Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 21
Filtrar
1.
Circ J ; 88(7): 1089-1098, 2024 Jun 25.
Artigo em Inglês | MEDLINE | ID: mdl-38355108

RESUMO

BACKGROUND: The aim of this study was to build an auto-segmented artificial intelligence model of the atria and epicardial adipose tissue (EAT) on computed tomography (CT) images, and examine the prognostic significance of auto-quantified left atrium (LA) and EAT volumes for AF.Methods and Results: This retrospective study included 334 patients with AF who were referred for catheter ablation (CA) between 2015 and 2017. Atria and EAT volumes were auto-quantified using a pre-trained 3-dimensional (3D) U-Net model from pre-ablation CT images. After adjusting for factors associated with AF, Cox regression analysis was used to examine predictors of AF recurrence. The mean (±SD) age of patients was 56±11 years; 251 (75%) were men, and 79 (24%) had non-paroxysmal AF. Over 2 years of follow-up, 139 (42%) patients experienced recurrence. Diabetes, non-paroxysmal AF, non-pulmonary vein triggers, mitral line ablation, and larger LA, right atrium, and EAT volume indices were linked to increased hazards of AF recurrence. After multivariate adjustment, non-paroxysmal AF (hazard ratio [HR] 0.6; 95% confidence interval [CI] 0.4-0.8; P=0.003) and larger LA-EAT volume index (HR 1.1; 95% CI 1.0-1.2; P=0.009) remained independent predictors of AF recurrence. CONCLUSIONS: LA-EAT volume measured using the auto-quantified 3D U-Net model is feasible for predicting AF recurrence after CA, regardless of AF type.


Assuntos
Tecido Adiposo , Fibrilação Atrial , Ablação por Cateter , Estudos de Viabilidade , Pericárdio , Recidiva , Humanos , Fibrilação Atrial/cirurgia , Fibrilação Atrial/fisiopatologia , Fibrilação Atrial/diagnóstico por imagem , Masculino , Pessoa de Meia-Idade , Feminino , Ablação por Cateter/métodos , Tecido Adiposo/diagnóstico por imagem , Estudos Retrospectivos , Pericárdio/diagnóstico por imagem , Idoso , Tomografia Computadorizada por Raios X , Átrios do Coração/diagnóstico por imagem , Átrios do Coração/fisiopatologia , Valor Preditivo dos Testes , Tecido Adiposo Epicárdico
2.
J Cardiovasc Electrophysiol ; 34(12): 2504-2513, 2023 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-37822117

RESUMO

INTRODUCTION: Despite undergoing an index ablation, some patients progress from paroxysmal atrial fibrillation (PAF) to persistent AF (PersAF), and the mechanism behind this is unclear. The aim of this study was to investigate the predictors of progression to PersAF after catheter ablation in patients with PAF. METHODS: This study included 400 PAF patients who underwent an index ablation between 2015 and 2019. The patients were classified into three groups based on their outcomes: Group 1 (PAF to sinus rhythm, n = 226), Group 2 (PAF to PAF, n = 146), and Group 3 (PAF to PersAF, n = 28). Baseline and procedural characteristics were collected, and predictors for AF recurrence and progression were evaluated. RESULTS: The mean age of the patients was 58.4 ± 11.1 years, with 272 males. After 3 years of follow-up, 7% of the PAF cases recurred and progressed to PersAF despite undergoing an index catheter ablation. In the multivariable analysis, a larger left atrial (LA) diameter and the presence of non-pulmonary vein (PV) triggers during the index procedure independently predicted recurrence. Moreover, a larger LA diameter, the presence of non-PV triggers, and a history of thyroid disease independently predicted AF progression. CONCLUSION: The progression from PAF to PersAF after catheter ablation is associated with a larger LA diameter, history of thyroid disease, and the presence of non-PV triggers. Meticulous preprocedural evaluation, patient selection, and comprehensive provocation tests during catheter ablation are recommended.


Assuntos
Fibrilação Atrial , Ablação por Cateter , Veias Pulmonares , Doenças da Glândula Tireoide , Masculino , Humanos , Pessoa de Meia-Idade , Idoso , Fibrilação Atrial/diagnóstico , Fibrilação Atrial/cirurgia , Resultado do Tratamento , Veias Pulmonares/cirurgia , Ablação por Cateter/efeitos adversos , Ablação por Cateter/métodos , Recidiva
3.
Europace ; 25(5)2023 05 19.
Artigo em Inglês | MEDLINE | ID: mdl-37097046

RESUMO

AIMS: This study investigated the epidemiological characteristics of new-onset dementia in patients with atrial fibrillation (AF) and the association of catheter ablation with different subtypes of dementia. METHODS AND RESULTS: We conducted a population-based, retrospective cohort study using data from the Taiwan National Health Insurance Research Database. In total, 136 774 patients without a history of dementia were selected after 1:1 propensity score matching based on age (with AF vs. without AF). A competing risk model was used to investigate the three subtypes of dementia: Alzheimer's disease, vascular dementia, and other/mixed dementia. Inverse probability of treatment weighting (IPTW) was performed to minimize the impact on dementia risk due to the imbalanced baseline characteristics. After a median follow-up period of 6.6 years, 8704 events of new-onset dementia occurred. Among all AF patients developing dementia, 73% were classified as having Alzheimer's disease, 16% as having vascular dementia, and 11% as having other/mixed dementia. The cumulative incidence of dementia in AF patients was higher than those without AF (log-rank test: P < 0.001 for both before and after IPTW). In patients with AF undergoing catheter ablation, the total dementia risk decreased significantly [P = 0.015, hazard ratio (HR): 0.74, 95% confidence interval (CI): 0.58-0.94] after multivariable adjustment, but not for the subtype of vascular dementia (P = 0.59, HR: 0.86, 95% CI: 0.49-1.50). CONCLUSION: Patients with AF have a higher incidence of all types of dementia, including Alzheimer's disease, vascular dementia, and a mixed type of dementia. Alzheimer's disease is less likely to occur in patients with AF undergoing catheter ablation.


Assuntos
Doença de Alzheimer , Fibrilação Atrial , Ablação por Cateter , Demência Vascular , Humanos , Fibrilação Atrial/diagnóstico , Fibrilação Atrial/epidemiologia , Fibrilação Atrial/cirurgia , Doença de Alzheimer/diagnóstico , Doença de Alzheimer/epidemiologia , Doença de Alzheimer/complicações , Demência Vascular/complicações , Demência Vascular/cirurgia , Estudos Retrospectivos , Comportamento de Redução do Risco , Ablação por Cateter/efeitos adversos , Fatores de Risco , Resultado do Tratamento , Seguimentos , Recidiva
4.
Circ J ; 87(12): 1750-1756, 2023 11 24.
Artigo em Inglês | MEDLINE | ID: mdl-37866912

RESUMO

BACKGROUND: Circumferential pulmonary vein isolation (CPVI) has supplanted segmental PVI (SPVI) as standard procedure for atrial fibrillation (AF). However, there is limited evidence examining the efficacy of these strategies in redo ablations. In this study, we investigated the difference in recurrence rates between SPVI and CPVI in redo ablations for PV reconnection.Methods and Results: This study retrospectively enrolled 543 patients who had undergone AF ablation between 2015 and 2017. Among them, 167 patients (30.8%, including 128 male patients and 100 patients with paroxysmal AF) underwent redo ablation for recurrent AF. Excluding 26 patients without PV reconnection, 141 patients [90 patients of SPVI (Group 1) and 51 patients of CPVI (Group 2)] were included. The AF-free survival rates were 53.3% and 56.9% in Group 1 and Group 2, respectively (P=0.700). The atrial flutter (AFL)-free survival rates were 90% and 100% in Group 1 and Group 2, respectively (P=0.036). The ablation time was similar between groups, and there no major complications were observed. CONCLUSIONS: For redo AF ablation procedures, SPVI and CPVI showed similar outcomes, except for a higher AFL recurrence rate for SPVI after long-term follow-up (>2 years). This may be due to a higher probability of residual PV gaps causing reentrant AFL.


Assuntos
Fibrilação Atrial , Ablação por Cateter , Veias Pulmonares , Humanos , Masculino , Fibrilação Atrial/cirurgia , Veias Pulmonares/cirurgia , Estudos Retrospectivos , Resultado do Tratamento , Recidiva , Ablação por Cateter/efeitos adversos , Ablação por Cateter/métodos
5.
Heliyon ; 10(7): e28111, 2024 Apr 15.
Artigo em Inglês | MEDLINE | ID: mdl-38596035

RESUMO

This study develops an efficient approach for precise channel frame detection in complex backgrounds, addressing the critical need for accurate drone navigation. Leveraging YOLACT and group regression, our method outperforms conventional techniques that rely solely on color information. We conducted extensive experiments involving channel frames placed at various angles and within intricate backgrounds, training the algorithm to effectively recognize them. The process involves initial edge image detection, noise reduction through binarization and erosion, segmentation of channel frame line segments using the Hough Transform algorithm, and subsequent classification via the K-means algorithm. Ultimately, we obtain the regression line segment through linear regression, enabling precise positioning by identifying intersection points. Experimental validations validate the robustness of our approach across diverse angles and challenging backgrounds, making significant advancements in UAV applications.

6.
J Cardiol ; 83(5): 306-312, 2024 May.
Artigo em Inglês | MEDLINE | ID: mdl-37838339

RESUMO

BACKGROUND: Modifying the autonomic system after catheter ablation may prevent the recurrence of atrial fibrillation (AF). Evaluation of skin sympathetic nerve activity (SKNA) is a noninvasive method for the assessment of sympathetic activity. However, there are few studies on the effects of different energy settings on SKNA. OBJECTIVE: To investigate the changes in SKNA in different energy settings and their relationship to AF ablation outcomes. METHODS: Seventy-two patients with paroxysmal and persistent AF were enrolled. Forty-three patients received AF ablation with the conventional (ConV) energy setting (low power for long duration), and 29 patients using a high-power, short-duration (HPSD) strategy. The SKNA was acquired from the right arm 1 day before and after the radiofrequency ablation. We analyzed the SKNA and ablation outcomes in the different energy settings. RESULTS: Both groups had a similar baseline average SKNA (aSKNA). We found that the median aSKNA increased significantly from 446.82 µV to 805.93 µV (p = 0.003) in the ConV group but not in the HPSD group. In the ConV group, patients without AF recurrence had higher aSKNA values. However, the 1-year AF recurrence rate remained similar between both groups (35 % vs. 28 %, p = 0.52). CONCLUSION: The post-ablation aSKNA levels increased significantly in the ConV group but did not change significantly in the HPSD group, which may reflect different neuromodulatory effects. However, the one-year AF recurrence rates were similar for both groups. These results demonstrate that the HPSD strategy has durable lesion creation but less lesion depth, which may reduce collateral damage.


Assuntos
Fibrilação Atrial , Ablação por Cateter , Veias Pulmonares , Humanos , Sistema Nervoso Simpático , Ablação por Cateter/métodos , Resultado do Tratamento , Veias Pulmonares/cirurgia , Recidiva
7.
Front Cardiovasc Med ; 11: 1305485, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38292242

RESUMO

Introduction: Catheter ablation is an effective and safe strategy for treating atrial fibrillation patients. Nevertheless, studies on the long-term outcomes of catheter ablation in patients with dilated cardiomyopathy are limited. This study aimed to assess the electrophysiological characteristics of atrial fibrillation patients with dilated cardiomyopathy and compare the long-term clinical outcomes between patients undergoing catheter ablation and medical therapy. Method: Patient baseline characteristics and electrophysiological parameters were examined to identify the predictors of atrial fibrillation recurrence following catheter ablation. The clinical outcomes of catheter ablation and medical therapy were compared using the propensity score matched method. Results: A total of 343 patients were enrolled, with 46 in the catheter ablation group and 297 in the medical therapy group. Among the catheter ablation group, 58.7% (n = 27) had persistent atrial fibrillation. The recurrence rate of atrial arrhythmia was 30.4% (n = 14) after an average follow-up duration of 7.7 years following catheter ablation. The only predictive factor for atrial fibrillation recurrence after catheter ablation was the left atrial diameter. When compared to medical therapy, catheter ablation demonstrated significantly better outcomes in terms of overall survival, freedom from heart failure hospitalization, improvement in left ventricular ejection fraction, and a greater reduction in left ventricular diameter and left atrial diameter after propensity score matching. Conclusions: Therefore, catheter ablation proves to be effective in providing long-term control of atrial fibrillation in patients with dilated cardiomyopathy. In addition to standard heart failure care, catheter ablation significantly enhanced both morbidity and mortality outcomes and reversed structural remodeling when compared to heart failure medication alone.

8.
Heart Rhythm ; 2024 Jul 10.
Artigo em Inglês | MEDLINE | ID: mdl-38997056

RESUMO

BACKGROUND: Prior studies have investigated cardiac anatomy and clinical parameters as predictors for pulmonary vein and non-pulmonary vein triggers. OBJECTIVES: To assess the link between the descending aorta to left inferior pulmonary vein (Dao-LIPV) distance and the occurrence of triggers and drivers in atrial fibrillation (AF) ablation procedures. METHODS: Drug-refractory AF patients who underwent first-time index catheter ablation from January 2010 to December 2019 were retrospectively assembled. The Dao-LIPV distance was measured from pre-ablation pulmonary vein computed tomography. Patients were categorized based on the presence of LIPV triggers and/or drivers. Multivariate logistic regression was used to identify risk factors. RESULTS: A total of 886 consecutive patients with drug-refractory AF were studied, and 63 (7.1%) patients were identified to have LIPV triggers and/or drivers. The Dao-LIPV distance had a better predictive performance (AUC: 0.70) compared to persistent AF (AUC: 0.57). Multivariate logistic regression analysis showed that Dao-LIPV distance ≤ 2.5 mm (Odds ratio [OR] 3.96 [95% CI 2.15-7.29], p <0.001) and persistent AF (OR 1.73 [95% CI 1.02-2.94], p=0.044) were independent predictors for the presence of LIPV triggers and/or drivers. A risk score model was established to predict the probability of LIPV triggers or drivers with persistent AF (10.2%), Dao-LIPV distance ≤ 2.5mm (11.4%), and both (15.0%). CONCLUSIONS: The close proximity of the Dao-LIPV was correlated to the presence of LIPV triggers or drivers. We developed a risk score model indicating that persistent AF and Dao-LIPV distances ≤ 2.5mm significantly increase the risk of LIPV triggers/drivers, aiding electrophysiologists in preparing for and performing catheter ablation more effectively.

9.
Front Cardiovasc Med ; 11: 1306055, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38689859

RESUMO

Introduction: Signal-averaged electrocardiography (SAECG) provides diagnostic and prognostic information regarding cardiac diseases. However, its value in other nonischemic cardiomyopathies (NICMs) remains unclear. This study aimed to investigate the role of SAECG in patients with NICM. Methods and results: This retrospective study included consecutive patients with NICM who underwent SAECG, biventricular substrate mapping, and ablation for ventricular arrhythmia (VA). Patients with baseline ventricular conduction disturbances were excluded. Patients who fulfilled at least one SAECG criterion were categorized into Group 1, and the other patients were categorized into Group 2. Baseline and ventricular substrate characteristics were compared between the two groups. The study included 58 patients (39 men, mean age 50.4 ± 15.5 years), with 34 and 24 patients in Groups 1 and 2, respectively. Epicardial mapping was performed in eight (23.5%) and six patients (25.0%) in Groups 1 and 2 (p = 0.897), respectively. Patients in Group 1 had a more extensive right ventricular (RV) low-voltage zone (LVZ) and scar area than those in Group 2. Group 1 had a larger epicardial LVZ than Group 2. Epicardial late potentials were more frequent in Group 1 than in Group 2. There were more arrhythmogenic foci within the RV outflow tract in Group 1 than in Group 2. There was no significant difference in long-term VA recurrence. Conclusion: In our NICM population, a positive SAECG was associated with a larger RV endocardial scar, epicardial scar/late potentials, and a higher incidence of arrhythmogenic foci in the RV outflow tract.

10.
Front Cardiovasc Med ; 10: 1135230, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-37252115

RESUMO

Background: Catheter ablation (CA) is a treatment strategy for atrial fibrillation (AF) in patients with hypertrophic cardiomyopathy (HCM). We investigated the electrophysiological characteristics of recurrence in a tertiary referral center and compared long-term clinical outcomes after CA therapy with patients who did not undergo CA. Methods: Patients with HCM and AF who underwent CA (group 1, n = 60) or pharmacological treatment (group 2, n = 298) between 2006 and 2021 were enrolled in this study. The baseline characteristics and electrophysiological characteristics of group 1 patients were examined to elucidate the reason for the recurrence of AF after CA therapy. The clinical results of the patients in Group 1 and Group 2 were compared using a propensity score (PS)-matched method. Results: The most common cause of recurrence was pulmonary vein reconnection (86.5%), followed by non-pulmonary vein triggers (40.5%), cavotricuspid isthmus flutter (29.7%), and atypical flutter (24.3%). Thyroid disease (HR, 14.713; P < 0.01), diabetes (HR, 3.074; P = 0.03), and non-paroxysmal AF (HR, 4.012; P = 0.01); these factors independently predicted recurrence. After the first recurrence, patients who underwent repeat CA showed a better arrhythmia-free state (74.1%) than those who underwent drug escalation therapy (29.4%, P < 0.01). After matching, PS-group 1 patients showed significantly better outcomes in all-cause mortality, heart failure hospitalization, and left atrial reverse remodeling than PS-group 2 patients. Conclusions: Patients who underwent CA showed better clinical outcomes than those who underwent drug therapy. The main predictors of recurrence were thyroid disease, diabetes, and non-paroxysmal AF.

11.
Front Cardiovasc Med ; 10: 1265890, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-37953760

RESUMO

Background: Atrial fibrillation (AF) and mitral regurgitation (MR) have a complex interplay. Catheter ablation (CA) of AF may be a potential method to improve the severity of MR in AF patients. Methods: Patients with symptomatic AF and moderate to severe MR who underwent catheter ablation from 2011 to 2021 were retrospectively included in the study. Patients' baseline characteristics and electrophysiological features were examined. These patients were classified as group 1 with improved MR and group 2 with refractory MR after CA. Results: Fifty patients (age 60.2 ± 11.6 years, 29 males) were included in the study (32 in group 1 and 18 in group 2). Group 1 patients had a lower CHA2DS2-VASc score (1.7 ± 1.5 vs. 2.7 ± 1.5, P = 0.005) and had a lower incidence of hypertension (28.1% vs. 66.7%, P = 0.007) and diabetes mellitus (3.1% vs. 22.2%, P = 0.031) as compared to group 2 patients. Electroanatomic three-dimensional (3D) mapping showed that group 1 patients demonstrated less scars on the posterior bottom of the left atrium compared to group 2 patients (12.5% vs. 66.7%, P < 0.001). AF recurrence was not different between the two groups. After multivariate logistic regression analysis, a posterior bottom scar in the left atrium independently predicted refractory MR despite successful AF ablation. Conclusion: Most patients with AF and MR showed improvement of MR after AF ablation. A scar involving the posterior bottom of the left atrium is associated with poor recovery of MR.

12.
Vaccines (Basel) ; 10(8)2022 Aug 10.
Artigo em Inglês | MEDLINE | ID: mdl-36016174

RESUMO

The association of SARS-CoV-2 messenger ribonucleic acid vaccines with pericarditis in young adults has been reported. However, data regarding other types of vaccines are extremely limited. We presented a 94-year-old man with rapidly progressive dyspnea and fatigue six days after his first ChAdOx1 nCoV-19 vaccination. Impending cardiac tamponade and bilateral pleural effusion were found. Hence, massive yellowish pericardial and pleural effusion were drained. However, the pleural effusion persisted and pigtail catheters were inserted bilaterally. After serial studies including surgical pleural biopsy, acute polyserositis (pericarditis and pleurisy) was diagnosed. Anti-inflammatory treatment with colchicine and prednisolone was administered. All effusions resolved accordingly. This rare case sheds light on the presentation of ChAdOx1 nCoV-19 vaccine-related acute polyserositis. In conclusion, awareness of this potential adverse event may facilitate the diagnosis for unexplained pericardial or pleural effusion after vaccination.

13.
J Clin Med ; 11(11)2022 Jun 04.
Artigo em Inglês | MEDLINE | ID: mdl-35683600

RESUMO

Identification of sinus node dysfunction (SND) before termination of persistent AFL by catheter ablation (CA) is challenging. This study aimed to investigate the characteristics and predictors of acute and delayed SND after AFL ablation. We retrospectively enrolled 221 patients undergoing CA of persistent AFL in a tertiary referral center. Patients with SND who required a temporary pacemaker (TPM) after termination of AFL or a permanent pacemaker (PPM) during follow-up were identified. Acute SND requiring a TPM was found in 14 of 221 (6.3%) patients following successful termination of AFL. A total of 10 of the 14 patients (71.4%) recovered from acute SND. An additional 11 (5%) patients presenting with delayed SND required a PPM during follow-up, including 4 patients recovering from acute SND. Of these, 9 of these 11 patients (81.8%) underwent PPM implantation within 1 year after the ablation. In multivariable analysis, female gender and a history of hypothyroidism were associated with the requirement for a TPM following termination of persistent AFL, while older age and a history of hypothyroidism predicted PPM implantation. This study concluded that the majority of patients with acute SND still require a PPM implantation despite the initial improvement. Therefore, it is reasonable to monitor the patients closely for at least one year after AFL ablation.

14.
Front Cardiovasc Med ; 8: 676897, 2021.
Artigo em Inglês | MEDLINE | ID: mdl-34336945

RESUMO

Background: The clinical significance and outcomes of ventricular tachyarrhythmias (VTa) in patients undergoing valve replacement have rarely been reported. Objective: This study aimed to investigate the incidence and outcome of VTa after surgical valve replacement. Methods: We conducted a population-based retrospective cohort study using data obtained from the Taiwan National Health Insurance Research Database. In total, 10,212 patients were selected after 1:1 propensity-score matching based on the type of prosthetic valve used (mechanical vs. bioprosthetic). Various outcomes during long-term follow-up were analyzed. Results: After a median follow-up period of 59.6 months, the crude incidence rate of VTa after surgical valve replacement was 4.8/1,000 person-years, and the cumulative incidence of VTa persistently increased after surgery. Furthermore, the occurrences of VTa after valve replacement significantly increased the risk of cardiovascular (CV) death (P < 0.001, HR 1.67, 95% CI 1.41-1.96), stroke- (P < 0.001, HR 1.66, 95% CI 1.37-2.01), atrial fibrillation- (P < 0.001, HR 2.80, 95% CI 2.42-3.24), and congestive heart failure-related hospitalization (P < 0.001, HR 2.61, 95% CI 2.30-2.95). Among patients with VTa, all-cause mortality (P = 0.001, HR 0.49, 95% CI 0.32-0.75) and CV death (P = 0.047, HR 0.58, 95% CI 0.34-0.99) in those with implantable cardioverter-defibrillator (ICD) implantation were lower than those without. Conclusion: The crude incidence rate of VTa after surgical valve replacement was 4.8/1,000 person-years, and the cumulative incidence of VTa persistently increased during follow-up. The presence of VTa after surgical valve replacement increases hospitalization and CV death, while ICD implantation reduced the mortality rate in these patients.

15.
Front Cardiovasc Med ; 8: 745370, 2021.
Artigo em Inglês | MEDLINE | ID: mdl-34977171

RESUMO

Background: Valve replacement is associated with worse outcomes in individuals who have end-stage renal disease (ESRD) and require a long-term renal replacement therapy. Prosthetic valve selection in patients with ESRD has remained controversial. Objective: We aimed to investigate long-term outcomes of mechanical and bioprosthetic valve replacement in individuals with ESRD. Methods: We conducted a population-based retrospective cohort study using data obtained from the Taiwan National Health Insurance Research Database. In total, 10,202 patients, including 912 ESRD and 9,290 non-ESRD patients, were selected after a 1:1 propensity-score matching based on the type of prosthetic valve used. The long-term mortality outcomes were then analyzed. Results: During a median follow-up period of 59.6 months, the Kaplan-Meier survival analysis revealed that ESRD patients who underwent mechanical valve replacement had higher rates of all-cause mortality and CV deaths than those who underwent bioprosthetic valve replacement (Log-rank test, p = 0.03 and 0.02, respectively). Multivariable regression analyses demonstrated that ESRD patients who underwent bioprosthetic valve replacement had lower rates of all-cause mortality (p < 0.001, hazard ratio: 0.88, 95% confidence interval: 0.82-0.93) and cardiovascular (CV) death (p < 0.001, hazard ratio: 0.83, 95% confidence interval: 0.76-0.90) than those who had mechanical valve replacement. Conclusion: Bioprosthetic valve replacement is significantly associated with lower rates of all-cause mortality and CV death in the ESRD population.

16.
J Sep Sci ; 31(10): 1819-27, 2008 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-18481324

RESUMO

A novel single-step sol-gel approach for the preparation of beta-CD-bonded silica monolithic electrochromatographic columns is established. The porous silica networks were fabricated inside fused-silica capillaries using sol-gel processing of tetramethoxysilane and an organfunctional silicon alkoxide that contains beta-CD. Scanning electron micrographs and nitrogen adsorption-desorption data showed that these functional monolithic columns have double pores structures with micrometer-size co-continuous through-pores and silica skeletons with open mesopores. The beta-CD monolithic columns have successfully been applied to the separation of several neutral and negatively charged isomers by CEC. The column performance was evaluated by using positional isomers of naphthalenedisulfonic acid as model compounds. A plate height of less than 10 mum for the first eluted isomer of naphthalenedisulfonic acid was obtained at an optimal flow rate (0.47 mm/s) of the mobile phase. Moreover, the columns have been proved to be stable for more than 100 runs during 3 months period and show reasonable column reproducibility.

18.
Korean Circ J ; 50(10): 955-956, 2020 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-32725992
19.
Anal Chim Acta ; 576(1): 117-23, 2006 Aug 18.
Artigo em Inglês | MEDLINE | ID: mdl-17723622

RESUMO

A single-step approach has been used to prepare a monolithic electrochromatographic column by sol-gel processing of an organofunctional silicon alkoxide precursor that contains a propyl-N,N,N-trimethylammonium group. We have found that the time of adding the porogen, poly(ethylene glycol), during the sol-gel reaction affected the separation performance. Since the surface charge of this material is switchable in sign upon manipulation of solution pH, the direction and magnitude of the electroosmotic flow (EOF) can be controlled by adjusting the pH of the running electrolyte. By controlling the direction of the EOF from cathode to anode, inorganic anions can be separated in a short time. Because of the quaternary ammonium functional group, the resulting material is anion exchangeable. Interestingly, the anion-exchange selectivity of inorganic anions on this column changes with solution pH or applied voltage. The column shows excellent run to run reproducibility (R.S.D.<0.4%), good day to day reproducibility (R.S.D.<4%), and reasonable column to column reproducibility (R.S.D.<9%).

20.
Shi Yan Sheng Wu Xue Bao ; 36(3): 209-14, 2003 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-12966731

RESUMO

Two cDNA fragments, named for SRGKC2 and SRGKC3, encoding cyclophilin in Kandelia candel were isolated by Representational Difference Analysis of cDNA. The two cDNA fragments were 282 bp and 160 bp, respectively. Sequence analysis shows that both of the SRGKC2 and SRGKC3 come from the same gene region, and SRGKC3 is a part of SRGKC2. In addition the SRGKC2 displayed 90% sequence identity over a region of 84 amino acids to the cyclophilin from Euphorbia esula and the SRGKC3 displayed 93% sequence identity over a region of 47 amino acids to the fava bean. The Northern blotting showed that the expression of SRGKC2 was suppressed under stress of salt. Based on the sequence of SRGKC2, a full-length cDNA (KCCYP1) was isolated by RACE reaction (This sequence data has been submitted to the EMBL databases under accession No. AY150052). The full-length cDNA was about 0.9 kb, which contained an open reading frame (ORF) of 516 bp and coded for 172 amino acid residues with isoelectric point of 8.57 and molecular weight of 18.2 kD. The motif A of the ATP/GTP-binding site in KCCYP1 appears at amino acid residues of 41-49, and seven-amino-acids-residue was inserted at 48-54 amino acid residues. The expression patterns of SRGKC2 in various species were also investigated.


Assuntos
Ciclofilinas/genética , Regulação da Expressão Gênica de Plantas , Rhizophoraceae/genética , Cloreto de Sódio/farmacologia , Sequência de Aminoácidos , Sequência de Bases , Ciclofilinas/biossíntese , DNA Complementar/química , DNA Complementar/genética , DNA de Plantas/genética , Euphorbia/genética , Dados de Sequência Molecular , Fases de Leitura Aberta/genética , Pressão Osmótica , Rhizophoraceae/crescimento & desenvolvimento
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA