Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Mais filtros

Base de dados
Tipo de documento
Intervalo de ano de publicação
1.
Nat Commun ; 10(1): 1122, 2019 03 08.
Artigo em Inglês | MEDLINE | ID: mdl-30850597

RESUMO

State-of-the-art aerosol nanoparticle techniques all have one feature in common: for analysis they remove the nanoparticles from their original environment. Therefore, physical and chemical properties of the particles might be changed or cannot be measured correctly. To overcome these shortcomings, we apply synchrotron based small angle X-ray scattering (SAXS) as an in-situ measurement technique. Contrasting other aerosol studies using SAXS, we focus on particle concentrations which allow direct comparison to common aerosol nanoparticle analyzers. To this end, we analyze aerosol nanoparticles at ambient pressure and concentrations of slightly above ~106 cm-3. A differential mobility particle sizer (DMPS) is operated in parallel. We find that SAXS enables measurement of the primary particles and the aggregates, whereas the DMPS detects only aggregates. We conclude that in-situ nanoparticle characterization with ultra-low volume fractions of ~10-10 is feasible with SAXS. Our technique opens up a doorway to the in-situ analysis of aerosol nanoparticles under atmospheric conditions.

2.
Acta Anaesthesiol Scand ; 36(7): 621-7, 1992 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-1441861

RESUMO

The amounts of halothane and isoflurane trapped after exposure for up to 3 h at 2 MAC in commonly used anaesthesia circuit tubing were quantitated by gas chromatography. The decontaminating effects of procedures such as flushing with oxygen, thermal disinfection and/or routine storage were assessed in a similar way. After halothane exposure, anaesthetic content was highest in silicone (398 +/- 55 mg 100 g-1). Lower quantities were found in all other tubings investigated (electrically conductive latex: 64 +/- 4, conductive rubber: 62 +/- 4, polyethylene-vinyl-acetate (PEVA): 293 +/- 10 and 149 +/- 17 for non-conductive corrugated and spiral tubes, respectively, polysulfone (Hytrel): 155 +/- 10 mg 100 g-1). The isoflurane contents were substantially lower (silicone: 278 +/- 23; others: 55 +/- 7, 61 +/- 6, 163 +/- 9 and 86 +/- 8, 74 +/- 4 mg 100 g-1). The tubings' content did not correlate with the material's partition coefficient as full saturation was not achieved during exposure. Decontamination procedures reduced the content of volatile anaesthetics to a variable extent. Conductive latex and rubber showed the highest residual content, even after thermal disinfection and subsequent storage. Twenty-minute flushing with oxygen (8 l min-1) decreased effluent gas concentrations below 5 p.p.m. in all tubings. With silicone, after 1 h flushing, halothane concentrations still exceeded 10 p.p.m. (isoflurane: 8 p.p.m.). It is concluded that urgent decontamination by a 20-min flush warrants the safe re-use of previously 'contaminated' conductive rubber and latex as well as polysulfone tubings in critical situations, e.g. in malignant hyperthermia patients if disposable tubing is not immediately available.(ABSTRACT TRUNCATED AT 250 WORDS)


Assuntos
Anestesia por Inalação/instrumentação , Halotano/química , Isoflurano/química , Cromatografia Gasosa , Desinfecção , Segurança de Equipamentos , Halotano/administração & dosagem , Halotano/análise , Humanos , Intubação/instrumentação , Isoflurano/administração & dosagem , Isoflurano/análise , Oxigênio/química , Polímeros/análise , Polímeros/química , Polivinil/análise , Polivinil/química , Borracha/análise , Borracha/química , Elastômeros de Silicone/análise , Elastômeros de Silicone/química , Sulfonas/análise , Sulfonas/química , Propriedades de Superfície , Fatores de Tempo
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA