Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 90
Filtrar
1.
Nature ; 623(7985): 106-114, 2023 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-37880365

RESUMO

Maturation of the human fetal brain should follow precisely scheduled structural growth and folding of the cerebral cortex for optimal postnatal function1. We present a normative digital atlas of fetal brain maturation based on a prospective international cohort of healthy pregnant women2, selected using World Health Organization recommendations for growth standards3. Their fetuses were accurately dated in the first trimester, with satisfactory growth and neurodevelopment from early pregnancy to 2 years of age4,5. The atlas was produced using 1,059 optimal quality, three-dimensional ultrasound brain volumes from 899 of the fetuses and an automated analysis pipeline6-8. The atlas corresponds structurally to published magnetic resonance images9, but with finer anatomical details in deep grey matter. The between-study site variability represented less than 8.0% of the total variance of all brain measures, supporting pooling data from the eight study sites to produce patterns of normative maturation. We have thereby generated an average representation of each cerebral hemisphere between 14 and 31 weeks' gestation with quantification of intracranial volume variability and growth patterns. Emergent asymmetries were detectable from as early as 14 weeks, with peak asymmetries in regions associated with language development and functional lateralization between 20 and 26 weeks' gestation. These patterns were validated in 1,487 three-dimensional brain volumes from 1,295 different fetuses in the same cohort. We provide a unique spatiotemporal benchmark of fetal brain maturation from a large cohort with normative postnatal growth and neurodevelopment.


Assuntos
Encéfalo , Desenvolvimento Fetal , Feto , Pré-Escolar , Feminino , Humanos , Gravidez , Encéfalo/anatomia & histologia , Encéfalo/embriologia , Encéfalo/crescimento & desenvolvimento , Feto/embriologia , Idade Gestacional , Substância Cinzenta/anatomia & histologia , Substância Cinzenta/embriologia , Substância Cinzenta/crescimento & desenvolvimento , Voluntários Saudáveis , Internacionalidade , Imageamento por Ressonância Magnética , Tamanho do Órgão , Estudos Prospectivos , Organização Mundial da Saúde , Imageamento Tridimensional , Ultrassonografia
2.
Lancet ; 401(10389): 1692-1706, 2023 05 20.
Artigo em Inglês | MEDLINE | ID: mdl-37167991

RESUMO

Despite major achievements in child survival, the burden of neonatal mortality has remained high and even increased in some countries since 1990. Currently, most neonatal deaths are attributable to being born preterm, small for gestational age (SGA), or with low birthweight (LBW). Besides neonatal mortality, these conditions are associated with stillbirth and multiple morbidities, with short-term and long-term adverse consequences for the newborn, their families, and society, resulting in a major loss of human capital. Prevention of preterm birth, SGA, and LBW is thus critical for global child health and broader societal development. Progress has, however, been slow, largely because of the global community's failure to agree on the definition and magnitude of newborn vulnerability and best ways to address it, to frame the problem attractively, and to build a broad coalition of actors and a suitable governance structure to implement a change. We propose a new definition and a conceptual framework, bringing preterm birth, SGA, and LBW together under a broader umbrella term of the small vulnerable newborn (SVN). Adoption of the framework and the unified definition can facilitate improved problem definition and improved programming for SVN prevention. Interventions aiming at SVN prevention would result in a healthier start for live-born infants, while also reducing the number of stillbirths, improving maternal health, and contributing to a positive economic and social development in the society.


Assuntos
Nascimento Prematuro , Lactente , Gravidez , Criança , Feminino , Recém-Nascido , Humanos , Nascimento Prematuro/epidemiologia , Nascimento Prematuro/prevenção & controle , Recém-Nascido de Baixo Peso , Recém-Nascido Pequeno para a Idade Gestacional , Mortalidade Infantil , Natimorto/epidemiologia
3.
PLoS Med ; 20(7): e1004236, 2023 07.
Artigo em Inglês | MEDLINE | ID: mdl-37486938

RESUMO

BACKGROUND: Many women experience suboptimal gestational weight gain (GWG) in low- and middle-income countries (LMICs), but our understanding of risk factors associated with GWG in these settings is limited. We investigated the relationships between demographic, anthropometric, lifestyle, and clinical factors and GWG in prospectively collected data from LMICs. METHODS AND FINDINGS: We conducted an individual participant-level meta-analysis of risk factors for GWG outcomes among 138,286 pregnant women with singleton pregnancies in 55 studies (27 randomized controlled trials and 28 prospective cohorts from 25 LMICs). Data sources were identified through PubMed, Embase, and Web of Science searches for articles published from January 2000 to March 2019. Titles and abstracts of articles identified in all databases were independently screened by 2 team members according to the following eligibility criteria: following inclusion criteria: (1) GWG data collection took place in an LMIC; (2) the study was a prospective cohort or randomized trial; (3) study participants were pregnant; and (4) the study was not conducted exclusively among human immunodeficiency virus (HIV)-infected women or women with other health conditions that could limit the generalizability of the results. The Institute of Medicine (IOM) body mass index (BMI)-specific guidelines were used to determine the adequacy of GWG, which we calculated as the ratio of the total observed weight gain over the mean recommended weight gain. Study outcomes included severely inadequate GWG (percent adequacy of GWG <70), inadequate GWG (percent adequacy of GWG <90, inclusive of severely inadequate), and excessive GWG (percent adequacy of GWG >125). Multivariable estimates from each study were pooled using fixed-effects meta-analysis. Study-specific regression models for each risk factor included all other demographic risk factors measured in a particular study as potential confounders, as well as BMI, maternal height, pre-pregnancy smoking, and chronic hypertension. Risk factors occurring during pregnancy were further adjusted for receipt of study intervention (if any) and 3-month calendar period. The INTERGROWTH-21st standard was used to define high and low GWG among normal weight women in a sensitivity analysis. The prevalence of inadequate GWG was 54%, while the prevalence of excessive weight gain was 22%. In multivariable models, factors that were associated with a higher risk of inadequate GWG included short maternal stature (<145 cm), tobacco smoking, and HIV infection. A mid-upper arm circumference (MUAC) of ≥28.1 cm was associated with the largest increase in risk for excessive GWG (risk ratio (RR) 3.02, 95% confidence interval (CI) [2.86, 3.19]). The estimated pooled difference in absolute risk between those with MUAC of ≥28.1 cm compared to those with a MUAC of 24 to 28.09 cm was 5.8% (95% CI 3.1% to 8.4%). Higher levels of education and age <20 years were also associated with an increased risk of excessive GWG. Results using the INTERGROWTH-21st standard among normal weight women were similar but attenuated compared to the results using the IOM guidelines among normal weight women. Limitations of the study's methodology include differences in the availability of risk factors and potential confounders measured in each individual dataset; not all risk factors or potential confounders of interest were available across datasets and data on potential confounders collected across studies. CONCLUSIONS: Inadequate GWG is a significant public health concern in LMICs. We identified diverse nutritional, behavioral, and clinical risk factors for inadequate GWG, highlighting the need for integrated approaches to optimizing GWG in LMICs. The prevalence of excessive GWG suggests that attention to the emerging burden of excessive GWG in LMICs is also warranted.


Assuntos
Ganho de Peso na Gestação , Infecções por HIV , Humanos , Feminino , Gravidez , Adulto Jovem , Adulto , Países em Desenvolvimento , Estudos Prospectivos , Aumento de Peso , Fatores de Risco , Índice de Massa Corporal , Resultado da Gravidez/epidemiologia , Ensaios Clínicos Controlados Aleatórios como Assunto
4.
J Public Health (Oxf) ; 45(3): 738-747, 2023 08 28.
Artigo em Inglês | MEDLINE | ID: mdl-36585903

RESUMO

BACKGROUND: Observational studies relating maternal 25-hydroxyvitamin D status to timing and mode of delivery have reported inconsistent results. We assessed the effect of antenatal cholecalciferol supplementation on the incidence of preterm birth, delivery mode and post-partum haemorrhage (PPH). METHODS: MAVIDOS was a randomized, double-blind, placebo-controlled trial of 1000 IU/day cholecalciferol from 14 weeks' gestation until delivery. Gestational age, mode of delivery [categorized as spontaneous vaginal delivery (SVD), instrumental (including forceps and vacuum extraction) or Caesarean section] and PPH (>500 ml estimated blood loss) were determined from medical records. RESULTS: A total of 965 women participated in the study until delivery. Gestation at birth and incidence of preterm birth (cholecalciferol 5.7%, placebo 4.5%, P = 0.43) were similar between the two treatment groups. SVD (versus instrumental or Caesarean delivery) was more likely in women randomized to cholecalciferol [Relative Risk (RR) 1.13, 95% confidence interval (CI) 1.02,1.25] due to lower instrumental (RR 0.68, 95%CI 0.51,0.91) but similar risk of Caesarean delivery (RR 0.94, 95%CI 0.74,1.19). PPH was less common in women randomized to cholecalciferol [32.1% compared with placebo (38.1%, P = 0.054) overall], but similar when stratified by delivery mode. CONCLUSIONS: Antenatal cholecalciferol supplementation did not alter timing of birth or prevalence of preterm birth but demonstrated a possible effect on the likelihood of SVD.


Assuntos
Cesárea , Nascimento Prematuro , Gravidez , Feminino , Recém-Nascido , Humanos , Cesárea/efeitos adversos , Nascimento Prematuro/epidemiologia , Nascimento Prematuro/prevenção & controle , Colecalciferol/uso terapêutico , Parto Obstétrico , Suplementos Nutricionais
5.
PLoS Med ; 18(4): e1003611, 2021 04.
Artigo em Inglês | MEDLINE | ID: mdl-33905424

RESUMO

BACKGROUND: Gestational hypertensive and acute hypotensive disorders are associated with maternal morbidity and mortality worldwide. However, physiological blood pressure changes in pregnancy are insufficiently defined. We describe blood pressure changes across healthy pregnancies from the International Fetal and Newborn Growth Consortium for the 21st Century (INTERGROWTH-21st) Fetal Growth Longitudinal Study (FGLS) to produce international, gestational age-specific, smoothed centiles (third, 10th, 50th, 90th, and 97th) for blood pressure. METHODS AND FINDINGS: Secondary analysis of a prospective, longitudinal, observational cohort study (2009 to 2016) was conducted across 8 diverse urban areas in Brazil, China, India, Italy, Kenya, Oman, the United Kingdom, and the United States of America. We enrolled healthy women at low risk of pregnancy complications. We measured blood pressure using standardised methodology and validated equipment at enrolment at <14 weeks, then every 5 ± 1 weeks until delivery. We enrolled 4,607 (35%) women of 13,108 screened. The mean maternal age was 28·4 (standard deviation [SD] 3.9) years; 97% (4,204/4,321) of women were married or living with a partner, and 68% (2,955/4,321) were nulliparous. Their mean body mass index (BMI) was 23.3 (SD 3.0) kg/m2. Systolic blood pressure was lowest at 12 weeks: Median was 111.5 (95% CI 111.3 to 111.8) mmHg, rising to a median maximum of 119.6 (95% CI 118.9 to 120.3) mmHg at 40 weeks' gestation, a difference of 8.1 (95% CI 7.4 to 8.8) mmHg. Median diastolic blood pressure decreased from 12 weeks: 69.1 (95% CI 68.9 to 69.3) mmHg to a minimum of 68.5 (95% CI 68.3 to 68.7) mmHg at 19+5 weeks' gestation, a change of -0·6 (95% CI -0.8 to -0.4) mmHg. Diastolic blood pressure subsequently increased to a maximum of 76.3 (95% CI 75.9 to 76.8) mmHg at 40 weeks' gestation. Systolic blood pressure fell by >14 mmHg or diastolic blood pressure by >11 mmHg in fewer than 10% of women at any gestational age. Fewer than 10% of women increased their systolic blood pressure by >24 mmHg or diastolic blood pressure by >18 mmHg at any gestational age. The study's main limitations were the unavailability of prepregnancy blood pressure values and inability to explore circadian effects because time of day was not recorded for the blood pressure measurements. CONCLUSIONS: Our findings provide international, gestational age-specific centiles and limits of acceptable change to facilitate earlier recognition of deteriorating health in pregnant women. These centiles challenge the idea of a clinically significant midpregnancy drop in blood pressure.


Assuntos
Pressão Sanguínea/fisiologia , Desenvolvimento Fetal/fisiologia , Idade Gestacional , Adulto , Brasil , Pré-Escolar , China , Feminino , Humanos , Índia , Itália , Quênia , Estudos Longitudinais , Ultrassonografia Pré-Natal/métodos , Reino Unido , Adulto Jovem
6.
Am J Obstet Gynecol ; 224(2): 208.e1-208.e18, 2021 02.
Artigo em Inglês | MEDLINE | ID: mdl-32768431

RESUMO

BACKGROUND: Human growth is susceptible to damage from insults, particularly during periods of rapid growth. Identifying those periods and the normative limits that are compatible with adequate growth and development are the first key steps toward preventing impaired growth. OBJECTIVE: This study aimed to construct international fetal growth velocity increment and conditional velocity standards from 14 to 40 weeks' gestation based on the same cohort that contributed to the INTERGROWTH-21st Fetal Growth Standards. STUDY DESIGN: This study was a prospective, longitudinal study of 4321 low-risk pregnancies from 8 geographically diverse populations in the INTERGROWTH-21st Project with rigorous standardization of all study procedures, equipment, and measurements that were performed by trained ultrasonographers. Gestational age was accurately determined clinically and confirmed by ultrasound measurement of crown-rump length at <14 weeks' gestation. Thereafter, the ultrasonographers, who were masked to the values, measured the fetal head circumference, biparietal diameter, occipitofrontal diameter, abdominal circumference, and femur length in triplicate every 5 weeks (within 1 week either side) using identical ultrasound equipment at each site (4-7 scans per pregnancy). Velocity increments across a range of intervals between measures were modeled using fractional polynomial regression. RESULTS: Peak velocity was observed at a similar gestational age: 16 and 17 weeks' gestation for head circumference (12.2 mm/wk), and 16 weeks' gestation for abdominal circumference (11.8 mm/wk) and femur length (3.2 mm/wk). However, velocity growth slowed down rapidly for head circumference, biparietal diameter, occipitofrontal diameter, and femur length, with an almost linear reduction toward term that was more marked for femur length. Conversely, abdominal circumference velocity remained relatively steady throughout pregnancy. The change in velocity with gestational age was more evident for head circumference, biparietal diameter, occipitofrontal diameter, and femur length than for abdominal circumference when the change was expressed as a percentage of fetal size at 40 weeks' gestation. We have also shown how to obtain accurate conditional fetal velocity based on our previous methodological work. CONCLUSION: The fetal skeleton and abdomen have different velocity growth patterns during intrauterine life. Accordingly, we have produced international Fetal Growth Velocity Increment Standards to complement the INTERGROWTH-21st Fetal Growth Standards so as to monitor fetal well-being comprehensively worldwide. Fetal growth velocity curves may be valuable if one wants to study the pathophysiology of fetal growth. We provide an application that can be used easily in clinical practice to evaluate changes in fetal size as conditional velocity for a more refined assessment of fetal growth than is possible at present (https://lxiao5.shinyapps.io/fetal_growth/). The application is freely available with the other INTERGROWTH-21st tools at https://intergrowth21.tghn.org/standards-tools/.


Assuntos
Abdome/embriologia , Fêmur/embriologia , Desenvolvimento Fetal , Idade Gestacional , Cabeça/embriologia , Abdome/diagnóstico por imagem , Adulto , Estatura Cabeça-Cóccix , Feminino , Fêmur/diagnóstico por imagem , Gráficos de Crescimento , Cabeça/diagnóstico por imagem , Humanos , Recém-Nascido , Internacionalidade , Estudos Longitudinais , Masculino , Gravidez , Ultrassonografia Pré-Natal , Adulto Jovem
7.
Am J Obstet Gynecol ; 222(6): 602.e1-602.e15, 2020 06.
Artigo em Inglês | MEDLINE | ID: mdl-31954701

RESUMO

BACKGROUND: Reference values for umbilical artery Doppler indices are used clinically to assess fetal well-being. However, many studies that have produced reference charts have important methodologic limitations, and these result in significant heterogeneity of reported reference ranges. OBJECTIVES: To produce international gestational age-specific centiles for umbilical artery Doppler indices based on longitudinal data and the same rigorous methodology used in the original Fetal Growth Longitudinal Study of the INTERGROWTH-21st Project. STUDY DESIGN: In Phase II of the INTERGROWTH-21st Project (the INTERBIO-21st Study), we prospectively continued enrolling pregnant women according to the same protocol from 3 of the original populations in Pelotas (Brazil), Nairobi (Kenya), and Oxford (United Kingdom) that had participated in the Fetal Growth Longitudinal Study. Women with a singleton pregnancy were recruited at <14 weeks' gestation, confirmed by ultrasound measurement of crown-rump length, and then underwent standardized ultrasound every 5±1 weeks until delivery. From 22 weeks of gestation umbilical artery indices (pulsatility index, resistance index, and systolic/diastolic ratio) were measured in a blinded fashion, using identical equipment and a rigorously standardized protocol. Newborn size at birth was assessed using the international INTERGROWTH-21st Standards, and infants had detailed assessment of growth, nutrition, morbidity, and motor development at 1 and 2 years of age. The appropriateness of pooling data from the 3 study sites was assessed using variance component analysis and standardized site differences. Umbilical artery indices were modeled as functions of the gestational age using an exponential, normal distribution with second-degree fractional polynomial smoothing; goodness of fit for the overall models was assessed. RESULTS: Of the women enrolled at the 3 sites, 1629 were eligible for this study; 431 (27%) met the entry criteria for the construction of normative centiles, similar to the proportion seen in the original fetal growth longitudinal study. They contributed a total of 1243 Doppler measures to the analysis; 74% had 3 measures or more. The healthy low-risk status of the population was confirmed by the low rates of preterm birth (4.9%) and preeclampsia (0.7%). There were no neonatal deaths and satisfactory growth, health, and motor development of the infants at 1 and 2 years of age were documented. Only a very small proportion (2.8%-6.5%) of the variance of Doppler indices was due to between-site differences; in addition, standardized site difference estimates were marginally outside this threshold in only 1 of 27 comparisons, and this supported the decision to pool data from the 3 study sites. All 3 Doppler indices decreased with advancing gestational age. The 3rd, 5th 10th, 50th, 90th, 95th, and 97th centiles according to gestational age for each of the 3 indices are provided, as well as equations to allow calculation of any value as a centile and z scores. The mean pulsatility index according to gestational age = 1.02944 + 77.7456*(gestational age)-2 - 0.000004455*gestational age3. CONCLUSION: We present here international gestational age-specific normative centiles for umbilical artery Doppler indices produced by studying healthy, low-risk pregnant women living in environments with minimal constraints on fetal growth. The centiles complement the existing INTERGROWTH-21st Standards for assessment of fetal well-being.


Assuntos
Velocidade do Fluxo Sanguíneo/fisiologia , Idade Gestacional , Artérias Umbilicais/diagnóstico por imagem , Resistência Vascular/fisiologia , Adulto , Brasil , Desenvolvimento Infantil , Estudos de Coortes , Diástole , Feminino , Desenvolvimento Fetal , Humanos , Lactente , Recém-Nascido , Quênia , Estudos Longitudinais , Masculino , Gravidez , Segundo Trimestre da Gravidez , Terceiro Trimestre da Gravidez , Estudos Prospectivos , Valores de Referência , Sístole , Ultrassonografia Doppler em Cores , Ultrassonografia Doppler de Pulso , Ultrassonografia Pré-Natal , Artérias Umbilicais/fisiologia , Reino Unido , Adulto Jovem
8.
Curr Hypertens Rep ; 22(1): 10, 2020 02 01.
Artigo em Inglês | MEDLINE | ID: mdl-32008117

RESUMO

PURPOSE OF REVIEW: This review discusses the mortality and morbidity of hypertensive disorders of pregnancy (HDP) and the current diagnostic thresholds. It then explores measurement of variability in blood pressure (BP) during pregnancy as an opportunity to identify women at high risk of cardiovascular disease (CVD) later in life. RECENT FINDINGS: HDP is known to be associated with increased risk of long-term CVD. Current CVD prognostic tools do not incorporate a history of HDP given a lack of improved risk discrimination. However, HDP diagnostic criteria are currently based on a binary threshold, and there is some evidence for the use of variability in BP throughout gestation as a marker of CVD risk. HDP increases long-term risk of CVD. Future studies investigating changes in diagnostic criteria, including the use of BP variability, may improve long-term CVD risk prediction and be incorporated into future risk assessment tools.


Assuntos
Pressão Sanguínea , Hipertensão Induzida pela Gravidez , Feminino , Humanos , Hipertensão Induzida pela Gravidez/diagnóstico , Gravidez , Prognóstico , Medição de Risco , Fatores de Risco
9.
Euro Surveill ; 25(42)2020 10.
Artigo em Inglês | MEDLINE | ID: mdl-33094717

RESUMO

SARS-CoV-2 IgG screening of 1,000 antenatal serum samples in the Oxford area, United Kingdom, between 14 April and 15 June 2020, yielded a 5.3% seroprevalence, mirroring contemporaneous regional data. Among the 53 positive samples, 39 showed in vitro neutralisation activity, correlating with IgG titre (Pearson's correlation p<0.0001). While SARS-CoV-2 seroprevalence in pregnancy cohorts could potentially inform population surveillance, clinical correlates of infection and immunity in pregnancy, and antenatal epidemiology evolution over time need further study.


Assuntos
Anticorpos Neutralizantes/sangue , Anticorpos Antivirais/sangue , Betacoronavirus/imunologia , Infecções por Coronavirus/epidemiologia , Imunoglobulina G/sangue , Pandemias , Pneumonia Viral/epidemiologia , Vigilância da População , Complicações Infecciosas na Gravidez/sangue , Primeiro Trimestre da Gravidez/sangue , Adolescente , Adulto , COVID-19 , Estudos de Coortes , Infecções por Coronavirus/sangue , Inglaterra/epidemiologia , Ensaio de Imunoadsorção Enzimática , Feminino , Humanos , Pessoa de Meia-Idade , Pneumonia Viral/sangue , Gravidez , Diagnóstico Pré-Natal , Prevalência , SARS-CoV-2 , Estudos Soroepidemiológicos , Método Simples-Cego , Adulto Jovem
10.
Am J Obstet Gynecol ; 218(2S): S630-S640, 2018 02.
Artigo em Inglês | MEDLINE | ID: mdl-29422205

RESUMO

The purpose of the INTERGROWTH-21st project was to develop international, prescriptive standards for fetal growth assessed by ultrasound and fundal height, preterm postnatal growth, newborn size and body composition, maternal weight gain, and infant development at the age of 2 years. Hence, we have produced, based on World Health Organization recommendations, the first comprehensive set of international standards of optimal fetal and newborn growth that perfectly match the existing World Health Organization child growth standards. Uniquely, the same population was followed up longitudinally from 9 weeks of fetal life to 2 years of age, with growth, health, and nutritional status assessment at 2 years supporting the appropriateness of the population for construction of growth standards. The resulting package of clinical tools allows, for the first time, growth and development to be monitored from early pregnancy to infancy. The INTERGROWTH-21st fetal growth standards, which are based on observing >4500 healthy pregnancies, nested in a study of >59,000 pregnancies from populations with low rates of adverse perinatal outcomes, show how fetuses should grow-rather than the more limited objective of past references, which describe how they have grown at specific times and locations. Our work has confirmed the fundamental biological principle that variation in human growth across different populations is mostly dependent on environmental, nutritional, and socioeconomic factors. We found that when mothers' nutritional and health needs are met and there are few environmental constraints on growth, <3.5% of the total variability of skeletal growth was due to differences between populations. We propose that not recognizing the concept of optimal growth could deprive the most vulnerable mothers and their babies of optimal care, because local growth charts normalize those at highest risk for growth restriction and overweight, and can be valuable for policymakers to ensure rigorous evaluation and effective resource allocation. We strongly encourage colleagues to join efforts to provide integrated, evidence-based growth monitoring to pregnant women and their infants worldwide. Presently, there are 23.3 million infants born small for gestational age in low- to middle-income countries according to the INTERGROWTH-21st newborn size standards. We suggest that misclassification of these infants by using local charts could affect the delivery of optimal health care.


Assuntos
Desenvolvimento Infantil , Desenvolvimento Fetal , Ganho de Peso na Gestação , Gráficos de Crescimento , Adulto , Composição Corporal , Cefalometria , Estatura Cabeça-Cóccix , Feminino , Humanos , Lactente , Recém-Nascido , Recém-Nascido Prematuro , Recém-Nascido Pequeno para a Idade Gestacional , Gravidez , Valores de Referência , Ultrassonografia Pré-Natal , Útero , Organização Mundial da Saúde
11.
Am J Obstet Gynecol ; 218(2S): S841-S854.e2, 2018 02.
Artigo em Inglês | MEDLINE | ID: mdl-29273309

RESUMO

BACKGROUND: The World Health Organization recommends that human growth should be monitored with the use of international standards. However, in obstetric practice, we continue to monitor fetal growth using numerous local charts or equations that are based on different populations for each body structure. Consistent with World Health Organization recommendations, the INTERGROWTH-21st Project has produced the first set of international standards to date pregnancies; to monitor fetal growth, estimated fetal weight, Doppler measures, and brain structures; to measure uterine growth, maternal nutrition, newborn infant size, and body composition; and to assess the postnatal growth of preterm babies. All these standards are based on the same healthy pregnancy cohort. Recognizing the importance of demonstrating that, postnatally, this cohort still adhered to the World Health Organization prescriptive approach, we followed their growth and development to the key milestone of 2 years of age. OBJECTIVE: The purpose of this study was to determine whether the babies in the INTERGROWTH-21st Project maintained optimal growth and development in childhood. STUDY DESIGN: In the Infant Follow-up Study of the INTERGROWTH-21st Project, we evaluated postnatal growth, nutrition, morbidity, and motor development up to 2 years of age in the children who contributed data to the construction of the international fetal growth, newborn infant size and body composition at birth, and preterm postnatal growth standards. Clinical care, feeding practices, anthropometric measures, and assessment of morbidity were standardized across study sites and documented at 1 and 2 years of age. Weight, length, and head circumference age- and sex-specific z-scores and percentiles and motor development milestones were estimated with the use of the World Health Organization Child Growth Standards and World Health Organization milestone distributions, respectively. For the preterm infants, corrected age was used. Variance components analysis was used to estimate the percentage variability among individuals within a study site compared with that among study sites. RESULTS: There were 3711 eligible singleton live births; 3042 children (82%) were evaluated at 2 years of age. There were no substantive differences between the included group and the lost-to-follow up group. Infant mortality rate was 3 per 1000; neonatal mortality rate was 1.6 per 1000. At the 2-year visit, the children included in the INTERGROWTH-21st Fetal Growth Standards were at the 49th percentile for length, 50th percentile for head circumference, and 58th percentile for weight of the World Health Organization Child Growth Standards. Similar results were seen for the preterm subgroup that was included in the INTERGROWTH-21st Preterm Postnatal Growth Standards. The cohort overlapped between the 3rd and 97th percentiles of the World Health Organization motor development milestones. We estimated that the variance among study sites explains only 5.5% of the total variability in the length of the children between birth and 2 years of age, although the variance among individuals within a study site explains 42.9% (ie, 8 times the amount explained by the variation among sites). An increase of 8.9 cm in adult height over mean parental height is estimated to occur in the cohort from low-middle income countries, provided that children continue to have adequate health, environmental, and nutritional conditions. CONCLUSION: The cohort enrolled in the INTERGROWTH-21st standards remained healthy with adequate growth and motor development up to 2 years of age, which supports its appropriateness for the construction of international fetal and preterm postnatal growth standards.


Assuntos
Desenvolvimento Infantil , Desenvolvimento Fetal , Gráficos de Crescimento , Nível de Saúde , Destreza Motora , Estado Nutricional , Brasil , Cefalometria , China , Feminino , Humanos , Índia , Lactente , Recém-Nascido , Itália , Quênia , Estudos Longitudinais , Masculino , Omã , Gravidez , Reino Unido , Estados Unidos , Organização Mundial da Saúde
12.
Pediatr Res ; 82(2): 305-316, 2017 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-28445454

RESUMO

BackgroundWe aimed to describe newborn body composition and identify which anthropometric ratio (weight/length; BMI; or ponderal index, PI) best predicts fat mass (FM) and fat-free mass (FFM).MethodsAir-displacement plethysmography (PEA POD) was used to estimate FM, FFM, and body fat percentage (BF%). Associations between FFM, FM, and BF% and weight/length, BMI, and PI were evaluated in 1,019 newborns using multivariate regression analysis. Charts for FM, FFM, and BF% were generated using a prescriptive subsample (n=247). Standards for the best-predicting anthropometric ratio were calculated utilizing the same population used for the INTERGROWTH-21st Newborn Size Standards (n=20,479).ResultsFFM and FM increased consistently during late pregnancy. Differential FM, BF%, and FFM patterns were observed for those born preterm (34+0-36+6 weeks' gestation) and with impaired intrauterine growth. Weight/length by gestational age (GA) was a better predictor of FFM and FM (adjusted R2=0.92 and 0.71, respectively) than BMI or PI, independent of sex, GA, and timing of measurement. Results were almost identical when only preterm newborns were studied. We present sex-specific centiles for weight/length ratio for GA.ConclusionsWeight/length best predicts newborn FFM and FM. There are differential FM, FFM, and BF% patterns by sex, GA, and size at birth.


Assuntos
Antropometria , Composição Corporal , Adulto , Feminino , Crescimento , Humanos , Recém-Nascido , Masculino , Gravidez
13.
Lancet ; 384(9946): 857-68, 2014 Sep 06.
Artigo em Inglês | MEDLINE | ID: mdl-25209487

RESUMO

BACKGROUND: In 2006, WHO published international growth standards for children younger than 5 years, which are now accepted worldwide. In the INTERGROWTH-21(st) Project, our aim was to complement them by developing international standards for fetuses, newborn infants, and the postnatal growth period of preterm infants. METHODS: INTERGROWTH-21(st) is a population-based project that assessed fetal growth and newborn size in eight geographically defined urban populations. These groups were selected because most of the health and nutrition needs of mothers were met, adequate antenatal care was provided, and there were no major environmental constraints on growth. As part of the Newborn Cross-Sectional Study (NCSS), a component of INTERGROWTH-21(st) Project, we measured weight, length, and head circumference in all newborn infants, in addition to collecting data prospectively for pregnancy and the perinatal period. To construct the newborn standards, we selected all pregnancies in women meeting (in addition to the underlying population characteristics) strict individual eligibility criteria for a population at low risk of impaired fetal growth (labelled the NCSS prescriptive subpopulation). Women had a reliable ultrasound estimate of gestational age using crown-rump length before 14 weeks of gestation or biparietal diameter if antenatal care started between 14 weeks and 24 weeks or less of gestation. Newborn anthropometric measures were obtained within 12 h of birth by identically trained anthropometric teams using the same equipment at all sites. Fractional polynomials assuming a skewed t distribution were used to estimate the fitted centiles. FINDINGS: We identified 20,486 (35%) eligible women from the 59,137 pregnant women enrolled in NCSS between May 14, 2009, and Aug 2, 2013. We calculated sex-specific observed and smoothed centiles for weight, length, and head circumference for gestational age at birth. The observed and smoothed centiles were almost identical. We present the 3rd, 10th, 50th, 90th, and 97th centile curves according to gestational age and sex. INTERPRETATION: We have developed, for routine clinical practice, international anthropometric standards to assess newborn size that are intended to complement the WHO Child Growth Standards and allow comparisons across multiethnic populations. FUNDING: Bill & Melinda Gates Foundation.


Assuntos
Antropometria/métodos , Peso ao Nascer/fisiologia , Desenvolvimento Fetal/fisiologia , Idade Gestacional , Recém-Nascido Prematuro/fisiologia , Adolescente , Adulto , Estatura/fisiologia , Cefalometria/normas , Estudos Transversais , Feminino , Humanos , Recém-Nascido , Masculino , Idade Materna , Gravidez , Estudos Prospectivos , Padrões de Referência , Caracteres Sexuais , Adulto Jovem
14.
Lancet ; 384(9946): 869-79, 2014 Sep 06.
Artigo em Inglês | MEDLINE | ID: mdl-25209488

RESUMO

BACKGROUND: In 2006, WHO produced international growth standards for infants and children up to age 5 years on the basis of recommendations from a WHO expert committee. Using the same methods and conceptual approach, the Fetal Growth Longitudinal Study (FGLS), part of the INTERGROWTH-21(st) Project, aimed to develop international growth and size standards for fetuses. METHODS: The multicentre, population-based FGLS assessed fetal growth in geographically defined urban populations in eight countries, in which most of the health and nutritional needs of mothers were met and adequate antenatal care was provided. We used ultrasound to take fetal anthropometric measurements prospectively from 14 weeks and 0 days of gestation until birth in a cohort of women with adequate health and nutritional status who were at low risk of intrauterine growth restriction. All women had a reliable estimate of gestational age confirmed by ultrasound measurement of fetal crown-rump length in the first trimester. The five primary ultrasound measures of fetal growth--head circumference, biparietal diameter, occipitofrontal diameter, abdominal circumference, and femur length--were obtained every 5 weeks (within 1 week either side) from 14 weeks to 42 weeks of gestation. The best fitting curves for the five measures were selected using second-degree fractional polynomials and further modelled in a multilevel framework to account for the longitudinal design of the study. FINDINGS: We screened 13,108 women commencing antenatal care at less than 14 weeks and 0 days of gestation, of whom 4607 (35%) were eligible. 4321 (94%) eligible women had pregnancies without major complications and delivered live singletons without congenital malformations (the analysis population). We documented very low maternal and perinatal mortality and morbidity, confirming that the participants were at low risk of adverse outcomes. For each of the five fetal growth measures, the mean differences between the observed and smoothed centiles for the 3rd, 50th, and 97th centiles, respectively, were small: 2·25 mm (SD 3·0), 0·02 mm (3·0), and -2·69 mm (3·2) for head circumference; 0·83 mm (0·9), -0·05 mm (0·8), and -0·84 mm (1·0) for biparietal diameter; 0·63 mm (1·2), 0·04 mm (1·1), and -1·05 mm (1·3) for occipitofrontal diameter; 2·99 mm (3·1), 0·25 mm (3·2), and -4·22 mm (3·7) for abdominal circumference; and 0·62 mm (0·8), 0·03 mm (0·8), and -0·65 mm (0·8) for femur length. We calculated the 3rd, 5th 10th, 50th, 90th, 95th and 97th centile curves according to gestational age for these ultrasound measures, representing the international standards for fetal growth. INTERPRETATION: We recommend these international fetal growth standards for the clinical interpretation of routinely taken ultrasound measurements and for comparisons across populations. FUNDING: Bill & Melinda Gates Foundation.


Assuntos
Desenvolvimento Fetal/fisiologia , Abdome/embriologia , Abdome/fisiologia , Adolescente , Adulto , Cefalometria/métodos , Feminino , Fêmur/embriologia , Humanos , Idade Materna , Gravidez , Estudos Prospectivos , Padrões de Referência , Ultrassonografia Pré-Natal/normas , Saúde da População Urbana , Adulto Jovem
15.
Am J Obstet Gynecol ; 213(4): 494-9, 2015 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-26184778

RESUMO

A comprehensive set of fully integrated anthropometric measures is needed to evaluate human growth from conception to infancy so that consistent judgments can be made about the appropriateness of fetal and infant growth. At present, there are 2 barriers to this strategy. First, descriptive reference charts, which are derived from local, unselected samples with inadequate methods and poor characterization of their putatively healthy populations, commonly are used rather than prescriptive standards. The use of prescriptive standards is justified by the extensive biologic, genetic, and epidemiologic evidence that skeletal growth is similar from conception to childhood across geographic populations, when health, nutrition, environmental, and health care needs are met. Second, clinicians currently screen fetuses, newborn infants, and infants at all levels of care with a wide range of charts and cutoff points, often with limited appreciation of the underlying population or quality of the study that generated the charts. Adding to the confusion, infants are evaluated after birth with a single prescriptive tool: the World Health Organization Child Growth Standards, which were derived from healthy, breastfed newborn infants, infants, and young children from populations that have been exposed to few growth-restricting factors. The International Fetal and Newborn Growth Consortium for the 21st Century Project addressed these issues by providing international standards for gestational age estimation, first-trimester fetal size, fetal growth, newborn size for gestational age, and postnatal growth of preterm infants, all of which complement the World Health Organization Child Growth Standards conceptually, methodologically, and analytically. Hence, growth and development can now, for the first time, be monitored globally across the vital first 1000 days and all the way to 5 years of age. It is clear that an integrative approach to monitoring growth and development from pregnancy to school age is desirable, scientifically supported, and likely to improve care, referral patterns, and reporting systems. Such integration can be achieved only through the use of international growth standards, especially in increasingly diverse, mixed ancestry populations. Resistance to new scientific developments has been hugely problematic in medicine; however, we are confident that the obstetric and neonatal communities will join their pediatric colleagues worldwide in the adoption of this integrative strategy.


Assuntos
Antropometria/métodos , Desenvolvimento Infantil , Desenvolvimento Fetal , Idade Gestacional , Desenvolvimento Ósseo , Criança , Pré-Escolar , Continuidade da Assistência ao Paciente , Feminino , Gráficos de Crescimento , Humanos , Lactente , Recém-Nascido , Masculino , Gravidez , Valores de Referência
16.
BMC Pregnancy Childbirth ; 15: 127, 2015 May 29.
Artigo em Inglês | MEDLINE | ID: mdl-26021564

RESUMO

BACKGROUND: Antenatal care early in pregnancy enables service providers to identify and manage risks to mother and fetus. In the global north, ultrasound scans are routinely offered in pregnancy to provide an accurate estimate of gestational age and identify potential problems. In sub-Saharan Africa, such services are rarely available and women often delay initiating antenatal care. This study describes the uptake and provision of antenatal care in a rural Kenyan hospital and explores how pregnant women and healthcare providers perceived the provision of ultrasound scanning, following its introduction in an international foetal growth study. METHODS: A descriptive study, using qualitative and quantitative methods, was conducted in Kilifi District Hospital, Kenya, between June 2011 and April 2012. In-depth interviews were conducted with 10 nurses working in the antenatal clinic (ANC) and 59 pregnant women attending ANC. Structured observations of 357 ANC consultations and 30 ultrasound scans were made. RESULTS: Women sought antenatal care for information about the health of their baby and the protection provided by the ANC services. Uncertainty about pregnancy status contributed to delay in ANC attendance; more than 78 % of women were over 20 weeks' gestation at their first visit. Healthcare workers found it difficult to detect pregnancies below 16 weeks gestation and, accurate assessment of gestational age below 20 weeks' gestation could be problematic. Provision of services depended on the pregnancy being detected and gestational age assessed. The "seeing", made possible through ultrasound scanning was perceived by pregnant women and healthcare workers to be beneficial: confirming the pregnancy, and providing reassurance about the fetus' condition. Few participants raised concerns about ultrasound scanning. CONCLUSIONS: Uncertainty about pregnancy status and gestational age for women and healthcare providers is a key factor influencing timing of ANC attendance, contributing to delays and restricting early provision of ANC services. Ultrasound scanning was perceived to enhance antenatal care through confirmation of pregnancy status and enabling more accurate estimation of gestational age and the health status of the fetus. There is a need to make available more affordable means of pregnancy testing as a strategy towards encouraging early attendance, and delivery of antenatal care.


Assuntos
Cuidado Pré-Natal/psicologia , Ultrassonografia Pré-Natal/psicologia , Adulto , Feminino , Conhecimentos, Atitudes e Prática em Saúde , Humanos , Quênia , Aceitação pelo Paciente de Cuidados de Saúde , Percepção , Gravidez , Pesquisa Qualitativa , População Rural
17.
Acta Paediatr ; 104(10): 987-96, 2015 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-26154879

RESUMO

UNLABELLED: Babies all over the world are assessed at birth using neonatal anthropometric charts as a matter of clinical routine. This systematic review evaluated the methodological quality of studies designed to create neonatal anthropometric charts and to highlight features in the charts that could affect clinical decision-making and comparisons between populations. The variety and quality of available charts could affect how newborns at risk are identified, together with the indications for treatment, especially nutritional interventions. CONCLUSION: The studies that generated the charts currently recommended for clinical use have major methodological limitations and international and regional comparisons are very difficult.


Assuntos
Antropometria , Gráficos de Crescimento , Recém-Nascido , Humanos
18.
Clin Perinatol ; 51(2): 475-495, 2024 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-38705653

RESUMO

Preterm birth (PTB) is a complex syndrome traditionally defined by a single parameter, namely, gestational age at birth (ie, ˂37 weeks). This approach has limitations for clinical usefulness and may explain the lack of progress in identifying cause-specific effective interventions. The authors offer a framework for a functional taxonomy of PTB based on (1) conceptual principles established a priori; (2) known etiologic factors; (3) specific, prospectively identified obstetric and neonatal clinical phenotypes; and (4) postnatal follow-up of growth and development up to 2 years of age. This taxonomy includes maternal, placental, and fetal conditions routinely recorded in data collection systems.


Assuntos
Nascimento Prematuro , Humanos , Feminino , Gravidez , Recém-Nascido , Idade Gestacional , Recém-Nascido Prematuro , Síndrome , Fatores de Risco , Ruptura Prematura de Membranas Fetais
19.
Hum Reprod Update ; 30(2): 186-214, 2024 Mar 01.
Artigo em Inglês | MEDLINE | ID: mdl-38007607

RESUMO

BACKGROUND: The Endometriosis Health Profiles (EHPs), the EHP-30 and EHP-5, are patient-reported outcome measures that were developed to measure the health-related quality of life (HRQoL) of women living with endometriosis. Prior to their development, a systematic review was undertaken which identified that the HRQoL of women living with endometriosis was poorly understood, with only three medical and one surgical study identified. OBJECTIVE AND RATIONALE: The 20-year anniversary of the EHP-30 provided a timely opportunity to assess how the tools have been used and explore what the findings tell us about the impact of endometriosis and its associated treatments upon women's QoL. Applying robust systematic review methodology, following PRISMA guidelines, we sought to answer: How many studies have used the EHP and for what purpose?; What are the demographic characteristics and international context of the studies?; What is the methodological nature and quality of the studies?; Which interventions have been assessed and what are the reported EHP outcomes?; and Can the EHP outcomes of these interventions be analysed using a meta-analysis and, if so, what do the results show? SEARCH METHODS: The electronic databases MEDLINE, CINAHL, PsycINFO, PubMed, and Google Scholar were searched from the year the EHP was first published, in 2001 to 26 February 2020 using the search terms 'EHP30', 'EHP5', 'EHP-30', 'EHP-5', 'endometriosis health profile 30', and 'endometriosis health profile 5'. We updated the searches on 9 April 2021. All included studies were quality assessed using the Mixed Methods Appraisal Tool (MMAT). OUTCOMES: The review included 139 papers. In clinical intervention studies, the EHPs were deployed most frequently to measure the outcomes of medical (n = 35) and surgical (n = 21) treatment. The EHPs were also used in 13 other intervention studies, 29 non-interventional studies, 32 psychometric/cross cultural validation studies; six diagnostic studies, and in three other studies to measure outcomes in related conditions. They were mainly deployed in studies undertaken in Europe and North America. Overall, regardless of the nature of the intervention, most women reported improvements in HRQoL after treatment. Surgical interventions generally resulted in significant improvements for the longest amount of time. There was also evidence that when participants stopped taking medication their EHP scores worsened, perhaps reinforcing the temporary impact of medical treatment. Younger patients reported more negative impact upon their HRQoL. Further evidence using classical test theory to support the EHPs' robust psychometric properties, including acceptability, dimensionality, reliability, validity (including cross-cultural), and responsiveness, was demonstrated, particularly for the EHP-30. Strikingly, using anchor-based methods, EHP-30 responsiveness studies demonstrate the largest mean changes in the 'control and powerlessness' domain post-intervention, followed by 'pain'. MMAT outcomes indicated the quality of the papers was good, with the exception of five studies. A meta-analysis was not undertaken owing to the heterogeneity of the interventions and papers included in this review. WIDER IMPLICATIONS: Women with endometriosis face a lifetime of surgical and/or medical interventions to keep the condition under control. Less invasive treatments that can lead to improved longer term physical and psycho-social outcomes are needed. The EHPs are reliable, valid, acceptable, and responsive tools, but more assessment of EHP outcomes using modern psychometric methods and in the context of women from ethnically diverse backgrounds and in routine clinical care would be beneficial. Given the brevity of the EHP-5, it may be the most appropriate version to use in routine clinical practice, whereas the longer EHP-30, which provides more granularity, is more appropriate for research.


Assuntos
Endometriose , Feminino , Humanos , Endometriose/complicações , Endometriose/terapia , Qualidade de Vida , Reprodutibilidade dos Testes
20.
J Matern Fetal Neonatal Med ; 37(1): 2333923, 2024 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-38584143

RESUMO

OBJECTIVE: To validate a serum biomarker developed in the USA for preterm birth (PTB) risk stratification in Viet Nam. METHODS: Women with singleton pregnancies (n = 5000) were recruited between 19+0-23+6 weeks' gestation at Tu Du Hospital, Ho Chi Minh City. Maternal serum was collected from 19+0-22+6 weeks' gestation and participants followed to neonatal discharge. Relative insulin-like growth factor binding protein 4 (IGFBP4) and sex hormone binding globulin (SHBG) abundances were measured by mass spectrometry and their ratio compared between PTB cases and term controls. Discrimination (area under the receiver operating characteristic curve, AUC) and calibration for PTB <37 and <34 weeks' gestation were tested, with model tuning using clinical factors. Measured outcomes included all PTBs (any birth ≤37 weeks' gestation) and spontaneous PTBs (birth ≤37 weeks' gestation with clinical signs of initiation of parturition). RESULTS: Complete data were available for 4984 (99.7%) individuals. The cohort PTB rate was 6.7% (n = 335). We observed an inverse association between the IGFBP4/SHBG ratio and gestational age at birth (p = 0.017; AUC 0.60 [95% CI, 0.53-0.68]). Including previous PTB (for multiparous women) or prior miscarriage (for primiparous women) improved performance (AUC 0.65 and 0.70, respectively, for PTB <37 and <34 weeks' gestation). Optimal performance (AUC 0.74) was seen within 19-20 weeks' gestation, for BMI >21 kg/m2 and age 20-35 years. CONCLUSION: We have validated a novel serum biomarker for PTB risk stratification in a very different setting to the original study. Further research is required to determine appropriate ratio thresholds based on the prevalence of risk factors and the availability of resources and preventative therapies.


Assuntos
Nascimento Prematuro , Gravidez , Recém-Nascido , Humanos , Feminino , Adulto Jovem , Adulto , Nascimento Prematuro/epidemiologia , Nascimento Prematuro/diagnóstico , Estudos de Coortes , Peptídeos Semelhantes à Insulina , Prognóstico , Globulina de Ligação a Hormônio Sexual , Vietnã/epidemiologia , Idade Gestacional , Biomarcadores
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA