Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 6 de 6
Filtrar
1.
Acta Obstet Gynecol Scand ; 91(5): 598-604, 2012 May.
Artigo em Inglês | MEDLINE | ID: mdl-22313165

RESUMO

Objective. To analyze typical maternal heart rate (MHR) patterns in the first and second stages of labor. Design. Observational study. Setting. Tertiary care community hospital. Population. Normal term parturients with epidural anesthesia. Methods. Confirmed MHR and uterine activity were simultaneously recorded. The average MHR was analyzed 10 seconds before, as well as at the peak of, each contraction and/or pushing effort. Each woman contributed one datapoint at each time point to the analysis. Main outcome measure. Change in MHR during contractions. Results. First stage: 7.6±2.1 contractions per woman (n=18) were analyzed. Average MHR decreased during contractions: from 83±13 to 74±10bpm; p<0.001). In 56% (10/18) of the women, 'early' type decelerations were seen in at least 50% of contractions. Second stage: 3.5±1.5 contractions per woman. All women (n=15) showed MHR accelerations during every pushing effort (ΔMHR: +35±13bpm; 88±14 to 123±17bpm; p<0.001). MHR was persistently >100bpm in three women (17%) in the first stage, and in four women (27%) in the second stage. Peak MHR >140bpm occurred during pushing in 20%. Conclusion. Decreases in MHR during contractions in the first stage of labor can mimic fetal heart rate (FHR) accelerations as well as early type decelerations. Thus, first stage tracings with a low baseline and early type decelerations may be maternal in origin and FHR should be independently confirmed in such tracings. Because second stage MHR accelerations generally show greater amplitude than FHR accelerations, tracings with repetitive accelerations during contractions (especially when Δ >20bpm) should be considered MHR until proven otherwise.


Assuntos
Frequência Cardíaca/fisiologia , Primeira Fase do Trabalho de Parto/fisiologia , Segunda Fase do Trabalho de Parto/fisiologia , Adulto , Eletrocardiografia , Feminino , Frequência Cardíaca Fetal/fisiologia , Humanos , Gravidez , Contração Uterina/fisiologia
2.
J Occup Environ Hyg ; 9(3): 185-97, 2012.
Artigo em Inglês | MEDLINE | ID: mdl-22409444

RESUMO

This study was designed to determine how easily methamphetamine can be removed from clothing and building materials, utilizing different cleaning materials and methods. The study also addressed the penetration of methamphetamine into drywall and the ability of paints to encapsulate the methamphetamine on drywall. Clothing and building materials were contaminated in a stainless steel chamber by aerosolizing methamphetamine in a beaker heater. The amount of methamphetamine surface contamination was determined by sampling a grid pattern on the material prior to attempting to clean the materials. After cleaning, the materials were again sampled, and the degree of decontamination noted. We found that household clothing and response gear worn by first responders was easily decontaminated using a household detergent in a household washing machine. A single wash removed over 95% of the methamphetamine from these materials. The study also indicated that methamphetamine-contaminated, smooth non-porous surfaces can be easily cleaned to below detectable levels using only mild cleaners. More porous surfaces such as plywood and drywall were unlikely to be decontaminated to below regulatory levels even with three washes using a mild cleaner. This may be due to methamphetamine penetration into the paint on these surfaces. Evaluation of methamphetamine contamination on drywall indicated that approximately 40% of the methamphetamine was removed using a wipe, while another 60% remained in the paint layer. Stronger cleaners such as those with active ingredients including sodium hypochlorite or quaternary ammonia and commercial decontamination agents were more effective than mild detergent-based cleaners and may reduce methamphetamine contamination to below regulatory levels. Results from the encapsulation studies indicate that sprayed on oil-based paint will encapsulate methamphetamine on drywall and plywood surfaces up to 4.5 months, while latex paints were less effective.


Assuntos
Vestuário , Materiais de Construção , Descontaminação/métodos , Metanfetamina/química , Detergentes , Pintura , Porosidade , Propriedades de Superfície
3.
Am J Perinatol ; 28(3): 207-10, 2011 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-20827658

RESUMO

A massive obstetric hemorrhage resulting in an extremely low hematocrit (5.9%) required innovative intraoperative and postoperative management. We used a combination of rapid intraoperative volume replacement, aortic compression, chemical coma, high-dose erythropoietin, and enteral iron replacement to elevate the hematocrit in a patient refusing blood transfusions.


Assuntos
Sedação Profunda , Eritropoetina/uso terapêutico , Histerectomia , Testemunhas de Jeová , Placenta Acreta/terapia , Placenta Prévia/terapia , Adulto , Transfusão de Sangue Autóloga , Feminino , Humanos , Gravidez , Recusa do Paciente ao Tratamento
4.
J Occup Environ Hyg ; 8(11): 636-41, 2011 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-21962231

RESUMO

This study was designed to explore the efficacy of the use of wipe sampling to determine methamphetamine contamination associated with the clandestine manufacture of methamphetamine. Three laboratories were utilized to analyze wipe samples to investigate variability in reported methamphetamine concentration among samples spiked with known amounts of methamphetamine. Different sampling media, surfaces, and solvents were also utilized to determine potential differences in measured methamphetamine concentration due to different wipes, wipe solvents, and wipe contaminants. This study examined rate of false positive detection among blank samples and whether interference with common household substances would create a false positive detection of methamphetamine. Variability between the three labs-using liquid chromatography with mass spectrometry or gas chromatography with mass spectrometry for detection of a known concentration of methamphetamine-resulted in percent differences of 3-30%. Results from wipe sample analysis for methamphetamine, using methanol or isopropanol, showed no significant difference in methamphetamine contamination recovery. Dust and paint contamination on methamphetamine wipe samples with known methamphetamine spike amounts did not affect methamphetamine wipe sample recovery. This study confirmed that either methanol or isopropanol is an appropriate solvent for use in methamphetamine wipe sampling. Dust and paint contamination on wipe samples will not interfere with the wipe sample analysis for methamphetamine. False positive detection for methamphetamine was not observed in any of the blank wipe samples submitted for the study. Finally, this study determined that methamphetamine will not be detected in structures that are truly methamphetamine free at current laboratory limits of quantification.


Assuntos
Monitoramento Ambiental/métodos , Poluentes Ambientais/análise , Metanfetamina/análise , Poeira/análise , Pintura/análise , Reprodutibilidade dos Testes , Solventes/análise , Solventes/química
5.
Am J Obstet Gynecol ; 203(5): 449.e1-6, 2010 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-20619388

RESUMO

OBJECTIVE: No studies exist that have examined the effectiveness of different approaches to a reduction in elective early term deliveries or the effect of such policies on newborn intensive care admissions and stillbirth rates. STUDY DESIGN: We conducted a retrospective cohort study of prospectively collected data and examined outcomes in 27 hospitals before and after implementation of 1 of 3 strategies for the reduction of elective early term deliveries. RESULTS: Elective early term delivery was reduced from 9.6-4.3% of deliveries, and the rate of term neonatal intensive care admissions fell by 16%. We observed no increase in still births. The greatest improvement was seen when elective deliveries at <39 weeks were not allowed by hospital personnel. CONCLUSION: Physician education and the adoption of policies backed only by peer review are less effective than "hard stop" hospital policies to prevent this practice. A 5% rate of elective early term delivery would be reasonable as a national quality benchmark.


Assuntos
Unidades de Terapia Intensiva Neonatal , Trabalho de Parto Induzido , Padrões de Prática Médica , Natimorto , Análise de Variância , Distribuição de Qui-Quadrado , Feminino , Humanos , Gravidez , Estudos Retrospectivos
6.
Am J Obstet Gynecol ; 202(1): 35.e1-7, 2010 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-19889389

RESUMO

OBJECTIVE: The purpose of this study was to analyze reasons for postpartum readmission. STUDY DESIGN: We conducted a database analysis of readmissions within 6 weeks after delivery during 2007, with extended (180 day) analysis for pneumonia, appendicitis, and cholecystitis. Linear regression analysis, survival curve fitting, and Gehan-Breslow statistic with Holm-Sidak all-pairwise analysis for multiple comparisons were used. Probability values of < .05 were considered significant. RESULTS: Of 222,751 women delivered, 2655 women (1.2%) were readmitted within 6 weeks (0.83% vaginal delivery and 1.8% cesarean section delivery; P < .001). A high percentage of these readmittances occurred within the first 6 weeks: pneumonia (84%), appendicitis (43%), or cholecystitis (46%). Cumulative readmission rates were higher in the first 6 weeks after delivery than in the next 20 weeks (pneumonia curve gradient, 3.7 vs 0.11; appendicitis curve gradient, 1.1 vs 0.36; cholecystitis curve gradient, 6.6 vs 1.7). CONCLUSION: The cause of postpartum readmission is primarily infectious in origin. A recent pregnancy appears to increase the risk of pneumonia, appendicitis, and cholecystitis.


Assuntos
Apendicite/epidemiologia , Colecistite/epidemiologia , Readmissão do Paciente/estatística & dados numéricos , Pneumonia/epidemiologia , Transtornos Puerperais/epidemiologia , Cesárea/estatística & dados numéricos , Feminino , Humanos , Incidência , Período Pós-Parto/fisiologia , Gravidez
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA