Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 6 de 6
Filtrar
Mais filtros

Base de dados
Tipo de documento
Ano de publicação
Intervalo de ano de publicação
1.
Epilepsia Open ; 2024 Jul 02.
Artigo em Inglês | MEDLINE | ID: mdl-38953892

RESUMO

To conduct a systematic review of the literature regarding rates and predictors of favorable seizure outcome after resective surgery for epileptic spasms (ES) in pediatric patients. The Preferred Reporting Items for Systematic Reviews and Meta-Analyses standards were followed. We searched PubMed, EMBASE, and Cochrane CENTRAL for articles published on the prevalence or incidence of epileptic spasm since 1985. Abstract, full-text review, and data extraction were conducted by two independent reviewers. Meta-analysis was performed to assess overall seizure freedom rate. Subject-level analysis was performed on a subset of studies to identify prognostic indicators. A total of 21 retrospective studies (n = 531) were included. Meta-analysis of all studies demonstrated a pooled seizure freedom rate of 68.8%. Subject-level analysis on 18 studies (n = 360) demonstrated a significant association between duration of spasms and recurrence of spasms after surgery, with an estimated increased risk of 7% per additional year of spasms prior to operation. Patients who underwent resective surgery that was not a hemispherectomy (i.e., lobectomy, lesionectomy, etc.) had an increased recurrence risk of 57% compared to patients who had undergone hemispherectomy. Resective surgery results in seizure freedom for the majority of pediatric patients with epileptic spasms. Patients who undergo hemispherectomy have lower risk of recurrence than patients who undergo other types of surgical resection. Increased duration of spasms prior to surgery is associated with increased recurrence risk after surgery. PLAIN LANGUAGE SUMMARY: Children with epileptic spasms (ES) that do not respond to medications may benefit from surgical treatment. Our study reviewed existing research to understand how effective surgery is in treating ES in children and what factors predict better outcomes. Researchers followed strict guidelines to search for and analyze studies published since 1985, finding 21 studies with a total of 531 patients. They found that, on average, nearly 70% of children became seizure-free after surgery. Further individual analysis of 360 patients showed that longer duration of spasms before surgery increased the risk of spasms returning by 7% per year. Additionally, children who had less extensive surgeries, such as removal of only a specific part of the brain, had a 57% higher risk of seizure recurrence compared to those who had a hemispherectomy, which removed or disconnected half of the brain. Overall, the study concludes that surgery can often stop seizures, especially when more extensive surgery is performed and when the surgery is done sooner rather than later.

2.
Ultrasound Med Biol ; 2024 Jun 11.
Artigo em Inglês | MEDLINE | ID: mdl-38866649

RESUMO

OBJECTIVE: To compare anterior chamber depth (ACD) and lens thickness (LT) measurements by ultrasound biomicroscopy (UBM), A-scan cross vector (CV) overlay with UBM, and immersion A-scan technique in pediatric eyes. METHODS: This prospective comparative cohort study comprised 43 eyes of 25 pediatric participants (mean age: 2.3±2.2 y). UBM and immersion A-scan biometry were performed prior to dilation and intraocular surgery. ACD and LT were measured by UBM image analysis, A-scan CV UBM overlay, and immersion A-scan technique. RESULTS: ACD and LT measurements obtained using immersion A-scan were significantly greater than with UBM image analysis with mean differences of 0.52 mm and 0.62 mm, respectively (p < 0.001). Immersion A-scan and UBM measurements were moderately correlated (r = 0.70 and 0.64, p < 0.001). ACD and LT measurements obtained using CV overlay were not significantly different than UBM measurements and the values were strongly positively correlated (r = 0.95 and 0.93, p < 0.001). CONCLUSION: Immersion A-scan may overestimate ACD and LT compared to UBM in pediatric patients due to oblique placement of the A-scan probe relative to the optical axis. Supplemental use of UBM and/or CV overlay is indicated to improve measurement accuracy in pediatric patients who cannot reliably fixate due to the ability to confirm proper alignment of the probe with the pupil by visualizing the anterior segment.

3.
J Pediatr Surg ; 2024 Mar 14.
Artigo em Inglês | MEDLINE | ID: mdl-38580546

RESUMO

INTRODUCTION: Optimal criteria and timing for enterostomy closure (EC) in neonates is largely based on clinical progression and adequate weight, with most institutions using 2.0-2.5 kg as the minimum acceptable weight. It is unclear how the current weight cutoff affects post-operative morbidity. AIM: To determine how infant weight at the time of EC influences 30-day complications. METHODS: Infants weighing ≤4000 g who underwent EC were identified in the 2012-2019 ACS NSQIP-P database. Demographics, comorbidities, and 30-day outcomes were assessed using univariate analysis. Multivariable logistic regression controlling for ASA score, nutritional support, and ventilator support was used to estimate the independent association of weight on risk of 30-day complications. RESULTS: A total of 1692 neonates from the NSQIP-P database during the years 2012-2019 met inclusion criteria. Neonates weighing <2.5 kg were significantly more likely to have a younger gestational age, require ventilator support, and have concurrent comorbidities. Major morbidity, a composite outcome of the individual postoperative complications, was observed in 283 (16.7%) infants. ASA classifications 4 and 5, dependence on nutritional support, and ventilator support were independently associated with increased risk of 30-day complications. With respect to weight, we found no significant difference in major morbidity between infants weighing <2.5 kg and infants weighing ≥2.5 kg. CONCLUSION: Despite using a robust, national dataset, we could find no evidence that a defined weight cut-off was associated with a reduction in major morbidity, indicating that weight should not be a priority factor when determining eligibility for neonatal EC. LEVEL OF EVIDENCE: III.

4.
PLoS One ; 19(6): e0305624, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38889111

RESUMO

OBJECTIVE: To investigate the relationship between corneal diameter and internal corneal span determined from angle-to-angle distance using ultrasound biomicroscopy (UBM) in an observational cross-sectional patient population comprised of 54 eyes (28 healthy control eyes, ages 0.1 to 11.3 years; 26 eyes with primary congenital glaucoma, ages 0.1 to 3.5 years) from 41 pediatric participants ages 0.1 to 11.3 years (mean age: 3±3 years, median age: 2 years). METHODS: Forty cornea photographs with reference ruler and 110 UBM images were obtained. Three observers measured horizontal and vertical corneal diameter and angle-to-angle distance in each cornea photo and UBM image using ImageJ and the average values were used. Main outcome measures were Pearson correlation coefficient, linear regression, mean difference between corneal diameter and angle-to-angle distance, and intra-class correlation coefficients among measurements from all three observers for each parameter. RESULTS: Corneal diameter and angle-to-angle distance had a strong positive correlation horizontally (Pearson r = 0.89, p<0.001) and vertically (r = 0.93, p<0.001). Correlation was consistent regardless of presence of primary congenital glaucoma and participant age. Regression analysis demonstrated a linear relationship between the parameters for horizontal (CD = 0.99*AA+0.28, R2 = 0.81, p<0.001) and vertical (CD = 0.91 *AA+1.32, R2 = 0.85, p<0.001) dimensions. Overall, reliability was good-excellent, ranging from an ICC of 0.76 for vertical corneal diameter to 0.90 for horizontal angle-to-angle distance. CONCLUSIONS: Based on the strong positive correlation found between corneal diameter and angle-to-angle distance in our study population, UBM image analysis can be used to accurately estimate corneal diameter from angle-to-angle distance in children with healthy eyes and primary congenital glaucoma. UBM may provide a useful intraocular alternative for estimating corneal diameter and monitoring diseases that affect the cornea in infants and children, such as congenital glaucoma.


Assuntos
Córnea , Microscopia Acústica , Humanos , Pré-Escolar , Córnea/diagnóstico por imagem , Criança , Microscopia Acústica/métodos , Masculino , Feminino , Lactente , Estudos Transversais , Glaucoma/diagnóstico por imagem , Glaucoma/patologia
5.
J AAPOS ; 27(6): 369-372, 2023 12.
Artigo em Inglês | MEDLINE | ID: mdl-37777051

RESUMO

Congenital ocular anomalies may be detected on prenatal imaging using fetal ultrasound and magnetic resonance imaging (MRI), although standard prenatal ultrasound for fetal physical development does not currently include ocular and orbital evaluation. We present the case of a male infant born at 39 weeks' gestation with microphthalmia with cyst that was characterized using serial multimodal imaging, including fetal ultrasound and MRI, B-scan ultrasonography, ultrasound biomicroscopy, and postnatal MRI. Multiple prenatal and postnatal imaging modalities yielded comparable evaluations of the ocular and orbital pathology, validating the prenatal assessments.


Assuntos
Cistos , Microftalmia , Gravidez , Lactente , Feminino , Masculino , Humanos , Microftalmia/diagnóstico por imagem , Ultrassonografia Pré-Natal , Cistos/diagnóstico por imagem , Imageamento por Ressonância Magnética/métodos , Idade Gestacional
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA