Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 15 de 15
Filtrar
1.
Eur Radiol ; 31(12): 9150-9160, 2021 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-34050801

RESUMO

OBJECTIVES: The failure rate following prostate artery embolization (PAE) is around 20%, which may in part result from inadequate embolization. Prostate contrast retention (PCR) adequacy on immediate post-embolization cone-beam CT may provide better assessment of embolization completeness than arterial contrast stasis seen on fluoroscopy alone. The aim of this study was to evaluate outcomes of PAE using PCR adequacy as the procedural endpoint. METHODS: A retrospective cohort study of all PAE cases using this technique at a single large volume center was conducted. Following initial embolization of the main prostatic arteries, if PCR was inadequate, additional embolization was performed. Technical success (adequate PCR) was defined as > 75% global prostate gland contrast staining. Clinical success was determined in accordance to CIRSE standards of practice. RESULTS: One hundred sixty-five patients (mean age 68 ± 8.4 years) underwent PAE from June 2017 to March 2019. Technical and clinical success rates were 98.8% and 96.4% respectively. Clinical success rate was significantly higher in patients with adequate PCR. International Prostate Symptom Scores (IPSS) and Quality of Life (QoL) scores significantly improved at 1-, 3-, 6-, and 12-month follow-up when compared to baseline. Prostate volume (PV) and post-voiding residual bladder volume were significantly reduced at 3, 6, and 12 months in comparison to baseline. Mild (Clavien-Dindo grade I/II) and moderate (grade III) complication rates were 12.1% and 3.6% respectively. CONCLUSIONS: By using PCR adequacy as a guide to determine the procedure endpoint for PAE, it may be possible to achieve more complete embolization and thus higher clinical success rates. KEY POINTS: • By using PCR adequacy as a guide to determine the procedure endpoint for PAE, it may be possible to achieve more complete embolization and thus higher clinical success rates.


Assuntos
Embolização Terapêutica , Sintomas do Trato Urinário Inferior , Hiperplasia Prostática , Idoso , Artérias/diagnóstico por imagem , Humanos , Masculino , Pessoa de Meia-Idade , Hiperplasia Prostática/diagnóstico por imagem , Hiperplasia Prostática/terapia , Qualidade de Vida , Estudos Retrospectivos , Resultado do Tratamento
3.
J Vasc Interv Radiol ; 27(1): 32-8, 2016 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-26549371

RESUMO

PURPOSE: To compare the ability of dedicated software and conventional cone-beam computed tomography (CT) analysis to identify tumor-feeding vessels in hypervascular liver tumors treated with chemoembolization. MATERIAL AND METHODS: Between January 2012 and January 2013, 45 patients (32 men, mean age of 61 y; range, 27-85 y) were enrolled, and 66 tumors were treated (mean, 32 mm ± 18; range, 10-81 mm) with conventional chemoembolization with arterial cone-beam CT. Data were independently analyzed by six interventional radiologists with standard postprocessing software, a computer-aided analysis with FlightPlan for liver (FPFL; ie, "raw FPFL"), and a review of this computer-aided FPFL analysis ("reviewed FPFL"). Analyses were compared with a reference reading established by two study supervisors in consensus who had access to all imaging data. Sensitivities, positive predictive values (PPVs), and false-positive (FP) ratios were compared by McNemar, χ(2), and Fisher exact tests. Analysis durations were compared by Mann-Whitney test, and interreader agreement was assessed. RESULTS: Reference reading identified 179 feeder vessels. The sensitivity of raw FPFL was significantly higher than those of reviewed FPFL and conventional analyses (90.9% vs 83.2% and 82.1%; P < .0001), with lower PPV (82.9% vs 91.2% and 90.6%, respectively; P < .0001), higher FP ratio (17.1% vs 9.4% and 8.8%, respectively; P < .0001), and greater interreader agreement (92% vs 80% and 79%, respectively; P < .0001). Reviewed FPFL analysis took significantly longer than both other analyses (P < .0001). CONCLUSIONS: The FPFL analysis software enabled a fast, accurate, and sensitive detection of tumor feeder vessels.


Assuntos
Quimioembolização Terapêutica , Tomografia Computadorizada de Feixe Cônico , Neoplasias Hepáticas/irrigação sanguínea , Neoplasias Hepáticas/terapia , Interpretação de Imagem Radiográfica Assistida por Computador/métodos , Adulto , Idoso , Idoso de 80 Anos ou mais , Angiografia , Feminino , Humanos , Imageamento Tridimensional , Fígado/irrigação sanguínea , Fígado/diagnóstico por imagem , Neoplasias Hepáticas/diagnóstico por imagem , Masculino , Pessoa de Meia-Idade , Reprodutibilidade dos Testes , Estudos Retrospectivos , Sensibilidade e Especificidade , Software
4.
CVIR Endovasc ; 7(1): 52, 2024 Jun 27.
Artigo em Inglês | MEDLINE | ID: mdl-38935311

RESUMO

BACKGROUND: Varicocele embolization is an effective, minimally invasive treatment option, with a symptom improvement rate of around 90%. However, anatomical variations and post-embolization recurrences pose challenges to its efficacy. This article discusses the antegrade embolization technique as a viable alternative for cases in which retrograde embolization fails, offering a broader spectrum of treatment options for varicocele. CASE PRESENTATION: This case report details the treatment of a 27-year-old male with a left varicocele, diagnosed during infertility assessment, using an alternative embolization technique. Despite initial failed attempts at retrograde catheterization via the femoral vein, a direct inguinal puncture of the left testicular vein was successfully performed under ultrasound guidance. A mixture of Glubran® and Lipiodol® was used for embolization, achieving varicocele embolization without complications. The patient was discharged 2 hours post-procedure, with follow-up confirming the procedure's effectiveness and safety. CONCLUSION: This article introduces a less invasive, ultrasound-guided technique for varicocele embolization, presenting a viable alternative to surgery when conventional retrograde methods fail.

5.
Gastroenterol Clin Biol ; 26(6-7): 633-5, 2002.
Artigo em Francês | MEDLINE | ID: mdl-12193865

RESUMO

Groove pancreatitis is a rare form of segmental chronic pancreatitis which is localized within the head of the pancreas, the duodenum and the common bile duct. Symptoms are due to common bile duct stenosis or duodenal stenosis. Radiologically, there is a pancreatic mass, which hinders differential diagnosis with pancreatic carcinoma. We report here a case of groove pancreatitis observed in a 41-year-old man treated by pancreatoduodenectomy. Histological features of the groove scar were noted. Our case and cases reported in the literature lead to hypotheses concerning the pathogenesis and clinical, biological, and radiological features suggestive of the diagnosis.


Assuntos
Pancreatite/diagnóstico , Pancreatite/patologia , Adulto , Doença Crônica , Humanos , Masculino , Pancreaticoduodenectomia , Pancreatite/cirurgia , Tomografia Computadorizada por Raios X
7.
Cardiovasc Intervent Radiol ; 33(6): 1235-42, 2010 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-20390271

RESUMO

The purpose of this study was to evaluate computed analysis of three-dimensional (3D) cone-beam computed tomography angiography (CTA) of the liver for determination of subsegmental tumor-feeding vessels (FVs). Eighteen consecutive patients underwent transarterial chemoembolization (TACE) from January to October 2008 for 25 liver tumors (15 hepatocellular carcinomas [HCCs] and 10 neuroendocrine metastases). Anteroposterior projection angiogram (two-dimensional [2D]) and 3D cone-beam CTA images were acquired by injection of the common hepatic artery. Retrospectively, FVs were independently identified by three radiology technologists using a software package (S) that automatically determines FVs by analysis of 3D images. Subsequently, three interventional radiologists (IRs) independently identified FVs by reviewing the 2D images followed by examination of the 3D images. Finally, the "ground truth" for the number and location of FVs was obtained by consensus among the IRs, who were allowed to use any imaging-including 2D, 3D, and all oblique or selective angiograms-for such determination. Sensitivities, durations, and degrees of agreement for review of 2D, 3D, and S results were evaluated. Sensitivity of 3D (73%) was higher than 2D (64%) images for identification of FVs (P = 0.036). The sensitivity of S (93%) was higher than 2D (P = 0.02) and 3D (P = 0.005) imaging. The duration for review of 3D imaging was longer than that for 2D imaging (187 vs. 94 s, P = 0.0001) or for S (135 s, P = 0.0001). The degree of agreement between the IRs using 2D and 3D imaging were 54% and 62%, respectively, whereas it was 82% between the three radiology technologists using S. These preliminary data show that computed determination of FVs is both accurate and sensitive.


Assuntos
Angiografia/métodos , Carcinoma Hepatocelular/irrigação sanguínea , Carcinoma Hepatocelular/diagnóstico por imagem , Carcinoma Hepatocelular/terapia , Quimioembolização Terapêutica , Tomografia Computadorizada de Feixe Cônico/métodos , Neoplasias Hepáticas/irrigação sanguínea , Neoplasias Hepáticas/diagnóstico por imagem , Neoplasias Hepáticas/terapia , Interpretação de Imagem Radiográfica Assistida por Computador/métodos , Adulto , Idoso , Meios de Contraste , Feminino , Humanos , Imageamento Tridimensional , Masculino , Pessoa de Meia-Idade , Projetos Piloto , Estudos Retrospectivos , Sensibilidade e Especificidade , Software , Resultado do Tratamento , Ácidos Tri-Iodobenzoicos
9.
J Vasc Interv Radiol ; 16(2 Pt 1): 247-53, 2005 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-15713926

RESUMO

PURPOSE: To evaluate the feasibility, efficacy, and tolerance of self-expanding metallic stent insertion under fluoroscopic guidance for palliation of symptoms related to malignant gastroduodenal obstruction. MATERIALS AND METHODS: Seventy-two patients (38 men, 34 women) aged 25-98 years (mean, 62 years) with duodenal (n = 43), antropyloric (n = 13), surgical gastrojejunostomy (n = 10), or pyloroduodenal (n = 6) malignant obstruction were referred for insertion of self-expanding metallic stents over a 6-year period. Stent insertion was performed with use of a peroral or transgastric approach when necessary (n = 11). RESULTS: Stents were successfully inserted in 70 of the 72 patients (97%) and provided symptom relief in 65 patients (90%). Inserted stents were mainly uncovered vascular (n = 55) or enteral (n = 10) Wallstents. One hundred eight stents were initially inserted: one, two, three, or four stents were indicated in 43, 17, nine, and one patient, respectively. Mean follow-up was 119 days (range, 4-513 days). Mean stent patency was 113 days (range, 4-513 days). Mean survival of patients was 120 days. During follow-up, stent obstruction occurred in seven patients as a result of tumoral overgrowth (n = 5) or ingrowth (n = 2). Complications occurred in 12 of the 72 patients (17%), including stent migration (n = 8), stent fracture (n = 1), duodenal perforation (n = 1), and death related to general anesthesia (n = 1). CONCLUSION: Despite a significant complication rate, self-expanding metallic stent insertion under fluoroscopic guidance appears to be a feasible and useful technique in the palliative management of malignant gastroduodenal obstruction.


Assuntos
Neoplasias Abdominais/complicações , Obstrução Duodenal/terapia , Obstrução da Saída Gástrica/terapia , Cuidados Paliativos , Stents , Adulto , Idoso , Idoso de 80 Anos ou mais , Obstrução Duodenal/etiologia , Desenho de Equipamento , Estudos de Viabilidade , Feminino , Fluoroscopia , Seguimentos , Migração de Corpo Estranho/etiologia , Obstrução da Saída Gástrica/etiologia , Humanos , Jejuno/cirurgia , Masculino , Pessoa de Meia-Idade , Radiografia Intervencionista , Recidiva , Estudos Retrospectivos , Stents/efeitos adversos , Estômago/cirurgia , Taxa de Sobrevida , Resultado do Tratamento
10.
AJR Am J Roentgenol ; 180(2): 527-32, 2003 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-12540466

RESUMO

OBJECTIVE: Our objective was to describe the technical aspects and evaluate the feasibility, safety, and efficacy of endovascular management of mechanical complications related to implanted central venous devices. MATERIALS AND METHODS: One hundred fifty-six patients with cancer, who ranged in age from 3 months to 75 years (mean +/- SD, 47 +/- 18 years), were referred 290 +/- 200 days (mean +/- SD; range, 0-1202 days) after central venous device placement for retrieval of a fractured and embolized central venous device catheter (n = 100), retrieval of a guidewire embolized during placement of a central venous device (n = 2), repositioning of the migrated tip of a central venous device catheter (n = 38), and fibrin-sheath stripping (n = 16). All procedures were performed with the patient under local anesthesia on an outpatient basis, except for the eight pediatric patients. RESULTS: Ninety-five of the 100 embolized catheters and both of the guidewires were successfully retrieved. Retrieval was preceded by repositioning the embolized catheter with a pigtail catheter in 48 of these cases. Most of the procedures were performed with standard vascular tools (loop snares and pigtail catheters); the use of more sophisticated devices (grasping forceps, baskets, or balloons) rarely overcame the failure of a loop snare. Repositioning a migrated catheter tip was achieved with a pigtail catheter in 32 of 38 attempts. Of the repositioned catheters, only 24 could be used. Most of the 11 repositioning and retrieval failures were encountered because the catheter lacked a free end. Fibrin-sheath stripping was always technically successful: all these catheters were patent at 3-month follow-up. No procedure-related complications occurred. CONCLUSION: The endovascular approach is highly feasible, safe, and effective for the management of mechanical complications of central venous devices. It is probably advisable to reserve endovascular repositioning for port catheters that are cumbersome to exchange and to replace simple catheters.


Assuntos
Cateterismo Venoso Central/efeitos adversos , Cateteres de Demora/efeitos adversos , Adolescente , Adulto , Idoso , Cateterismo Venoso Central/instrumentação , Criança , Pré-Escolar , Remoção de Dispositivo , Falha de Equipamento , Feminino , Humanos , Lactente , Masculino , Pessoa de Meia-Idade , Neoplasias/terapia , Radiografia Intervencionista , Estudos Retrospectivos
11.
J Urol ; 167(5): 1961-4, 2002 May.
Artigo em Inglês | MEDLINE | ID: mdl-11956417

RESUMO

PURPOSE: We assess the feasibility, safety and efficacy of radio frequency ablation of small peripheral renal cell carcinomas. MATERIALS AND METHODS: Five patients with a histologically proven renal cell carcinoma 30 to 40 mm. in diameter were treated with radio frequency ablation. A triple needle electrode was percutaneously advanced into each tumor under sonographic (4 cases) or computerized tomography (CT) (1) guidance. The radio frequency generator was activated for 15 minutes in each location where the electrode had been placed. Patients were then followed with CT and blood tests every 2 months for 6 months and every 3 months thereafter. RESULTS: Four tumors required 1 radio frequency delivery and 1 required 2 applications during the same session. No complications were encountered except for a subcapsular hematoma in 1 patient, which resolved spontaneously. Two patients experienced transient hematuria. Of the patients 4 were discharged from the hospital after 2 days and 1 after 1 day. After 6 to 18 months (median 9) all patients were tumor-free on CT without suppress additional treatment. CONCLUSIONS: In this small preliminary study radio frequency ablation of small peripheral renal cell carcinomas appears to be a feasible, safe and promising technique.


Assuntos
Carcinoma de Células Renais/terapia , Hipertermia Induzida , Neoplasias Renais/terapia , Idoso , Idoso de 80 Anos ou mais , Carcinoma de Células Renais/patologia , Estudos de Viabilidade , Feminino , Seguimentos , Humanos , Rim/patologia , Neoplasias Renais/patologia , Masculino , Pessoa de Meia-Idade , Tomografia Computadorizada por Raios X , Resultado do Tratamento , Ultrassonografia
12.
Eur Radiol ; 13(10): 2346-52, 2003 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-12942277

RESUMO

The aim of this study was to test the efficacy of four different radio-frequency ablation (RFA) systems in normal hepatic parenchyma in large animals. The RFA was applied to pig livers in vivo and to calf livers ex vivo using the Radionics cluster needle, RITA starburst XL needle, Radiotherapeutics Le Veen 4.0 needle, and the Berchtold 14-G saline-perfused 15-mm active-tip needle based on constructor specifications. The volume of tissue coagulation from RF was calculated from measurements of the vertical diameter (Dv) and transverse diameter (Dt). Lesion shape was characterized using the ratio between Dt/Dv. Radiotherapeutics and RITA produced in vivo lesion volume of 42+/-10, 39+/-4 cm3 with a reproducible spherical shape (Dt/Dv of 1.01+/-0.16 and 0.97+/-0.1, respectively). Radionics produced in vivo RF lesions volume of 29+/-11 cm3) with an ovoid shape (Dt/Dv 0.88+/-0.09). The RF lesions with the Berchtold device could not be assessed in vivo as 5 of 8 animals died during treatment. Ex vivo RF lesions had similar volumes with each system; however, the Radiotherapeutics device produced more reproducible shaped lesions than the other systems. In our experimental study, we found no difference between expandable needle systems in vivo. Cooled needles produced slightly smaller and ovoid shape in vivo lesions.


Assuntos
Ablação por Cateter/instrumentação , Fígado/lesões , Fígado/cirurgia , Animais , Ablação por Cateter/efeitos adversos , Ablação por Cateter/métodos , Técnicas de Cultura , Eletrodos , Desenho de Equipamento , Segurança de Equipamentos , Feminino , Masculino , Modelos Animais , Medição de Risco , Sensibilidade e Especificidade , Sus scrofa
13.
AJR Am J Roentgenol ; 181(3): 695-700, 2003 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-12933462

RESUMO

OBJECTIVE: We describe the rates and potential risk factors of complications of radiofrequency ablation of hepatic tumors. SUBJECTS AND METHODS. Over a 5-year period, 312 patients underwent 350 sessions of radiofrequency ablation (124 intraoperative and 226 percutaneous) for treatment of 582 liver tumors including 115 hepatocellular carcinomas and 467 metastatic tumors. The chi-square test was used for a group-to-group comparison of the occurrence of adverse events. RESULTS: Thirty-seven (10.6%) adverse events and five (1.4%) deaths were related to radiofrequency treatment. The deaths were caused by liver insufficiency (n = 1), colon perforation (n = 1), and portal vein thrombosis (n = 3). Portal vein thrombosis was significantly (p < 0.00001) more frequent in cirrhotic livers (2/5) than in noncirrhotic livers (0/54) after intraoperative radiofrequency ablation performed during a Pringle maneuver. Liver abscess (n = 7) was the most common complication. Abscess occurred significantly (p < 0.00001) more frequently in patients bearing a bilioenteric anastomosis (3/3) than in other patients (4/223). We encountered five pleural effusions, five skin burns, four hypoxemias, three pneumothoraces, two small subcapsular hematomas, one acute renal insufficiency, one hemoperitoneum, and one needle-tract seeding. The 6.3% of minor complications did not require specific treatment or a prolonged hospital stay. Among the 5.7% major complications, 3.7% required less than 5 days of hospitalization for treatment or surveillance and 2% required more than 5 days for treatment. CONCLUSION: Radiofrequency ablation of liver tumors is a well-tolerated technique, but caution should be exercised when treating patients with a bilioenteric anastomosis, and radiofrequency ablation during vascular occlusion in cirrhotic livers should be avoided.


Assuntos
Carcinoma Hepatocelular/cirurgia , Ablação por Cateter/efeitos adversos , Neoplasias Colorretais/cirurgia , Neoplasias Hepáticas/cirurgia , Complicações Pós-Operatórias , Idoso , Carcinoma Hepatocelular/mortalidade , Carcinoma Hepatocelular/patologia , Ablação por Cateter/mortalidade , Neoplasias Colorretais/mortalidade , Neoplasias Colorretais/patologia , Feminino , Humanos , Tempo de Internação , Neoplasias Hepáticas/mortalidade , Neoplasias Hepáticas/secundário , Imageamento por Ressonância Magnética , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos , Fatores de Risco , Resultado do Tratamento
14.
Radiology ; 223(1): 255-62, 2002 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-11930075

RESUMO

PURPOSE: To describe the appearance of hepatic tumors treated with radio-frequency (RF) ablation on computed tomographic (CT) and magnetic resonance (MR) images and the pattern of residual tumor at the site of RF ablation and to assess prospectively the sensitivity, specificity, and positive and negative predictive CT and MR imaging values in the evaluation of RF treatment. MATERIALS AND METHODS: Thirty-one patients with 50 tumors (nine hepatocellular carcinomas and 41 metastases) treated with RF ablation underwent CT and MR imaging on the same day at 2, 4, and 6 months; CT was performed every 3 months thereafter. CT and MR findings were interpreted separately and prospectively by two reviewers with consensus. For both imaging techniques, appearance of the treated area, treatment efficacy, and complications were assessed at each time. Sensitivity and specificity were determined by using the McNemar test. RESULTS: After a mean follow-up of 19 months, nine tumors showed local regrowth. At 2 months, MR imaging depicted more local regrowths (eight of nine; sensitivity, 89%) than did CT (four of nine; sensitivity, 44%) but without significant differences (P =.12). In two cases, only T2-weighted imaging depicted local regrowth. All nine lesions became conspicuous at 4-month follow-up with both techniques. At 2 months, thin peripheral rim enhancement and arterioportal shunting were found in 24% and 12%, respectively, of the treated tumors. These findings disappeared thereafter and are not linked to tumor regrowth. CONCLUSION: Despite the small number of patients, CT and MR imaging may depicted all local regrowth at 4 months or sooner. MR imaging may have an edge over CT in the early detection of local regrowth.


Assuntos
Ablação por Cateter , Neoplasias Hepáticas/diagnóstico por imagem , Neoplasias Hepáticas/patologia , Imageamento por Ressonância Magnética , Tomografia Computadorizada por Raios X , Adulto , Idoso , Feminino , Seguimentos , Humanos , Neoplasias Hepáticas/cirurgia , Masculino , Pessoa de Meia-Idade , Valor Preditivo dos Testes , Estudos Prospectivos , Sensibilidade e Especificidade
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA