Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 74
Filtrar
1.
Exp Cell Res ; 436(1): 113958, 2024 Mar 01.
Artigo em Inglês | MEDLINE | ID: mdl-38325585

RESUMO

Cerebral amyloid angiopathy (CAA) is a disease in which amyloid ß (Aß) is deposited in the cerebral blood vessels, reducing compliance, tearing and weakening of vessel walls, leading to cerebral hemorrhage. The mechanisms by which Aß leads to focal wall fragmentation and intimal damage are not well understood. We analyzed the motility of human brain microvascular endothelial cells (hBMECs) in real-time using a wound-healing assay. We observed the suppression of cell migration by visualizing Aß aggregation using quantum dot (QD) nanoprobes. In addition, using QD nanoprobes and a SiR-actin probe, we simultaneously observed Aß aggregation and F-actin organization in real-time for the first time. Aß began to aggregate at the edge of endothelial cells, reducing cell motility. In addition, Aß aggregation disorganized the actin cytoskeleton and induced abnormal actin aggregation. Aß aggregated actively in the anterior group, where cell motility was active. Our findings may be a first step toward explaining the mechanism by which Aß causes vascular wall fragility, bleeding, and rebleeding in CAA.


Assuntos
Peptídeos beta-Amiloides , Células Endoteliais , Humanos , Peptídeos beta-Amiloides/farmacologia , Actinas , Encéfalo , Citoesqueleto de Actina
2.
Neurosurg Rev ; 47(1): 207, 2024 May 07.
Artigo em Inglês | MEDLINE | ID: mdl-38713250

RESUMO

A major challenge within the academic literature on SDHs has been inconsistent outcomes reported across studies. Historically, patients have been categorized by the blood-product age identified on imaging (i.e., acute, subacute, or chronic). However, this schematic has likely played a central role in producing the heterogeneity encountered in the literature. In this investigation, a total of 494 patients that underwent SDH evacuation at a tertiary medical center between November 2013-December 2021 were retrospectively identified. Mechanism of injury was reviewed by the authors and categorized as either positive or negative for a high-velocity impact (HVI) injury. Any head strike injury leading to the formation of a SDH while traveling at a velocity beyond that of normal locomotion or daily activities was categorized as an HVI. Patients were subsequently stratified by those with an acute SDHs after a high-velocity impact (aSDHHVI), those with an acute SDH without a high-velocity impact injury (aSDHWO), and those with any combination of subacute or chronic blood products (mixed-SDH [mSDH]). Nine percent (n = 44) of patients experienced an aSDHHVI, 23% (n = 113) aSDHWO, and 68% (n = 337) mSDH. Between these groups, highly distinct patient populations were identified using several metrics for comparison. Most notably, aSDHHVI had a significantly worse neurological status at discharge (50% vs. 23% aSDHWO vs. 8% mSDH; p < 0.001) and mortality (25% vs. 8% aSDHWO vs. 4% mSDH; p < 0.001). Controlling for gender, midline shift (mm), and anticoagulation use in the acute SDH population, multivariable logistic regression revealed a 6.85x odds ratio (p < 0.001) for poor outcomes in those with a positive history for a high-velocity impact injury. As such, the distribution of patients that suffer an HVI related acute SDH versus those that do not can significantly affect the outcomes reported. Adoption of this stratification system will help address the heterogeneity of SDH reporting in the literature while still closely aligning with conventional reporting.


Assuntos
Hematoma Subdural , Humanos , Feminino , Masculino , Pessoa de Meia-Idade , Idoso , Adulto , Estudos Retrospectivos , Resultado do Tratamento , Idoso de 80 Anos ou mais
3.
J Cardiothorac Vasc Anesth ; 35(5): 1439-1446, 2021 May.
Artigo em Inglês | MEDLINE | ID: mdl-32888805

RESUMO

OBJECTIVES: The CNAP system is a noninvasive monitor that provides a continuous arterial pressure waveform using an inflatable finger cuff. The authors hypothesized that dramatic changes in systemic vascular resistance index during abdominal aortic aneurysm (AAA) surgery might affect the accuracy of noninvasive pulse contour monitors. The aim of this study was to evaluate the accuracy and trending ability of cardiac index derived by the CNAP system (CICN) in patients undergoing AAA surgery. DESIGN: Prospective clinical study. SETTING: Cardiac surgery operating room in a single cardiovascular center. PARTICIPANTS: Twenty patients who underwent elective AAA surgery. INTERVENTIONS: CICN and cardiac index measured using 3-dimensional images (CI3D) were determined simultaneously at 8 points during the surgery. At aortic clamping and unclamping, the authors tested the trending ability of CICN using 4-quadrant plot analysis and polar plot analysis. MEASUREMENTS AND MAIN RESULTS: The authors found a wide limit of agreement between CICN and CI3D (percentage error: 85.0%). The cubic splines, which show the relationship between systemic vascular resistance index and percentage CI discrepancy [(CICN-CI3D)/CI3D], were sloped positively. Four-quadrant plot analysis showed poor trending ability for CICN at both aortic clamping and unclamping (concordance rate: 29.4% and 57.9%, respectively). In the polar plot analysis, the concordance rates at aortic clamping and unclamping were 15.0% and 35.0%, respectively. CONCLUSIONS: CICN is not interchangeable with CI3D in patients undergoing AAA surgery. The trending ability for CICN at aortic clamping and unclamping was below the acceptable limit. These inaccuracies might be secondary to the high systemic vascular resistance index during AAA surgery.


Assuntos
Aneurisma da Aorta Abdominal , Aneurisma da Aorta Abdominal/diagnóstico por imagem , Aneurisma da Aorta Abdominal/cirurgia , Pressão Arterial , Débito Cardíaco , Humanos , Monitorização Fisiológica , Estudos Prospectivos , Termodiluição
4.
J Stroke Cerebrovasc Dis ; 30(11): 106066, 2021 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-34488006

RESUMO

OBJECTIVES: This study aimed to prove the safety and efficacy of the contact aspiration using non-penetrating of thrombus (CANP) technique for the initial procedure for acute ischemic stroke and to increase operator familiarization with the technical aspects of the CANP technique. MATERIALS AND METHODS: A total of 103 patients with large-vessel stroke who were treated using thrombectomy alone at our institution between April 2019 and March 2021 were included in this study. CANP technique was performed using a large lumen catheter (inner diameter, ≥0.060 in.) without penetrating a thrombus. Results of the CANP technique, including the procedure time; first-pass effect (FPE); angiographical recanalization; functional independence; thrombus migration; and intracerebral hemorrhage (ICH) were compared with combined technique. RESULTS: A total of 77 patients (74.8%) were scheduled to undergo the CANP technique for initial procedure, and 50 (64.9%) attempted the CANP technique. Of 50 patients with CANP technique, 33 (66.0%) achieved angiographically good recanalization using CANP technique alone. FPE was achieved in 31 patients (62.0%) in CANP technique group; the rate of FPE was significantly higher (p = 0.008). Asymptomatic ICH were significantly smaller in the CANP technique group (p = 0.008). The median interval of only the CANP technique was 20 (IQR, 16-29.5) min for groin puncture to final recanalization, and was significantly faster (p < 0.001). CONCLUSIONS: CANP technique was safe with low risk of hemorrhagic complication and effective for the initial procedure of acute ischemic stroke.


Assuntos
AVC Isquêmico , Trombectomia , Humanos , AVC Isquêmico/cirurgia , Trombectomia/métodos , Resultado do Tratamento
5.
J Cardiothorac Vasc Anesth ; 34(12): 3293-3299, 2020 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-32404245

RESUMO

OBJECTIVES: To investigate the accuracy and trending ability of ClearSight (Edwards Lifesciences, Irvine, CA) in patients with reduced ejection fraction (<55%) undergoing off-pump coronary artery bypass graft (CABG) surgery by comparing the ClearSight-derived cardiac index (CICS) with the cardiac index measured with thermodilution using a pulmonary artery catheter. In addition, the accuracy and trending ability of ClearSight for blood pressure measurement was investigated by comparing the mean arterial pressure (MAP) derived by ClearSight (MAPcs) with invasive intra-arterial pressure. DESIGN: Prospective clinical study. DESIGN: Cardiac surgery operating room in a single cardiovascular center. PARTICIPANTS: The study comprised 20 patients who underwent elective CABG surgery. INTERVENTIONS: MAP and cardiac index were measured simultaneously at 6 time points intraoperatively. Trending ability was investigated at the following 2 points: (1) before and after placing the patient in the Trendelenburg position and (2) before and after atrial pacing with a targeted heart rate increase of 20%. MEASUREMENTS AND MAIN RESULTS: Bland-Altman analysis showed that the percentage error between CICS and the cardiac index measured with thermodilution was 40.2% and the percentage error between MAPcs and MAP was 24.6%. Four-quadrant plot analysis showed that the tracking ability of CICS with the Trendelenburg position and atrial pacing was below the good trending ability cutoff (92%). However, the concordance rate of the 4-quadrant plot analysis showed a good trending ability for MAPcs. The polar plot analysis showed the same trend. CONCLUSIONS: CICS was not sufficiently accurate in patients with reduced ejection fraction undergoing off-pump CABG surgery. However, ClearSight was clinically acceptable for MAP regarding its accuracy and trending ability in patients with reduced ejection fraction.


Assuntos
Monitorização Intraoperatória , Termodiluição , Pressão Sanguínea , Débito Cardíaco , Humanos , Estudos Prospectivos , Reprodutibilidade dos Testes , Volume Sistólico
7.
J Cardiothorac Vasc Anesth ; 33(2): 321-327, 2019 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-30057251

RESUMO

OBJECTIVES: To investigate whether administering fibrinogen concentrate or cryoprecipitate is associated with increased postoperative thromboembolic events and improved mortality in patients undergoing thoracic aortic surgery. DESIGN: Multicenter retrospective cohort study using propensity-score analyses and multivariate logistic regression analysis to control for confounders. SETTING: Four hospitals (1 national cardiovascular center and 3 university hospitals). PARTICIPANTS: Patients undergoing thoracic aortic surgery with cardiopulmonary bypass between January 2010 and October 2012 (n = 1,047). INTERVENTIONS: Outcomes in patients treated with fibrinogen concentrate or cryoprecipitate (fibrinogen group) were compared with those who did not receive these products (no fibrinogen group) based on propensity-score matching. Multivariate logistic regression analysis then was performed to confirm the results. MEASUREMENTS AND MAIN RESULTS: Among 1,047 patients enrolled in this study, 247 patients received fibrinogen concentrate or cryoprecipitate. The median amount of administered fibrinogen was 3 g (interquartile range 2-4 g). Eighty-seven patients were excluded from the propensity-score matching because of missing data. Propensity-score-matched analysis showed no significant difference in the incidence of thromboembolic events or 30-day mortality rate between the groups. Multivariate analysis revealed that the fibrinogen group showed no significant difference in thromboembolic events (odds ratio 1.22; 95% confidence interval 0.76-1.95; p = 0.408) or mortality rate (odds ratio 0.44; 95% confidence interval 0.18-1.12; p = 0.081) compared with those in the no fibrinogen group. CONCLUSIONS: Administering fibrinogen concentrate or cryoprecipitate was associated with neither thromboembolic events nor 30-day mortality in patients undergoing thoracic aortic surgery. Administering fibrinogen concentrate or cryoprecipitate is safe and does not appear to increase thromboembolic events and mortality in thoracic aortic surgery patients.


Assuntos
Aneurisma da Aorta Torácica/cirurgia , Procedimentos Cirúrgicos Cardiovasculares/efeitos adversos , Fibrinogênio/administração & dosagem , Hemorragia Pós-Operatória/prevenção & controle , Tromboembolia/epidemiologia , Idoso , Aneurisma da Aorta Torácica/sangue , Fatores de Coagulação Sanguínea/administração & dosagem , Bases de Dados Factuais , Feminino , Hemostáticos/administração & dosagem , Humanos , Incidência , Japão/epidemiologia , Masculino , Pessoa de Meia-Idade , Hemorragia Pós-Operatória/sangue , Hemorragia Pós-Operatória/mortalidade , Prognóstico , Estudos Retrospectivos , Taxa de Sobrevida/tendências , Tromboembolia/sangue , Tromboembolia/etiologia
8.
J Clin Monit Comput ; 33(5): 767-776, 2019 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-30406422

RESUMO

To compare the accuracy and trending ability of the cardiac index (CI) measured by FloTrac/Vigileo™ (CIFT) or derived by the Fick equation (CIFick) using E-CAiOVX (enables continuous monitoring of oxygen consumption) with that measured by thermodilution (CITD) in patients with off-pump coronary artery bypass surgery. Twenty-two patients undergoing elective off-pump coronary artery bypass surgery were included. CIFT and CIFick were determined simultaneously at six time-points during off-pump coronary artery bypass surgery. At each time-point, phenylephrine (50 µg) was administered to increase systematic vascular resistance, with CI measured before and after administration (CITD used as reference method). Agreement of each method was evaluated by Bland-Altman analysis, while trending ability was evaluated by four-quadrant plot analysis and polar plot analysis. By Bland-Altman analysis, CIFT and CIFick showed percentage errors of 49.5% and 78.6%, respectively, compared with CITD. Subgroup analysis showed a percentage error between COFT and COTD of 28.9% in patients with a CI ≥ 2.4 L/min/m2, and 78.1% in patients with a CI ≥ 2.4 L/min/m2. The concordance rate of four-quadrant plot analysis was 93.3% for CIFT and 66.7% for CIFick in datasets where CITD ≥ 2.4 L/min/m2 before and after phenylephrine administration were included. CIFT and CIFick had wide limits of agreement with CITD, and were below acceptable limits for tracking phenylephrine-induced CI changes. However, subgroup analysis showed improved accuracy and trending ability of CIFT when only points where CITD ≥ 2.4 L/min/m2 were included, while there was no improvement in CIFick accuracy or trending ability.


Assuntos
Débito Cardíaco , Monitorização Intraoperatória/instrumentação , Monitorização Intraoperatória/métodos , Adulto , Idoso , Idoso de 80 Anos ou mais , Ponte de Artéria Coronária sem Circulação Extracorpórea , Feminino , Hemodinâmica , Humanos , Masculino , Pessoa de Meia-Idade , Oxigênio/metabolismo , Consumo de Oxigênio , Fenilefrina/farmacologia , Estudos Prospectivos , Artéria Pulmonar , Reprodutibilidade dos Testes , Termodiluição , Resistência Vascular
9.
J Anesth ; 33(2): 304-310, 2019 04.
Artigo em Inglês | MEDLINE | ID: mdl-30863956

RESUMO

PURPOSE: Fulminant myocarditis is uncommon, but life-threatening, and some patients need mechanical circulatory support. This study was performed to evaluate how different types of mechanical circulatory support-biventricular assist device (BiVAD) or left ventricular assist device (LVAD) placement-affect intraoperative hemodynamic status. METHODS: From January 2013 to September 2016, the patients who underwent BiVAD or LVAD placement for fulminant myocarditis were analyzed. The mean arterial pressure (MAP), mean pulmonary arterial pressure, central venous pressure (CVP), vasoactive score, and inotropic score were recorded at five time points: after the induction of anesthesia; at weaning, 30 min after weaning, and 60 min after weaning from cardiopulmonary bypass (CPB); and at the end of surgery. The vasoactive and inotropic scores were calculated as follows: vasoactive score = norepinephrine (µg/kg/min) × 100 + milrinone (µg/kg/min) × 10 + olprinone (µg/kg/min) × 25: inotropic score = dopamine (µg/kg/min) × 1 + dobutamine (µg/kg/min) × 1 + epinephrine (µg/kg/min) × 100. RESULTS: We enrolled 16 patients of fulminant myocarditis. Ten of them underwent BiVAD placement, and the other underwent LVAD placement. After weaning from CPB, the BiVAD group had a significantly lower MAP but no difference in CVP. The vasoactive score was significantly higher in the BiVAD group at weaning of CPB (p = 0.015), 30 min after weaning (p = 0.004), 60 min after weaning (p = 0.005), and at the end of surgery (p < 0.016). CONCLUSION: Patients with BiVAD placement required more vasoactive support to maintain optimal hemodynamic status compared with those with LVAD placement. This result indicates that BiVAD placement was more associated with vasoplegic syndrome.


Assuntos
Coração Auxiliar , Miocardite/terapia , Vasoplegia/epidemiologia , Adulto , Idoso , Pressão Arterial , Ponte Cardiopulmonar/métodos , Pressão Venosa Central , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Retrospectivos , Resultado do Tratamento
10.
J Anesth ; 33(3): 364-371, 2019 06.
Artigo em Inglês | MEDLINE | ID: mdl-30904953

RESUMO

PURPOSE: The ClearSight™ device monitors continuous pressure and cardiac output via pulse contour analysis. ClearSight™, however, may not be reliable in patients with reduced peripheral perfusion caused by high peripheral resistance. This study aimed to elucidate the accuracy and trending ability of ClearSight™ in patients undergoing abdominal aortic aneurysm (AAA) surgery by comparing the ClearSightTM-derived cardiac index (CICS) with that measured using three-dimensional echocardiography (CI3D). METHODS: The study included 20 patients who underwent elective AAA surgery. CICS and CI3D were measured simultaneously at eight time points during the surgery. Trending ability was investigated after aortic clamping and unclamping. We used CI3D as the reference method. RESULTS: Bland-Altman analysis showed a wide limit of agreement between CICS and CI3D (percentage error 41.3%). Subgroup analysis showed a lower percentage error (33.2%) in patients with CI ≥ 2.5 L/min/m2. The cubic splines related to the CI3D and CI discrepancy were negatively sloped, indicating that CI3D had significant influence on the CI discrepancy (p < 0.001). Four-quadrant plot analysis showed that the tracking ability of ClearSight™ after aortic clamping and declamping were clinically unacceptable (81.3% and 78.6%, respectively). Also, the polar plot analysis showed that the concordance rate of ClearSight™ after aortic clamping and declamping were clinically unacceptable (58.3% and 66.7%, respectively). CONCLUSIONS: ClearSight™ was not sufficiently accurate in patients undergoing AAA surgery. The tracking ability of ClearSight™ after aortic clamping was below the acceptable limit.


Assuntos
Aneurisma da Aorta Abdominal/cirurgia , Monitorização Hemodinâmica/métodos , Idoso , Débito Cardíaco/fisiologia , Ecocardiografia Tridimensional/métodos , Feminino , Frequência Cardíaca/fisiologia , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos
11.
Anesthesiology ; 138(5): 533-534, 2023 05 01.
Artigo em Inglês | MEDLINE | ID: mdl-36930270
12.
Pediatr Crit Care Med ; 19(12): e637-e642, 2018 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-30199511

RESUMO

OBJECTIVES: The present study aimed to examine the association between tranexamic acid use and adverse effects (seizures, thromboembolism, and renal dysfunction) in a pediatric trauma population using a national inpatient database in Japan. We also assessed the association between tranexamic acid use and in-hospital mortality. DESIGN: A nationwide, retrospective cohort study using propensity score analyses. SETTING: Japanese Diagnosis Procedure Combination inpatient database. PATIENTS: Pediatric patients less than or equal to 12 years old admitted in hospital with the diagnosis of trauma between July 2010 and March 2014 (n = 61,779). INTERVENTIONS: None. MEASUREMENTS AND MAIN RESULTS: Propensity score matching created 1,914 pairs of patients with and without tranexamic acid administration. Propensity-matched analysis showed that the proportion of seizures was significantly higher in the tranexamic acid group than in the nontranexamic acid group (7/1,914, 0.37% vs 0/1,914, 0%; difference, 0.37%; 95% CI, 0.10-0.64; p = 0.008). However, none of the other outcomes were significantly different between the groups. CONCLUSIONS: Tranexamic acid use is associated with a significantly increased risk of seizures. However, no difference exists among any other outcomes between the tranexamic acid and nontranexamic acid groups.


Assuntos
Antifibrinolíticos/efeitos adversos , Convulsões/induzido quimicamente , Ácido Tranexâmico/efeitos adversos , Ferimentos e Lesões/tratamento farmacológico , Injúria Renal Aguda/induzido quimicamente , Injúria Renal Aguda/epidemiologia , Estudos de Casos e Controles , Criança , Pré-Escolar , Bases de Dados Factuais , Feminino , Mortalidade Hospitalar , Humanos , Unidades de Terapia Intensiva Pediátrica/estatística & dados numéricos , Japão/epidemiologia , Masculino , Pontuação de Propensão , Estudos Retrospectivos , Convulsões/epidemiologia , Tromboembolia/induzido quimicamente , Tromboembolia/epidemiologia , Ferimentos e Lesões/epidemiologia
15.
J Cardiothorac Vasc Anesth ; 32(4): 1627-1634, 2018 08.
Artigo em Inglês | MEDLINE | ID: mdl-29174746

RESUMO

OBJECTIVES: The authors stopped using tranexamic acid (TXA) in April 2013. The present study aimed to examine the impact of a "no-TXA-use" policy by comparing the adverse effects of TXA and clinical outcomes before and after the policy change in patients undergoing cardiovascular surgery. DESIGN: A single center retrospective cohort study. SETTING: A single cardiovascular center. PARTICIPANTS: Patients undergoing cardiovascular surgery between January 2008 and July 2015 (n = 3,535). INTERVENTIONS: Patients' outcomes before and after the policy change were compared to evaluate the effects of the change. MEASUREMENTS AND MAIN RESULTS: The seizure rate decreased significantly after the policy change (6.9% v 2.7%, p < 0.001). However, transfusion volumes and blood loss volumes increased significantly after the policy change (1,840 mL v 2,030 mL, p = 0.001; 1,250 mL v 1,372 mL, p < 0.001, respectively). Thirty-day mortality was not statistically different (1.6% v 1.4%, p = 0.82), nor were any of the other outcomes. Propensity-matched analysis and segmented regression analysis showed similar results. CONCLUSIONS: The mortality rate remained the same even though the seizure rate decreased after the policy change. Blood loss volume and transfusion volume both increased after the policy change. TXA use provides an advantageous benefit by reducing the need for blood transfusion.


Assuntos
Antifibrinolíticos/efeitos adversos , Perda Sanguínea Cirúrgica/mortalidade , Procedimentos Cirúrgicos Cardiovasculares/efeitos adversos , Procedimentos Cirúrgicos Cardiovasculares/mortalidade , Ácido Tranexâmico/efeitos adversos , Idoso , Procedimentos Cirúrgicos Cardiovasculares/tendências , Estudos de Coortes , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Mortalidade/tendências , Estudos Retrospectivos
16.
J Artif Organs ; 21(4): 462-465, 2018 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-29938391

RESUMO

Treating a patient with heparin-induced thrombocytopenia can be challenging particularly when the patient requires urgent cardiac surgery that uses heparin for anticoagulation. We herein report a case of a 61-year-old man with idiopathic dilated cardiomyopathy associated with heparin-induced thrombocytopenia and who underwent plasma exchange to remove heparin-induced thrombocytopenia antibodies before undergoing left ventricular assist device implantation. The surgery was performed using cardiopulmonary bypass and unfractionated heparin.


Assuntos
Insuficiência Cardíaca/cirurgia , Coração Auxiliar , Heparina/efeitos adversos , Troca Plasmática/métodos , Trombocitopenia/terapia , Anticoagulantes/efeitos adversos , Insuficiência Cardíaca/complicações , Humanos , Masculino , Pessoa de Meia-Idade , Trombocitopenia/induzido quimicamente , Trombocitopenia/complicações
17.
J Anesth ; 32(3): 387-393, 2018 06.
Artigo em Inglês | MEDLINE | ID: mdl-29616345

RESUMO

PURPOSE: The fourth-generation FloTrac/Vigileo™ improved its algorithm to follow changes in systemic vascular resistance index (SVRI). This revision may improve the accuracy and trending ability of CI even in patients who undergo abdominal aortic aneurysm (AAA) surgery which cause drastic change of SVRI by aortic clamping. The purpose of this study is to elucidate the accuracy and trending ability of the fourth-generation FloTrac/Vigileo™ in patients with AAA surgery by comparing the FloTrac/Vigileo™-derived CI (CIFT) with that measured by three-dimensional echocardiography (CI3D). METHODS: Twenty-six patients undergoing elective AAA surgery were included in this study. CIFT and CI3D were determined simultaneously in eight points including before and after aortic clamp. We used CI3D as the reference method. RESULTS: In the Bland-Altman analysis, CIFT had a wide limit of agreement with CI3D showing a percentage error of 46.7%. Subgroup analysis showed that the percentage error between CO3D and COFT was 56.3% in patients with cardiac index < 2.5 L/min/m2 and 28.4% in patients with cardiac index ≥ 2.5 L/min/m2. SVRI was significantly higher in patients with cardiac index < 2.5 L/min/m2 (1703 ± 330 vs. 2757 ± 798; p < 0.001). The tracking ability of fourth generation of FloTrac/Vigileo™ after aortic clamp was not clinically acceptable (26.9%). CONCLUSIONS: The degree of accuracy of the fourth-generation FloTrac/Vigileo™ in patients with AAA surgery was not acceptable. The tracking ability of the fourth-generation FloTrac/Vigileo™ after aortic clamp was below the acceptable limit.


Assuntos
Aneurisma da Aorta Abdominal/cirurgia , Ecocardiografia Tridimensional/métodos , Ecocardiografia Transesofagiana/métodos , Monitorização Intraoperatória/métodos , Idoso , Idoso de 80 Anos ou mais , Anestesia Geral/métodos , Débito Cardíaco , Cateterismo , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos , Artéria Radial , Reprodutibilidade dos Testes
18.
J Anesth ; 32(4): 539-546, 2018 08.
Artigo em Inglês | MEDLINE | ID: mdl-29789931

RESUMO

PURPOSE: The aim of this study was to examine the relationship between FFP (fresh frozen plasma)/pRBC (packed red blood cell) transfusion ratio and outcomes in patients undergoing cardiovascular surgery. METHODS: This is a single center retrospective cohort study performed in a cardiovascular center. Patients undergoing cardiovascular surgery between January 2012 and October 2016 with or without massive transfusion (n = 1453). Patients' outcomes were compared based on FFP/pRBC transfusion ratio (FFP/pRBC > 1 or FFP/pRBC ≤ 1). RESULTS: In hospital mortality and rate of stroke and myocardial infarction was significantly higher in patients with less than 1 of FFP/pRBC transfusion ratio only in patients with massive transfusion (3.0 vs 8.8%, p = 0.001; 0.7 vs 6.4%, p < 0.001; 1.0 vs 3.2%, p = 0.047, respectively). CONCLUSIONS: Higher FFP/RBC ratio was associated with reduced risk of death, stroke and myocardial infarction only in patients with cardiovascular surgery receiving massive transfusion. Clinicians should be aware that judicious FFP replacement plays a critical role in the successful management of massive transfusion in cardiac surgery.


Assuntos
Transfusão de Sangue/métodos , Procedimentos Cirúrgicos Cardíacos/métodos , Transfusão de Eritrócitos , Plasma , Idoso , Procedimentos Cirúrgicos Cardíacos/mortalidade , Estudos de Coortes , Feminino , Mortalidade Hospitalar , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Retrospectivos
19.
J Cardiothorac Vasc Anesth ; 31(2): 549-553, 2017 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-27988092

RESUMO

OBJECTIVES: The present study aimed to examine the association between tranexamic acid (TXA) use and adverse effects (seizures, thromboembolism, and renal dysfunction) in a pediatric cardiac surgery population using a national inpatient database in Japan. The authors also assessed the association between TXA use and other clinical outcomes (length of hospital stay and in-hospital mortality). DESIGN: A nationwide, retrospective cohort study using propensity score analyses. SETTING: Japanese Diagnosis Procedure Combination inpatient database. PARTICIPANTS: Pediatric patients who underwent cardiac surgery using cardiopulmonary bypass between July 2010 and March 2014 (N = 11,275). INTERVENTIONS: None. MEASUREMENTS AND MAIN RESULTS: Propensity-score matching created 3,739 pairs of patients with and without TXA administration. Propensity-matched analysis showed that the proportion of seizures was significantly higher in the TXA group than in the non-TXA group (1.6% v 0.2%, difference, 1.4%; 95% confidence interval, 1.0-1.9; p<0.001). However, none of the other outcomes was significantly different between the groups. CONCLUSIONS: TXA use is associated with a significantly increased risk of seizures. However, there is no difference in any other outcomes between the TXA and non-TXA groups.


Assuntos
Antifibrinolíticos/efeitos adversos , Procedimentos Cirúrgicos Cardíacos , Bases de Dados Factuais , Convulsões/induzido quimicamente , Ácido Tranexâmico/efeitos adversos , Antifibrinolíticos/uso terapêutico , Procedimentos Cirúrgicos Cardíacos/tendências , Pré-Escolar , Estudos de Coortes , Bases de Dados Factuais/tendências , Feminino , Humanos , Lactente , Recém-Nascido , Japão/epidemiologia , Masculino , Pontuação de Propensão , Estudos Retrospectivos , Convulsões/epidemiologia , Ácido Tranexâmico/uso terapêutico
20.
J Cardiothorac Vasc Anesth ; 31(1): 99-104, 2017 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-27612931

RESUMO

OBJECTIVES: To determine the accuracy and trending ability of the fourth-generation FloTrac/Vigileo in patients with low cardiac index by comparing FloTrac/Vigileo-derived cardiac index with that measured by 3-dimensional echocardiography. DESIGN: Prospective clinical study. SETTING: Cardiac surgery operating room in a single cardiovascular center. PARTICIPANTS: Twenty-five patients undergoing elective cardiac resynchronization therapy lead implantation. INTERVENTIONS: FloTrac/Vigileo-derived cardiac index and 3-dimensional echocardiography-derived cardiac index were determined simultaneously before and after phenylephrine bolus and cardiac resynchronization therapy using 3-dimensional echocardiography-derived cardiac index as the reference method. MEASUREMENTS AND MAIN RESULTS: Cardiac index measured by the fourth-generation FloTrac/Vigileo had a wide limit of agreement with that measured by 3-dimensional echocardiography, with a percentage error of 59.1%. The tracking ability of the unit after both phenylephrine administration and cardiac resynchronization therapy were measured by concordance rate, and both were below the acceptable limit (72.7% and 85%, respectively). CONCLUSIONS: The degree of accuracy of the fourth-generation FloTrac/Vigileo in patients with low cardiac index was not acceptable, and high systemic vascular resistance in patients with low cardiac index may have contributed to this inaccuracy. The tracking ability of the fourth-generation FloTrac/Vigileo after phenylephrine administration or cardiac resynchronization therapy was below acceptable limits.


Assuntos
Terapia de Ressincronização Cardíaca/métodos , Monitorização Intraoperatória/métodos , Adulto , Idoso , Idoso de 80 Anos ou mais , Anestesia Geral/métodos , Débito Cardíaco/efeitos dos fármacos , Débito Cardíaco/fisiologia , Dispositivos de Terapia de Ressincronização Cardíaca , Ecocardiografia Tridimensional/métodos , Feminino , Insuficiência Cardíaca/terapia , Hemodinâmica/fisiologia , Humanos , Masculino , Pessoa de Meia-Idade , Monitorização Intraoperatória/instrumentação , Monitorização Intraoperatória/normas , Variações Dependentes do Observador , Fenilefrina/farmacologia , Estudos Prospectivos , Implantação de Prótese/métodos , Reprodutibilidade dos Testes , Termodiluição/métodos , Vasoconstritores/farmacologia , Adulto Jovem
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA