RESUMO
Mycoplasma genitalium is a sexually transmitted bacterium linked to adverse sexual and reproductive health outcomes in women and men. M. genitalium is difficult to culture, and in the absence of validated amplified molecular methods for diagnosis of infection, there is no reference standard available for use as a comparator for the validation of new M. genitalium diagnostic tests. We evaluated the analytical and clinical performance of three transcription-mediated amplification (TMA) tests for M. genitalium, each targeting unique rRNA sequences, for use as a composite comparator for clinical validation of the Aptima Mycoplasma genitalium (AMG) assay, an in vitro diagnostic (IVD) TMA test that targets 16 s rRNA of M. genitalium Analytical sensitivity, specificity, and strain inclusivity of all four TMA tests were determined using nine laboratory strains of M. genitalium and 56 nontarget bacteria, protozoa, and viruses. Analytical sensitivity of the tests for M. genitalium ranged from 0.017 to 0.040 genome equivalents/ml. None of the nontarget organisms evaluated cross-reacted with any test. A composite comparator reference standard consisting of the 3 alternate (Alt) TMA tests was used to evaluate the clinical performance of the AMG assay by testing residual vaginal swab, female urine, and male urine specimens obtained from 1,400 adult subjects from three U.S. clinical sites. Using this reference standard to establish infected specimen status, the sensitivity, specificity, and overall agreement of the AMG IVD assay were 100%, 99.9%, and 99.9%, respectively. These results demonstrate the utility of molecular composite reference standard methodology for the clinical validation of future IVD tests for this organism.
Assuntos
Infecções por Mycoplasma/diagnóstico , Mycoplasma genitalium/genética , Técnicas de Amplificação de Ácido Nucleico/métodos , Técnicas de Amplificação de Ácido Nucleico/normas , Transcrição Gênica , Adulto , Feminino , Humanos , Masculino , Infecções por Mycoplasma/microbiologia , Infecções por Mycoplasma/urina , Pênis/microbiologia , RNA Ribossômico 16S/genética , Sensibilidade e Especificidade , Manejo de Espécimes , Vagina/microbiologiaRESUMO
SurePath specimens from women referred to colposcopy were treated with Aptima Transfer Solution (ATS) before testing in Aptima HPV (AHPV) and Aptima HPV 16, 18/45 (AHPV-GT) assays. Untreated SurePath specimens were tested with the cobas HPV test. PreservCyt specimens were assessed for cytology and tested with AHPV. High-grade cervical intraepithelial neoplasia lesions served as the reference standard. Excellent agreement (95.5%; k=0.91) was observed for ATS-treated SurePath specimens between Tigris and Panther systems and between the PreservCyt and ATS-treated SurePath specimens (91.1%, k=0.81) with the AHPV assay on Tigris. Agreement between the AHPV and cobas assays with SurePath specimens was substantial (89.9%, k=0.80). AHPV sensitivity for CIN2+(n=147) was 91.2% for SurePath and PreservCyt. Cobas HPV sensitivity was 93.9% for SurePath specimens. AHPV testing of SurePath specimens was more specific (59.4%) than cobas (54.7%) (p<0.001). Detection and genotyping showed similar absolute and relative risks. ATS-treated SurePath specimens tested with AHPV and AHPV-GT assays showed similar performance with greater specificity than cobas HPV on SurePath specimens. Similar overall results were seen using a CIN3 disease endpoint.