1.
Audiol Neurootol ; 16(6): 359-80, 2011.
Artigo em Inglês | MEDLINE | ID: mdl-21196727

RESUMO

The aim of this study was to document receptive and expressive language levels and reading skills achieved by Mandarin-speaking children who had received cochlear implants (CIs) and used them for 4.75-7.42 years. The effects of possible associated factors were also analyzed. Standardized Mandarin language and reading tests were administered to 39 prelingually deaf children with Nucleus 24 devices. The Mandarin Chinese version of the Peabody Picture Vocabulary Test was used to assess their receptive vocabulary knowledge and the Revised Primary School Language Assessment Test for their receptive and expressive language skills. The Graded Chinese Character Recognition Test was used to test their written word recognition ability and the Reading Comprehension Test for their reading comprehension ability. Raw scores from both language and reading measurements were compared to normative data of nor- mal-hearing children to obtain standard scores. The results showed that the mean standard score for receptive vocabulary measurement and the mean T scores for the receptive language, expressive language and total language measurement were all in the low-average range in comparison to the normative sample. In contrast, the mean T scores for word and text reading comprehension were almost the same as for their age-matched hearing counterparts. Among all children with CIs, 75.7% scored within or above the normal range of their age-matched hearing peers on receptive vocabulary measurement. For total language, Chinese word recognition and reading scores, 71.8, 77 and 82% of children with CIs were age appropriate, respectively. A strong correlation was found between language and reading skills. Age at implantation and sentence perception scores account for 37% of variance for total language outcome. Sentence perception scores and preimplantation residual hearing were revealed to be associated with the outcome of reading comprehension. We concluded that by using standard tests, the language development and reading skill of Mandarin-speaking children who use CIs from a young age appear to fall within the normal range of their hearing age mates, at least after 4.8-7.4 years of experience. However, to fully evaluate the fine linguistic skills of these subjects, a more detailed study and longer follow-up period are needed.


Assuntos
Perda Auditiva Bilateral/cirurgia , Perda Auditiva Neurossensorial/cirurgia , Desenvolvimento da Linguagem , Idioma , Leitura , Criança , Implante Coclear , Implantes Cocleares , Feminino , Perda Auditiva Bilateral/fisiopatologia , Perda Auditiva Neurossensorial/fisiopatologia , Humanos , Masculino , Pessoas com Deficiência Auditiva , Percepção da Fala/fisiologia , Taiwan , Resultado do Tratamento
2.
Int J Pediatr Otorhinolaryngol ; 77(9): 1474-80, 2013 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-23838541

RESUMO

OBJECTIVES: To document academic achievements and classroom performance in 35 Mandarin-speaking, congenital/pre-lingual, deafened children who used cochlear implants (CIs) for 5-11 years. The possible associated factors were also analyzed. STUDY DESIGN: Cross-sectional case series. METHODS: Standardized Chinese literacy ability and mathematics tests were administered to evaluate the academic achievement of these children. Raw scores derived from both literacy ability and mathematics tests were compared with normative data from children with normal hearing (NH). A modified Mandarin edition of the Screening Instrument for Targeting Educational Risk (SIFTER) and a Regular School Adjustment Scale (RSAS) for students with hearing impairments filled out by regular classroom teachers were used to assess the children's classroom performances. RESULTS: The mean standard T-scores for Chinese literacy ability and mathematics ability were 48.6 and 50.3 (NORM=50 ± 10), respectively. A total of 85.7% of children with CIs scored within or above the normal range of their age-matched hearing peers in Chinese literacy ability, and 82.9% were within normal ranges in mathematics ability. The SIFTER results showed that 45.7% failure was noted on the communication subscale, and the RSAS also indicated 40% of CI students to have communication problems. The academic subscale scores on the SIFTER were associated with the children's Chinese literacy abilities. The Verbal Comprehension Index (VCI) of the Wechsler IQ test IV was related to the children's mathematics abilities. CONCLUSIONS: The academic achievements of Mandarin-speaking children who receive CIs from a young age and are integrated into mainstream elementary school system appear to fall within the normal range of their age-matched hearing counterparts after 5-11 years of use. This study strongly suggests the need for future ongoing support for these children in communication field.


Assuntos
Implante Coclear/métodos , Implantes Cocleares , Surdez/cirurgia , Avaliação Educacional , Fonética , Percepção da Fala/fisiologia , Povo Asiático , Criança , Pré-Escolar , Estudos de Coortes , Surdez/congênito , Feminino , Humanos , Idioma , Desenvolvimento da Linguagem , Modelos Lineares , Inclusão Escolar/métodos , Masculino , Análise Multivariada , Estudos Retrospectivos , Medida da Produção da Fala , Estudantes , Taiwan
SELEÇÃO DE REFERÊNCIAS