Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros

Base de dados
Tipo de documento
Ano de publicação
Intervalo de ano de publicação
1.
Eur J Pediatr ; 182(12): 5375-5383, 2023 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-37740771

RESUMO

Lung ultrasound (LU) has emerged as the imaging technique of choice for the assessment of neonates with respiratory distress syndrome (RDS) at the bedside. Scoring systems were developed to quantify RDS severity and to predict the need for surfactant administration. There is no data on the comparison of the three main LU scores (LUS) proposed by Brat, Raimondi and Rodriguez-Fanjul. Moreover, there is not enough evidence to recommend which score and which cut-off has the best ability to predict surfactant need. The three LUS were compared in terms of ability to predict the need for surfactant and reproducibility in a cohort of very preterm infants. This was an observational, retrospective, multicenter study. Neonates below 32 weeks of gestational age with RDS, on non-invasive ventilation with a LU performed prior to surfactant administration (1-3 h of life) were included. Brat, Raimondi, and Rodriguez-Fanjul's scores were calculated for each patient. Receiver-operating characteristic (ROC) curve analysis was used to assess the ability to predict surfactant administration. K-Cohen test, Bland-Altman, and intraclass correlation coefficients were used to assess the intra and interobserver variability. Fifty-four preterm infants were enrolled. Brat, Raimondi, and Rodriguez-Fanjul scores showed a strong ability to predict the need for surfactant: the AUCs were 0.85 (95% CI 0.74-0.96), 0.85 (95% CI 0.75-0.96), and 0.79 (95% CI 0.67-0.92), respectively. No significant differences have been found between the AUCs using the DeLong test. Brat and Raimondi's scores had an optimal cut-off value > 8, while the Rodriguez-Fanjul's score > 10. The k-Cohen values of intraobserver agreement for Brat, Raimondi, and Rodriguez-Fanjul's scores were 0.896 (0.698-1.000), 1.000 (1.000-1.000), and 0.922 (0.767-1.000), respectively. The k-Cohen values of interobserver agreement were 0.896 (0.698-1.000), 0.911 (0.741-1.000), and 0.833 (0.612-1.000), respectively.Conclusions: The three LUS had an excellent ability to predict the need for surfactant and an optimal intra and interobserver agreement. The differences found between the three scores are minimal with negligible clinical implications. Since the optimal cut-off value differed, the same score should be used consistently within the same center. What is Known: • Lung ultrasound is a useful bedside imaging tool that should be used in the assessment of neonates with RDS • Scoring systems or lung ultrasound scores allow to quantify the severity of the pulmonary disease and to predict the need for surfactant replacement therapy What is New: • The three lung ultrasound scores by Brat, Raimondi and Rodriguez-Fanjul have an excellent ability to predict the need for surfactant replacement therapy, although with different cut-off values • All three lung ultrasound scores had an excellent intra and interobserver reproducibility.


Assuntos
Surfactantes Pulmonares , Síndrome do Desconforto Respiratório do Recém-Nascido , Recém-Nascido , Humanos , Recém-Nascido Prematuro , Estudos Retrospectivos , Reprodutibilidade dos Testes , Pulmão/diagnóstico por imagem , Surfactantes Pulmonares/uso terapêutico , Síndrome do Desconforto Respiratório do Recém-Nascido/terapia , Ultrassonografia , Tensoativos/uso terapêutico
2.
Sci Rep ; 14(1): 8881, 2024 04 17.
Artigo em Inglês | MEDLINE | ID: mdl-38632330

RESUMO

Echocardiographic assessment of left ventricular function is crucial in NICU. The study aimed to compare the accuracy and agreement of global longitudinal strain (GLS) with conventional measurements. Real-life echocardiograms of neonates receiving intensive care were retrospectively reviewed. Shortening fraction (SF), ejection fraction (EF) and S' measurements were retrieved from health records. GLS was calculated offline from stored images. The association with stroke volume indexed for body weight (iSV) was evaluated by regression analysis. The diagnostic ability to identify uncompensated shock was assessed by ROC curve analysis. Cohen's κ was run to assess agreement. 334 echocardiograms of 155 neonates were evaluated. Mean ± SD gestational age and birth weight were 34.5 ± 4.1 weeks and 2264 ± 914 g, respectively. SF, EF, S' and GLS were associated with iSV with R2 of 0.133, 0.332, 0.252 and 0.633, (all p < .001). Including all variables in a regression model, iSV prediction showed an adjusted R2 of 0.667, (p < .001). GLS explained 73% of the model variance. GLS showed a better ability to diagnose uncompensated shock (AUC 0.956) compared to EF, S' and SF (AUC 0.757, 0.737 and 0.606, respectively). GLS showed a moderate agreement with EF (κ = .500, p < .001) and a limited agreement with S' and SF (κ = .260, p < .001, κ = .242, p < .001). GLS was a more informative index of left ventricular performance, providing the rationale for a more extensive use of GLS at the cotside.


Assuntos
Deformação Longitudinal Global , Disfunção Ventricular Esquerda , Recém-Nascido , Humanos , Estudos Retrospectivos , Função Ventricular Esquerda , Volume Sistólico , Cuidados Críticos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA