Bioanalysis ; 15(15): 905-914, 2023 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-37354101

RESUMO

Background: Workplace drug testing primarily relies on urine analysis, targeting multiple compounds with varying physicochemical characteristics. Biocompatible solid-phase microextraction (BioSPME) is a miniaturized solid-phase extraction technique that enables the simultaneous extraction and preconcentration of analytes directly from the biological matrix. Methods: The BioSPME procedure consisted of the sequential extraction of 50-µl urine samples using LC Tips C18 in basic and acidic pH, followed by desorption with methanol and n-hexane, respectively. The extracts were analyzed by ultra-performance LC-MS/MS. Results: Intra-day precision was 1.2-8.6% and inter-day precision was 1.8-14.2%. Accuracy was 96.8-107.4%. The extraction yields were 62.8-109.4%. The matrix effects were -3.98% to 1%. Conclusion: BioSPME shows promise as an alternative method for preparing urine samples prior to drug measurement by ultra-performance LC-MS/MS.


Assuntos
Cocaína , Dronabinol , Cromatografia Líquida/métodos , Cocaína/análise , Analgésicos Opioides , Espectrometria de Massas em Tandem/métodos , Extração em Fase Sólida , Anfetaminas/análise , Cromatografia Líquida de Alta Pressão/métodos
2.
Bioanalysis ; 14(20): 1295-1303, 2022 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-36468628

RESUMO

Background: Dried blood spot sampling has been reported for on-site collection of specimens, but measurements are affected by blood hematocrit, and special handling is required, especially for forensic applications. The hemaPEN® blood collection device was developed to produce spots with constant volume. Results: Linearity between 1 and 500 ng/ml was shown for cocaine and the metabolites benzoylecgonine and cocaethylene. The assay demonstrated acceptable precision and accuracy, and analytes were stable for 7 days when kept inside hemaPEN devices. Accuracy of the assay was affected by hematocrit but was within acceptable limits. Conclusion: Use of the hemaPEN, which retains dried blood within the device, could be advantageous for the quantification of illicit drugs in capillary blood compared with conventional dried blood spot collection.


Assuntos
Cocaína , Espectrometria de Massas em Tandem , Cromatografia Líquida , Teste em Amostras de Sangue Seco , Manejo de Espécimes