RESUMO
The presence of emerging contaminants (ECs) in different aquatic systems may contribute to hazardous effects on aquatic organisms and subsequently on human health. In the present work, liquid chromatography coupled to a quadrupole time of flight mass spectrometer (LC-Q-ToF-MS) was used to identify and quantify a series of ECs in Periyar River in Aluva region, Kerala, India. The water samples were pre concentrated using solid-phase extraction (SPE) prior to analysis. The compounds were probed in both positive and negative ionization mode using electro spray ionization (ESI). Method validations were performed for linearity, limit of detection (LOD), limit of quantification (LOQ), accuracy, and precision (intraday and inter day). The ECs were quantified using standard calibration curve. The identified nine ECs include pharmaceuticals, personal care products, steroids, surfactants, and phthalate. A relatively high concentration was observed in the case of 2-dodecyl benzene sulfonic acid (1012 ng/l) and low concentration was observed for lignocaine (4.3 ng/l; since this is below LOQ, the value is only approximate). In addition, we have identified another 28 organic compounds using the technique of non-target analysis out of which seven compounds fall in the category of surfactants. Being the first report on ECs in Periyar River, the data is very important as this river is one of the biggest and important rivers of Kerala having several purification units for drinking water in the province.
Assuntos
Monitoramento Ambiental/métodos , Poluentes Químicos da Água/análise , Cromatografia Líquida/métodos , Humanos , Índia , Limite de Detecção , Compostos Orgânicos , Rios/química , Extração em Fase Sólida/métodos , Espectrometria de Massas em Tandem/métodosRESUMO
Steroid hormones (SHs) are among the important classes of Contaminants of Emerging Concern (CECs) whose detection in aquatic environments is vital due to their potential adverse health impacts. Their detection is challenging because of their lower stability in natural conditions and low concentrations. This study reports the presence of steroid hormones in a major river system, the Periyar River, in Kerala (India). Water samples were collected from thirty different river locations in the case of SHs and five locations within these in the case of other CECs. These were subjected to LC-MS/MS and LC-Q-ToF/MS analyses. Five SHs, estriol, estrone, 17 ß estradiol, progesterone, and hydroxy progesterone, were separated and targeted using MS techniques. The studies of the water samples confirmed the presence of the first three estrogens in different sampling sites, with estrone present in all the sampling sites. The concentration of estrone was detected in the range from 2 to 15 ng/L. Estriol and estradiol concentrations ranged from 1.0 to 5 ng/L and 1-6 ng/L, respectively. The hormones at some selected sites were continuously monitored for seven months. The chosen areas include the feed water sites for the drinking water treatment plants across the river. The monthly data revealed that estrone is the only SHs detected in all the samples in the selected months. The highest concentration of SH was found in August. Twelve CECs belonging to pharmaceuticals and personal care products were identified and quantified. In addition, 31 other CECs were also identified using non-target analysis. A detailed study of the hormone mapping reported here is the first from any South Indian River.