Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 40
Filtrar
1.
Phys Rev Lett ; 131(8): 082502, 2023 Aug 25.
Artigo em Inglês | MEDLINE | ID: mdl-37683153

RESUMO

We present an apparatus for detection of cyclotron radiation yielding a frequency-based ß^{±} kinetic energy determination in the 5 keV to 2.1 MeV range, characteristic of nuclear ß decays. The cyclotron frequency of the radiating ß particles in a magnetic field is used to determine the ß energy precisely. Our work establishes the foundation to apply the cyclotron radiation emission spectroscopy (CRES) technique, developed by the Project 8 Collaboration, far beyond the 18-keV tritium endpoint region. We report initial measurements of ß^{-}'s from ^{6}He and ß^{+}'s from ^{19}Ne decays to demonstrate the broadband response of our detection system and assess potential systematic uncertainties for ß spectroscopy over the full (MeV) energy range. To our knowledge, this is the first direct observation of cyclotron radiation from individual highly relativistic ß's in a waveguide. This work establishes the application of CRES to a variety of nuclei, opening its reach to searches for new physics beyond the TeV scale via precision ß-decay measurements.

2.
Phys Rev Lett ; 125(16): 164802, 2020 Oct 16.
Artigo em Inglês | MEDLINE | ID: mdl-33124843

RESUMO

We demonstrate efficient transverse compression of a 12.5 MeV/c muon beam stopped in a helium gas target featuring a vertical density gradient and crossed electric and magnetic fields. The muon stop distribution extending vertically over 14 mm was reduced to a 0.25 mm size (rms) within 3.5 µs. The simulation including cross sections for low-energy µ^{+}-He elastic and charge exchange (µ^{+}↔ muonium) collisions describes the measurements well. By combining the transverse compression stage with a previously demonstrated longitudinal compression stage, we can improve the phase space density of a µ^{+} beam by a factor of 10^{10} with 10^{-3} efficiency.

3.
Br J Anaesth ; 114(6): 944-50, 2015 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-25962611

RESUMO

BACKGROUND: Successful external cephalic version (ECV) for breech presenting fetus reduces the need for Caesarean section (CS). We aimed to compare the success rate of ECV with either spinal anaesthesia (SA) or i.v. analgesia using remifentanil. METHODS: In a double-phased, stratified randomized blinded controlled study we compared the success rates of ECV, performed under spinal anaesthesia (SA), i.v. analgesia (IVA) using remifentanil or no anaesthetic interventions. In phase I, 189 patients were stratified by parity before randomization to ECV, performed by blinded operators, under SA using either hyperbaric bupivacaine 9 mg with fentanyl 15 µg, i.v. remifentanil infusion 0.1 µg kg min(-1), or Control (no anaesthetic intervention). Operators performing ECV were blinded to the treatment allocation. In phase 2, patients in the Control group in whom the initial ECV failed were further randomized to receive either SA (n=9) or IVA (n=9) for a re-attempt. The primary outcome was the incidence of successful ECV. RESULTS: The success rate in Phase 1 was greatest using SA [52/63 (83%)], compared with IVA [40/63 (64%)] and Control [40/63 (64%)], (P=0.027). Median [IQR] pain scores on a visual analogue scale (range 0-100), were 0 [0-0] with SA, 35 [0-60] with IVA and 50 [30-75] in the Control group (P<0.001). Median [IQR] VAS sedation scores were highest with IVA [75 (50-80)], followed by SA, [0 (0-50)] and Control [0 (0-0)]. In phase 2, 7/9 (78%) of ECV re-attempts were successful with SA, whereas all re-attempts using IVA failed (P=0.0007). The incidence of fetal bradycardia necessitating emergency CS within 30 min, was similar among groups; 1.6% (1/63) in the SA and IVA groups and 3.2% (2/63) in the Control group. CONCLUSIONS: SA increased the success rate and reduced pain for both primary and re-attempts of ECV, whereas IVA using remifentanil infusion only reduced the pain. There was no significant increase in the incidence of fetal bradycardia or emergency CS, with ECV performed under anaesthetic interventions. Relaxation of the abdominal muscles from SA appears to underlie the improved outcomes for ECV.


Assuntos
Anestesia Obstétrica/métodos , Apresentação Pélvica/cirurgia , Cesárea/métodos , Versão Fetal/métodos , Adulto , Raquianestesia , Anestésicos Intravenosos , Anestésicos Locais , Bradicardia/fisiopatologia , Bupivacaína , Feminino , Fentanila , Frequência Cardíaca Fetal , Humanos , Recém-Nascido , Medição da Dor , Piperidinas , Gravidez , Remifentanil
4.
Br J Anaesth ; 110(1): 59-65, 2013 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-23015618

RESUMO

BACKGROUND: Closed-loop feedback computer-controlled infusion has not been described for administering phenylephrine to maintain arterial pressure (AP) during spinal anaesthesia for caesarean delivery. We aimed to compare AP control using this automated system with a previously described manual infusion system. METHODS: We randomly allocated 222 healthy subjects having spinal anaesthesia for scheduled caesarean delivery to have systolic AP maintained near baseline with phenylephrine (100 µg ml(-1)) by computer-controlled infusion utilizing a proportional algorithm or manual-controlled infusion utilizing an on-off algorithm. AP control was assessed by comparing the proportion of systolic AP measurements within ±20% of baseline and by performance error (PE) calculations. RESULTS: A total of 212 subjects finished the study. In the computer-control group, 97% of systolic AP recordings fell within ±20% of baseline compared with 95% in the manual-control group (P=0.0004). For computer-control compared with manual-control, wobble was smaller [median 3.5 (inter-quartile range 2.5-4.8)% vs 4.2 (3.3-5.9)%, P=0.003], but there was no difference in the median PE [2.9 (0.3-4.7)% vs 1.9 (0-4.2)%], median absolute PE [4.7 (3.5-5.6)% vs 4.7 (3.8-6.7)%], or divergence [-0.01 (-0.03-0)% vs -0.06 (-0.26-0.08)%]. Fewer interventions per subject for controlling AP were required in the computer-control group [2 (2-2) vs 10 (8-13), P<0.001]. There were no differences in measured clinical outcomes. CONCLUSIONS: Within the constraints of the studied algorithms, closed-loop feedback computer-controlled phenylephrine infusion provided better AP control with fewer interventions required compared with manual-controlled infusion.


Assuntos
Anestesia Obstétrica/métodos , Raquianestesia/métodos , Pressão Arterial/efeitos dos fármacos , Cesárea/métodos , Fenilefrina/uso terapêutico , Vasoconstritores/uso terapêutico , Adulto , Algoritmos , Computadores , Feminino , Humanos , Recém-Nascido , Infusões Intravenosas , Fenilefrina/administração & dosagem , Gravidez , Resultado do Tratamento , Vasoconstritores/administração & dosagem , Adulto Jovem
5.
Phys Rev Lett ; 108(14): 143401, 2012 Apr 06.
Artigo em Inglês | MEDLINE | ID: mdl-22540791

RESUMO

We report on muonium (Mu) emission into vacuum following µ(+) implantation in mesoporous thin SiO(2) films. We obtain a yield of Mu into vacuum of (38±4)% at 250 K and (20±4)% at 100 K for 5 keV µ(+) implantation energy. From the implantation energy dependence of the Mu vacuum yield we determine the Mu diffusion constants in these films: D(Mu)(250 K)=(1.6±0.1)×10(-4) cm(2)/s and D(Mu)(100 K)=(4.2±0.5)×10(-5) cm(2)/s. Describing the diffusion process as quantum mechanical tunneling from pore to pore, we reproduce the measured temperature dependence ∼T(3/2) of the diffusion constant. We extract a potential barrier of (-0.3±0.1) eV which is consistent with our computed Mu work function in SiO(2) of [-0.3,-0.9] eV. The high Mu vacuum yield, even at low temperatures, represents an important step toward next generation Mu spectroscopy experiments.

6.
Br J Anaesth ; 109(6): 950-6, 2012 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-23059960

RESUMO

BACKGROUND: Aortocaval compression (ACC) can result in haemodynamic disturbances and uteroplacental hypoperfusion in parturients. Its detection is difficult because in most patients, sympathetic compensation results in no signs or symptoms. However, profound hypotension may develop after sympathectomy during regional anaesthesia. In this prospective observational study, we aimed to detect ACC by analysing haemodynamic changes in term parturients who were positioned sequentially at different angles of lateral tilt. METHODS: We studied haemodynamic changes in 157 non-labouring term parturients who were positioned in random order at 0°, 7.5°, 15°, and full left lateral tilt. Cardiac output (CO), stroke volume, and systemic vascular resistance were derived using suprasternal Doppler. Non-invasive arterial pressure (AP) measured in the upper and lower limbs was analysed to detect aortic compression. RESULTS: CO was on average 5% higher when patients were tilted at ≥15° compared with <15°. In a subgroup of patients (n=11), CO decreased by more than 20%, without changes in systolic AP, when they were tilted to <15° which was considered attributable to severe inferior vena caval compression. Only one patient in the supine position had aortic compression with the systolic AP in the upper limb 25 mm Hg higher than the lower limb. CONCLUSIONS: Patients with ACC can be identified by the CO changes from serial measurements between supine, 15°, or full lateral tilt. Our findings suggest that in non-labouring parturients, ACC is asymptomatic and can be effectively minimized by the use of a left lateral tilt of 15° or greater.


Assuntos
Hemodinâmica , Posicionamento do Paciente/efeitos adversos , Postura , Complicações Cardiovasculares na Gravidez/etiologia , Doenças Vasculares/etiologia , Adulto , Doenças da Aorta/etiologia , Pressão Arterial , Débito Cardíaco , Constrição Patológica , Feminino , Humanos , Posicionamento do Paciente/métodos , Gravidez , Estudos Prospectivos , Volume Sistólico , Ultrassonografia Doppler , Resistência Vascular , Veia Cava Inferior/fisiopatologia , Adulto Jovem
7.
Br J Anaesth ; 105(3): 355-60, 2010 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-20576633

RESUMO

BACKGROUND: During general anaesthesia (GA) for Caesarean section (CS), fetal oxygenation is increased by administering an inspired oxygen fraction (Fi(o(2))) of 1.0. However, it is unclear whether such high Fi(o(2)) will increase oxygen free radical activity. METHODS: We randomized 39 ASA I-II parturients undergoing elective CS under GA to receive 30% (Gp 30), 50% (Gp 50), or 100% (Gp 100) oxygen with nitrous oxide and sevoflurane adjusted to provide equivalent minimum alveolar concentration. Baseline maternal arterial blood before preoxygenation and maternal arterial, umbilical arterial and venous blood at delivery were sampled for assays of the by-product of lipid peroxidation, isoprostane, and for measurement of blood gases and oxygen content. RESULTS: Maternal and umbilical isoprostane concentrations were similar among the three groups at delivery, despite significantly increased maternal and fetal oxygenation in Gp 100. However, paired comparisons of maternal delivery vs baseline concentration of isoprostane showed an increase at delivery for all groups [Gp 30: mean 342 (sd 210) vs 154 (65) pg ml(-1), P=0.016; Gp 50: 284 (129) vs 156 (79) pg ml(-1), P=0.009; Gp 100: 332 (126) vs 158 (68) pg ml(-1), P<0.001]. The magnitude of increase was similar in all three groups and independent of the Fi(o(2)) or duration after induction. CONCLUSIONS: GA for CS is associated with a marked increase in free radical activity in the mother and baby. The mechanism is unclear but it is independent of the inspired oxygen in the anaesthetic mixture. Therefore, when 100% oxygen is administered with sevoflurane for GA, fetal oxygenation can be increased, without inducing an increase in lipid peroxidation.


Assuntos
Anestesia por Inalação/métodos , Anestesia Obstétrica/métodos , Cesárea , Peroxidação de Lipídeos , Oxigenoterapia/métodos , Adulto , Feminino , Sangue Fetal/metabolismo , Humanos , Recém-Nascido , Cuidados Intraoperatórios/métodos , Isoprostanos/sangue , Troca Materno-Fetal , Oxigênio/sangue , Pressão Parcial , Gravidez , Resultado da Gravidez , Adulto Jovem
8.
Br J Anaesth ; 102(1): 90-6, 2009 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-19011261

RESUMO

BACKGROUND: Controversy still exists if the administration of supplementary oxygen to patients having emergency Caesarean section (CS) under regional anaesthesia is beneficial or potentially harmful. Therefore, in a prospective double-blinded study, we randomized patients having emergency CS under regional anaesthesia to receive either air or 60% oxygen until delivery and compared the effects on fetal oxygenation and lipid-peroxidation in the mother and baby. METHODS: We recruited 131 women having emergency CS under regional anaesthesia. Either 21% (air group) or 60% oxygen (oxygen group) was administered using a Venturi-type facemask until delivery. We compared the oxygen exposure duration, umbilical arterial (UA) and venous (UV) blood gases and oxygen content, and plasma concentration of 8-isoprostane. Subanalysis was performed according to whether or not fetal compromise was considered present. RESULTS: Data from 125 patients were analysed. For the oxygen group vs the air group, there were greater values for UA PO(2) [mean 2.2 (SD 0.5) vs 1.9 (0.6) kPa, P=0.01], UA O(2) content [6.6 (2.5) vs 4.9 (2.8) ml dl(-1), P=0.006], UV PO(2) [3.8 (0.8) vs 3.2 (0.8) kPa, P<0.0001], and UV O(2) content [12.9 (3.5) vs 10.4 (3.8) ml dl(-1), P=0.001]. There was no difference between the groups in maternal, UA, or UV 8-isoprostane concentration. Apgar scores and UA pH were similar between the groups. Similar changes were observed regardless of whether fetal compromise was considered present (n=37) or not (n=88). CONCLUSIONS: Breathing 60% oxygen during emergency CS under regional anaesthesia increased fetal oxygenation with no associated increase in lipid-peroxidation in the mother or fetus.


Assuntos
Anestesia por Condução/métodos , Anestesia Obstétrica/métodos , Cesárea , Oxigenoterapia , Adolescente , Adulto , Índice de Apgar , Método Duplo-Cego , Emergências , Feminino , Sangue Fetal/metabolismo , Humanos , Peroxidação de Lipídeos , Pessoa de Meia-Idade , Oxigênio/sangue , Oxigenoterapia/efeitos adversos , Oxiemoglobinas/metabolismo , Pressão Parcial , Gravidez , Estudos Prospectivos , Adulto Jovem
9.
Anaesthesia ; 63(12): 1319-26, 2008 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-19032300

RESUMO

SUMMARY: In a randomised, double-blinded study, we compared boluses of phenylephrine 100 microg with ephedrine 10 mg for treating hypotension (systolic blood pressure < 100 mmHg) in 204 patients having non-elective Caesarean section under spinal anaesthesia. Umbilical arterial (UA) and venous (UV) pH and base excess were similar between groups. In the ephedrine group, UA lactate concentration was higher (median 2.6 [interquartile range 2.3-3.3] vs 2.4 [1.9-3.0] mmolxl(-1), p = 0.002) and UV lactate concentration was higher (2.5 [2.2-3.2] vs 2.3 [1.9-2.8] mmolxl(-1), p = 0.016) and more patients had nausea or vomiting (12.7% vs 3.9%, p = 0.02). Clinical neonatal outcome was similar. Of the protocol-compliant patients (n = 148), UA Po(2) and UV Po(2) were lower in the phenylephrine group although oxygen content was similar. We conclude that phenylephrine and ephedrine are both suitable vasopressors for use in non-elective Caesarean sections.


Assuntos
Anestesia Obstétrica/efeitos adversos , Raquianestesia/efeitos adversos , Efedrina/uso terapêutico , Hipotensão/prevenção & controle , Fenilefrina/uso terapêutico , Vasoconstritores/uso terapêutico , Adulto , Pressão Sanguínea/efeitos dos fármacos , Dióxido de Carbono/sangue , Cesárea , Método Duplo-Cego , Esquema de Medicação , Efedrina/administração & dosagem , Feminino , Sangue Fetal/metabolismo , Humanos , Hipotensão/etiologia , Complicações Intraoperatórias/prevenção & controle , Ácido Láctico/sangue , Oxigênio/sangue , Pressão Parcial , Fenilefrina/administração & dosagem , Gravidez , Vasoconstritores/administração & dosagem
10.
Anaesthesia ; 62(12): 1251-6, 2007 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-17991262

RESUMO

We describe the novel use of a closed-loop feedback computer-controlled infusion of phenylephrine for maintaining blood pressure in 53 patients having spinal anaesthesia for elective caesarean section. A simple on-off algorithm was used that activated an intravenous phenylephrine infusion at 100 microg.min(-1) when systolic blood pressure was less than or equal to baseline and stopped the infusion when systolic blood pressure exceeded baseline. Up to uterine incision, 94.6% of all systolic blood pressure measurements were within the range (baseline +/- 20%). Seven patients (13.2%) had one or more episodes of hypotension (systolic blood pressure < 80% of baseline) and 23 patients (37.7%) had one or more episodes of hypertension (systolic blood pressure > 120% of baseline). No patient had nausea or vomiting and in no case was umbilical arterial blood pH < 7.2. Calculated system performance parameters were comparable with those of previously published closed-loop systems and provide a reference for the potential development and comparison of more advanced algorithms.


Assuntos
Anestesia Obstétrica/efeitos adversos , Raquianestesia/efeitos adversos , Cesárea , Hipotensão/prevenção & controle , Fenilefrina/administração & dosagem , Vasoconstritores/administração & dosagem , Adulto , Algoritmos , Pressão Sanguínea/efeitos dos fármacos , Esquema de Medicação , Sistemas de Liberação de Medicamentos/métodos , Quimioterapia Assistida por Computador/métodos , Estudos de Viabilidade , Retroalimentação , Feminino , Humanos , Hipotensão/etiologia , Complicações Intraoperatórias/prevenção & controle , Fenilefrina/uso terapêutico , Gravidez , Vasoconstritores/uso terapêutico
11.
Chest ; 114(1): 291-4, 1998 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-9674481

RESUMO

OBJECTIVES: New minimally invasive approaches for cardiac surgical procedures are constantly being developed in the hope of decreasing patient morbidity and enhancing the postoperative recovery. This report reviews the use of an upper T mini-sternotomy approach to aortic valve surgery. PATIENTS: Nine consecutive nonselected patients (5 men, 4 women, mean age, 66 years) underwent isolated aortic valve replacement with the use of this approach. Two patients had isolated aortic valve stenosis, three had isolated aortic valve incompetence, and four patients had mixed aortic valve disease. RESULTS: In all cases, an excellent view of the aortic valve was obtained, aortic valve replacement with a bileaflet mechanical prostheses was performed, and no intraoperative difficulties were encountered. Mean aortic cross-clamp time was 83 min and mean cardiopulmonary bypass perfusion time was 97 min. All patients were extubated in the operating room at the end of the surgical procedure, and there were no postoperative complications. All patients were discharged home on postoperative day 3, and there were no late complications. CONCLUSION: Through an upper T mini-sternotomy, aortic valve surgery can be performed in the conventional manner using standard surgical instruments with no alteration in cardiopulmonary bypass and myocardial protection routines. With this method, postoperative pain is reduced and patient recovery is expeditious.


Assuntos
Valva Aórtica/cirurgia , Esterno/cirurgia , Toracotomia/métodos , Idoso , Insuficiência da Valva Aórtica/cirurgia , Estenose da Valva Aórtica/cirurgia , Ponte Cardiopulmonar , Feminino , Próteses Valvulares Cardíacas , Implante de Prótese de Valva Cardíaca/métodos , Humanos , Complicações Intraoperatórias/prevenção & controle , Intubação Intratraqueal , Masculino , Procedimentos Cirúrgicos Minimamente Invasivos , Dor Pós-Operatória/prevenção & controle , Alta do Paciente , Complicações Pós-Operatórias/prevenção & controle , Desenho de Prótese , Fatores de Tempo
12.
Chest ; 115(4): 987-90, 1999 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-10208197

RESUMO

OBJECTIVES: The techniques of performing coronary revascularization without cardiopulmonary bypass are rapidly evolving. However, concern remains regarding the accuracy of coronary artery anastomoses performed on the beating heart. This report reviews the use of intraoperative angiography in the critical appraisal of "off-pump" coronary artery bypass graft (CABG) surgery. PATIENTS: Intraoperative angiography was performed in 24 consecutive patients undergoing CABG surgery without cardiopulmonary bypass. In all, 24 left internal mammary artery (LIMA) grafts and 18 saphenous vein bypass grafts were assessed for patency, anastomosis quality, distal and proximal runoff, and correct placement. RESULTS: All of the saphenous vein-to-coronary artery anastomoses were widely patent, although two patients (8%) required revision of their LIMA grafts on the basis of angiographic findings. CONCLUSION: Intraoperative angiography permits the surgeon to immediately appraise the CABG and to revise, if necessary, any graft abnormality, thus potentially eliminating the need for early repeated surgery. The practice of routine intraoperative angiography is likely to improve the outcome of CABG surgery on the beating heart.


Assuntos
Angiografia Coronária , Ponte de Artéria Coronária , Grau de Desobstrução Vascular , Humanos , Período Intraoperatório , Procedimentos Cirúrgicos Minimamente Invasivos
13.
Ann Thorac Surg ; 67(4): 1171-3, 1999 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-10320279

RESUMO

Open heart operations in patients with osteogenesis imperfecta are associated with increased morbidity and mortality resulting from tissue friability and bone brittleness. We used a ministernotomy approach for aortic valve replacement in a patient with osteogenesis imperfecta, with clear benefits and a satisfactory outcome.


Assuntos
Insuficiência da Valva Aórtica/cirurgia , Implante de Prótese de Valva Cardíaca , Osteogênese Imperfeita/complicações , Esterno/cirurgia , Adulto , Humanos , Masculino , Métodos
16.
Int J Obstet Anesth ; 22(3): 179-87, 2013 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-23692706

RESUMO

BACKGROUND: Phenylephrine given during spinal anaesthesia for caesarean delivery often induces a decrease in heart rate which may decrease cardiac output. Anticholinergic drugs may be given to attenuate this effect but may also cause more labile blood pressure. This study evaluated the effects of glycopyrrolate pre-treatment on non-invasively measured cardiac output and accuracy of blood pressure control. METHODS: At induction of spinal anaesthesia for caesarean delivery, 104 patients randomly received intravenous glycopyrrolate 4µg/kg or saline placebo. Systolic blood pressure, measured at 1-min intervals, was maintained near baseline using closed-loop feedback computer-controlled phenylephrine infusion with crystalloid cohydration. Cardiac output and stroke volume were measured using suprasternal Doppler ultrasonography at baseline and 5-min intervals for 20min. Blood pressure control was assessed using performance error calculations. RESULTS: Eleven patients were excluded. Patients who received glycopyrrolate (n=45) had greater cardiac output over time (P<0.001), greater heart rate over time (P<0.001), similar stroke volume over time (P=0.95), and lower median phenylephrine infusion rate (P=0.006) compared with control (n=48). There was no difference in the incidence of hypotension between groups. Analysis of blood pressure control showed greater positive bias, greater inaccuracy and greater wobble in the glycopyrrolate group (all P<0.05). Neonatal outcome was similar between groups. CONCLUSIONS: Glycopyrrolate 4µg/kg given at the start of a phenylephrine infusion increased heart rate and cardiac output but also decreased accuracy of blood pressure control, increased the incidence of hypertension and caused an increased incidence of dry mouth postoperatively compared with control.


Assuntos
Anestesia Obstétrica/métodos , Raquianestesia/métodos , Cesárea/métodos , Glicopirrolato/farmacologia , Hemodinâmica/efeitos dos fármacos , Antagonistas Muscarínicos/farmacologia , Fenilefrina/farmacologia , Vasoconstritores/farmacologia , Adulto , Algoritmos , Pressão Sanguínea/efeitos dos fármacos , Débito Cardíaco/efeitos dos fármacos , Método Duplo-Cego , Feminino , Frequência Cardíaca/efeitos dos fármacos , Humanos , Gravidez , Tamanho da Amostra , Volume Sistólico/efeitos dos fármacos , Adulto Jovem
17.
Anaesth Intensive Care ; 38(1): 55-64, 2010 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-20191778

RESUMO

The study objective was to show that fentanyl given five minutes prior to induction improved insertion conditions for the Classic Laryngeal Mask Airway. Previous work had shown fentanyl at 90 seconds to be unpredictable. A probit analysis design was used in which success/failure rates of different doses of fentanyl were measured and dose-response curves drawn from which the ED50 and ED95 with 95% confidence intervals were determined. Adult Chinese patients with American Society of Anesthesiologists physical status classification I or II and requiring anaesthesia for minor surgery with a laryngeal mask were recruited. They were randomly assigned to one of six dosage groups: 0.25, 0.5, 1.0, 1.5, 2.0 and 3.0 microg x kg1. Fentanyl was given prior to propofol 25 mg x kg(-1), and insertion was assessed 90 seconds later using six categories of patient response. Ninety-six patients, aged 18 to 63 years, were studied. The six dosage groups were similar As the fentanyl dose increased, fewer patients responded to insertion (P < 0.01). Dose-responses could be predicted for all categories, except resistance to insertion and laryngospasm. Probit analysis predicted an ED50 of 0.5 microg x kg(-1) and ED, of 7.5 microg x kg(-1) for ideal insertion conditions (i.e., no swallowing, gagging, body movement or laryngospasm). Commonly used fentanyl doses of 1 to 2 microg x kg(-1) only prevented patients responding to insertion in 70 to 80% of cases. When using propofol 2.5 mg x kg(-1), administering fentanyl five minutes before laryngeal mask insertion does not provide ideal insertion conditions in 95% of cases unless excessively large doses are used. An ideal dose of fentanyl that produces optimum insertion conditions could not be determined.


Assuntos
Analgésicos Opioides/administração & dosagem , Fentanila/administração & dosagem , Intubação Intratraqueal/métodos , Máscaras Laríngeas , Adolescente , Adulto , Analgésicos Opioides/uso terapêutico , Coleta de Dados , Interpretação Estatística de Dados , Relação Dose-Resposta a Droga , Método Duplo-Cego , Feminino , Fentanila/uso terapêutico , Hemodinâmica/efeitos dos fármacos , Hemodinâmica/fisiologia , Humanos , Intubação Intratraqueal/efeitos adversos , Máscaras Laríngeas/efeitos adversos , Masculino , Pessoa de Meia-Idade , Tamanho da Amostra , Fatores de Tempo , Adulto Jovem
20.
Anaesthesia ; 62(7): 654-60, 2007 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-17567339

RESUMO

Probit analysis was used to predict an optimal dose of fentanyl, co-administered with propofol 2.5 mg.kg(-1), when inserting the laryngeal mask airway. In all, 21 male and 54 female healthy Chinese patients, aged 18-63 years, requiring anaesthesia for minor surgery were recruited. They were assigned to one of five groups: placebo, 0.5, 1.0, 1.5 and 2.0 microg.kg(-1). Insertion was performed 90 s after administration and insertion conditions assessed using a six-category score. Dose-response curves could only be drawn for swallowing and movement categories, and only the ED(50) could be predicted with certainty. To provide optimal conditions in over 95% of patients, fentanyl doses well above the clinical range were required. A standard fentanyl dose of 1 mug.kg(-1), co-administered with propofol 2.5 mg.kg(-1), provided optimal conditions in 65% of cases. Ninety seconds may have been insufficient time for fentanyl to reach its peak effect.


Assuntos
Analgésicos Opioides/administração & dosagem , Fentanila/administração & dosagem , Máscaras Laríngeas , Adolescente , Adulto , Anestésicos Intravenosos , Pressão Sanguínea/efeitos dos fármacos , Relação Dose-Resposta a Droga , Feminino , Frequência Cardíaca/efeitos dos fármacos , Humanos , Intubação Intratraqueal/métodos , Masculino , Pessoa de Meia-Idade , Procedimentos Cirúrgicos Menores , Propofol , Método Simples-Cego
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA