10° in combination with already 15° of femoral rotation respectively mal-angulation of 15° in combination with 30° of femoral rotation, can lead to a relevant postoperative mechanical leg axis deviation of more than 2°, wherefore these patients probably would benefit from the use of navigation aids.


Assuntos
Simulação por Computador , Fêmur/diagnóstico por imagem , Imageamento Tridimensional/métodos , Osteotomia/métodos , Rotação , Tomografia Computadorizada por Raios X/métodos , Fêmur/anormalidades , Fêmur/cirurgia , Humanos
13.
BMC Musculoskelet Disord ; 21(1): 418, 2020 Jun 30.
Artigo em Inglês | MEDLINE | ID: mdl-32605616

RESUMO

BACKGROUND: Deformity assessment and preoperative planning of realignment surgery are conventionally based on weight-bearing (WB) radiographs. However, newer technologies such as three-dimensional (3D) preoperative planning and surgical navigation with patient-specific instruments (PSI) rely on non-weight bearing (NWB) computed tomography (CT) data. Additionally, differences between conventional two-dimensional (2D) and 3D measurements are known. The goal of the present study was to systematically analyse the influence of WB and the measurement modality (2D versus 3D) on common WB-dependent measurements used for deformity assessment. METHODS: 85 lower limbs could be included. Two readers measured the hip-knee-ankle angle (HKA) and the joint line convergence angle (JLCA) in 2D WB and 2D NWB radiographs, as well as in CT-reconstructed 3D models using an already established 3D measurement method for HKA, and a newly developed 3D measurement method for JLCA, respectively. Interrater and intermodality reliability was assessed. RESULTS: Significant differences between WB and NWB measurements were found for HKA (p < 0.001) and JLCA (p < 0.001). No significant difference could be observed between 2D HKA NWB and 3D HKA (p = 0.09). The difference between 2D JLCA NWB and 3D JLCA was significant (p < 0.001). The intraclass correlation coefficient (ICC) for the interrater agreement was almost perfect for all HKA and 3D JLCA measurements and substantial for 2D JLCA WB and 2D JLCA NWB. ICC for the intermodality agreement was almost perfect between 2D HKA WB and 2D HKA NWB as well as between 2D HKA NWB and 3D HKA, whereas it was moderate between 2D JLCA WB and 2D JLCA NWB and between 2D JLCA NWB and 3D JLCA. CONCLUSION: Limb loading results in significant differences for both HKA and JLCA measurements. Furthermore, 2D projections were found to be insufficient to represent 3D joint anatomy in complex cases. With an increasing number of surgical approaches based on NWB CT-reconstructed models, research should focus on the development of 3D planning methods that consider the effects of WB on leg alignment.


Assuntos
Deformidades Congênitas dos Membros/cirurgia , Extremidade Inferior/cirurgia , Osteotomia/métodos , Tomografia Computadorizada por Raios X/métodos , Adolescente , Adulto , Feminino , Humanos , Imageamento Tridimensional , Deformidades Congênitas dos Membros/diagnóstico por imagem , Extremidade Inferior/diagnóstico por imagem , Masculino , Pessoa de Meia-Idade , Modelos Anatômicos , Radiografia , Reprodutibilidade dos Testes , Cirurgia Assistida por Computador , Suíça , Adulto Jovem
14.
BMC Musculoskelet Disord ; 21(1): 103, 2020 Feb 15.
Artigo em Inglês | MEDLINE | ID: mdl-32061248

RESUMO

BACKGROUND: Computer-assisted solutions are changing surgical practice continuously. One of the most disruptive technologies among the computer-integrated surgical techniques is Augmented Reality (AR). While Augmented Reality is increasingly used in several medical specialties, its potential benefit in orthopedic surgery is not yet clear. The purpose of this article is to provide a systematic review of the current state of knowledge and the applicability of AR in orthopedic surgery. METHODS: A systematic review of the current literature was performed to find the state of knowledge and applicability of AR in Orthopedic surgery. A systematic search of the following three databases was performed: "PubMed", "Cochrane Library" and "Web of Science". The systematic review followed the Preferred Reporting Items on Systematic Reviews and Meta-analysis (PRISMA) guidelines and it has been published and registered in the international prospective register of systematic reviews (PROSPERO). RESULTS: 31 studies and reports are included and classified into the following categories: Instrument / Implant Placement, Osteotomies, Tumor Surgery, Trauma, and Surgical Training and Education. Quality assessment could be performed in 18 studies. Among the clinical studies, there were six case series with an average score of 90% and one case report, which scored 81% according to the Joanna Briggs Institute Critical Appraisal Checklist (JBI CAC). The 11 cadaveric studies scored 81% according to the QUACS scale (Quality Appraisal for Cadaveric Studies). CONCLUSION: This manuscript provides 1) a summary of the current state of knowledge and research of Augmented Reality in orthopedic surgery presented in the literature, and 2) a discussion by the authors presenting the key remarks required for seamless integration of Augmented Reality in the future surgical practice. TRIAL REGISTRATION: PROSPERO registration number: CRD42019128569.


Assuntos
Realidade Aumentada , Procedimentos Ortopédicos/métodos , Cirurgia Assistida por Computador/métodos , Humanos , Imageamento Tridimensional/métodos , Cirurgiões/educação , Realidade Virtual
15.
Knee Surg Sports Traumatol Arthrosc ; 28(5): 1356-1364, 2020 May.
Artigo em Inglês | MEDLINE | ID: mdl-30806756

RESUMO

PURPOSE: Patient-specific instruments (PSIs) are helpful tools in high tibial osteotomy (HTO) in patients with symptomatic varus malalignment of the mechanical leg axis. However, the precision of HTO can decrease with malpositioned PSI. This study investigates the influence of malpositioned PSI on axis correction, osteotomy, and implant placement. METHODS: With a mean three-dimensional (3D) model (0.8° varus), PSI-navigated HTOs were computer simulated. Two different guide designs, one with stabilising hooks and one without, were used. By adding rotational and translational offsets of different degrees, wrong placements of PSI were simulated. After 5° valgisation of the postoperative mechanical axis, the distance between joint-plane and osteotomy screws, respectively, were measured. The same simulations were performed in a patient with varus deformity (7.4° varus). RESULTS: In the mean 3D model, the postoperative mechanical axis was within 3.9°-4.5° valgus with mean value of 4.1° ± 0.1° (correct axis 4.2° valgus). Surgical failure concerning osteotomy occurred in 17 of 76 HTOs. Significantly safer screw placement was observed using PSI with stabilising hooks (p = 0.012). In the case of the 3D model with 7.4° varus deformity, the postoperative mechanical axis was within 3.2°-3.9° valgus with mean value of 3.8° ± 0.2° (correct axis 3.9° valgus). Surgical failure concerning osteotomy occurred in 3 of 38 HTOs. Screws were always within the safety distance. CONCLUSION: The clinical relevance of the presented study is that malpositioning of a PSI within the possible degrees of freedom does not have a relevant influence on the axis correction. The most vulnerable plane for surgical failure is the sagittal plane, wherefore the treating surgeon should verify correct guide placement to prevent surgical failure, particularly in this plane. LEVEL OF EVIDENCE: III.


Assuntos
Osteotomia/instrumentação , Osteotomia/métodos , Cirurgia Assistida por Computador/instrumentação , Cirurgia Assistida por Computador/métodos , Tíbia/cirurgia , Artroplastia do Joelho/instrumentação , Artroplastia do Joelho/métodos , Parafusos Ósseos , Simulação por Computador , Feminino , Humanos , Imageamento Tridimensional , Masculino , Pessoa de Meia-Idade , Osteoartrite do Joelho/cirurgia , Período Pós-Operatório
16.
Knee Surg Sports Traumatol Arthrosc ; 28(10): 3128-3134, 2020 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-31705148

RESUMO

PURPOSE: Flexion and rotation of the knee joint are supposed to alter the measurement of the mechanical leg axis on long leg radiographs. However, in patients with varus or valgus alignment it has not been systematically analyzed so far. The hypothesis is that measurement of the mechanical leg axis is more influenced by flexion and rotation in presence of varus or valgus alignment compared to patients with a straight coronal alignment. METHODS: 3D surface models of the lower extremities of seven individuals with varying degrees of coronal alignment were created based on CT data. The coronal alignment of the seven individuals captured the range between 9° varus and 9° valgus with equal steps of 3°. Combinations of internal and external rotations of 10°, 20°, and 30° with flexion of 5°, 10°, 15°, 20°, and 30° were simulated. The mechanical leg axis was measured for each combination as the antero-posterior (ap)-projected hip-knee-ankle (HKA-) angle. RESULTS: 294 simulations with all combinations of rotation and flexion were performed. Ranges of deviation of HKA never showed a critical deviation of more than 3° from median values. Deviations from baseline appeared normally distributed for all flexion and rotation combinations (p < 0.05) and the probability for a deviation from the mean mechanical leg axis of more than 3° was less than 0.03 for all combinations. Comparability of the models, therefore, could be assumed. CONCLUSION: Deviations in HKA-angle measurements, caused by rotation or flexion, does not vary relevantly through the range of coronal alignment of 9° varus to 9° valgus. As a clinical relevance, deviations in HKA-angle measurements can be considered as comparable in patients with different coronal alignment. LEVEL OF EVIDENCE: III.


Assuntos
Articulação do Tornozelo/diagnóstico por imagem , Mau Alinhamento Ósseo/diagnóstico por imagem , Articulação do Joelho/diagnóstico por imagem , Extremidade Inferior/diagnóstico por imagem , Tomografia Computadorizada por Raios X , Articulação do Tornozelo/fisiopatologia , Mau Alinhamento Ósseo/fisiopatologia , Humanos , Articulação do Joelho/fisiopatologia , Perna (Membro) , Extremidade Inferior/fisiopatologia , Radiografia , Amplitude de Movimento Articular
17.
Int Orthop ; 44(9): 1711-1717, 2020 09.
Artigo em Inglês | MEDLINE | ID: mdl-32055971

RESUMO

PURPOSE: Patellofemoral instability can be caused by tibial or femoral torsional deformity. Established surgical treatment options are rotational osteotomies, but the transfer from pre-operative planning to surgical execution can be challenging. Patient-specific instruments (PSI) are proofed to be helpful tools in realignment surgery. However, accuracy of PSI in femoral and tibial rotational osteotomies remains still unknown. Goal of the present study was to evaluate the accuracy of PSI in femoral and tibial rotational osteotomies in a patient population suffering from patellofemoral instability. METHODS: All patients that underwent femoral or tibial rotational osteotomy using PSI in case of patellofemoral instability from October 2015 until April 2019 in our clinic were included. Twelve knees with twelve supracondylar femoral and seven supratuberositary tibial rotational osteotomies could be included. Accuracy of the correction was assessed using pre- and post-operative CT scans based on conventional measurements and, in 3D, based on 3D bone models of the respective patients. RESULTS: CT measurements revealed an absolute difference between planned and achieved rotation of 4.8° ± 3.1° for femoral and 7.9° ± 3.7° for tibial rotational osteotomies without significant difference (p = 0.069). Regarding 3D assessment, a significant difference could be observed for the residual error between femoral and tibial rotational osteotomies in the 3D angle (p = 0.014) with a higher accuracy for the femoral side. CONCLUSION: The application of PSI for femoral and tibial rotational osteotomy is a safe surgical treatment option. Accuracy for femoral rotational osteotomies is higher compared with tibial rotational osteotomies using PSI.


Assuntos
Osteotomia , Tíbia , Fêmur/diagnóstico por imagem , Fêmur/cirurgia , Humanos , Joelho , Tíbia/diagnóstico por imagem , Tíbia/cirurgia , Tomografia Computadorizada por Raios X
18.
BMC Musculoskelet Disord ; 20(1): 496, 2019 Oct 27.
Artigo em Inglês | MEDLINE | ID: mdl-31656187

RESUMO

BACKGROUND: Several risk factors for adult acquired flatfoot deformity (AAFD) have been identified in literature. To this date, little attention has been paid to the lateral ligament complex and its influence on AAFD, although its anatomic course and anatomic studies suggest a restriction to flatfoot deformity. The aim of this study was to assess the influence of the anterior talofibular ligament (ATFL) on AAFD and on radiologic outcome following common operative correction by lateral calcaneal lengthening. METHODS: We reviewed all patients that underwent lateral calcaneal lengthening for correction of AAFD between January 2008 and July 2018 at our clinic. Patients were grouped according to the preoperative MRI findings into those with an intact ATFL and those with an injured ATFL. Two independent readers assessed common radiographic flatfoot parameters on preoperative and postoperative radiographs. RESULTS: Sixty-four flatfoot corrections in 63 patients were included, whereby the ATFL was intact in 29 cases, and in 35 cases the ligament was injured. An ATFL lesion was overall radiologically associated with increased flatfoot deformity with a statistically significant difference between the two groups for preoperative talometatarsal-angle (p = 0.002), talocalcaneal-angle (p = 0.000) and talonavicular uncoverage-angle (p = 0.005). No difference between the two groups could be observed regarding the success of operative correction or operative consistency after lateral calcaneal lengthening. CONCLUSION: The ATFL seems to influence the extent of AAFD. In patients undergoing lateral calcaneal lengthening, the integrity of the ligament seems not to influence the degree of correction or the consistency of the postoperative result.


Assuntos
Alongamento Ósseo/métodos , Calcâneo/cirurgia , Pé Chato/cirurgia , Ligamentos Laterais do Tornozelo/lesões , Osteotomia/métodos , Adulto , Calcâneo/diagnóstico por imagem , Feminino , Pé Chato/diagnóstico por imagem , Pé Chato/etiologia , Seguimentos , Humanos , Ligamentos Laterais do Tornozelo/diagnóstico por imagem , Imageamento por Ressonância Magnética , Masculino , Pessoa de Meia-Idade , Período Pré-Operatório , Radiografia , Estudos Retrospectivos , Fatores de Risco , Resultado do Tratamento
19.
Chemistry ; 23(14): 3406-3413, 2017 Mar 08.
Artigo em Inglês | MEDLINE | ID: mdl-27943429

RESUMO

We present an innovative O6 -tert-butyl/N2 -tert-butyloxycarbonyl protection concept for guanosine (G) phosphoramidites. This concept is advantageous for 2'-modified G building blocks because of very efficient synthetic access when compared with existing routes that usually employ O6 -(4-nitrophenyl)ethyl/N2 -acyl protection or that start from 2-aminoadenosine involving enzymatic transformation into guanosine later on in the synthetic path. The new phosphoramidites are fully compatible with 2'-O-tBDMS or TOM phosphoramidites in standard RNA solid-phase synthesis and deprotection, and provide excellent quality of tailored RNAs for the growing range of applications in RNA biophysics, biochemistry, and biology.


Assuntos
Guanosina/química , Compostos Organofosforados/química , RNA/síntese química , Ácidos/química , Adenosina/análogos & derivados , Adenosina/química , Sequência de Bases , Espectroscopia de Ressonância Magnética/métodos , Espectrometria de Massas/métodos , Nitrofenóis/química , Técnicas de Síntese em Fase Sólida
20.
Chemistry ; 21(29): 10400-7, 2015 Jul 13.
Artigo em Inglês | MEDLINE | ID: mdl-26074479

RESUMO

The 2'-trifluoromethylthio (2'-SCF3 ) modification endows ribonucleic acids with exceptional properties and has attracted considerable interest as a reporter group for NMR spectroscopic applications. However, only modified pyrimidine nucleosides have been generated so far. Here, the syntheses of 2'-SCF3 adenosine and guanosine phosphoramidites of which the latter was obtained in highly efficient manner by an unconventional Boc-protecting group strategy, are reported. RNA solid-phase synthesis provided site-specifically 2'-SCF3 -modified oligoribonucleotides that were investigated intensively. Their excellent behavior in (19) F NMR spectroscopic probing of RNA ligand binding was exemplified for a noncovalent small molecule-RNA interaction. Moreover, comparably to the 2'-SCF3 pyrimidine nucleosides, the purine counterparts were also found to cause a significant thermodynamic destabilization when located in double helical regions. This property was considered beneficial for siRNA design under the aspect to minimize off-target effects and their performance in silencing of the BASP1 gene was demonstrated.


Assuntos
Flúor/química , Oligonucleotídeos/química , Compostos Organofosforados/química , Purinas/química , RNA Interferente Pequeno/química , Cristalografia por Raios X , Ligantes , Espectroscopia de Ressonância Magnética , Oligonucleotídeos/metabolismo , RNA Interferente Pequeno/metabolismo , Técnicas de Síntese em Fase Sólida , Termodinâmica
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA