Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 5 de 5
Filtrar
Mais filtros

Base de dados
Tipo de documento
Ano de publicação
Intervalo de ano de publicação
1.
Eur Radiol ; 29(9): 4624-4634, 2019 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-30758656

RESUMO

OBJECTIVES: To develop and evaluate a method for areal bone mineral density (aBMD) measurement based on dual-layer spectral CT scout scans. METHODS: A post-processing algorithm using a pair of 2D virtual mono-energetic scout images (VMSIs) was established in order to semi-automatically compute the aBMD at the spine similarly to DXA, using manual soft tissue segmentation, semi-automatic segmentation for the vertebrae, and automatic segmentation for the background. The method was assessed based on repetitive measurements of the standardized European Spine Phantom (ESP) using the standard scout scan tube current (30 mA) and other tube currents (10 to 200 mA), as well as using fat-equivalent extension rings simulating different patient habitus, and was compared to dual-energy X-ray absorptiometry (DXA). Moreover, the feasibility of the method was assessed in vivo in female patients. RESULTS: Derived from standard scout scans, aBMD values measured with the proposed method significantly correlated with DXA measurements (r = 0.9925, p < 0.001), and mean accuracy (DXA, 4.12%; scout, 1.60%) and precision (DXA, 2.64%; scout, 2.03%) were comparable between the two methods. Moreover, aBMD values assessed at different tube currents did not differ significantly (p ≥ 0.20 for all), suggesting that the presented method could be applied to scout scans with different settings. Finally, data derived from sample patients were concordant with BMD values from a reference age-matched population. CONCLUSIONS: Based on dual-layer spectral scout scans, aBMD measurements were fast and reliable and significantly correlated with the according DXA measurements in phantoms. Considering the number of CT acquisitions performed worldwide, this method could allow truly opportunistic osteoporosis screening. KEY POINTS: • 2D scout scans (localizer radiographs) from a dual-layer spectral CT scanner, which are mandatory parts of a CT examination, can be used to automatically determine areal bone mineral density (aBMD) at the spine. • The presented method allowed fast (< 25 s/patient), semi-automatic, and reliable DXA-equivalent aBMD measurements for state-of-the-art DXA phantoms at different tube settings and for various patient habitus, as well as for sample patients. • Considering the number of CT scout scan acquisitions performed worldwide on a daily basis, the presented technique could enable truly opportunistic osteoporosis screening with DXA-equivalent metrics, without involving higher radiation exposure since it only processes existing data that is acquired during each CT scan.


Assuntos
Densidade Óssea/fisiologia , Osteoporose/diagnóstico por imagem , Tomografia Computadorizada por Raios X/métodos , Adulto , Fatores Etários , Idoso , Algoritmos , Estudos de Viabilidade , Feminino , Humanos , Processamento de Imagem Assistida por Computador/métodos , Pessoa de Meia-Idade , Imagens de Fantasmas , Reprodutibilidade dos Testes , Coluna Vertebral/diagnóstico por imagem , Adulto Jovem
2.
Eur Radiol ; 29(11): 6355-6363, 2019 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-31115622

RESUMO

OBJECTIVE: To investigate the in vivo applicability of non-contrast-enhanced hydroxyapatite (HA)-specific bone mineral density (BMD) measurements based on dual-layer CT (DLCT). METHODS: A spine phantom containing three artificial vertebral bodies with known HA densities was measured to obtain spectral data using DLCT and quantitative CT (QCT), simulating different patient positions and grades of obesity. BMD was calculated from virtual monoenergetic images at 50 and 200 keV. HA-specific BMD values of 174 vertebrae in 33 patients (66 ± 18 years; 33% women) were determined in non-contrast routine DLCT and compared with corresponding QCT-based BMD values. RESULTS: Examining the phantom, HA-specific BMD measurements were on a par with QCT measurements. In vivo measurements revealed strong correlations between DLCT and QCT (r = 0.987 [95% confidence interval, 0.963-1.000]; p < 0.001) and substantial agreement in a Bland-Altman plot. CONCLUSION: DLCT-based HA-specific BMD measurements were comparable with QCT measurements in in vivo analyses. This suggests that opportunistic DLCT-based BMD measurements are an alternative to QCT, without requiring phantoms and specific protocols. KEY POINTS: • DLCT-based hydroxyapatite-specific BMD measurements show a substantial agreement with QCT-based BMD measurements in vivo. • DLCT-based hydroxyapatite-specific measurements are on a par with QCT in spine phantom measurements. • Opportunistic DLCT-based BMD measurements may be a feasible alternative for QCT, without requiring dedicated examination protocols or a phantom.


Assuntos
Absorciometria de Fóton/métodos , Densidade Óssea/fisiologia , Osteoporose/diagnóstico por imagem , Coluna Vertebral/diagnóstico por imagem , Tomografia Computadorizada por Raios X/métodos , Adulto , Algoritmos , Feminino , Humanos , Masculino , Programas de Rastreamento/métodos , Pessoa de Meia-Idade , Osteoporose/fisiopatologia , Imagens de Fantasmas
3.
Biomed Phys Eng Express ; 6(5): 055021, 2020 09 08.
Artigo em Inglês | MEDLINE | ID: mdl-33444252

RESUMO

OBJECTIVES: To study whether a dual-layer spectral CT scout scan-based areal BMD estimation method, called Spectral-detector based x-ray absorptiometry (SDXA), can differentiate patients with versus without osteoporotic fractures. METHODS: The ability of the method to differentiate patients with osteoporosis was evaluated by assessing the areal BMD at the spine (L1 to L4) in a group of 19 patients presenting at least one fracture and comparing these results to the areal BMD of age- and gender-matched controls (57 patients). Finally, the reproducibility of SDXA was evaluated in-vivo through the calculation of coefficients of variation (CV), using three repeated analyses performed on each patient. RESULTS: The average areal BMD of patients presenting fractures, measured with the scout scan-based method (0.86 ± 0.17 g cm-2), was found to be significantly lower than the average BMD of the control group (1.00 ± 0.17 g cm-2, p = 0.043). The reproducibility of the method in-vivo was found to be reasonable, with CVs ranging between 3.1 and 6.9%. CONCLUSIONS: The results illustrate that the SDXA method for DXA-equivalent areal BMD estimation -delivers the ability to distinguish patients presenting osteoporotic fractures. Considering the total number of CT examinations worldwide, SDXA could develop to be a useful tool for truly opportunistic osteoporosis screening for a future clinical day-to-day routine.


Assuntos
Absorciometria de Fóton/métodos , Densidade Óssea , Osteoporose/patologia , Fraturas por Osteoporose/patologia , Tomografia Computadorizada por Raios X/métodos , Idoso , Estudos de Casos e Controles , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Osteoporose/diagnóstico por imagem , Fraturas por Osteoporose/diagnóstico por imagem
4.
Sci Rep ; 9(1): 8458, 2019 06 11.
Artigo em Inglês | MEDLINE | ID: mdl-31186467

RESUMO

Diagnostic imaging of hepatocellular carcinoma (HCC) requires a liver CT or MRI multiphase acquisition protocol. Patients would benefit from a high-resolution imaging method capable of performing multi-phase imaging in a single acquisition without an increase in radiation dose. Spectral Photon-Counting Computed Tomography (SPCCT) has recently emerged as a novel and promising imaging modality in the field of diagnostic radiology. SPCCT is able to distinguish between two contrast agents referred to as multicolor imaging because, when measuring in three or more energy regimes, it can detect and quantify elements with a K-edge in the diagnostic energy range. Based on this capability, we tested the feasibility of a dual-contrast multi-phase liver imaging protocol via the use of iodinated and gadolinated contrast agents on four healthy New Zealand White (NZW) rabbits. To perform a dual-contrast protocol, we injected the agents at different times so that the first contrast agent visualized the portal phase and the second the arterial phase, both of which are mandatory for liver lesion characterization. We demonstrated a sensitive discrimination and quantification of gadolinium within the arteries and iodine within the liver parenchyma. In the hepatic artery, the concentration of gadolinium was much higher than iodine (8.5 ± 3.9 mg/mL versus 0.7 ± 0.1 mg/mL) contrary to the concentrations found in the liver parenchyma (0.5 ± 0.3 mg/mL versus 4.2 ± 0.3 mg/mL). In conclusion, our results confirm that SPCCT allows in-vivo dual contrast qualitative and quantitative multi-phase liver imaging in a single acquisition.


Assuntos
Abdome/diagnóstico por imagem , Absorciometria de Fóton , Fígado/diagnóstico por imagem , Tomografia Computadorizada por Raios X , Abdome/patologia , Animais , Carcinoma Hepatocelular/diagnóstico por imagem , Carcinoma Hepatocelular/patologia , Meios de Contraste/farmacologia , Modelos Animais de Doenças , Gadolínio/farmacologia , Humanos , Iodo/farmacologia , Fígado/patologia , Neoplasias Hepáticas/diagnóstico por imagem , Neoplasias Hepáticas/patologia , Imageamento por Ressonância Magnética/métodos , Imagens de Fantasmas , Fótons , Coelhos
5.
Sci Rep ; 9(1): 5837, 2019 04 09.
Artigo em Inglês | MEDLINE | ID: mdl-30967601

RESUMO

Dual-Energy Computed Tomography is of significant clinical interest due to the possibility of material differentiation and quantification. In current clinical routine, primarily two materials are differentiated, e.g., iodine and soft-tissue. A ventilation-perfusion-examination acquired within a single CT scan requires two contrast agents, e.g., xenon and gadolinium, and a three-material differentiation. In the current study, we have developed a solution for three-material differentiation for a ventilation-perfusion-examination. A landrace pig was examined using a dual-layer CT, and three scans were performed: (1) native; (2) xenon ventilation only; (3) xenon ventilation and gadolinium perfusion. An in-house developed algorithm was used to obtain xenon- and gadolinium-density maps. Firstly, lung tissue was segmented from other tissue. Consequently, a two-material decomposition was performed for lung tissue (xenon/soft-tissue) and for remaining tissue (gadolinium/soft-tissue). Results reveal that it was possible to differentiate xenon and gadolinium in a ventilation/perfusion scan of a pig, resulting in xenon and gadolinium density maps. By summation of both density maps, a three-material differentiation (xenon/gadolinium/soft tissue) can be performed and thus, xenon ventilation and gadolinium perfusion can be visualized in a single CT scan. In an additionally performed phantom study, xenon and gadolinium quantification showed very accurate results (r > 0.999 between measured and known concentrations).


Assuntos
Pulmão/diagnóstico por imagem , Tomografia Computadorizada por Raios X/métodos , Algoritmos , Animais , Estudos de Viabilidade , Suínos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA