Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 23
Filtrar
1.
Sensors (Basel) ; 23(13)2023 Jul 01.
Artigo em Inglês | MEDLINE | ID: mdl-37447934

RESUMO

In this paper, a capacitively-fed, ultra-wideband (UWB), and low-profile monocone antenna is proposed for vehicle-to-everything (V2X) applications. The proposed antenna consists of a monocone design with an inner set of vias. Additionally, an outer ring is added with a small gap from the monocone and shorted with six folded wires of different lengths to extend the operating band. The proposed antenna covers the frequency range from 0.75 GHz to 7.6 GHz and has a 164% fractional bandwidth, with a gain value varying between 2 and 10 dBi. The dimensions of the antenna are 0.37λL × 0.37λL × 0.067λL. The antenna was fabricated using a 3D printer with low-cost polylactic acid plastic (PLA) material and then sprayed with aerosol copper nanoparticles. The efficiency was approximately 90% throughout the frequency bands of interest. Finally, the proposed antenna was installed on a vehicle and tested with an OBU (onboard unit) and a RSU (roadside unit) in the field. The results show a longer wireless communication range for V2X applications.


Assuntos
Comunicação , Nanopartículas , Cobre , Plásticos
2.
Sensors (Basel) ; 21(5)2021 Mar 06.
Artigo em Inglês | MEDLINE | ID: mdl-33800771

RESUMO

This review paper focuses on radio-frequency (RF) biosensors for real-time and continuous glucose sensing reported in the literature, including our recent research. Diverse versions of glucose biosensors based on RF devices and circuits are briefly introduced, and their performances are compared. In addition, the limitations of the developed RF glucose biosensors are discussed. Finally, we present perspectives on state-of-art RF biosensing chips for point-of-care diagnosis and describe their future challenges.


Assuntos
Técnicas Biossensoriais , Glucose , Sistemas Automatizados de Assistência Junto ao Leito , Ondas de Rádio
3.
Environ Monit Assess ; 193(9): 601, 2021 Aug 26.
Artigo em Inglês | MEDLINE | ID: mdl-34436638

RESUMO

Invasion of alien species facilitated by climate change and human assistant is one of global threats that cause irreversible damages on the local flora and fauna. One of these issued species, Vespa velutina nigrithorax du Buysson, 1905 (Hymenoptera:Vespidae), is a significant threat to entomofauna, including honeybees, in the introduced regions. This wasp is still expanding its habitats, prioritizing the development of a reliable species distribution model based on recently updated occurrence data. Therefore, the aim of this study was to evaluate the potential areas that are climatically exposed to V. v. nigrithorax invasion globally and in South Korea, where the wasp has caused severe damage to local ecosystems and apiculture after its recent introduction. We developed a new global scale ensemble model based on CLIMEX and Maxent models and applied it to South Korea using field survey data. As a result, risky areas were predicted to be temperate and subtropical climate regions, including the eastern USA, western Europe, Far East Asia, and small areas in South America and Australia. In particular, South Korea has a high potential risk throughout the country. We expect that this study would provide fundamental data for monitoring the environmental risks caused by V. v. nigrithorax using advanced species distribution modeling.


Assuntos
Vespas , Animais , Abelhas , Ecossistema , Monitoramento Ambiental , Europa (Continente) , Humanos , Espécies Introduzidas
4.
Sensors (Basel) ; 18(11)2018 Nov 09.
Artigo em Inglês | MEDLINE | ID: mdl-30423976

RESUMO

In this paper, a fluidic glucose sensor that is based on a complementary split-ring resonator (CSRR) is proposed for the microwave frequency region. The detection of glucose with different concentrations from 0 mg/dL to 400 mg/dL in a non-invasive manner is possible by introducing a fluidic system. The glucose concentration can be continuously monitored by tracking the transmission coefficient S 21 as a sensing parameter. The variation tendency in S 21 by the glucose concentration is analyzed with equivalent circuit model. In addition, to eradicate the systematic error due to temperature variation, the sensor is tested in two temperature conditions: the constant temperature condition and the time-dependent varying temperature condition. For the varying temperature condition, the temperature correction function was derived between the temperature and the variation in S 21 for DI water. By applying the fitting function to glucose solution, the subsidiary results due to temperature can be completely eliminated. As a result, the S 21 varies by 0.03 dB as the glucose concentration increases from 0 mg/dL to 400 mg/dL.

5.
J Forensic Sci ; 68(5): 1741-1754, 2023 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-37435911

RESUMO

Digital video is used in criminal trials as evidence with legal responsibility because video content vividly depicts events occurring at a crime scene. However, using sophisticated video editing software, assailants can easily manipulate visible clues for their own benefit. Therefore, the integrity of digital video files acquired or submitted as evidence must be ensured. Forensic analysis of digital video is key to ensuring the integrity of links with individual cameras. In this study, we analyzed whether it is possible to ensure the integrity of MTS video files. Herein, we propose a method to verify the integrity of MTS files encoded by advanced video coding high definition (AVCHD), which is frequently used for video recording. To verify MTS file integrity, we propose five features. Codec information, picture timing, and camera manufacture/model are modified AVI and MP4-like format video verification features. Group of pictures and Universally Unique Identifier patterns were specifically developed for MTS streams. We analyzed the features of 44 standard files recorded using all recording options of seven cameras. We checked whether integrity can be validated on unmanipulated videos recorded in various environments. In addition, we considered whether manipulated MTS files edited in video editing software could be validated. Experimental results show that all unmanipulated and manipulated MTS files with known recording devices were discriminated only when all five features were checked. These results show that the proposed method verifies the integrity of MTS files, strengthening the validity of MTS file-based evidence in trials.

6.
Healthcare (Basel) ; 10(5)2022 Apr 21.
Artigo em Inglês | MEDLINE | ID: mdl-35627908

RESUMO

Although data-based healthcare innovation has been spotlighted in South Korea in recent years, previous studies have made little effort to systematically predict various possible future outcomes in the data-driven healthcare economy. This study investigated possible future such scenarios in South Korea by conducting a general morphological analysis (GMA). Seven key factors were identified that will drive the data-driven healthcare economy: the acceptability of data utilization, the level of data literacy, the status of healthcare data regulation, the healthcare data system, medical costs, the convergence of ICT and biotechnology, and the utilization of data in medical services. The main findings are as follows: Four possible scenarios for the data-driven healthcare economy in South Korea were identified. The first scenario suggested mostly optimistic prospects and close associations between factorial values on the various spectra. The second scenario was similar to the first one, except for medical costs. However, the third scenario contrasted with the first, as it entailed relatively pessimistic factorial values. Finally, most of the elements of the current healthcare status quo were maintained in the fourth scenario. This study makes not only an academic contribution, but also has policy implications based on the four scenarios.

7.
Biodivers Data J ; 10: e81941, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-36761583

RESUMO

We investigated the identity and distribution of the invasive alien insect species inhabiting Korean ecosystems, targeting 3,249 locations in nine regions between 2015 and 2018. In natural ecosystems, we identified 63 species in 43 families and nine orders of invasive alien insect species, respectively. We observed that the order Hemiptera exhibited the highest species diversity with 20 species. Gyeonggi-do was where the highest number of invasive alien insect species were identified (45 species). Species richness analysis revealed that Jeju-do showed the highest Dominance Index (0.8), whereas Gyeongsangnam-do had the highest Diversity Index (2.8). Corythuchamarmorata (Hemiptera: Tingidae), Lycormadelicatula (Hemiptera: Fulgoridae), Ophraellacommuna (Coleoptera: Chrysomeridae), Metcalfapruinosa (Say) (Hemiptera: Flatidae) and Pochaziashantungensis (Hemiptera: Ricaniidae) were distributed in more than 300 locations of the country. Invasive alien insect species inhabited the roadsides (31.3%), farmlands (18.3%) and parks (16.6%). In this study, we list the invasive alien insect species in Korean ecosystems and provide a basis for selecting primary management target species.

8.
Environ Sci Pollut Res Int ; 29(8): 11990-12008, 2022 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-34558045

RESUMO

The aim of this study was to characterize the physicochemical properties and microbial communities of particulate matter (PM) in Seoul, Korea. We collected long-term (2017-2019) precipitation samples and PM10 and PM2.5 monitoring data to determine the impact of soluble and insoluble chemical species on the soil surface. Ambient PM10 concentrations were higher than PM2.5 concentrations during the monitoring period, but both decreased during rainfall due to the washing effect of precipitation. PM2.5 particles had a "fluffy" shape and contained sulfur (0.2%), but suspended particles (SPs) contained many carbon particles (approximately 60%). Spherical particles containing metal oxides, Fe and Al, might be originated from coal combustion, wild fires, and metal-refining processes under high-temperature conditions. Dissolved ions in precipitation included those eluted from salts and coal combustion based on the correlation coefficients of Na and Cl (R = 0.953) and F and NO3 (R = 0.706). The δ15N-NO3 and δ34S-SO4 of precipitation were enriched as the atmospheric temperature decreased from 9.8 to -1.6°C, implying the influence of domestic coal combustion. Backward trajectories showed that, in winter, air parcels passed through industrialized cities from China to South Korea. The microbial communities associated with PM were strongly influenced by atmospheric conditions. Proteobacteria (range from 4.6 to 76.7%) and Firmicutes (range from 6.0 to 91.4%) were the most dominant phyla and were significantly affected by changes in the PM2.5 environment. The results indicate that the acidity of precipitation and the composition of aerosols were affected by fossil fuel combustion and mineral dust, and that atmospheric conditions may change as PM2.5 concentrations increase.


Assuntos
Poluentes Atmosféricos , Aerossóis/análise , Poluentes Atmosféricos/análise , China , Monitoramento Ambiental , Tamanho da Partícula , Material Particulado/análise , Estações do Ano , Seul , Emissões de Veículos/análise
9.
IEEE Trans Biomed Circuits Syst ; 15(5): 1017-1026, 2021 10.
Artigo em Inglês | MEDLINE | ID: mdl-34570708

RESUMO

In this paper, a microwave fluidic glucose sensor based on a microwave resonator coupled with an interferometric system is proposed for sensitivity enhancement. The proposed glucose sensor consists of two parts: a sensing part and a sensitivity enhancement part. The former is composed of a rectangular complementary split ring resonator (CSRR), and the latter is composed of a variable attenuator, a variable phase shifter, two hybrid couplers, and an RF power detector. Because the variation in the electrical properties, which is utilized in the microwave detection scheme, with glucose concentration over the possible concentration range in the human body is very small, improvement of the sensitivity is critical for practical use. Thus, the effective sensing area of the rectangular CSRR is determined by considering the electric field distribution. In addition, magnitude and phase conditions for the effective sensitivity enhancement are derived from a mathematical analysis of the proposed interferometric system. In the present experiment, aimed at demonstrating the detection performance as a function of the glucose concentration in the range of 0 mg/dL to 400 mg/dL, the sensitivity is significantly improved by 48 times by applying the derived conditions for effective sensitivity enhancement. Furthermore, the accuracy of the proposed glucose sensor for glucose concentrations at a step of 100 mg/dL is verified by the Clarke error grid. Based on the measurement results, the proposed glucose sensor is demonstrated to be applicable to noninvasive and continuous monitoring in practical environments.


Assuntos
Técnicas Biossensoriais , Micro-Ondas , Eletricidade , Glucose , Humanos
10.
Sensors (Basel) ; 10(4): 3911-33, 2010.
Artigo em Inglês | MEDLINE | ID: mdl-22319333

RESUMO

Wireless body area networks (WBAN) consist of resource constrained sensing devices just like other wireless sensor networks (WSN). However, they differ from WSN in topology, scale and security requirements. Due to these differences, key management schemes designed for WSN are inefficient and unnecessarily complex when applied to WBAN. Considering the key management issue, WBAN are also different from WPAN because WBAN can use random biometric measurements as keys. We highlight the differences between WSN and WBAN and propose an efficient key management scheme, which makes use of biometrics and is specifically designed for WBAN domain.


Assuntos
Biometria/instrumentação , Biometria/métodos , Redes de Comunicação de Computadores , Simulação por Computador , Desenho de Equipamento , Corpo Humano , Matemática/métodos , Tecnologia sem Fio/instrumentação
11.
Sensors (Basel) ; 10(3): 1447-72, 2010.
Artigo em Inglês | MEDLINE | ID: mdl-22294881

RESUMO

Full network level privacy has often been categorized into four sub-categories: Identity, Route, Location and Data privacy. Achieving full network level privacy is a critical and challenging problem due to the constraints imposed by the sensor nodes (e.g., energy, memory and computation power), sensor networks (e.g., mobility and topology) and QoS issues (e.g., packet reach-ability and timeliness). In this paper, we proposed two new identity, route and location privacy algorithms and data privacy mechanism that addresses this problem. The proposed solutions provide additional trustworthiness and reliability at modest cost of memory and energy. Also, we proved that our proposed solutions provide protection against various privacy disclosure attacks, such as eavesdropping and hop-by-hop trace back attacks.


Assuntos
Segurança Computacional , Telemetria , Algoritmos , Redes de Comunicação de Computadores , Geografia , Humanos , Modelos Teóricos
12.
Materials (Basel) ; 13(7)2020 Apr 09.
Artigo em Inglês | MEDLINE | ID: mdl-32283760

RESUMO

This study aims to investigate the microwave properties of coplanar waveguide (CPW)-based poly(3,4-ethylenedioxythiophene) polystyrene sulfonate (PEDOT:PSS) conducting polymer line in an ethanol gas atmosphere, with the frequency range of 0.5-2 GHz. For an ethanol-exposed PEDOT:PSS line (test sample), the transmission coefficient (S21) decreased immediately; moreover, the microwave effective conductivity (σm/w) decreased simultaneously, compared with the ethanol-free PEDOT:PSS line (reference sample). The immediate variations in ΔS21 ( = S21,ethanol - S21,free) and Δσm/w ( = σm/w,ethanol - σm/w,free) were approximately 10.2 dB and 2.7 × 104 S/m, respectively. Furthermore, in the analysis of the circuit model of the PEDOT:PSS line, the characteristic impedance and distributed elements, i.e., resistance (R) and inductance (L) per length, of the test sample increased, compared with the reference sample. However, upon stopping the exposure to ethanol gas, the microwave properties of the test sample instantaneously recovered to those of the reference sample. According to these critical observations, we could confirm that the coplanar waveguide with a PEDOT:PSS line shows a significant difference in the diverse microwave properties, through rapid response to the ethanol gas at room temperature.

13.
Materials (Basel) ; 13(12)2020 Jun 25.
Artigo em Inglês | MEDLINE | ID: mdl-32630590

RESUMO

In this review, the advances in radio-frequency (RF) /microwave chemical gas sensors using conducting polymers are discussed. First, the introduction of various conducting polymers is described. Only polyaniline (PANi), polypyrrole (PPy) and poly(3,4-ethylenedioxythiophene) (PEDOT), which are mainly used for gas sensors in RF/microwave region, are focused in this review. Sensing mechanism of the three conducting polymers are presented. And the RF/microwave characteristics and RF/microwave applications of the three conducting polymers are discussed. Moreover, the gas sensors using conducting polymers in RF/microwave frequencies are described. Finally, the the challenges and the prospects of the next generation of the RF/microwave based chemical sensors for wireless applications are proposed.

14.
Sensors (Basel) ; 9(8): 5989-6007, 2009.
Artigo em Inglês | MEDLINE | ID: mdl-22454568

RESUMO

Existing anomaly and intrusion detection schemes of wireless sensor networks have mainly focused on the detection of intrusions. Once the intrusion is detected, an alerts or claims will be generated. However, any unidentified malicious nodes in the network could send faulty anomaly and intrusion claims about the legitimate nodes to the other nodes. Verifying the validity of such claims is a critical and challenging issue that is not considered in the existing cooperative-based distributed anomaly and intrusion detection schemes of wireless sensor networks. In this paper, we propose a validation algorithm that addresses this problem. This algorithm utilizes the concept of intrusion-aware reliability that helps to provide adequate reliability at a modest communication cost. In this paper, we also provide a security resiliency analysis of the proposed intrusion-aware alert validation algorithm.

15.
Materials (Basel) ; 12(6)2019 Mar 21.
Artigo em Inglês | MEDLINE | ID: mdl-30901965

RESUMO

In this paper, the advances in radio-frequency (RF)/microwave biosensors based on graphene nanomaterials including graphene, graphene oxide (GO), and reduced graphene oxide (rGO) are reviewed. From a few frontier studies, recently developed graphene nanomaterials-based RF/microwave biosensors are examined in-depth and discussed. Finally, the prospects and challenges of the next-generation RF/microwave biosensors for wireless biomedical applications are proposed.

16.
IEEE Trans Biomed Circuits Syst ; 13(3): 493-502, 2019 06.
Artigo em Inglês | MEDLINE | ID: mdl-30946676

RESUMO

In this paper, a radio frequency vital sign sensor based on double voltage-controlled oscillators (VCOs) combined with a switchable phase-locked loop (PLL) is proposed for a noncontact remote vital sign sensing system. Our sensing system primarily detects the periodic movements of the human lungs and the hearts via the impedance variation of the resonator. With a change in impedance, both the VCO oscillation frequency and the PLL feedback voltage also change. Thus, by tracking the feedback voltage of the PLL, breath and heart rate signals can be acquired simultaneously. However, as the distance between the body and the sensor varies, there are certain points with minimal sensitivity, making it is quite difficult to detect vital signs. These points, called impedance null points, periodically occur at distances proportional to the wavelength. To overcome the impedance null point problem, two resonators operating at different frequencies, 2.40 and 2.76 GHz, are employed as receiving components. In an experiment to investigate the sensing performance as a function of distance, the measurement distance was accurately controlled by a linear actuator. Furthermore, to evaluate the sensing performance in a real environment, experiments were carried out with a male and a female subject in a static vehicle. To demonstrate the real-time vital sign monitoring capability, spectrograms were utilized, and the accuracy was assessed relative to reference sensors. Based on the results, it is demonstrated that the proposed remote sensor can reliably detect vital signs in a real vehicle environment.


Assuntos
Condução de Veículo , Desenho de Equipamento , Frequência Cardíaca , Mecânica Respiratória , Dispositivos Eletrônicos Vestíveis , Feminino , Humanos , Masculino
17.
Sensors (Basel) ; 8(12): 7753-7782, 2008 Dec 03.
Artigo em Inglês | MEDLINE | ID: mdl-27873956

RESUMO

For many sensor network applications such as military or homeland security, it is essential for users (sinks) to access the sensor network while they are moving. Sink mobility brings new challenges to secure routing in large-scale sensor networks. Previous studies on sink mobility have mainly focused on efficiency and effectiveness of data dissemination without security consideration. Also, studies and experiences have shown that considering security during design time is the best way to provide security for sensor network routing. This paper presents an energy-efficient secure routing and key management for mobile sinks in sensor networks, called SCODEplus. It is a significant extension of our previous study in five aspects: (1) Key management scheme and routing protocol are considered during design time to increase security and efficiency; (2) The network topology is organized in a hexagonal plane which supports more efficiency than previous square-grid topology; (3) The key management scheme can eliminate the impacts of node compromise attacks on links between non-compromised nodes; (4) Sensor node deployment is based on Gaussian distribution which is more realistic than uniform distribution; (5) No GPS or like is required to provide sensor node location information. Our security analysis demonstrates that the proposed scheme can defend against common attacks in sensor networks including node compromise attacks, replay attacks, selective forwarding attacks, sinkhole and wormhole, Sybil attacks, HELLO flood attacks. Both mathematical and simulation-based performance evaluation show that the SCODEplus significantly reduces the communication overhead, energy consumption, packet delivery latency while it always delivers more than 97 percent of packets successfully.

18.
Sci Rep ; 8(1): 439, 2018 01 11.
Artigo em Inglês | MEDLINE | ID: mdl-29323214

RESUMO

A real-time humidity sensor based on a microwave resonator coupled with a poly(3,4-ethylenedioxythiophene) polystyrene sulfonate (PEDOT:PSS) conducting polymer (CP) film is proposed in this paper. The resonator is patterned on a printed circuit board and is excited by electromagnetic field coupling. To enhance the sensitivity of the sensor, the CP film is located in the area with the strongest electric field in the resonator. To investigate the performance, the proposed sensor is placed alongside a reference sensor in a humidity chamber, and humidity is injected at room temperature. The experimental results indicate that the electrical properties of the resonator with the CP film, such as the transmission coefficient (S 21) and resonance frequency, change with the relative humidity (RH). Specifically, as the RH changes from 5% to 80%, S 21 and the resonance frequency change simultaneously. Moreover, the proposed sensor exhibits great repeatability in the middle of the sensing range, which is from 40% to 60% RH. Consequently, our resonator coupled with the CP film can be used as a real-time humidity-sensing device in the microwave range, where various radio-frequency devices are in use.

19.
Rev Sci Instrum ; 87(9): 094706, 2016 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-27782576

RESUMO

In this paper, we demonstrate the sensing feasibility of the proposed high-Q resonator using a phosphate-buffered saline droplet at microwave frequencies. In the experimental results, the resonant frequency, signal level, and Q-factor of the S21-parameter with and without a 1-µl droplet were changed to about 230 MHz, 32 dB, and 1500, respectively. The resonator system was found to be suitable for droplet sensing with a small volume due to its small and compact scheme. This resonator system is expected to play an important role in droplet sensing with different dielectric constants.

20.
Biosens Bioelectron ; 61: 448-59, 2014 Nov 15.
Artigo em Inglês | MEDLINE | ID: mdl-24934746

RESUMO

This article reviews radio-frequency (RF) biosensors based on passive and/or active devices and circuits. In particular, we focus on RF biosensors designed for detection of various biomolecules such as biotin-streptavidin, DNA hybridization, IgG, and glucose. The performance of these biosensors has been enhanced by the introduction of various sensing schemes with diverse nanomaterials (e.g., carbon nanotubes, graphene oxide, magnetic and gold nanoparticles, etc.). In addition, the RF biosensing platforms that can be associated with an RF active system are discussed. Finally, the challenges of RF biosensors are presented and suggestions are made for their future direction and prospects.


Assuntos
Técnicas Biossensoriais/instrumentação , Animais , Técnicas Biossensoriais/métodos , Biotina/análise , Desenho de Equipamento , Glucose/análise , Humanos , Imunoglobulina G/análise , Hibridização de Ácido Nucleico/métodos , Ondas de Rádio , Estreptavidina/análise , Transdutores
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA