Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 123
Filtrar
1.
Int J Obes (Lond) ; 2024 Jun 19.
Artigo em Inglês | MEDLINE | ID: mdl-38898228

RESUMO

BACKGROUND: Preconception or antenatal lifestyle interventions in women with obesity may prevent adverse cardiovascular outcomes in the child, including cardiac remodelling. We undertook a systematic review of the existing data to examine the impact of randomised controlled trials of lifestyle interventions in pregnant women with obesity on offspring cardiac remodelling and related parameters of cardiovascular health. METHODS: This review was registered with PROSPERO (CRD42023454762) and aligns with PRISMA guidelines. PubMed, Embase, and previous reviews were systematically searched. Follow-up studies from randomised trials of lifestyle interventions in pregnant women with obesity, which included offspring cardiac remodelling or related cardiovascular parameters as outcome measures, were included based on pre-defined inclusion criteria. RESULTS: Eight studies from five randomised controlled trials were included after screening 3252 articles. Interventions included antenatal exercise (n = 2), diet and physical activity (n = 2), and preconception diet and physical activity (n = 1). Children were <2-months to 3-7-years-old, with sample sizes ranging between n = 18-404. Reduced cardiac remodelling, with reduced interventricular septal wall thickness, was consistently reported. Some studies identified improved systolic and diastolic function and a reduced resting heart rate. Risk of bias analyses rated all studies as 'fair' (some risk of bias). A high loss-to-follow-up was a common limitation. CONCLUSION: Although there is some evidence to suggest that lifestyle interventions in women with obesity may limit offspring cardiac remodelling, further high-quality longitudinal studies with larger sample sizes are required to confirm these observations and to determine whether these changes persist to adulthood. Child offspring cardiovascular health benefits of preconception and antenatal lifestyle interventions in women with obesity.

2.
Pediatr Res ; 94(1): 313-320, 2023 07.
Artigo em Inglês | MEDLINE | ID: mdl-36624285

RESUMO

BACKGROUND: Maternal obesity during pregnancy is associated with poorer cardiovascular health (CVH) in children. A strategy to improve CVH in children could be to address preconception maternal obesity by means of a lifestyle intervention. We determined if a preconception lifestyle intervention in women with obesity improved offspring's CVH, assessed by magnetic resonance imaging (MRI). METHODS: We invited children born to women who participated in a randomised controlled trial assessing the effect of a preconception lifestyle intervention in women with obesity. We assessed cardiac structure, function and geometric shape, pulse wave velocity and abdominal fat tissue by MRI. RESULTS: We included 49 of 243 (20.2%) eligible children, 24 girls (49%) girls, mean age 7.1 (0.8) years. Left ventricular ejection fraction was higher in children in the intervention group as compared to children in the control group (63.0% SD 6.18 vs. 58.8% SD 5.77, p = 0.02). Shape analysis showed that intervention was associated with less regional thickening of the interventricular septum and less sphericity. There were no differences in the other outcomes of interest. CONCLUSION: A preconception lifestyle intervention in women with obesity led to a higher ejection fraction and an altered cardiac shape in their offspring, which might suggest a better CVH. IMPACT: A preconception lifestyle intervention in women with obesity results in a higher ejection fraction and an altered cardiac shape that may signify better cardiovascular health (CVH) in their children. This is the first experimental human evidence suggesting an effect of a preconception lifestyle intervention in women with obesity on MRI-derived indicators of CVH in their children. Improving maternal preconception health might prevent some of the detrimental consequences of maternal obesity on CVH in their children.


Assuntos
Obesidade Materna , Humanos , Feminino , Gravidez , Criança , Masculino , Obesidade Materna/complicações , Análise de Onda de Pulso , Volume Sistólico , Cuidado Pré-Concepcional/métodos , Função Ventricular Esquerda , Obesidade/complicações , Obesidade/terapia , Estilo de Vida
4.
J Cardiovasc Magn Reson ; 25(1): 5, 2023 01 30.
Artigo em Inglês | MEDLINE | ID: mdl-36717885

RESUMO

BACKGROUND: Decisions in the management of aortic stenosis are based on the peak pressure drop, captured by Doppler echocardiography, whereas gold standard catheterization measurements assess the net pressure drop but are limited by associated risks. The relationship between these two measurements, peak and net pressure drop, is dictated by the pressure recovery along the ascending aorta which is mainly caused by turbulence energy dissipation. Currently, pressure recovery is considered to occur within the first 40-50 mm distally from the aortic valve, albeit there is inconsistency across interventionist centers on where/how to position the catheter to capture the net pressure drop. METHODS: We developed a non-invasive method to assess the pressure recovery distance based on blood flow momentum via 4D Flow cardiovascular magnetic resonance (CMR). Multi-center acquisitions included physical flow phantoms with different stenotic valve configurations to validate this method, first against reference measurements and then against turbulent energy dissipation (respectively n = 8 and n = 28 acquisitions) and to investigate the relationship between peak and net pressure drops. Finally, we explored the potential errors of cardiac catheterisation pressure recordings as a result of neglecting the pressure recovery distance in a clinical bicuspid aortic valve (BAV) cohort of n = 32 patients. RESULTS: In-vitro assessment of pressure recovery distance based on flow momentum achieved an average error of 1.8 ± 8.4 mm when compared to reference pressure sensors in the first phantom workbench. The momentum pressure recovery distance and the turbulent energy dissipation distance showed no statistical difference (mean difference of 2.8 ± 5.4 mm, R2 = 0.93) in the second phantom workbench. A linear correlation was observed between peak and net pressure drops, however, with strong dependences on the valvular morphology. Finally, in the BAV cohort the pressure recovery distance was 78.8 ± 34.3 mm from vena contracta, which is significantly longer than currently accepted in clinical practise (40-50 mm), and 37.5% of patients displayed a pressure recovery distance beyond the end of the ascending aorta. CONCLUSION: The non-invasive assessment of the distance to pressure recovery is possible by tracking momentum via 4D Flow CMR. Recovery is not always complete at the ascending aorta, and catheterised recordings will overestimate the net pressure drop in those situations. There is a need to re-evaluate the methods that characterise the haemodynamic burden caused by aortic stenosis as currently clinically accepted pressure recovery distance is an underestimation.


Assuntos
Estenose da Valva Aórtica , Doença da Válvula Aórtica Bicúspide , Humanos , Valor Preditivo dos Testes , Estenose da Valva Aórtica/diagnóstico por imagem , Imageamento por Ressonância Magnética/métodos , Valva Aórtica/diagnóstico por imagem , Hemodinâmica , Espectroscopia de Ressonância Magnética , Velocidade do Fluxo Sanguíneo/fisiologia
5.
PLoS Comput Biol ; 17(4): e1008851, 2021 04.
Artigo em Inglês | MEDLINE | ID: mdl-33857152

RESUMO

Cardiac anatomy plays a crucial role in determining cardiac function. However, there is a poor understanding of how specific and localised anatomical changes affect different cardiac functional outputs. In this work, we test the hypothesis that in a statistical shape model (SSM), the modes that are most relevant for describing anatomy are also most important for determining the output of cardiac electromechanics simulations. We made patient-specific four-chamber heart meshes (n = 20) from cardiac CT images in asymptomatic subjects and created a SSM from 19 cases. Nine modes captured 90% of the anatomical variation in the SSM. Functional simulation outputs correlated best with modes 2, 3 and 9 on average (R = 0.49 ± 0.17, 0.37 ± 0.23 and 0.34 ± 0.17 respectively). We performed a global sensitivity analysis to identify the different modes responsible for different simulated electrical and mechanical measures of cardiac function. Modes 2 and 9 were the most important for determining simulated left ventricular mechanics and pressure-derived phenotypes. Mode 2 explained 28.56 ± 16.48% and 25.5 ± 20.85, and mode 9 explained 12.1 ± 8.74% and 13.54 ± 16.91% of the variances of mechanics and pressure-derived phenotypes, respectively. Electrophysiological biomarkers were explained by the interaction of 3 ± 1 modes. In the healthy adult human heart, shape modes that explain large portions of anatomical variance do not explain equivalent levels of electromechanical functional variation. As a result, in cardiac models, representing patient anatomy using a limited number of modes of anatomical variation can cause a loss in accuracy of simulated electromechanical function.


Assuntos
Coração/fisiologia , Modelos Cardiovasculares , Adulto , Voluntários Saudáveis , Coração/anatomia & histologia , Humanos , Tomografia Computadorizada por Raios X
6.
J Cardiovasc Magn Reson ; 24(1): 46, 2022 08 04.
Artigo em Inglês | MEDLINE | ID: mdl-35922806

RESUMO

BACKGROUND: Maladaptive remodelling mechanisms occur in patients with repaired tetralogy of Fallot (rToF) resulting in a cycle of metabolic and structural changes. Biventricular shape analysis may indicate mechanisms associated with adverse events independent of pulmonary regurgitant volume index (PRVI). We aimed to determine novel remodelling patterns associated with adverse events in patients with rToF using shape and function analysis. METHODS: Biventricular shape and function were studied in 192 patients with rToF (median time from TOF repair to baseline evaluation 13.5 years). Linear discriminant analysis (LDA) and principal component analysis (PCA) were used to identify shape differences between patients with and without adverse events. Adverse events included death, arrhythmias, and cardiac arrest with median follow-up of 10 years. RESULTS: LDA and PCA showed that shape characteristics pertaining to adverse events included a more circular left ventricle (LV) (decreased eccentricity), dilated (increased sphericity) LV base, increased right ventricular (RV) apical sphericity, and decreased RV basal sphericity. Multivariate LDA showed that the optimal discriminative model included only RV apical ejection fraction and one PCA mode associated with a more circular and dilated LV base (AUC = 0.77). PRVI did not add value, and shape changes associated with increased PRVI were not predictive of adverse outcomes. CONCLUSION: Pathological remodelling patterns in patients with rToF are significantly associated with adverse events, independent of PRVI. Mechanisms related to incident events include LV basal dilation with a reduced RV apical ejection fraction.


Assuntos
Procedimentos Cirúrgicos Cardíacos , Insuficiência da Valva Pulmonar , Tetralogia de Fallot , Procedimentos Cirúrgicos Cardíacos/efeitos adversos , Humanos , Valor Preditivo dos Testes , Insuficiência da Valva Pulmonar/diagnóstico por imagem , Insuficiência da Valva Pulmonar/etiologia , Insuficiência da Valva Pulmonar/cirurgia , Tetralogia de Fallot/complicações , Tetralogia de Fallot/diagnóstico por imagem , Tetralogia de Fallot/cirurgia , Função Ventricular Direita
7.
Europace ; 24(7): 1137-1147, 2022 07 21.
Artigo em Inglês | MEDLINE | ID: mdl-34907426

RESUMO

AIMS: Remodelling of the left ventricular (LV) shape is one of the hallmarks of non-ischaemic dilated cardiomyopathy (DCM) and may contribute to ventricular arrhythmias and sudden cardiac death. We sought to investigate a novel three dimensional (3D) shape analysis approach to quantify LV remodelling for arrhythmia prediction in DCM. METHODS AND RESULTS: We created 3D LV shape models from end-diastolic cardiac magnetic resonance images of 156 patients with DCM and late gadolinium enhancement (LGE). Using the shape models, principle component analysis, and Cox-Lasso regression, we derived a prognostic LV arrhythmic shape (LVAS) score which identified patients who reached a composite arrhythmic endpoint of sudden cardiac death, aborted sudden cardiac death, and sustained ventricular tachycardia. We also extracted geometrical metrics to look for potential prognostic markers. During a follow-up period of up to 16 years (median 7.7, interquartile range: 3.9), 25 patients met the arrhythmic endpoint. The optimally prognostic LV shape for predicting the time-to arrhythmic event was a paraboloidal longitudinal profile, with a relatively wide base. The corresponding LVAS was associated with arrhythmic events in univariate Cox regression (hazard ratio = 2.0 per quartile; 95% confidence interval: 1.3-2.9), in univariate Cox regression with propensity score adjustment, and in three multivariate models; with LV ejection fraction, New York Heart Association Class III/IV (Model 1), implantable cardioverter-defibrillator receipt (Model 2), and cardiac resynchronization therapy (Model 3). CONCLUSION: Biomarkers of LV shape remodelling in DCM can help to identify the patients at greatest risk of lethal ventricular arrhythmias.


Assuntos
Cardiomiopatia Dilatada , Arritmias Cardíacas/complicações , Arritmias Cardíacas/etiologia , Cardiomiopatia Dilatada/complicações , Cardiomiopatia Dilatada/diagnóstico por imagem , Meios de Contraste , Morte Súbita Cardíaca/etiologia , Fibrose , Gadolínio , Humanos , Valor Preditivo dos Testes , Prognóstico , Volume Sistólico , Função Ventricular Esquerda , Remodelação Ventricular
8.
Cardiovasc Ultrasound ; 20(1): 18, 2022 Jul 16.
Artigo em Inglês | MEDLINE | ID: mdl-35840940

RESUMO

BACKGROUND: Transvalvular pressure drops are assessed using Doppler echocardiography for the diagnosis of heart valve disease. However, this method is highly user-dependent and may overestimate transvalvular pressure drops by up to 54%. This work aimed to assess transvalvular pressure drops using velocity fields derived from blood speckle imaging (BSI), as a potential alternative to Doppler.  METHODS: A silicone 3D-printed aortic valve model, segmented from a healthy CT scan, was placed within a silicone tube. A CardioFlow 5000MR flow pump was used to circulate blood mimicking fluid to create eight different stenotic conditions. Eight PendoTech pressure sensors were embedded along the tube wall to record ground-truth pressures (10 kHz). The simplified Bernoulli equation with measured probe angle correction was used to estimate pressure drop from maximum velocity values acquired across the valve using Doppler and BSI with a GE Vivid E95 ultrasound machine and 6S-D cardiac phased array transducer. RESULTS: There were no significant differences between pressure drops estimated by Doppler, BSI and ground-truth at the lowest stenotic condition (10.4 ± 1.76, 10.3 ± 1.63 vs. 10.5 ± 1.00 mmHg, respectively; p > 0.05). Significant differences were observed between the pressure drops estimated by the three methods at the greatest stenotic condition (26.4 ± 1.52, 14.5 ± 2.14 vs. 20.9 ± 1.92 mmHg for Doppler, BSI and ground-truth, respectively; p < 0.05). Across all conditions, Doppler overestimated pressure drop (Bias = 3.92 mmHg), while BSI underestimated pressure drop (Bias = -3.31 mmHg). CONCLUSIONS: BSI accurately estimated pressure drops only up to 10.5 mmHg in controlled phantom conditions of low stenotic burden. Doppler overestimated pressure drops of 20.9 mmHg. Although BSI offers a number of theoretical advantages to conventional Doppler echocardiography, further refinements and clinical studies are required with BSI before it can be used to improve transvalvular pressure drop estimation in the clinical evaluation of aortic stenosis.


Assuntos
Estenose da Valva Aórtica , Valva Aórtica/diagnóstico por imagem , Estenose da Valva Aórtica/diagnóstico , Velocidade do Fluxo Sanguíneo , Pressão Sanguínea , Ecocardiografia Doppler , Humanos , Silicones
9.
Eur Heart J ; 41(48): 4556-4564, 2020 12 21.
Artigo em Inglês | MEDLINE | ID: mdl-32128588

RESUMO

Providing therapies tailored to each patient is the vision of precision medicine, enabled by the increasing ability to capture extensive data about individual patients. In this position paper, we argue that the second enabling pillar towards this vision is the increasing power of computers and algorithms to learn, reason, and build the 'digital twin' of a patient. Computational models are boosting the capacity to draw diagnosis and prognosis, and future treatments will be tailored not only to current health status and data, but also to an accurate projection of the pathways to restore health by model predictions. The early steps of the digital twin in the area of cardiovascular medicine are reviewed in this article, together with a discussion of the challenges and opportunities ahead. We emphasize the synergies between mechanistic and statistical models in accelerating cardiovascular research and enabling the vision of precision medicine.


Assuntos
Inteligência Artificial , Cardiologia , Algoritmos , Humanos , Medicina de Precisão
10.
PLoS Comput Biol ; 15(10): e1007421, 2019 10.
Artigo em Inglês | MEDLINE | ID: mdl-31658247

RESUMO

This paper presents a morphological analysis of fibrotic scarring in non-ischemic dilated cardiomyopathy, and its relationship to electrical instabilities which underlie reentrant arrhythmias. Two dimensional electrophysiological simulation models were constructed from a set of 699 late gadolinium enhanced cardiac magnetic resonance images originating from 157 patients. Areas of late gadolinium enhancement (LGE) in each image were assigned one of 10 possible microstructures, which modelled the details of fibrotic scarring an order of magnitude below the MRI scan resolution. A simulated programmed electrical stimulation protocol tested each model for the possibility of generating either a transmural block or a transmural reentry. The outcomes of the simulations were compared against morphological LGE features extracted from the images. Models which blocked or reentered, grouped by microstructure, were significantly different from one another in myocardial-LGE interface length, number of components and entropy, but not in relative area and transmurality. With an unknown microstructure, transmurality alone was the best predictor of block, whereas a combination of interface length, transmurality and number of components was the best predictor of reentry in linear discriminant analysis.


Assuntos
Arritmias Cardíacas/patologia , Cardiomiopatia Dilatada/fisiopatologia , Cicatriz/patologia , Arritmias Cardíacas/etiologia , Estudos de Coortes , Simulação por Computador , Humanos , Interpretação de Imagem Assistida por Computador , Modelos Lineares , Imageamento por Ressonância Magnética/métodos , Modelos Teóricos , Infarto do Miocárdio/patologia , Isquemia Miocárdica/patologia , Miocárdio/patologia
11.
Biophys J ; 117(12): 2375-2381, 2019 12 17.
Artigo em Inglês | MEDLINE | ID: mdl-31547974

RESUMO

Cardiac resynchronization therapy (CRT) is an important treatment for heart failure. Low female enrollment in clinical trials means that current CRT guidelines may be biased toward males. However, females have higher response rates at lower QRS duration (QRSd) thresholds. Sex differences in the left ventricle (LV) size could provide an explanation for the improved female response at lower QRSd. We aimed to test if sex differences in CRT response at lower QRSd thresholds are explained by differences in LV size and hence predict sex-specific guidelines for CRT. We investigated the effect that LV size sex difference has on QRSd between male and females in 1093 healthy individuals and 50 CRT patients using electrophysiological computer models of the heart. Simulations on the healthy mean shape models show that LV size sex difference can account for 50-100% of the sex difference in baseline QRSd in healthy individuals. In the CRT patient cohort, model simulations predicted female-specific guidelines for CRT, which were 9-13 ms lower than current guidelines. Sex differences in the LV size are able to account for a significant proportion of the sex difference in QRSd and provide a mechanistic explanation for the sex difference in CRT response. Simulations accounting for the smaller LV size in female CRT patients predict 9-13 ms lower QRSd thresholds for female CRT guidelines.


Assuntos
Terapia de Ressincronização Cardíaca , Simulação por Computador , Guias de Prática Clínica como Assunto , Caracteres Sexuais , Idoso , Feminino , Ventrículos do Coração/patologia , Ventrículos do Coração/fisiopatologia , Humanos , Masculino , Tamanho do Órgão
12.
J Cardiovasc Electrophysiol ; 28(2): 208-215, 2017 02.
Artigo em Inglês | MEDLINE | ID: mdl-27885749

RESUMO

BACKGROUND: Cardiac anatomy and function adapt in response to chronic cardiac resynchronization therapy (CRT). The effects of these changes on the optimal left ventricle (LV) lead location and timing delay settings have yet to be fully explored. OBJECTIVE: To predict the effects of chronic CRT on the optimal LV lead location and device timing settings over time. METHODS: Biophysical computational cardiac models were generated for 3 patients, immediately post-implant (ACUTE) and after at least 6 months of CRT (CHRONIC). Optimal LV pacing area and device settings were predicted by pacing the ACUTE and CHRONIC models across the LV epicardium (49 sites each) with a range of 9 pacing settings and simulating the acute hemodynamic response (AHR) of the heart. RESULTS: There were statistically significant differences between the distribution of the AHR in the ACUTE and CHRONIC models (P < 0.0005 in all cases). The site delivering the maximal AHR shifted location between the ACUTE and CHRONIC models but provided a negligible improvement (<2%). The majority of the acute optimal LV pacing regions (76-100%) and device settings (76-91%) remained optimal chronically. CONCLUSION: Optimization of the LV pacing location and device settings were important at the time of implant, with a reduced benefit over time, where the majority of the acute optimal LV pacing region and device settings remained optimal with chronic CRT.


Assuntos
Terapia de Ressincronização Cardíaca/métodos , Insuficiência Cardíaca/terapia , Modelos Cardiovasculares , Modelagem Computacional Específica para o Paciente , Função Ventricular Esquerda , Potenciais de Ação , Idoso , Mapeamento Epicárdico , Insuficiência Cardíaca/diagnóstico , Insuficiência Cardíaca/fisiopatologia , Frequência Cardíaca , Humanos , Masculino , Pessoa de Meia-Idade , Fatores de Tempo , Resultado do Tratamento
13.
Pediatr Res ; 82(1): 36-46, 2017 07.
Artigo em Inglês | MEDLINE | ID: mdl-28399117

RESUMO

BackgroundAdults born very preterm have increased cardiac mass and reduced function. We investigated whether a hypertrophic phenomenon occurs in later preterm infants and when this occurs during early development.MethodsCardiac ultrasound was performed on 392 infants (33% preterm at mean gestation 34±2 weeks). Scans were performed during fetal development in 137, at birth and 3 months of postnatal age in 200, and during both fetal and postnatal development in 55. Cardiac morphology and function was quantified and computational models created to identify geometric changes.ResultsAt birth, preterm offspring had reduced cardiac mass and volume relative to body size with a more globular heart. By 3 months, ventricular shape had normalized but both left and right ventricular mass relative to body size were significantly higher than expected for postmenstrual age (left 57.8±41.9 vs. 27.3±29.4%, P<0.001; right 39.3±38.1 vs. 16.6±40.8, P=0.002). Greater changes were associated with lower gestational age at birth (left P<0.001; right P=0.001).ConclusionPreterm offspring, including those born in late gestation, have a disproportionate increase in ventricular mass from birth up to 3 months of postnatal age. These differences were not present before birth. Early postnatal development may provide a window for interventions relevant to long-term cardiovascular health.


Assuntos
Cardiomegalia/fisiopatologia , Ventrículos do Coração/crescimento & desenvolvimento , Coração/crescimento & desenvolvimento , Recém-Nascido Prematuro , Antropometria , Peso ao Nascer , Pressão Sanguínea , Tamanho Corporal , Cardiomegalia/diagnóstico por imagem , Simulação por Computador , Ecocardiografia , Feminino , Idade Gestacional , Coração/diagnóstico por imagem , Ventrículos do Coração/diagnóstico por imagem , Humanos , Lactente , Recém-Nascido , Masculino , Fatores de Tempo , Ultrassonografia , Função Ventricular Direita
14.
J Mol Cell Cardiol ; 96: 93-100, 2016 07.
Artigo em Inglês | MEDLINE | ID: mdl-26546827

RESUMO

Cardiac resynchronisation therapy (CRT) is an established treatment for heart failure, however the effective selection of patients and optimisation of therapy remain controversial. While extensive research is ongoing, it remains unclear whether improvements in patient selection or therapy planning offers a greater opportunity for the improvement of clinical outcomes. This computational study investigates the impact of both physiological conditions that guide patient selection and the optimisation of pacing lead placement on CRT outcomes. A multi-scale biophysical model of cardiac electromechanics was developed and personalised to patient data in three patients. These models were separated into components representing cardiac anatomy, pacing lead location, myocardial conductivity and stiffness, afterload, active contraction and conduction block for each individual, and recombined to generate a cohort of 648 virtual patients. The effect of these components on the change in total activation time of the ventricles (ΔTAT) and acute haemodynamic response (AHR) was analysed. The pacing site location was found to have the largest effect on ΔTAT and AHR. Secondary effects on ΔTAT and AHR were found for functional conduction block and cardiac anatomy. The simulation results highlight a need for a greater emphasis on therapy optimisation in order to achieve the best outcomes for patients.


Assuntos
Terapia de Ressincronização Cardíaca , Insuficiência Cardíaca/fisiopatologia , Insuficiência Cardíaca/terapia , Modelos Cardiovasculares , Idoso , Idoso de 80 Anos ou mais , Simulação por Computador , Feminino , Insuficiência Cardíaca/diagnóstico , Hemodinâmica , Humanos , Imageamento por Ressonância Magnética , Masculino , Pessoa de Meia-Idade , Miocárdio/metabolismo , Disfunção Ventricular
15.
J Magn Reson Imaging ; 43(1): 128-37, 2016 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-26114731

RESUMO

BACKGROUND: To determine the inter-study reproducibility of MR feature tracking (MR-FT) derived left ventricular (LV) torsion and torsion rates for a combined assessment of systolic and diastolic myocardial function. METHODS: Steady-state free precession (SSFP) cine LV short-axis stacks were acquired at 9:00 (Exam A), 9:30 (Exam B), and 14:00 (Exam C) in 16 healthy volunteers at 3 Tesla. SSFP images were analyzed offline using MR-FT to assess rotational displacement in apical and basal slices. Global peak torsion, peak systolic and peak diastolic torsion rates were calculated using different definitions ("twist", "normalized twist" and "circumferential-longitudinal (CL) shear angle"). Exam A and B were compared to assess the inter-study reproducibility. Morning and afternoon scans were compared to address possible diurnal variation. RESULTS: The different methods showed good inter-study reproducibility for global peak torsion (intraclass correlation coefficient [ICC]: 0.90-0.92; coefficient of variation [CoV]: 19.0-20.3%) and global peak systolic torsion rate (ICC: 0.82-0.84; CoV: 25.9-29.0%). Conversely, global peak diastolic torsion rate showed little inter-study reproducibility (ICC: 0.34-0.47; CoV: 40.8-45.5%). Global peak torsion as determined by the CL shear angle showed the best inter-study reproducibility (ICC: 0.90;CoV: 19.0%). MR-FT results were not measurably affected by diurnal variation between morning and afternoon scans (CL shear angle: 4.8 ± 1.4°, 4.8 ± 1.5°, and 4.1 ± 1.6° for Exam A, B, and C, respectively; P = 0.21). CONCLUSION: MR-FT based derivation of myocardial peak torsion and peak systolic torsion rate has high inter-study reproducibility as opposed to peak diastolic torsion rate. The CL shear angle was the most reproducible parameter independently of cardiac anatomy and may develop into a robust tool to quantify cardiac rotational mechanics in longitudinal MR-FT patient studies.


Assuntos
Interpretação de Imagem Assistida por Computador/métodos , Reconhecimento Automatizado de Padrão/métodos , Anormalidade Torcional/patologia , Disfunção Ventricular Esquerda/patologia , Adulto , Feminino , Humanos , Masculino , Variações Dependentes do Observador , Reprodutibilidade dos Testes , Sensibilidade e Especificidade
16.
Europace ; 18(suppl 4): iv113-iv120, 2016 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-28011838

RESUMO

AIMS: The efficacy of cardiac resynchronization therapy (CRT) is known to vary considerably with pacing location, however the most effective set of metrics by which to select the optimal pacing site is not yet well understood. Computational modelling offers a powerful methodology to comprehensively test the effect of pacing location in silico and investigate how to best optimize therapy using clinically available metrics for the individual patient. METHODS AND RESULTS: Personalized computational models of cardiac electromechanics were used to perform an in silico left ventricle (LV) pacing site optimization study as part of biventricular CRT in three patient cases. Maps of response to therapy according to changes in total activation time (ΔTAT) and acute haemodynamic response (AHR) were generated and compared with preclinical metrics of electrical function, strain, stress, and mechanical work to assess their suitability for selecting the optimal pacing site. In all three patients, response to therapy was highly sensitive to pacing location, with laterobasal locations being optimal. ΔTAT and AHR were found to be correlated (ρ < -0.80), as were AHR and the preclinical activation time at the pacing site (ρ ≥ 0.73), however pacing in the last activated site did not result in the optimal response to therapy in all cases. CONCLUSION: This computational modelling study supports pacing in laterobasal locations, optimizing pacing site by minimizing paced QRS duration and pacing in regions activated late at sinus rhythm. Results demonstrate information content is redundant using multiple preclinical metrics. Of significance, the correlation of AHR with ΔTAT indicates that minimization of QRSd is a promising metric for optimization of lead placement.


Assuntos
Dispositivos de Terapia de Ressincronização Cardíaca , Terapia de Ressincronização Cardíaca/métodos , Insuficiência Cardíaca/terapia , Modelos Cardiovasculares , Modelagem Computacional Específica para o Paciente , Potenciais de Ação , Idoso , Idoso de 80 Anos ou mais , Técnicas Eletrofisiológicas Cardíacas , Desenho de Equipamento , Feminino , Insuficiência Cardíaca/diagnóstico , Insuficiência Cardíaca/fisiopatologia , Frequência Cardíaca , Humanos , Masculino , Pessoa de Meia-Idade , Valor Preditivo dos Testes , Processamento de Sinais Assistido por Computador , Volume Sistólico , Resultado do Tratamento , Função Ventricular Esquerda
17.
J Cardiovasc Magn Reson ; 17: 36, 2015 May 17.
Artigo em Inglês | MEDLINE | ID: mdl-25982348

RESUMO

BACKGROUND: Cardiovascular magnetic resonance (CMR) offers quantification of phasic atrial functions based on volumetric assessment and more recently, on CMR feature tracking (CMR-FT) quantitative strain and strain rate (SR) deformation imaging. Inter-study reproducibility is a key requirement for longitudinal studies but has not been defined for CMR-based quantification of left atrial (LA) and right atrial (RA) dynamics. METHODS: Long-axis 2- and 4-chamber cine images were acquired at 9:00 (Exam A), 9:30 (Exam B) and 14:00 (Exam C) in 16 healthy volunteers. LA and RA reservoir, conduit and contractile booster pump functions were quantified by volumetric indexes as derived from fractional volume changes and by strain and SR as derived from CMR-FT. Exam A and B were compared to assess the inter-study reproducibility. Morning and afternoon scans were compared to address possible diurnal variation of atrial function. RESULTS: Inter-study reproducibility was within acceptable limits for all LA and RA volumetric, strain and SR parameters. Inter-study reproducibility was better for volumetric indexes and strain than for SR parameters and better for LA than for RA dynamics. For the LA, reservoir function showed the best reproducibility (intraclass correlation coefficient (ICC) 0.94-0.97, coefficient of variation (CoV) 4.5-8.2%), followed by conduit (ICC 0.78-0.97, CoV 8.2-18.5%) and booster pump function (ICC 0.71-0.95, CoV 18.3-22.7). Similarly, for the RA, reproducibility was best for reservoir function (ICC 0.76-0.96, CoV 7.5-24.0%) followed by conduit (ICC 0.67-0.91, CoV 13.9-35.9) and booster pump function (ICC 0.73-0.90, CoV 19.4-32.3). Atrial dynamics were not measurably affected by diurnal variation between morning and afternoon scans. CONCLUSIONS: Inter-study reproducibility for CMR-based derivation of LA and RA functions is acceptable using either volumetric, strain or SR parameters with LA function showing higher reproducibility than RA function assessment. Amongst the different functional components, reservoir function is most reproducibly assessed by either technique followed by conduit and booster pump function, which needs to be considered in future longitudinal research studies.


Assuntos
Função do Átrio Esquerdo , Função do Átrio Direito , Ritmo Circadiano , Imagem Cinética por Ressonância Magnética , Adulto , Fenômenos Biomecânicos , Feminino , Voluntários Saudáveis , Humanos , Masculino , Contração Miocárdica , Variações Dependentes do Observador , Valor Preditivo dos Testes , Reprodutibilidade dos Testes , Estresse Mecânico , Fatores de Tempo , Adulto Jovem
18.
J Cardiovasc Magn Reson ; 17: 61, 2015 Jul 18.
Artigo em Inglês | MEDLINE | ID: mdl-26187817

RESUMO

BACKGROUND: Liver cirrhosis has been shown to affect cardiac performance. However cardiac dysfunction may only be revealed under stress conditions. The value of non-invasive stress tests in diagnosing cirrhotic cardiomyopathy is unclear. We sought to investigate the response to pharmacological stimulation with dobutamine in patients with cirrhosis using cardiovascular magnetic resonance. METHODS: Thirty-six patients and eight controls were scanned using a 1.5 T scanner (Siemens Symphony TIM; Siemens, Erlangen, Germany). Conventional volumetric and feature tracking analysis using dedicated software (CMR42; Circle Cardiovascular Imaging Inc, Calgary, Canada and Diogenes MRI; Tomtec; Germany, respectively) were performed at rest and during low to intermediate dose dobutamine stress. RESULTS: Whilst volumetry based parameters were similar between patients and controls at rest, patients had a smaller increase in cardiac output during stress (p = 0.015). Ejection fraction increase was impaired in patients during 10 µg/kg/min dobutamine as compared to controls (6.9 % vs. 16.5 %, p = 0.007), but not with 20 µg/kg/min (12.1 % vs. 17.6 %, p = 0.12). This was paralleled by an impaired improvement in circumferential strain with low dose (median increase of 14.4 % vs. 30.9 %, p = 0.03), but not with intermediate dose dobutamine (median increase of 29.4 % vs. 33.9 %, p = 0.54). There was an impaired longitudinal strain increase in patients as compared to controls during low (median increase of 6.6 % vs 28.6 %, p < 0.001) and intermediate dose dobutamine (median increase of 2.6%vs, 12.6 % p = 0.016). Radial strain response to dobutamine was similar in patients and controls (p > 0.05). CONCLUSION: Cirrhotic cardiomyopathy is characterized by an impaired cardiac pharmacological response that can be detected with magnetic resonance myocardial stress testing. Deformation analysis parameters may be more sensitive in identifying abnormalities in inotropic response to stress than conventional methods.


Assuntos
Cardiomiopatias/diagnóstico , Cardiotônicos/administração & dosagem , Dobutamina/administração & dosagem , Cirrose Hepática/complicações , Imagem Cinética por Ressonância Magnética/métodos , Contração Miocárdica , Disfunção Ventricular Esquerda/diagnóstico , Disfunção Ventricular Direita/diagnóstico , Função Ventricular Esquerda , Função Ventricular Direita , Idoso , Cardiomiopatias/etiologia , Cardiomiopatias/fisiopatologia , Estudos de Casos e Controles , Feminino , Humanos , Interpretação de Imagem Assistida por Computador , Cirrose Hepática/diagnóstico , Masculino , Pessoa de Meia-Idade , Variações Dependentes do Observador , Valor Preditivo dos Testes , Reprodutibilidade dos Testes , Software , Volume Sistólico , Disfunção Ventricular Esquerda/etiologia , Disfunção Ventricular Esquerda/fisiopatologia , Disfunção Ventricular Direita/etiologia , Disfunção Ventricular Direita/fisiopatologia
19.
Circulation ; 127(2): 197-206, 2013 Jan 15.
Artigo em Inglês | MEDLINE | ID: mdl-23224059

RESUMO

BACKGROUND: Preterm birth leads to an early switch from fetal to postnatal circulation before completion of left ventricular in utero development. In animal studies, this results in an adversely remodeled left ventricle. We determined whether preterm birth is associated with a distinct left ventricular structure and function in humans. METHODS AND RESULTS: A total of 234 individuals 20 to 39 years of age underwent cardiovascular magnetic resonance. One hundred two had been followed prospectively since preterm birth (gestational age=30.3±2.5 week; birth weight=1.3±0.3 kg), and 132 were born at term to uncomplicated pregnancies. Longitudinal and short-axis cine images were used to quantify left ventricular mass, 3-dimensional geometric variation by creation of a unique computational cardiac atlas, and myocardial function. We then determined whether perinatal factors modify these left ventricular parameters. Individuals born preterm had increased left ventricular mass (66.5±10.9 versus 55.4±11.4 g/m(2); P<0.001) with greater prematurity associated with greater mass (r = -0.22, P=0.03). Preterm-born individuals had short left ventricles with small internal diameters and a displaced apex. Ejection fraction was preserved (P>0.99), but both longitudinal systolic (peak strain, strain rate, and velocity, P<0.001) and diastolic (peak strain rate and velocity, P<0.001) function and rotational (apical and basal peak systolic rotation rate, P =0.05 and P =0.006; net twist angle, P=0.02) movement were significantly reduced. A diagnosis of preeclampsia during the pregnancy was associated with further reductions in longitudinal peak systolic strain in the offspring (P=0.02, n=29). CONCLUSIONS: Individuals born preterm have increased left ventricular mass in adult life. Furthermore, they exhibit a unique 3-dimensional left ventricular geometry and significant reductions in systolic and diastolic functional parameters. CLINICAL TRIAL REGISTRATION: URL: http://www.clinicaltrials.gov. Unique identifier: NCT01487824.


Assuntos
Hipertrofia Ventricular Esquerda/epidemiologia , Hipertrofia Ventricular Esquerda/patologia , Recém-Nascido Prematuro , Disfunção Ventricular Esquerda/epidemiologia , Disfunção Ventricular Esquerda/patologia , Adulto , Pressão Sanguínea , Técnicas de Imagem Cardíaca , Diástole , Feminino , Seguimentos , Humanos , Imageamento Tridimensional , Recém-Nascido , Imageamento por Ressonância Magnética , Masculino , Estudos Prospectivos , Fatores de Risco , Sístole , Adulto Jovem
20.
Magn Reson Med ; 72(4): 1162-9, 2014 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-24243444

RESUMO

PURPOSE: To describe the assessment of the spatiotemporal distribution of relative aortic pressure quantifying the magnitude of its three major components. METHODS: Nine healthy volunteers and three patients with aortic disease (bicuspid aortic valve, dissection, and Marfan syndrome) underwent 4D-flow CMR. Spatiotemporal pressure maps were computed from the CMR flow fields solving the pressure Poisson equation. The individual components of pressure were separated into time-varying inertial ("transient"), spatially varying inertial ("convective"), and viscous components. RESULTS: Relative aortic pressure is primarily caused by transient effects followed by the convective and small viscous contributions (64.5, 13.6, and 0.3 mmHg/m, respectively, in healthy subjects), although regional analysis revealed prevalent convective effects in specific contexts, e.g., Sinus of Valsalva and aortic arch at instants of peak velocity. Patients showed differences in peak transient values and duration, and localized abrupt convective changes explained by abnormalities in aortic geometry, including the presence of an aneurysm, a pseudo-coarctation, the inlet of a dissection, or by complex flow patterns. CONCLUSION: The evaluation of the three components of relative pressure enables the quantification of mechanistic information for understanding and stratifying aortic disease, with potential future implications for guiding therapy.


Assuntos
Aorta/fisiopatologia , Doenças da Aorta/fisiopatologia , Pressão Arterial , Interpretação de Imagem Assistida por Computador/métodos , Angiografia por Ressonância Magnética/métodos , Imagem Cinética por Ressonância Magnética/métodos , Imagem de Perfusão do Miocárdio/métodos , Adulto , Doenças da Aorta/diagnóstico , Velocidade do Fluxo Sanguíneo/fisiologia , Determinação da Pressão Arterial/métodos , Circulação Coronária , Feminino , Humanos , Imageamento Tridimensional/métodos , Masculino , Reprodutibilidade dos Testes , Sensibilidade e Especificidade
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA