Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 48
Filtrar
1.
Am J Respir Crit Care Med ; 210(4): 424-434, 2024 Aug 15.
Artigo em Inglês | MEDLINE | ID: mdl-38843105

RESUMO

Rationale: Idiopathic pulmonary fibrosis (IPF) is a rare and progressive disease that causes progressive cough, exertional dyspnea, impaired quality of life, and death. Objectives: Bexotegrast (PLN-74809) is an oral, once-daily, investigational drug in development for the treatment of IPF. Methods: This Phase-2a multicenter, clinical trial randomized participants with IPF to receive, orally and once daily, bexotegrast at 40 mg, 80 mg, 160 mg, or 320 mg, or placebo, with or without background IPF therapy (pirfenidone or nintedanib), in an approximately 3:1 ratio in each bexotegrast dose cohort, for at least 12 weeks. The primary endpoint was incidence of treatment-emergent adverse events (TEAEs). Exploratory efficacy endpoints included change from baseline in FVC, quantitative lung fibrosis (QLF) extent (%), and changes from baseline in fibrosis-related biomarkers. Measurements and Main Results: Bexotegrast was well tolerated, with similar rates of TEAEs in the pooled bexotegrast and placebo groups (62/89 [69.7%] and 21/31 [67.7%], respectively). Diarrhea was the most common TEAE; most participants with diarrhea also received nintedanib. Participants who were treated with bexotegrast experienced a reduction in FVC decline over 12 weeks compared with those who received placebo, with or without background therapy. A dose-dependent antifibrotic effect of bexotegrast was observed with QLF imaging, and a decrease in fibrosis-associated biomarkers was observed with bexotegrast versus placebo. Conclusions: Bexotegrast demonstrated a favorable safety and tolerability profile, up to 12 weeks for the doses studied. Exploratory analyses suggest an antifibrotic effect according to FVC, QLF imaging, and circulating levels of fibrosis biomarkers. Clinical trial registered with www.clinicaltrials.gov (NCT04396756).


Assuntos
Fibrose Pulmonar Idiopática , Indóis , Piridonas , Humanos , Fibrose Pulmonar Idiopática/tratamento farmacológico , Fibrose Pulmonar Idiopática/fisiopatologia , Masculino , Feminino , Idoso , Pessoa de Meia-Idade , Indóis/uso terapêutico , Piridonas/uso terapêutico , Piridonas/efeitos adversos , Resultado do Tratamento , Método Duplo-Cego , Relação Dose-Resposta a Droga
2.
Am J Respir Crit Care Med ; 209(4): 362-373, 2024 02 15.
Artigo em Inglês | MEDLINE | ID: mdl-38113442

RESUMO

Despite progress in elucidation of disease mechanisms, identification of risk factors, biomarker discovery, and the approval of two medications to slow lung function decline in idiopathic pulmonary fibrosis and one medication to slow lung function decline in progressive pulmonary fibrosis, pulmonary fibrosis remains a disease with a high morbidity and mortality. In recognition of the need to catalyze ongoing advances and collaboration in the field of pulmonary fibrosis, the NHLBI, the Three Lakes Foundation, and the Pulmonary Fibrosis Foundation hosted the Pulmonary Fibrosis Stakeholder Summit on November 8-9, 2022. This workshop was held virtually and was organized into three topic areas: 1) novel models and research tools to better study pulmonary fibrosis and uncover new therapies, 2) early disease risk factors and methods to improve diagnosis, and 3) innovative approaches toward clinical trial design for pulmonary fibrosis. In this workshop report, we summarize the content of the presentations and discussions, enumerating research opportunities for advancing our understanding of the pathogenesis, treatment, and outcomes of pulmonary fibrosis.


Assuntos
Pesquisa Biomédica , Fibrose Pulmonar Idiopática , Estados Unidos , Humanos , National Heart, Lung, and Blood Institute (U.S.) , Lagos , Fibrose Pulmonar Idiopática/diagnóstico , Fibrose Pulmonar Idiopática/terapia , Fatores de Risco
3.
Artigo em Inglês | MEDLINE | ID: mdl-39222437

RESUMO

OBJECTIVE: The 6-min walk test (6MWT) is a simple test widely used to assess sub-maximal exercise capacity in chronic respiratory diseases. We explored the relationship of 6-min walk distance (6MWD) with measurements of physiological, clinical, radiographic measures in patients with myositis-associated interstitial lung disease (MA-ILD). METHOD: We analyzed data from the Abatacept in Myositis Associated Interstitial lung disease (Attack My-ILD) study, a 48-week multicentre randomized trial of patients with anti-synthetase antibodies and active MA-ILD. 6MWD, forced vital capacity (FVC), diffusing capacity (DLCO), high resolution CT, and various physician/patient reported outcome measures were obtained during the trial. Spearman's correlations and repeated-measures analysis with linear mixed-effects models were used to estimate the associations between 6MWD and various physiologic, clinical and radiographic parameters both cross-sectionally and longitudinally. RESULTS: Twenty participants with a median age of 57, 55% male and 85% white were analyzed. Baseline 6MWD did not associate with baseline PFTs. Repeated-measures analysis showed 6MWD over time associated with FVC over time, but not with DLCO. 6MWD over time also correlated with UCSD dyspnea score, Borg scores, as well as global disease activity and muscle strength over time. Emotional role functioning, vitality, general health and physical functioning scores by short form 36 also correlated with 6MWD over time. CONCLUSIONS: : Exploratory work in a small cohort of MA-ILD demonstrated 6MWD over time associated with parallel changes in FVC and patient reported outcomes of dyspnea, but not with DLCO. Larger studies are needed to validate the reliability, responsiveness and utility of the 6MWT in MA-ILD. CLINICAL TRIAL REGISTRATION: ClinicalTrials.gov, NCT03215927.

4.
Respir Res ; 25(1): 78, 2024 Feb 06.
Artigo em Inglês | MEDLINE | ID: mdl-38321467

RESUMO

BACKGROUND: Despite the importance of recognizing interstitial lung abnormalities, screening methods using computer-based quantitative analysis are not well developed, and studies on the subject with an Asian population are rare. We aimed to identify the prevalence and progression rate of interstitial lung abnormality evaluated by an automated quantification system in the Korean population. METHODS: A total of 2,890 healthy participants in a health screening program (mean age: 49 years, men: 79.5%) with serial chest computed tomography images obtained at least 5 years apart were included. Quantitative lung fibrosis scores were measured on the chest images by an automated quantification system. Interstitial lung abnormalities were defined as a score ≥ 3, and progression as any score increased above baseline. RESULTS: Interstitial lung abnormalities were identified in 251 participants (8.6%), who were older and had a higher body mass index. The prevalence increased with age. Quantification of the follow-up images (median interval: 6.5 years) showed that 23.5% (59/251) of participants initially diagnosed with interstitial lung abnormality exhibited progression, and 11% had developed abnormalities (290/2639). Older age, higher body mass index, and higher erythrocyte sedimentation rate were independent risk factors for progression or development. The interstitial lung abnormality group had worse survival on follow-up (5-year mortality: 3.4% vs. 1.5%; P = 0.010). CONCLUSIONS: Interstitial lung abnormality could be identified in one-tenth of the participants, and a quarter of them showed progression. Older age, higher body mass index and higher erythrocyte sedimentation rate increased the risk of development or progression of interstitial lung abnormality.


Assuntos
Pulmão , Tomografia Computadorizada por Raios X , Masculino , Humanos , Pessoa de Meia-Idade , Prevalência , Tomografia Computadorizada por Raios X/métodos , Fatores de Risco , Estudos Retrospectivos
5.
MAGMA ; 37(3): 491-506, 2024 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-38300360

RESUMO

OBJECTIVE: Increased subcutaneous and visceral adipose tissue (SAT/VAT) volume is associated with risk for cardiometabolic diseases. This work aimed to develop and evaluate automated abdominal SAT/VAT segmentation on longitudinal MRI in adults with overweight/obesity using attention-based competitive dense (ACD) 3D U-Net and 3D nnU-Net with full field-of-view volumetric multi-contrast inputs. MATERIALS AND METHODS: 920 adults with overweight/obesity were scanned twice at multiple 3 T MRI scanners and institutions. The first scan was divided into training/validation/testing sets (n = 646/92/182). The second scan from the subjects in the testing set was used to evaluate the generalizability for longitudinal analysis. Segmentation performance was assessed by measuring Dice scores (DICE-SAT, DICE-VAT), false negatives (FN), and false positives (FP). Volume agreement was assessed using the intraclass correlation coefficient (ICC). RESULTS: ACD 3D U-Net achieved rapid (< 4.8 s/subject) segmentation with high DICE-SAT (median ≥ 0.994) and DICE-VAT (median ≥ 0.976), small FN (median ≤ 0.7%), and FP (median ≤ 1.1%). 3D nnU-Net yielded rapid (< 2.5 s/subject) segmentation with similar DICE-SAT (median ≥ 0.992), DICE-VAT (median ≥ 0.979), FN (median ≤ 1.1%) and FP (median ≤ 1.2%). Both models yielded excellent agreement in SAT/VAT volume versus reference measurements (ICC > 0.997) in longitudinal analysis. DISCUSSION: ACD 3D U-Net and 3D nnU-Net can be automated tools to quantify abdominal SAT/VAT volume rapidly, accurately, and longitudinally in adults with overweight/obesity.


Assuntos
Gordura Abdominal , Imageamento Tridimensional , Gordura Intra-Abdominal , Imageamento por Ressonância Magnética , Redes Neurais de Computação , Obesidade , Humanos , Imageamento por Ressonância Magnética/métodos , Feminino , Masculino , Pessoa de Meia-Idade , Adulto , Imageamento Tridimensional/métodos , Gordura Abdominal/diagnóstico por imagem , Obesidade/diagnóstico por imagem , Gordura Intra-Abdominal/diagnóstico por imagem , Estudos Longitudinais , Sobrepeso/diagnóstico por imagem , Reprodutibilidade dos Testes , Idoso , Meios de Contraste , Algoritmos , Interpretação de Imagem Assistida por Computador/métodos
6.
Radiology ; 307(5): e230922, 2023 06.
Artigo em Inglês | MEDLINE | ID: mdl-37310252

RESUMO

Background The recent release of large language models (LLMs) for public use, such as ChatGPT and Google Bard, has opened up a multitude of potential benefits as well as challenges. Purpose To evaluate and compare the accuracy and consistency of responses generated by publicly available ChatGPT-3.5 and Google Bard to non-expert questions related to lung cancer prevention, screening, and terminology commonly used in radiology reports based on the recommendation of Lung Imaging Reporting and Data System (Lung-RADS) v2022 from American College of Radiology and Fleischner society. Materials and Methods Forty of the exact same questions were created and presented to ChatGPT-3.5 and Google Bard experimental version as well as Bing and Google search engines by three different authors of this paper. Each answer was reviewed by two radiologists for accuracy. Responses were scored as correct, partially correct, incorrect, or unanswered. Consistency was also evaluated among the answers. Here, consistency was defined as the agreement between the three answers provided by ChatGPT-3.5, Google Bard experimental version, Bing, and Google search engines regardless of whether the concept conveyed was correct or incorrect. The accuracy among different tools were evaluated using Stata. Results ChatGPT-3.5 answered 120 questions with 85 (70.8%) correct, 14 (11.7%) partially correct, and 21 (17.5%) incorrect. Google Bard did not answer 23 (19.1%) questions. Among the 97 questions answered by Google Bard, 62 (51.7%) were correct, 11 (9.2%) were partially correct, and 24 (20%) were incorrect. Bing answered 120 questions with 74 (61.7%) correct, 13 (10.8%) partially correct, and 33 (27.5%) incorrect. Google search engine answered 120 questions with 66 (55%) correct, 27 (22.5%) partially correct, and 27 (22.5%) incorrect. The ChatGPT-3.5 is more likely to provide correct or partially answer than Google Bard, approximately by 1.5 folds (OR = 1.55, P = 0.004). ChatGPT-3.5 and Google search engine were more likely to be consistent than Google Bard by approximately 7 and 29 folds (OR = 6.65, P = 0.002 for ChatGPT and OR = 28.83, P = 0.002 for Google search engine, respectively). Conclusion Although ChatGPT-3.5 had a higher accuracy in comparison with the other tools, neither ChatGPT nor Google Bard, Bing and Google search engines answered all questions correctly and with 100% consistency.


Assuntos
Neoplasias Pulmonares , Humanos , Neoplasias Pulmonares/diagnóstico por imagem , Ferramenta de Busca , Tomografia Computadorizada por Raios X , Idioma , Inteligência Artificial
7.
Rheumatology (Oxford) ; 62(11): 3690-3699, 2023 11 02.
Artigo em Inglês | MEDLINE | ID: mdl-36929924

RESUMO

OBJECTIVES: To investigate computer-aided quantitative scores from high-resolution CT (HRCT) images and determine their longitudinal changes and clinical significance in patients with idiopathic inflammatory myopathies (IIMs)-related interstitial lung disease (IIMs-ILD). METHODS: The clinical data and HRCT images of 80 patients with IIMs who underwent serial HRCT scans at least twice were retrospectively analysed. Quantitative ILD (QILD) scores (%) were calculated as the sum of the extent of lung fibrosis, ground-glass opacity, and honeycombing. The individual time-estimated ΔQILD between two consecutive scans was derived using a linear approximation of yearly changes. RESULTS: The baseline median QILD (interquartile range) scores in the whole lung were 28.1% (19.1-43.8). The QILD was significantly correlated with forced vital capacity (r = -0.349, P = 0.002) and diffusing capacity for carbon monoxide (r = -0.381, P = 0.001). For ΔQILD between the first two scans, according to the visual ILD subtype, QILD aggravation was more frequent in patients with usual interstitial pneumonia (UIP) than non-UIP (80.0% vs 44.4%, P = 0.013). Multivariable logistic regression analyses identified UIP was significantly related to radiographic ILD progression (ΔQILD >2%, P = 0.015). Patients with higher baseline QILD scores (>28.1%) had a higher risk of lung transplantation or death (P = 0.015). In the analysis of three serial HRCT scans (n = 41), dynamic ΔQILD with four distinct patterns (improving, worsening, convex and concave) was observed. CONCLUSION: QILD changes in IIMs-ILD were dynamic, and baseline UIP patterns seemed to be related to a longitudinal progression in QILD. These may be potential imaging biomarkers for lung function, changes in ILD severity and prognosis in IIMs-ILD.


Assuntos
Fibrose Pulmonar Idiopática , Doenças Pulmonares Intersticiais , Miosite , Humanos , Estudos Retrospectivos , Doenças Pulmonares Intersticiais/diagnóstico por imagem , Pulmão/diagnóstico por imagem , Miosite/diagnóstico por imagem
8.
Radiographics ; 43(5): e220105, 2023 05.
Artigo em Inglês | MEDLINE | ID: mdl-37104124

RESUMO

To translate artificial intelligence (AI) algorithms into clinical practice requires generalizability of models to real-world data. One of the main obstacles to generalizability is data shift, a data distribution mismatch between model training and real environments. Explainable AI techniques offer tools to detect and mitigate the data shift problem and develop reliable AI for clinical practice. Most medical AI is trained with datasets gathered from limited environments, such as restricted disease populations and center-dependent acquisition conditions. The data shift that commonly exists in the limited training set often causes a significant performance decrease in the deployment environment. To develop a medical application, it is important to detect potential data shift and its impact on clinical translation. During AI training stages, from premodel analysis to in-model and post hoc explanations, explainability can play a key role in detecting model susceptibility to data shift, which is otherwise hidden because the test data have the same biased distribution as the training data. Performance-based model assessments cannot effectively distinguish the model overfitting to training data bias without enriched test sets from external environments. In the absence of such external data, explainability techniques can aid in translating AI to clinical practice as a tool to detect and mitigate potential failures due to data shift. ©RSNA, 2023 Quiz questions for this article are available in the supplemental material.


Assuntos
Algoritmos , Inteligência Artificial , Humanos
9.
Rheumatology (Oxford) ; 61(12): 4702-4710, 2022 11 28.
Artigo em Inglês | MEDLINE | ID: mdl-35302602

RESUMO

OBJECTIVE: The prognosis of RA-associated interstitial lung disease (RA-ILD) is difficult to predict because of the variable clinical course. This study aimed to determine the prognostic value of an automated quantification system (AQS) in RA-ILD. METHODS: We retrospectively analysed the clinical data and high-resolution CT (HRCT) images of 144 patients with RA-ILD. Quantitative lung fibrosis (QLF, sum of reticulation and traction bronchiectasis) and ILD [QILD; sum of QLF, honeycombing (QHC), and ground-glass opacity (QGG)] scores were measured using the AQS. RESULTS: The mean age was 61.2 years, 43.8% of the patients were male, and the 5-year mortality rate was 30.5% (median follow-up, 52.2 months). Non-survivors showed older age, higher ESR and greater AQS scores than survivors. In multivariable Cox analysis, higher QLF, QHC and QILD scores were independent prognostic factors along with older age and higher ESR. In receiver-operating characteristic curve analysis, the QLF score showed better performance in predicting 5-year mortality than the QHC and QGG scores but was similar to the QILD score. Patients with high QLF scores (≥12% of total lung volume) showed higher 5-year mortality (50% vs 17.4%, P < 0.001) than those with low QLF scores and similar survival outcome to patients with idiopathic pulmonary fibrosis (IPF). Combining with clinical variables (age, ESR) further improved the performance of QLF score in predicting 5-year mortality. CONCLUSION: QLF scores might be useful for predicting prognosis in patients with RA-ILD. High QLF scores differentiate a poor prognostic phenotype similar to IPF.


Assuntos
Artrite Reumatoide , Fibrose Pulmonar Idiopática , Doenças Pulmonares Intersticiais , Masculino , Feminino , Humanos , Estudos Retrospectivos , Doenças Pulmonares Intersticiais/etiologia , Doenças Pulmonares Intersticiais/complicações , Artrite Reumatoide/complicações , Fibrose Pulmonar Idiopática/complicações , Fibrose Pulmonar Idiopática/diagnóstico por imagem , Tomografia Computadorizada por Raios X/métodos , Prognóstico
10.
Vasc Med ; 27(3): 277-282, 2022 06.
Artigo em Inglês | MEDLINE | ID: mdl-35176918

RESUMO

Background: Right heart thrombi can be a source of considerable morbidity and mortality, especially when associated with pulmonary embolism. Methods: To understand the safety and procedural efficacy associated with vacuum-assisted thrombectomy using the AngioVac System (AngioDynamics, Latham, NY, USA) to remove right heart thrombi, we conducted a subanalysis of the Registry of AngioVac Procedures in Detail (RAPID) multicenter registry representing 47 (20.1%) of 234 participants in the registry. Forty-two (89.4%) patients had thrombi located in the right atrium alone, three (6.4%) in the right ventricle alone, and two (4.3%) in both the right atrium and ventricle. Four (8.5%) patients had concomitant caval thrombi, three (6.4%) also had catheter-related thrombi, and one (2.1%) patient had both caval and catheter-related thrombi with their right heart thrombi. Results: Extracorporeal bypass time was less than 1 hour for 39 (83.0%) procedures. Seventy to 100% removal of thrombus was achieved in 59.6% of patients. Estimated blood loss was less than 250 cc for 43 procedures (91.6%). Mean hemoglobin decreased from 10.7 ± 2.2 g/dL preoperatively to 9.6 ± 1.6 g/dL postoperatively. Transfusions were administered for eight procedures (17.0%), with only one (2.1%) patient receiving more than 2 units of blood. Six patients (12.8%) experienced procedure-related adverse events, including three (6.4%) patients who experienced distal emboli and three (6.4%) patients who developed bleeding-related complications. All adverse events resolved prior to discharge. There was one death (2.1%) reported that was not procedure related. Conclusion: Vacuum-assisted thrombectomy can be performed safely in patients with right heart thrombi. ClinicalTrials.gov Identifier: NCT04414332.


Assuntos
Embolia Pulmonar , Trombose , Desenho de Equipamento , Humanos , Sistema de Registros , Trombectomia/efeitos adversos , Trombectomia/métodos , Trombose/diagnóstico por imagem , Trombose/etiologia , Trombose/cirurgia , Resultado do Tratamento
11.
J Vasc Interv Radiol ; 32(4): 549-557.e3, 2021 04.
Artigo em Inglês | MEDLINE | ID: mdl-33526346

RESUMO

PURPOSE: To assess device and procedural safety and technical success associated with the use of the AngioVac System to remove vascular thrombi and cardiac masses. MATERIALS AND METHODS: The Registry of AngioVac Procedures in Detail (RAPID) study prospectively collected data for 234 patients receiving treatment with AngioVac at 21 sites between March 2016 and August 2019: 84 (35.9%) with caval thromboemboli (CTEs), 113 (48.3%) with right heart masses (RHMs), 20 (8.5%) with catheter-related thrombi (CRTs), and 4 (1.7%) with pulmonary emboli (PEs). Thirteen patients had a combination of procedures during the same admission. RESULTS: Using the AngioVac system, 70%-100% thrombus or mass removal was achieved in 73.6% of patients with CTEs, 58.5% of patients with RHMs, 60% of patients with CRTs, and 57.1% of patients with PEs. Extracorporeal bypass time was < 1 hour for 176 (75.2%) procedures. Estimated blood loss was < 250 mL for 179 procedures (76.5%). Mean hemoglobin decreased from 10.4 g/dL ± 2.9 preoperatively to 9.4 g/dL ± 2.6 postoperatively. Transfusions were administered in 59 procedures (25.2%) with 47 transfusions (78.2%) being ≤ 2 U. There were 36 procedure-related complications, including 1 death. CONCLUSIONS: The RAPID registry data demonstrate that the AngioVac System can be safely and effectively used to remove vascular thrombi and cardiac masses across a broad range of patient populations. The limited use of the device to remove pulmonary emboli in the present series precludes recommending the use of the AngioVac device for this indication.


Assuntos
Procedimentos Endovasculares/instrumentação , Cardiopatias/terapia , Trombectomia/instrumentação , Tromboembolia/terapia , Trombose/terapia , Adulto , Idoso , Procedimentos Endovasculares/efeitos adversos , Desenho de Equipamento , Feminino , Cardiopatias/diagnóstico por imagem , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos , Sistema de Registros , Medição de Risco , Fatores de Risco , Trombectomia/efeitos adversos , Tromboembolia/diagnóstico por imagem , Trombose/diagnóstico por imagem , Fatores de Tempo , Resultado do Tratamento
12.
Eur Radiol ; 30(2): 726-734, 2020 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-31451973

RESUMO

OBJECTIVE: High-resolution computed tomography (HRCT) plays an indispensable role in the diagnosis of idiopathic pulmonary fibrosis (IPF). Due to unpredictability in progression and the short median survival of 2-5 years, it is critical to delineate the patients with rapid progression. The aim is to evaluate the predictability of IPF progression using the early quantitative changes. METHODS: Automated texture-based quantitative lung fibrosis (QLF) was calculated from the anonymized HRCT. Two datasets were collected retrospectively: (1) a pilot study of 35 subjects with three sequential scans (baseline and 6 and 12 months) to obtain a threshold, where visual assessments were stable at 6 months but worsened at 12 months; (2) 157 independent subjects to test the threshold. Landmark Cox regressions were used to compare the progression-free survival (PFS) defined by pulmonary function using the threshold from the early changes in QLF. C-indexes were reported as estimations of the concordance of prediction. RESULTS: A threshold of 4% QLF change at 6 months corresponded to the mean change that worsened on HRCT visually at 12 months from the pilot study. Using the threshold, significant differences were found in the independent dataset (hazard ratio (HZ) = 5.92, p = 0.001 by Cox model, C-index = 0.71 at the most severe lobe; and HZ = 3.22, p = 0.012, C-index = 0.68 in the whole lung). Median PFS was 11.9 months for subjects with ≥ 4% changes, whereas median PFS was greater than 18 months for subjects with < 4% changes at the most severe lobe. CONCLUSION: Early structural changes on HRCT using a quantitative score can predict progression in lung function. KEY POINTS: • Changes on HRCT using quantitative texture-based scores can play a pivotal role for providing information and an aid tool for timely management decision for patients with IPF. • Quantitative changes on HRCT of 4% or more, which matched 6-month prior changes with visual assessment of worsening, can play a pivotal role for providing prediction of clinical progression by 3-5 folds higher in the next incidence, compared with those of subjects with less than 4% changes. • Early structural changes of 4% or more in a paired HRCT scans derived by quantitative scores can predict the progression in lung function in 1-2 years in subjects with IPF, which is critical information for timely management decision for subjects with IPF where the median survival is 2 to 5 years.


Assuntos
Fibrose Pulmonar Idiopática/diagnóstico por imagem , Pulmão/diagnóstico por imagem , Tomografia Computadorizada por Raios X/métodos , Idoso , Progressão da Doença , Feminino , Seguimentos , Humanos , Fibrose Pulmonar Idiopática/patologia , Pulmão/patologia , Masculino , Projetos Piloto , Valor Preditivo dos Testes , Modelos de Riscos Proporcionais , Reprodutibilidade dos Testes , Estudos Retrospectivos
13.
Eur Radiol ; 30(3): 1822, 2020 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-31728683

RESUMO

The original version of this article, published on 24 July 2014, unfortunately contained a mistake. In section "Discussion," a sentence was worded incorrectly.

15.
Pediatr Radiol ; 48(7): 941-953, 2018 07.
Artigo em Inglês | MEDLINE | ID: mdl-29728744

RESUMO

BACKGROUND: In adults, noninvasive chemical shift encoded Cartesian magnetic resonance imaging (MRI) and single-voxel magnetic resonance (MR) spectroscopy (SVS) accurately quantify hepatic steatosis but require breath-holding. In children, especially young and sick children, breath-holding is often limited or not feasible. Sedation can facilitate breath-holding but is highly undesirable. For these reasons, there is a need to develop free-breathing MRI technology that accurately quantifies steatosis in all children. OBJECTIVE: This study aimed to compare non-sedated free-breathing multi-echo 3-D stack-of-radial (radial) MRI versus standard breath-holding MRI and SVS techniques in a group of children for fat quantification with respect to image quality, accuracy and repeatability. MATERIALS AND METHODS: Healthy children (n=10, median age [±interquartile range]: 10.9 [±3.3] years) and overweight children with nonalcoholic fatty liver disease (NAFLD) (n=9, median age: 15.2 [±3.2] years) were imaged at 3 Tesla using free-breathing radial MRI, breath-holding Cartesian MRI and breath-holding SVS. Acquisitions were performed twice to assess repeatability (within-subject mean difference, MDwithin). Images and hepatic proton-density fat fraction (PDFF) maps were scored for image quality. Free-breathing and breath-holding PDFF were compared using linear regression (correlation coefficient, r and concordance correlation coefficient, ρc) and Bland-Altman analysis (mean difference). P<0.05 was considered significant. RESULTS: In patients with NAFLD, free-breathing radial MRI demonstrated significantly less motion artifacts compared to breath-holding Cartesian (P<0.05). Free-breathing radial PDFF demonstrated a linear relationship (P<0.001) versus breath-holding SVS PDFF and breath-holding Cartesian PDFF with r=0.996 and ρc=0.994, and r=0.997 and ρc=0.995, respectively. The mean difference in PDFF between free-breathing radial MRI, breath-holding Cartesian MRI and breath-holding SVS was <0.7%. Repeated free-breathing radial MRI had MDwithin=0.25% for PDFF. CONCLUSION: In this pediatric study, non-sedated free-breathing radial MRI provided accurate and repeatable hepatic PDFF measurements and improved image quality, compared to standard breath-holding MR techniques.


Assuntos
Aumento da Imagem/métodos , Interpretação de Imagem Assistida por Computador/métodos , Imageamento Tridimensional/métodos , Imageamento por Ressonância Magnética/métodos , Hepatopatia Gordurosa não Alcoólica/diagnóstico por imagem , Técnicas de Imagem de Sincronização Respiratória/métodos , Adolescente , Artefatos , Criança , Feminino , Humanos , Masculino , Reprodutibilidade dos Testes
16.
NMR Biomed ; 30(1)2017 01.
Artigo em Inglês | MEDLINE | ID: mdl-27862507

RESUMO

The purpose of this work was to validate a parallel imaging (PI) and compressed sensing (CS) combined reconstruction method for a recently proposed 4D non-breath-held, multiphase, steady-state imaging technique (MUSIC) cardiovascular MRI in a cohort of pediatric congenital heart disease patients. We implemented a graphics processing unit accelerated CS-PI combined reconstruction method and applied it in 13 pediatric patients who underwent cardiovascular MRI after ferumoxytol administration. Conventional breath-held contrast-enhanced magnetic resonance angiography (CE-MRA) was first performed during the first pass of ferumoxytol injection, followed by the original MUSIC and the proposed CS-PI MUSIC during the steady-state distribution phase of ferumoxytol. Qualities of acquired images were then evaluated using a four-point scale. Left ventricular volumes and ejection fractions calculated from the original MUSIC and the CS-PI MUSIC were also compared with conventional multi-slice 2D cardiac cine MRI. The proposed CS-PI MUSIC reduced the imaging time of the MUSIC acquisition to 4.6 ± 0.4 min from 8.9 ± 1.2 min. Computationally intensive image reconstruction was completed within 5 min without interruption of sequential clinical scans. The proposed method (mean 3.3-4.0) provided image quality comparable to that of the original MUSIC (3.2-4.0) (all P ≥ 0.42), and better than conventional breath-held first-pass CE-MRA (1.1-3.3) for 13 anatomical structures (all P ≤ 0.0014) with good inter-observer agreement (κ > 0.46). The calculated ventricular volumes and ejection fractions from both original MUSIC (r > 0.90) and CS-PI MUSIC (r > 0.85) correlated well with 2D cine imaging. In conclusion, PI and CS were successfully incorporated into the 4D MUSIC acquisition to further reduce scan time by approximately 50% while maintaining highly comparable image quality in a clinically practical reconstruction time.


Assuntos
Técnicas de Imagem de Sincronização Cardíaca/métodos , Óxido Ferroso-Férrico , Cardiopatias Congênitas/diagnóstico por imagem , Aumento da Imagem/métodos , Imageamento Tridimensional/métodos , Imagem Cinética por Ressonância Magnética/métodos , Técnicas de Imagem de Sincronização Respiratória/métodos , Adolescente , Algoritmos , Artefatos , Criança , Meios de Contraste , Feminino , Cardiopatias Congênitas/patologia , Humanos , Interpretação de Imagem Assistida por Computador/métodos , Lactente , Recém-Nascido , Masculino , Reprodutibilidade dos Testes , Sensibilidade e Especificidade
17.
J Vasc Interv Radiol ; 28(2): 213-221, 2017 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-27979596

RESUMO

PURPOSE: To determine safety and early-term efficacy of CT-guided cryoablation for treatment of recurrent mesothelioma and assess risk factors for local recurrence. MATERIALS AND METHODS: During the period 2008-2012, 24 patients underwent 110 cryoablations for recurrent mesothelioma tumors in 89 sessions. Median patient age was 69 years (range, 48-82 y). Median tumor size was 30 mm (range, 9-113 mm). Complications were graded using Common Terminology Criteria for Adverse Events version 4.0 (CTCAE v4.0). Recurrence was diagnosed on CT or positron emission tomography/CT by increasing size, nodular enhancement, or hypermetabolic activity and analyzed using the Kaplan-Meier method. Cox proportional hazards model was used to determine covariates associated with local tumor recurrence. RESULTS: Median duration of follow-up was 14.5 months. Complications occurred in 8 of 110 cryoablations (7.3%). All but 1 complication were graded CTCAE v4.0 1 or 2. No procedure-related deaths occurred. Freedom from local recurrence was observed in 100% of cases at 30 days, 92.5% at 6 months, 90.8% at 1 year, 87.3% at 2 years, and 73.7% at 3 years. Tumor recurrence was diagnosed 4.5-24.5 months after cryoablation (mean 5.7 months). Risk of tumor recurrence was associated with a smaller ablative margin from the edge of tumor to iceball ablation margin (multivariate hazard ratio 0.68, CI 0.48-0.95, P = .024). CONCLUSIONS: CT-guided cryoablation is safe for local control of recurrent mesothelioma, with a low rate of complications and promising early-term efficacy. A smaller ablative margin may predispose to tumor recurrence.


Assuntos
Criocirurgia/métodos , Neoplasias Pulmonares/cirurgia , Mesotelioma/cirurgia , Recidiva Local de Neoplasia , Neoplasias Pleurais/cirurgia , Idoso , Idoso de 80 Anos ou mais , Criocirurgia/efeitos adversos , Intervalo Livre de Doença , Estudos de Viabilidade , Feminino , Humanos , Estimativa de Kaplan-Meier , Neoplasias Pulmonares/diagnóstico por imagem , Neoplasias Pulmonares/patologia , Masculino , Margens de Excisão , Mesotelioma/diagnóstico por imagem , Mesotelioma/patologia , Mesotelioma Maligno , Pessoa de Meia-Idade , Análise Multivariada , Neoplasia Residual , Neoplasias Pleurais/diagnóstico por imagem , Neoplasias Pleurais/patologia , Tomografia por Emissão de Pósitrons combinada à Tomografia Computadorizada , Complicações Pós-Operatórias/etiologia , Modelos de Riscos Proporcionais , Radiografia Intervencionista/métodos , Estudos Retrospectivos , Fatores de Risco , Fatores de Tempo , Tomografia Computadorizada por Raios X , Resultado do Tratamento , Carga Tumoral
18.
Eur Radiol ; 24(11): 2719-28, 2014 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-25052078

RESUMO

OBJECTIVES: The purpose of this study was to define clinically appropriate, computer-aided lung nodule detection (CAD) requirements and protocols based on recent screening trials. In the following paper, we describe a CAD evaluation methodology based on a publically available, annotated computed tomography (CT) image data set, and demonstrate the evaluation of a new CAD system with the functionality and performance required for adoption in clinical practice. METHODS: A new automated lung nodule detection and measurement system was developed that incorporates intensity thresholding, a Euclidean Distance Transformation, and segmentation based on watersheds. System performance was evaluated against the Lung Imaging Database Consortium (LIDC) CT reference data set. RESULTS: The test set comprised thin-section CT scans from 108 LIDC subjects. The median (±IQR) sensitivity per subject was 100 (±37.5) for nodules ≥ 4 mm and 100 (±8.33) for nodules ≥ 8 mm. The corresponding false positive rates were 0 (±2.0) and 0 (±1.0), respectively. The concordance correlation coefficient between the CAD nodule diameter and the LIDC reference was 0.91, and for volume it was 0.90. CONCLUSIONS: The new CAD system shows high nodule sensitivity with a low false positive rate. Automated volume measurements have strong agreement with the reference standard. Thus, it provides comprehensive, clinically-usable lung nodule detection and assessment functionality. KEY POINTS: • CAD requirements can be based on lung cancer screening trial results. • CAD systems can be evaluated using publically available annotated CT image databases. • A new CAD system was developed with a low false positive rate. • The CAD system has reliable measurement tools needed for clinical use.


Assuntos
Detecção Precoce de Câncer , Neoplasias Pulmonares/diagnóstico por imagem , Tomografia Computadorizada por Raios X/métodos , Diagnóstico Diferencial , Feminino , Humanos , Pulmão/diagnóstico por imagem , Masculino , Curva ROC , Reprodutibilidade dos Testes
19.
Artigo em Inglês | MEDLINE | ID: mdl-38645463

RESUMO

Purpose: To rule out hemorrhage, non-contrast CT (NCCT) scans are used for early evaluation of patients with suspected stroke. Recently, artificial intelligence tools have been developed to assist with determining eligibility for reperfusion therapies by automating measurement of the Alberta Stroke Program Early CT Score (ASPECTS), a 10-point scale with > 7 or ≤ 7 being a threshold for change in functional outcome prediction and higher chance of symptomatic hemorrhage, and hypodense volume. The purpose of this work was to investigate the effects of CT reconstruction kernel and slice thickness on ASPECTS and hypodense volume. Methods: The NCCT series image data of 87 patients imaged with a CT stroke protocol at our institution were reconstructed with 3 kernels (H10s-smooth, H40s-medium, H70h-sharp) and 2 slice thicknesses (1.5mm and 5mm) to create a reference condition (H40s/5mm) and 5 non-reference conditions. Each reconstruction for each patient was analyzed with the Brainomix e-Stroke software (Brainomix, Oxford, England) which yields an ASPECTS value and measure of total hypodense volume (mL). Results: An ASPECTS value was returned for 74 of 87 cases in the reference condition (13 failures). ASPECTS in non-reference conditions changed from that measured in the reference condition for 59 cases, 7 of which changed above or below the clinical threshold of 7 for 3 non-reference conditions. ANOVA tests were performed to compare the differences in protocols, Dunnett's post-hoc tests were performed after ANOVA, and a significance level of p < 0.05 was defined. There was no significant effect of kernel (p = 0.91), a significant effect of slice thickness (p < 0.01) and no significant interaction between these factors (p = 0.91). Post-hoc tests indicated no significant difference between ASPECTS estimated in the reference and any non-reference conditions. There was a significant effect of kernel (p < 0.01) and slice thickness (p < 0.01) on hypodense volume, however there was no significant interaction between these factors (p = 0.79). Post-hoc tests indicated significantly different hypodense volume measurements for H10s/1.5mm (p = 0.03), H40s/1.5mm (p < 0.01), H70h/5mm (p < 0.01). No significant difference was found in hypodense volume measured in the H10s/5mm condition (p = 0.96). Conclusion: Automated ASPECTS and hypodense volume measurements can be significantly impacted by reconstruction kernel and slice thickness.

20.
Diagn Interv Imaging ; 105(7-8): 251-265, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38679540

RESUMO

PURPOSE: The purpose of this study was to systematically review the reported performances of ChatGPT, identify potential limitations, and explore future directions for its integration, optimization, and ethical considerations in radiology applications. MATERIALS AND METHODS: After a comprehensive review of PubMed, Web of Science, Embase, and Google Scholar databases, a cohort of published studies was identified up to January 1, 2024, utilizing ChatGPT for clinical radiology applications. RESULTS: Out of 861 studies derived, 44 studies evaluated the performance of ChatGPT; among these, 37 (37/44; 84.1%) demonstrated high performance, and seven (7/44; 15.9%) indicated it had a lower performance in providing information on diagnosis and clinical decision support (6/44; 13.6%) and patient communication and educational content (1/44; 2.3%). Twenty-four (24/44; 54.5%) studies reported the proportion of ChatGPT's performance. Among these, 19 (19/24; 79.2%) studies recorded a median accuracy of 70.5%, and in five (5/24; 20.8%) studies, there was a median agreement of 83.6% between ChatGPT outcomes and reference standards [radiologists' decision or guidelines], generally confirming ChatGPT's high accuracy in these studies. Eleven studies compared two recent ChatGPT versions, and in ten (10/11; 90.9%), ChatGPTv4 outperformed v3.5, showing notable enhancements in addressing higher-order thinking questions, better comprehension of radiology terms, and improved accuracy in describing images. Risks and concerns about using ChatGPT included biased responses, limited originality, and the potential for inaccurate information leading to misinformation, hallucinations, improper citations and fake references, cybersecurity vulnerabilities, and patient privacy risks. CONCLUSION: Although ChatGPT's effectiveness has been shown in 84.1% of radiology studies, there are still multiple pitfalls and limitations to address. It is too soon to confirm its complete proficiency and accuracy, and more extensive multicenter studies utilizing diverse datasets and pre-training techniques are required to verify ChatGPT's role in radiology.


Assuntos
Radiologia , Humanos , Previsões
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA