Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 76
Filtrar
1.
Br J Surg ; 111(4)2024 Apr 03.
Artigo em Inglês | MEDLINE | ID: mdl-38597154

RESUMO

BACKGROUND: Trials have demonstrated the safety of omitting completion axillary lymph node dissection in patients with cT1-2 N0 breast cancer operated with breast-conserving surgery who have limited metastatic burden in the sentinel lymph node. The aim of this registry study was to provide insight into the oncological safety of omitting completion axillary treatment in patients operated with mastectomy who have limited-volume sentinel lymph node metastasis. METHODS: Women diagnosed in 2013-2014 with unilateral cT1-2 N0 breast cancer treated with mastectomy, with one to three sentinel lymph node metastases (pN1mi-pN1a), were identified from the Netherlands Cancer Registry, and classified by axillary treatment: no completion axillary treatment, completion axillary lymph node dissection, regional radiotherapy, or completion axillary lymph node dissection followed by regional radiotherapy. The primary endpoint was 5-year regional recurrence rate. Secondary endpoints included recurrence-free interval and overall survival, among others. RESULTS: In total, 1090 patients were included (no completion axillary treatment, 219 (20.1%); completion axillary lymph node dissection, 437 (40.1%); regional radiotherapy, 327 (30.0%); completion axillary lymph node dissection and regional radiotherapy, 107 (9.8%)). Patients in the group without completion axillary treatment had more favourable tumour characteristics and were older. The overall 5-year regional recurrence rate was 1.3%, and did not differ significantly between the groups. The recurrence-free interval was also comparable among groups. The group of patients who did not undergo completion axillary treatment had statistically significantly worse 5-year overall survival, owing to a higher percentage of non-cancer deaths. CONCLUSION: In this registry study of patients with cT1-2 N0 breast cancer treated with mastectomy, with low-volume sentinel lymph node metastasis, the 5-year regional recurrence rate was low and comparable between patients with and without completion axillary treatment.


Assuntos
Neoplasias da Mama , Linfonodo Sentinela , Humanos , Feminino , Biópsia de Linfonodo Sentinela , Neoplasias da Mama/patologia , Mastectomia , Metástase Linfática/patologia , Excisão de Linfonodo , Linfonodo Sentinela/patologia , Mastectomia Segmentar , Axila/patologia , Sistema de Registros , Linfonodos/cirurgia , Linfonodos/patologia
2.
Eur Radiol ; 2024 Jan 16.
Artigo em Inglês | MEDLINE | ID: mdl-38227202

RESUMO

OBJECTIVES: To perform a survey among members of the European Society of Breast Imaging (EUSOBI) regarding the use of contrast-enhanced mammography (CEM). METHODS: A panel of nine board-certified radiologists developed a 29-item online questionnaire, distributed to all EUSOBI members (inside and outside Europe) from January 25 to March 10, 2023. CEM implementation, examination protocols, reporting strategies, and current and future CEM indications were investigated. Replies were exploratively analyzed with descriptive and non-parametric statistics. RESULTS: Among 434 respondents (74.9% from Europe), 50% (217/434) declared to use CEM, 155/217 (71.4%) seeing less than 200 CEMs per year. CEM use was associated with academic settings and high breast imaging workload (p < 0.001). The lack of CEM adoption was most commonly due to the perceived absence of a clinical need (65.0%) and the lack of resources to acquire CEM-capable systems (37.3%). CEM protocols varied widely, but most respondents (61.3%) had already adopted the 2022 ACR CEM BI-RADS® lexicon. CEM use in patients with contraindications to MRI was the most common current indication (80.6%), followed by preoperative staging (68.7%). Patients with MRI contraindications also represented the most commonly foreseen CEM indication (88.0%), followed by the work-up of inconclusive findings at non-contrast examinations (61.5%) and supplemental imaging in dense breasts (53.0%). Respondents declaring CEM use and higher CEM experience gave significantly more current (p = 0.004) and future indications (p < 0.001). CONCLUSIONS: Despite a trend towards academic high-workload settings and its prevalent use in patients with MRI contraindications, CEM use and progressive experience were associated with increased confidence in the technique. CLINICAL RELEVANCE STATEMENT: In this first survey on contrast-enhanced mammography (CEM) use and perspectives among the European Society of Breast Imaging (EUSOBI) members, the perceived absence of a clinical need chiefly drove the 50% CEM adoption rate. CEM adoption and progressive experience were associated with more extended current and future indications. KEY POINTS: • Among the 434 members of the European Society of Breast Imaging who completed this survey, 50% declared to use contrast-enhanced mammography in clinical practice. • Due to the perceived absence of a clinical need, contrast-enhanced mammography (CEM) is still prevalently used as a replacement for MRI in patients with MRI contraindications. • The number of current and future CEM indications marked by respondents was associated with their degree of CEM experience.

3.
Eur Radiol ; 2024 Apr 19.
Artigo em Inglês | MEDLINE | ID: mdl-38639912

RESUMO

OBJECTIVES: Supplemental MRI screening improves early breast cancer detection and reduces interval cancers in women with extremely dense breasts in a cost-effective way. Recently, the European Society of Breast Imaging recommended offering MRI screening to women with extremely dense breasts, but the debate on whether to implement it in breast cancer screening programs is ongoing. Insight into the participant experience and willingness to re-attend is important for this discussion. METHODS: We calculated the re-attendance rates of the second and third MRI screening rounds of the DENSE trial. Moreover, we calculated age-adjusted odds ratios (ORs) to study the association between characteristics and re-attendance. Women who discontinued MRI screening were asked to provide one or more reasons for this. RESULTS: The re-attendance rates were 81.3% (3458/4252) and 85.2% (2693/3160) in the second and third MRI screening round, respectively. A high age (> 65 years), a very low BMI, lower education, not being employed, smoking, and no alcohol consumption were correlated with lower re-attendance rates. Moderate or high levels of pain, discomfort, or anxiety experienced during the previous MRI screening round were correlated with lower re-attendance rates. Finally, a plurality of women mentioned an examination-related inconvenience as a reason to discontinue screening (39.1% and 34.8% in the second and third screening round, respectively). CONCLUSIONS: The willingness of women with dense breasts to re-attend an ongoing MRI screening study is high. However, emphasis should be placed on improving the MRI experience to increase the re-attendance rate if widespread supplemental MRI screening is implemented. CLINICAL RELEVANCE STATEMENT: For many women, MRI is an acceptable screening method, as re-attendance rates were high - even for screening in a clinical trial setting. To further enhance the (re-)attendance rate, one possible approach could be improving the overall MRI experience. KEY POINTS: • The willingness to re-attend in an ongoing MRI screening study is high. • Pain, discomfort, and anxiety in the previous MRI screening round were related to lower re-attendance rates. • Emphasis should be placed on improving MRI experience to increase the re-attendance rate in supplemental MRI screening.

4.
Breast Cancer Res Treat ; 201(2): 247-256, 2023 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-37355527

RESUMO

PURPOSE: The aim of the study was to benchmark and compare breast cancer care quality indicators (QIs) between Norway and the Netherlands using federated analytics preventing transfer of patient-level data. METHODS: Breast cancer patients (2017-2018) were retrieved from the Netherlands Cancer Registry and the Cancer Registry of Norway. Five European Society of Breast Cancer Specialists (EUSOMA) QIs were assessed: two on magnetic resonance imaging (MRI), two on surgical approaches, and one on postoperative radiotherapy. The QI outcomes were calculated using 'Vantage 6' federated Propensity Score Stratification (PSS). Likelihood of receiving a treatment was expressed in odds ratios (OR). RESULTS: In total, 39,163 patients were included (32,786 from the Netherlands and 6377 from Norway). PSS scores were comparable to the crude outcomes of the QIs. The Netherlands scored higher on the QI 'proportions of patients preoperatively examined with breast MRI' [37% vs.17.5%; OR 2.8 (95% CI 2.7-2.9)], the 'proportions of patients receiving primary systemic therapy examined with breast MRI' [83.3% vs. 70.8%; OR 2.3 (95% CI 1.3-3.3)], and 'proportion of patients receiving a single breast operation' [95.2% vs. 91.5%; OR 1.8 (95% CI 1.4-2.2)]. Country scores for 'immediate breast reconstruction' and 'postoperative radiotherapy after breast-conserving surgery' were comparable. The EUSOMA standard was achieved in both countries for 4/5 indicators. CONCLUSION: Both countries achieved high scores on the QIs. Differences were observed in the use of MRI and proportion of patients receiving single surgery. The federated approach supports future possibilities on benchmark QIs without transfer of privacy-sensitive data.


Assuntos
Neoplasias da Mama , Humanos , Feminino , Neoplasias da Mama/diagnóstico , Neoplasias da Mama/epidemiologia , Neoplasias da Mama/terapia , Países Baixos/epidemiologia , Indicadores de Qualidade em Assistência à Saúde , Pontuação de Propensão , Noruega/epidemiologia
5.
Breast Cancer Res Treat ; 202(2): 245-255, 2023 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-37495799

RESUMO

PURPOSE: The outcome of the sentinel lymph node in breast cancer patients affects adjuvant treatment. Compared to conventional histopathology, analysis by one-step nucleic acid amplification (OSNA) harvests more micrometastasis, potentially inducing overtreatment. In this study we investigated the impact of OSNA analysis on adjuvant treatment, compared to histopathological analysis. METHODS: Data from T1-3 breast cancer patients with sentinel nodes analysed between January 2016 and December 2019 by OSNA (OSNA group, n = 1086) from Zuyderland Medical Centre, the Netherlands, were compared to concurrent data from the Netherlands Cancer Registry (NKR) where sentinel nodes were examined by histology (histology group, n = 35,143). Primary outcomes were micro- or macrometastasis, axillary treatments (axillary lymph node dissection (ALND) or axillary radiotherapy (ART)), chemotherapy, and endocrine therapy. Statistics with Pearson Chi-square. RESULTS: In the OSNA group more micrometastasis (14.9%) were detected compared to the histology group (7.9%, p < 0.001). No difference in axillary treatment between groups was detected (14.3 vs. 14.4%). In case of mastectomy and macrometastasis, ALND was preferred over ART in the OSNA group (14.9%) compared to the histology group (4.4%, p < 0.001). In cases of micrometastasis, no difference was seen. There was no difference in administration of adjuvant chemotherapy between groups. Endocrine treatment was administrated less often in the OSNA group compared to the histology group (45.8% vs. 50.8%, p < 0.002). CONCLUSION: More micrometastasis were detected by OSNA compared to histopathology, but no subsequent increase in adjuvant axillary and systematic treatment was noticed. When performing mastectomy and OSNA, there was a preference for ALND compared to ART.


Assuntos
Neoplasias da Mama , Ácidos Nucleicos , Linfonodo Sentinela , Humanos , Feminino , Neoplasias da Mama/genética , Neoplasias da Mama/terapia , Neoplasias da Mama/patologia , Linfonodo Sentinela/patologia , Linfonodos/patologia , Biópsia de Linfonodo Sentinela , Micrometástase de Neoplasia/patologia , Mastectomia , Técnicas de Amplificação de Ácido Nucleico , Axila/patologia , Adjuvantes Imunológicos
6.
Breast Cancer Res Treat ; 197(1): 161-175, 2023 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-36334188

RESUMO

PURPOSE: We aimed to compare (1) treatments and time intervals between treatments of breast cancer patients diagnosed during and before the COVID-19 pandemic, and (2) the number of treatments started during and before the pandemic. METHODS: Women were selected from the Netherlands Cancer Registry. For aim one, odds ratios (OR) and 95% confidence intervals (95%CI) were calculated to compare the treatment of women diagnosed within four periods of 2020: pre-COVID (weeks 1-8), transition (weeks 9-12), lockdown (weeks 13-17), and care restart (weeks 18-26), with data from 2018/2019 as reference. Wilcoxon rank-sums test was used to compare treatment intervals, using a two-sided p-value < 0.05. For aim two, number of treatments started per week in 2020 was compared with 2018/2019. RESULTS: We selected 34,097 women for aim one. Compared to 2018/2019, neo-adjuvant chemotherapy was less likely for stage I (OR 0.24, 95%CI 0.11-0.53), stage II (OR 0.63, 95%CI 0.47-0.86), and hormone receptor+/HER2- tumors (OR 0.55, 95%CI 0.41-0.75) diagnosed during transition. Time between diagnosis and first treatment decreased for patients diagnosed during lockdown with a stage I (p < 0.01), II (p < 0.01) or III tumor (p = 0.01). We selected 30,002 women for aim two. The number of neo-adjuvant endocrine therapies and surgeries starting in week 14, 2020, increased by 339% and 18%, respectively. The number of adjuvant chemotherapies decreased by 42% in week 15 and increased by 44% in week 22. CONCLUSION: The pandemic and subsequently altered treatment recommendations affected multiple aspects of the breast cancer treatment strategy and the number of treatments started per week.


Assuntos
Neoplasias da Mama , COVID-19 , Humanos , Feminino , Neoplasias da Mama/terapia , Neoplasias da Mama/tratamento farmacológico , Pandemias , COVID-19/epidemiologia , Controle de Doenças Transmissíveis , Sistema de Registros
7.
Radiology ; 307(5): e221843, 2023 06.
Artigo em Inglês | MEDLINE | ID: mdl-37338353

RESUMO

Background Handcrafted radiomics and deep learning (DL) models individually achieve good performance in lesion classification (benign vs malignant) on contrast-enhanced mammography (CEM) images. Purpose To develop a comprehensive machine learning tool able to fully automatically identify, segment, and classify breast lesions on the basis of CEM images in recall patients. Materials and Methods CEM images and clinical data were retrospectively collected between 2013 and 2018 for 1601 recall patients at Maastricht UMC+ and 283 patients at Gustave Roussy Institute for external validation. Lesions with a known status (malignant or benign) were delineated by a research assistant overseen by an expert breast radiologist. Preprocessed low-energy and recombined images were used to train a DL model for automatic lesion identification, segmentation, and classification. A handcrafted radiomics model was also trained to classify both human- and DL-segmented lesions. Sensitivity for identification and the area under the receiver operating characteristic curve (AUC) for classification were compared between individual and combined models at the image and patient levels. Results After the exclusion of patients without suspicious lesions, the total number of patients included in the training, test, and validation data sets were 850 (mean age, 63 years ± 8 [SD]), 212 (62 years ± 8), and 279 (55 years ± 12), respectively. In the external data set, lesion identification sensitivity was 90% and 99% at the image and patient level, respectively, and the mean Dice coefficient was 0.71 and 0.80 at the image and patient level, respectively. Using manual segmentations, the combined DL and handcrafted radiomics classification model achieved the highest AUC (0.88 [95% CI: 0.86, 0.91]) (P < .05 except compared with DL, handcrafted radiomics, and clinical features model, where P = .90). Using DL-generated segmentations, the combined DL and handcrafted radiomics model showed the highest AUC (0.95 [95% CI: 0.94, 0.96]) (P < .05). Conclusion The DL model accurately identified and delineated suspicious lesions on CEM images, and the combined output of the DL and handcrafted radiomics models achieved good diagnostic performance. © RSNA, 2023 Supplemental material is available for this article. See also the editorial by Bahl and Do in this issue.


Assuntos
Aprendizado Profundo , Humanos , Pessoa de Meia-Idade , Estudos Retrospectivos , Mamografia/métodos , Mama/diagnóstico por imagem , Curva ROC
8.
Radiology ; 308(3): e230367, 2023 09.
Artigo em Inglês | MEDLINE | ID: mdl-37750771

RESUMO

Background Background parenchymal enhancement (BPE) at breast MRI has been associated with increased breast cancer risk in several independent studies. However, variability of subjective BPE assessments have precluded its use in clinical practice. Purpose To examine the association between fully objective measures of BPE at MRI and odds of breast cancer. Materials and Methods This prospective case-control study included patients who underwent a bilateral breast MRI examination and were receiving care at one of three centers in the United States from November 2010 to July 2017. Breast volume, fibroglandular tissue (FGT) volume, and BPE were quantified using fully automated software. Fat volume was defined as breast volume minus FGT volume. BPE extent was defined as the proportion of FGT voxels with enhancement of 20% or more. Spearman rank correlation between quantitative BPE extent and Breast Imaging Reporting and Data System (BI-RADS) BPE categories assigned by an experienced board-certified breast radiologist was estimated. With use of multivariable logistic regression, breast cancer case-control status was regressed on tertiles (low, moderate, and high) of BPE, FGT volume, and fat volume, with adjustment for covariates. Results In total, 536 case participants with breast cancer (median age, 48 years [IQR, 43-55 years]) and 940 cancer-free controls (median age, 46 years [IQR, 38-55 years]) were included. BPE extent was positively associated with BI-RADS BPE (rs = 0.54; P < .001). Compared with low BPE extent (range, 2.9%-34.2%), high BPE extent (range, 50.7%-97.3%) was associated with increased odds of breast cancer (odds ratio [OR], 1.74 [95% CI: 1.23, 2.46]; P for trend = .002) in a multivariable model also including FGT volume (OR, 1.39 [95% CI: 0.97, 1.98]) and fat volume (OR, 1.46 [95% CI: 1.04, 2.06]). The association of high BPE extent with increased odds of breast cancer was similar for premenopausal and postmenopausal women (ORs, 1.75 and 1.83, respectively; interaction P = .73). Conclusion Objectively measured BPE at breast MRI is associated with increased breast cancer odds for both premenopausal and postmenopausal women. Clinical trial registration no. NCT02301767 © RSNA, 2023 Supplemental material is available for this article. See also the editorial by Bokacheva in this issue.


Assuntos
Neoplasias da Mama , Humanos , Feminino , Pessoa de Meia-Idade , Neoplasias da Mama/diagnóstico por imagem , Estudos de Casos e Controles , Imageamento por Ressonância Magnética , Mama/diagnóstico por imagem , Certificação
9.
Eur Radiol ; 33(9): 6213-6225, 2023 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-37138190

RESUMO

OBJECTIVES: To report mastectomy and reoperation rates in women who had breast MRI for screening (S-MRI subgroup) or diagnostic (D-MRI subgroup) purposes, using multivariable analysis for investigating the role of MRI referral/nonreferral and other covariates in driving surgical outcomes. METHODS: The MIPA observational study enrolled women aged 18-80 years with newly diagnosed breast cancer destined to have surgery as the primary treatment, in 27 centres worldwide. Mastectomy and reoperation rates were compared using non-parametric tests and multivariable analysis. RESULTS: A total of 5828 patients entered analysis, 2763 (47.4%) did not undergo MRI (noMRI subgroup) and 3065 underwent MRI (52.6%); of the latter, 2441/3065 (79.7%) underwent MRI with preoperative intent (P-MRI subgroup), 510/3065 (16.6%) D-MRI, and 114/3065 S-MRI (3.7%). The reoperation rate was 10.5% for S-MRI, 8.2% for D-MRI, and 8.5% for P-MRI, while it was 11.7% for noMRI (p ≤ 0.023 for comparisons with D-MRI and P-MRI). The overall mastectomy rate (first-line mastectomy plus conversions from conserving surgery to mastectomy) was 39.5% for S-MRI, 36.2% for P-MRI, 24.1% for D-MRI, and 18.0% for noMRI. At multivariable analysis, using noMRI as reference, the odds ratios for overall mastectomy were 2.4 (p < 0.001) for S-MRI, 1.0 (p = 0.957) for D-MRI, and 1.9 (p < 0.001) for P-MRI. CONCLUSIONS: Patients from the D-MRI subgroup had the lowest overall mastectomy rate (24.1%) among MRI subgroups and the lowest reoperation rate (8.2%) together with P-MRI (8.5%). This analysis offers an insight into how the initial indication for MRI affects the subsequent surgical treatment of breast cancer. KEY POINTS: • Of 3065 breast MRI examinations, 79.7% were performed with preoperative intent (P-MRI), 16.6% were diagnostic (D-MRI), and 3.7% were screening (S-MRI) examinations. • The D-MRI subgroup had the lowest mastectomy rate (24.1%) among MRI subgroups and the lowest reoperation rate (8.2%) together with P-MRI (8.5%). • The S-MRI subgroup had the highest mastectomy rate (39.5%) which aligns with higher-than-average risk in this subgroup, with a reoperation rate (10.5%) not significantly different to that of all other subgroups.


Assuntos
Neoplasias da Mama , Feminino , Humanos , Neoplasias da Mama/diagnóstico por imagem , Neoplasias da Mama/cirurgia , Mastectomia , Mastectomia Segmentar , Mama , Imageamento por Ressonância Magnética , Cuidados Pré-Operatórios
10.
Eur Radiol ; 2023 Nov 24.
Artigo em Inglês | MEDLINE | ID: mdl-37999727

RESUMO

OBJECTIVES: To investigate the influence of preoperative breast MRI on mastectomy and reoperation rates in patients with pure ductal carcinoma in situ (DCIS). METHODS: The MIPA observational study database (7245 patients) was searched for patients aged 18-80 years with pure unilateral DCIS diagnosed at core needle or vacuum-assisted biopsy (CNB/VAB) and planned for primary surgery. Patients who underwent preoperative MRI (MRI group) were matched (1:1) to those who did not receive MRI (noMRI group) according to 8 confounding covariates that drive referral to MRI (age; hormonal status; familial risk; posterior-to-nipple diameter; BI-RADS category; lesion diameter; lesion presentation; surgical planning at conventional imaging). Surgical outcomes were compared between the matched groups with nonparametric statistics after calculating odds ratios (ORs). RESULTS: Of 1005 women with pure unilateral DCIS at CNB/VAB (507 MRI group, 498 noMRI group), 309 remained in each group after matching. First-line mastectomy rate in the MRI group was 20.1% (62/309 patients, OR 2.03) compared to 11.0% in the noMRI group (34/309 patients, p = 0.003). The reoperation rate was 10.0% in the MRI group (31/309, OR for reoperation 0.40) and 22.0% in the noMRI group (68/309, p < 0.001), with a 2.53 OR of avoiding reoperation in the MRI group. The overall mastectomy rate was 23.3% in the MRI group (72/309, OR 1.40) and 17.8% in the noMRI group (55/309, p = 0.111). CONCLUSIONS: Compared to those going directly to surgery, patients with pure DCIS at CNB/VAB who underwent preoperative MRI had a higher OR for first-line mastectomy but a substantially lower OR for reoperation. CLINICAL RELEVANCE STATEMENT: When confounding factors behind MRI referral are accounted for in the comparison of patients with CNB/VAB-diagnosed pure unilateral DCIS, preoperative MRI yields a reduction of reoperations that is more than twice as high as the increase in overall mastectomies. KEY POINTS: • Confounding factors cause imbalance when investigating the influence of preoperative MRI on surgical outcomes of pure DCIS. • When patient matching is applied to women with pure unilateral DCIS, reoperation rates are significantly reduced in women who underwent preoperative MRI. • The reduction of reoperations brought about by preoperative MRI is more than double the increase in overall mastectomies.

11.
AJR Am J Roentgenol ; 221(1): 3-6, 2023 07.
Artigo em Inglês | MEDLINE | ID: mdl-36448912

RESUMO

Accumulating evidence shows that contrast-enhanced mammography (CEM) has higher diagnostic performance than digital mammography and ultrasound and comparable diagnostic performance to MRI for various indications. CEM also offers certain practical advantages for patients. Nevertheless, the clinical implementation of CEM has been limited because of a range of factors. This AJR Expert Panel Narrative Review explores such factors hindering CEM implementation. These factors include the following: the risks of iodinated contrast media, increased radiation exposure, indications for which CEM is not the preferred test or for which further evidence is needed, workflow adjustments needed when performing CEM examinations, incomplete availability of CEM-guided biopsy systems, and reimbursement challenges. Considerations that currently mitigate or are expected to mitigate these factors are also highlighted.


Assuntos
Neoplasias da Mama , Mamografia , Humanos , Feminino , Meios de Contraste , Exame Físico , Imageamento por Ressonância Magnética , Neoplasias da Mama/diagnóstico por imagem
12.
N Engl J Med ; 381(22): 2091-2102, 2019 11 28.
Artigo em Inglês | MEDLINE | ID: mdl-31774954

RESUMO

BACKGROUND: Extremely dense breast tissue is a risk factor for breast cancer and limits the detection of cancer with mammography. Data are needed on the use of supplemental magnetic resonance imaging (MRI) to improve early detection and reduce interval breast cancers in such patients. METHODS: In this multicenter, randomized, controlled trial in the Netherlands, we assigned 40,373 women between the ages of 50 and 75 years with extremely dense breast tissue and normal results on screening mammography to a group that was invited to undergo supplemental MRI or to a group that received mammography screening only. The groups were assigned in a 1:4 ratio, with 8061 in the MRI-invitation group and 32,312 in the mammography-only group. The primary outcome was the between-group difference in the incidence of interval cancers during a 2-year screening period. RESULTS: The interval-cancer rate was 2.5 per 1000 screenings in the MRI-invitation group and 5.0 per 1000 screenings in the mammography-only group, for a difference of 2.5 per 1000 screenings (95% confidence interval [CI], 1.0 to 3.7; P<0.001). Of the women who were invited to undergo MRI, 59% accepted the invitation. Of the 20 interval cancers that were diagnosed in the MRI-invitation group, 4 were diagnosed in the women who actually underwent MRI (0.8 per 1000 screenings) and 16 in those who did not accept the invitation (4.9 per 1000 screenings). The MRI cancer-detection rate among the women who actually underwent MRI screening was 16.5 per 1000 screenings (95% CI, 13.3 to 20.5). The positive predictive value was 17.4% (95% CI, 14.2 to 21.2) for recall for additional testing and 26.3% (95% CI, 21.7 to 31.6) for biopsy. The false positive rate was 79.8 per 1000 screenings. Among the women who underwent MRI, 0.1% had either an adverse event or a serious adverse event during or immediately after the screening. CONCLUSIONS: The use of supplemental MRI screening in women with extremely dense breast tissue and normal results on mammography resulted in the diagnosis of significantly fewer interval cancers than mammography alone during a 2-year screening period. (Funded by the University Medical Center Utrecht and others; DENSE ClinicalTrials.gov number, NCT01315015.).


Assuntos
Densidade da Mama , Neoplasias da Mama/diagnóstico por imagem , Detecção Precoce de Câncer/métodos , Imageamento por Ressonância Magnética , Mamografia , Idoso , Mama/diagnóstico por imagem , Mama/patologia , Neoplasias da Mama/epidemiologia , Reações Falso-Positivas , Feminino , Seguimentos , Humanos , Pessoa de Meia-Idade , Sensibilidade e Especificidade
13.
Eur Radiol ; 32(3): 1611-1623, 2022 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-34643778

RESUMO

OBJECTIVES: Preoperative breast magnetic resonance imaging (MRI) can inform surgical planning but might cause overtreatment by increasing the mastectomy rate. The Multicenter International Prospective Analysis (MIPA) study investigated this controversial issue. METHODS: This observational study enrolled women aged 18-80 years with biopsy-proven breast cancer, who underwent MRI in addition to conventional imaging (mammography and/or breast ultrasonography) or conventional imaging alone before surgery as routine practice at 27 centers. Exclusion criteria included planned neoadjuvant therapy, pregnancy, personal history of any cancer, and distant metastases. RESULTS: Of 5896 analyzed patients, 2763 (46.9%) had conventional imaging only (noMRI group), and 3133 (53.1%) underwent MRI that was performed for diagnosis, screening, or unknown purposes in 692/3133 women (22.1%), with preoperative intent in 2441/3133 women (77.9%, MRI group). Patients in the MRI group were younger, had denser breasts, more cancers ≥ 20 mm, and a higher rate of invasive lobular histology than patients who underwent conventional imaging alone (p < 0.001 for all comparisons). Mastectomy was planned based on conventional imaging in 22.4% (MRI group) versus 14.4% (noMRI group) (p < 0.001). The additional planned mastectomy rate in the MRI group was 11.3%. The overall performed first- plus second-line mastectomy rate was 36.3% (MRI group) versus 18.0% (noMRI group) (p < 0.001). In women receiving conserving surgery, MRI group had a significantly lower reoperation rate (8.5% versus 11.7%, p < 0.001). CONCLUSIONS: Clinicians requested breast MRI for women with a higher a priori probability of receiving mastectomy. MRI was associated with 11.3% more mastectomies, and with 3.2% fewer reoperations in the breast conservation subgroup. KEY POINTS: • In 19% of patients of the MIPA study, breast MRI was performed for screening or diagnostic purposes. • The current patient selection to preoperative breast MRI implies an 11% increase in mastectomies, counterbalanced by a 3% reduction of the reoperation rate. • Data from the MIPA study can support discussion in tumor boards when preoperative MRI is under consideration and should be shared with patients to achieve informed decision-making.


Assuntos
Neoplasias da Mama , Adolescente , Adulto , Idoso , Idoso de 80 Anos ou mais , Mama , Neoplasias da Mama/diagnóstico por imagem , Neoplasias da Mama/cirurgia , Feminino , Humanos , Imageamento por Ressonância Magnética , Mastectomia , Mastectomia Segmentar , Pessoa de Meia-Idade , Cuidados Pré-Operatórios , Adulto Jovem
14.
Ann Surg ; 273(4): 694-700, 2021 04 01.
Artigo em Inglês | MEDLINE | ID: mdl-33201095

RESUMO

OBJECTIVE: The purpose of this study was to perform a systematic review and meta-analysis to determine the diagnostic performance of current noninvasive imaging modalities for assessment of axillary response after neoadjuvant systemic therapy (NST) in clinically node-positive breast cancer patients. SUMMARY OF BACKGROUND DATA: NST can lead to downstaging of axillary lymph node disease. Imaging can potentially provide information about the axillary response to NST and, consequently, tailor the surgical management. METHODS: PubMed and Embase were searched for studies that compared noninvasive imaging after NST with axillary surgery outcome to identify axillary response in patients with initial pathologically proven axillary lymph node metastasis. Two reviewers independently screened the studies and extracted the data. A meta-analysis was performed by computing the pooled sensitivity, specificity, positive predictive value (PPV), and negative predictive value (NPV). RESULTS: Thirteen studies describing 2380 patients were included for final analysis. Of these patients, 1322 had undergone axillary ultrasound, 849 breast MRI, and 209 whole-body 18F-FDG PET-CT. The overall axillary pathologic complete response rate was 39.5% (941/2380). For axillary ultrasound, the pooled sensitivity, specificity, PPV, and NPV were 65%, 69%, 77%, 50%, respectively. For breast MRI, the pooled sensitivity, specificity, PPV, and NPV were 60%, 76%, 78%, 58%, respectively. For whole-body 18F-FDG PET-CT, the pooled sensitivity, specificity, PPV, and NPV were 38%, 86%, 78%, 49%, respectively. CONCLUSIONS: The diagnostic performance of current noninvasive imaging modalities is limited to accurately assess axillary response after NST in clinically node-positive breast cancer patients.


Assuntos
Neoplasias da Mama/diagnóstico , Linfonodos/diagnóstico por imagem , Imagem Multimodal/métodos , Axila , Neoplasias da Mama/secundário , Neoplasias da Mama/terapia , Feminino , Humanos , Metástase Linfática , Imageamento por Ressonância Magnética/métodos , Terapia Neoadjuvante , Tomografia por Emissão de Pósitrons/métodos , Reprodutibilidade dos Testes , Tomografia Computadorizada por Raios X/métodos
15.
Radiology ; 299(1): 36-48, 2021 04.
Artigo em Inglês | MEDLINE | ID: mdl-33650905

RESUMO

Contrast-enhanced mammography (CEM) has emerged as a viable alternative to contrast-enhanced breast MRI, and it may increase access to vascular imaging while reducing examination cost. Intravenous iodinated contrast materials are used in CEM to enhance the visualization of tumor neovascularity. After injection, imaging is performed with dual-energy digital mammography, which helps provide a low-energy image and a recombined or iodine image that depict enhancing lesions in the breast. CEM has been demonstrated to help improve accuracy compared with digital mammography and US in women with abnormal screening mammographic findings or symptoms of breast cancer. It has also been demonstrated to approach the accuracy of breast MRI in preoperative staging of patients with breast cancer and in monitoring response after neoadjuvant chemotherapy. There are early encouraging results from trials evaluating CEM in the screening of women who are at an increased risk of breast cancer. Although CEM is a promising tool, it slightly increases radiation dose and carries a small risk of adverse reactions to contrast materials. This review details the CEM technique, diagnostic and screening uses, and future applications, including artificial intelligence and radiomics.


Assuntos
Neoplasias da Mama/diagnóstico por imagem , Meios de Contraste , Mamografia/tendências , Inteligência Artificial , Detecção Precoce de Câncer , Feminino , Previsões , Humanos , Imageamento por Ressonância Magnética , Doses de Radiação
16.
Radiology ; 301(2): 283-292, 2021 11.
Artigo em Inglês | MEDLINE | ID: mdl-34402665

RESUMO

Background High breast density increases breast cancer risk and lowers mammographic sensitivity. Supplemental MRI screening improves cancer detection but increases the number of false-positive screenings. Thus, methods to distinguish true-positive MRI screening results from false-positive ones are needed. Purpose To build prediction models based on clinical characteristics and MRI findings to reduce the rate of false-positive screening MRI findings in women with extremely dense breasts. Materials and Methods Clinical characteristics and MRI findings in Dutch breast cancer screening participants (age range, 50-75 years) with positive first-round MRI screening results (Breast Imaging Reporting and Data System 3, 4, or 5) after a normal screening mammography with extremely dense breasts (Volpara density category 4) were prospectively collected within the randomized controlled Dense Tissue and Early Breast Neoplasm Screening (DENSE) trial from December 2011 through November 2015. In this secondary analysis, prediction models were built using multivariable logistic regression analysis to distinguish true-positive MRI screening findings from false-positive ones. Results Among 454 women (median age, 52 years; interquartile range, 50-57 years) with a positive MRI result in a first supplemental MRI screening round, 79 were diagnosed with breast cancer (true-positive findings), and 375 had false-positive MRI results. The full prediction model (area under the receiver operating characteristics curve [AUC], 0.88; 95% CI: 0.84, 0.92), based on all collected clinical characteristics and MRI findings, could have prevented 45.5% (95% CI: 39.6, 51.5) of false-positive recalls and 21.3% (95% CI: 15.7, 28.3) of benign biopsies without missing any cancers. The model solely based on readily available MRI findings and age had a comparable performance (AUC, 0.84; 95% CI: 0.79, 0.88; P = .15) and could have prevented 35.5% (95% CI: 30.4, 41.1) of false-positive MRI screening results and 13.0% (95% CI: 8.8, 18.6) of benign biopsies. Conclusion Prediction models based on clinical characteristics and MRI findings may be useful to reduce the false-positive first-round screening MRI rate and benign biopsy rate in women with extremely dense breasts. Clinical trial registration no. NCT01315015 © RSNA, 2021 Online supplemental material is available for this article. See also the editorial by Imbriaco in this issue.


Assuntos
Densidade da Mama , Neoplasias da Mama/diagnóstico por imagem , Imageamento por Ressonância Magnética/métodos , Idoso , Mama/diagnóstico por imagem , Reações Falso-Positivas , Feminino , Humanos , Pessoa de Meia-Idade , Países Baixos , Estudos Prospectivos , Reprodutibilidade dos Testes , Sensibilidade e Especificidade
17.
Radiology ; 299(2): 278-286, 2021 05.
Artigo em Inglês | MEDLINE | ID: mdl-33724062

RESUMO

Background In the first (prevalent) supplemental MRI screening round of the Dense Tissue and Early Breast Neoplasm Screening (DENSE) trial, a considerable number of breast cancers were found at the cost of an increased false-positive rate (FPR). In incident screening rounds, a lower cancer detection rate (CDR) is expected due to a smaller pool of prevalent cancers, and a reduced FPR, due to the availability of prior MRI examinations. Purpose To investigate screening performance indicators of the second round (incidence round) of the DENSE trial. Materials and Methods The DENSE trial (ClinicalTrials.gov: NCT01315015) is embedded within the Dutch population-based biennial mammography screening program for women aged 50-75 years. MRI examinations were performed between December 2011 and January 2016. Women were eligible for the second round when they again had a negative screening mammogram 2 years after their first MRI. The recall rate, biopsy rate, CDR, FPR, positive predictive values, and distributions of tumor characteristics were calculated and compared with results of the first round using 95% CIs and χ2 tests. Results A total of 3436 women (median age, 56 years; interquartile range, 48-64 years) underwent a second MRI screening. The CDR was 5.8 per 1000 screening examinations (95% CI: 3.8, 9.0) compared with 16.5 per 1000 screening examinations (95% CI: 13.3, 20.5) in the first round. The FPR was 26.3 per 1000 screening examinations (95% CI: 21.5, 32.3) in the second round versus 79.8 per 1000 screening examinations (95% CI: 72.4, 87.9) in the first round. The positive predictive value for recall was 18% (20 of 110 participants recalled; 95% CI: 12.1, 26.4), and the positive predictive value for biopsy was 24% (20 of 84 participants who underwent biopsy; 95% CI: 16.0, 33.9), both comparable to that of the first round. All tumors in the second round were stage 0-I and node negative. Conclusion The incremental cancer detection rate in the second round was 5.8 per 1000 screening examinations-compared with 16.5 per 1000 screening examinations in the first round. This was accompanied by a strong reduction in the number of false-positive results. © RSNA, 2021 Online supplemental material is available for this article. See also the editorial by Moy and Gao in this issue.


Assuntos
Densidade da Mama , Neoplasias da Mama/diagnóstico por imagem , Imageamento por Ressonância Magnética , Programas de Rastreamento/métodos , Biópsia , Neoplasias da Mama/epidemiologia , Detecção Precoce de Câncer , Reações Falso-Positivas , Feminino , Humanos , Incidência , Pessoa de Meia-Idade , Países Baixos/epidemiologia
18.
Prev Med ; 151: 106602, 2021 10.
Artigo em Inglês | MEDLINE | ID: mdl-34217417

RESUMO

The COVID-19 pandemic forced the Dutch national breast screening program to a halt in week 12, 2020. In week 26, the breast program was resumed at 40% capacity, which increased to 60% in week 34. We examined the impact of the suspension and restart of the screening program on the incidence of screen-detected and non-screen-detected breast cancer. We selected women aged 50-74, diagnosed during weeks 2-35 of 2018 (n = 7250), 2019 (n = 7302), or 2020 (n = 5306), from the Netherlands Cancer Registry. Weeks 2-35 were divided in seven periods, based on events occurring at the start of the COVID-19 pandemic. Incidence of screen-detected and non-screen-detected tumors was calculated overall and by age group, cT-stage, and cTNM-stage for each period in 2020, and compared to the incidence in the same period of 2018/2019 (averaged). The incidence of screen-detected tumors decreased during weeks 12-13, reached almost zero during weeks 14-25, and increased during weeks 26-35. Incidence of non-screen-detected tumors decreased to a lesser extent during weeks 12-16. The decrease in incidence was seen in all age groups and mainly occurred for cTis, cT1, DCIS, and stage I tumors. Due to the suspension of the breast cancer screening program, and the restart at reduced capacity, the incidence of screen-detected breast tumors decreased by 67% during weeks 9-35 2020, which equates to about 2000 potentially delayed breast cancer diagnoses. Up to August 2020 there was no indication of a shift towards higher stage breast cancers after restart of the screening.


Assuntos
Neoplasias da Mama , COVID-19 , Neoplasias da Mama/diagnóstico , Neoplasias da Mama/epidemiologia , Detecção Precoce de Câncer , Feminino , Humanos , Incidência , Mamografia , Programas de Rastreamento , Países Baixos/epidemiologia , Pandemias , SARS-CoV-2
19.
Ann Surg ; 271(3): 574-580, 2020 03.
Artigo em Inglês | MEDLINE | ID: mdl-30557203

RESUMO

OBJECTIVE: The aim was to investigate whether pathologic complete response (pCR) in the breast is correlated with absence of axillary lymph node metastases at final pathology (ypN0) in patients treated with neoadjuvant systemic therapy (NST) for different breast cancer subtypes. BACKGROUND: Pathologic complete response rates have improved on account of more effective systemic treatment regimens. Promising results in feasibility trials with percutaneous image-guided tissue sampling for the identification of breast pCR after NST raise the question whether breast surgery is a redundant procedure. Thereby, the need for axillary surgery should be reconsidered as well. METHODS: Patients diagnosed with cT1-3N0-1 breast cancer and treated with NST, followed by surgery between 2010 and 2016, were selected from the Netherlands Cancer Registry. Patients were compared according to the pathologic response of the primary tumor with associated pathologic axillary outcome. Multivariable analysis was performed to determine clinicopathological variables correlated with ypN0. RESULTS: A total of 4084 patients were included for analyses, of whom 986 (24.1%) achieved breast pCR. In clinically node negative patients (cN0), 97.7% (432/442) with breast pCR had ypN0 compared with 71.6% (882/1232) without breast pCR (P < 0.001). In clinically node positive patients (cN1), 45.0% (245/544) with breast pCR had ypN0 compared with 9.4% (176/1866) without breast pCR (P < 0.001). The odds of ypN0 was decreased in case of clinical T3 stage (OR 0.59, 95% CI 0.40-0.87), cN1 (OR 0.03, 95% CI 0.02-0.04) and ER+HER2- subtype (OR 0.30, 95% CI 0.20-0.44), and increased in case of breast pCR (OR 4.53, 95% CI 3.27-6.28). CONCLUSIONS: Breast pCR achieved after NST is strongly correlated with ypN0 in cN0 patients, especially in ER+HER2+, ER-HER2+, and triple negative subtypes. These results provide data to proceed with future clinical trials to investigate if axillary surgery can be safely omitted in these selected patients when image-guided tissue sampling identifies a breast pCR.


Assuntos
Protocolos de Quimioterapia Combinada Antineoplásica , Neoplasias da Mama/tratamento farmacológico , Neoplasias da Mama/patologia , Neoplasias da Mama/cirurgia , Terapia Neoadjuvante/métodos , Adolescente , Adulto , Idoso , Idoso de 80 Anos ou mais , Quimioterapia Adjuvante , Feminino , Humanos , Metástase Linfática , Pessoa de Meia-Idade , Estadiamento de Neoplasias
20.
Eur Radiol ; 30(8): 4212-4222, 2020 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-32221685

RESUMO

OBJECTIVES: To investigate whether breast MRI has comparable diagnostic performance as dedicated axillary MRI regarding assessment of node-negative and node-positive breast cancer. METHODS: Forty-seven patients were included. All had undergone both breast MRI and dedicated axillary MRI, followed by surgery. All included breast MRI exams had complete field of view (FOV) of the axillary region. First, unenhanced T2-weighted (T2W) and subsequent diffusion-weighted (DW) images of both MRI exams were independently analyzed by two breast radiologists using a confidence scale and compared to histopathology. ADC values were measured by two researchers independently. Diagnostic performance parameters were calculated on a patient-by-patient basis. RESULTS: T2W breast MRI had the following diagnostic performance: sensitivity of 50.0% and 62.5%, specificity of 92.3%, PPV of 57.1% and 62.5%, NPV of 90.0% and 92.3%, and AUC of 0.72 for reader 1 and 0.78 for reader 2. T2W dedicated axillary MRI had the following diagnostic performance: sensitivity of 37.5% and 62.5%, specificity of 82.1% and 92.3%, PPV of 44.6% and 50.0%, NPV of 87.8% and 91.4%, and AUC of 0.65 for reader 1 and 0.73 for reader 2. In both evaluations, addition of DW images resulted in comparable diagnostic performance. For both breast MRI and dedicated axillary MRI, there was no significant difference between mean ADC values of benign and malignant lymph nodes. CONCLUSIONS: T2W breast MRI with complete FOV of the axillary region has comparable diagnostic performance as T2W dedicated axillary MRI regarding assessment of node-negative and node-positive breast cancer. Optimization of T2W breast MRI protocol by including a complete FOV of the axillary region can, therefore, be recommended in clinical practice. KEY POINTS: • Breast MRI with complete field of view of the axillary region has comparable diagnostic performance as dedicated axillary MRI regarding assessment of node-negative and node-positive breast cancer. • Optimization of breast MRI protocol by including a complete field of view of the axillary region is recommended in clinical practice. • For both breast MRI and dedicated axillary MRI, DW imaging (including ADC measurements) is of no added value.


Assuntos
Neoplasias da Mama/diagnóstico por imagem , Neoplasias da Mama/patologia , Linfonodos/diagnóstico por imagem , Metástase Linfática/diagnóstico por imagem , Imageamento por Ressonância Magnética/métodos , Idoso , Axila/patologia , Mama/diagnóstico por imagem , Mama/patologia , Imagem de Difusão por Ressonância Magnética/métodos , Feminino , Humanos , Linfonodos/patologia , Pessoa de Meia-Idade , Estudos Retrospectivos , Sensibilidade e Especificidade
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA