Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 11 de 11
Filtrar
1.
J Surg Res ; 261: 51-57, 2021 05.
Artigo em Inglês | MEDLINE | ID: mdl-33412509

RESUMO

BACKGROUND: Intraoperative ultrasonography is the golden standard method for evaluation of liver tumors during hepatectomy. However, in laparoscopic surgery, accurate assessment of tumors may be difficult, particularly if the lesion is located nearby the liver surface because of the challenges in handling the intraoperative ultrasound and the lack of tactile sensation. In this study, we demonstrate the preliminary results of examining the microvascular architecture of subcapsular hepatic tumors using laparoscopic narrow-band imaging (NBI) to distinguish between malignant and benign tumors. MATERIALS AND METHODS: Thirty-five lesions were examined by NBI during laparoscopic hepatectomy for the presence of abnormal microvasculature on the liver surface in relation to hepatic tumors from January 2016 to August 2018. The microvascular findings were correlated with tumor localization and pathological diagnosis. RESULTS: The 35 examined nodules included 11 hepatocellular carcinoma, 18 colorectal liver metastasis, and six benign nodules. The mean tumor diameter was 26.3 (3-70) mm, and the distance from the liver surface to the tumor was 0.5 (0-5) mm. Microvessels on the liver surface were clearly visualized by NBI, consistent with malignant tumor localization. The tumors were thoroughly examined for the presence of three pathological microvascular features (enlargement, tortuosity, and heterogeneity). Abnormal microvascular patterns were found in 90.9% of hepatocellular carcinoma and 77.8% of colorectal liver metastasis, whereas neither normal sites nor benign lesions displayed microvascular abnormality. CONCLUSIONS: This study suggests that observing the microvessel image on the liver surface by NBI could be useful in tumor localization and differentiation between benign and malignant lesions.


Assuntos
Carcinoma Hepatocelular/diagnóstico por imagem , Neoplasias Hepáticas/diagnóstico por imagem , Fígado/diagnóstico por imagem , Microvasos/diagnóstico por imagem , Imagem de Banda Estreita , Adulto , Idoso , Idoso de 80 Anos ou mais , Carcinoma Hepatocelular/irrigação sanguínea , Neoplasias Colorretais/patologia , Feminino , Humanos , Fígado/patologia , Neoplasias Hepáticas/irrigação sanguínea , Neoplasias Hepáticas/secundário , Masculino , Microvasos/patologia , Pessoa de Meia-Idade , Neovascularização Patológica/diagnóstico por imagem , Estudos Retrospectivos
2.
Langenbecks Arch Surg ; 405(3): 381-389, 2020 May.
Artigo em Inglês | MEDLINE | ID: mdl-32410077

RESUMO

PURPOSE: Three-dimensional virtual endoscopy (3DVE) has the potential advantage of enhanced anatomic delineation and spatial orientation during laparoscopic procedures. In the present study, we aimed to evaluate the impact of 3DVE guidance in laparoscopic distal pancreatectomy (LDP). METHODS: Thirty-eight patients presenting to our hospital with a variety of pancreatic tumors underwent preoperative computed tomography scanning to clearly define the major peripancreatic vasculature and correlate it with a 3DVE system (SYNAPSE VINCENT: Fujifilm Medical, Tokyo, Japan). This map served as the guide during preoperative planning, surgical education, and simulation and as intraoperative navigation reference for LDP. Operative records and pathological findings were analyzed for each procedure. Operative parameters were compared between the 38 patients in this study and 8 patients performed without 3DVE guidance at our institution. RESULTS: The 3DVE navigation system successfully created a preoperative resection map in all patients. Relevant peripancreatic vasculature displayed on the system was identified and compared during the intervention. The mean blood loss in LDP performed under 3DVE guidance versus LDP without 3DVE was 168.5 +/- 347.6 g versus 330.0 +/- 211.4 g, p = 0.008 while and the operative time was 171.9 +/- 51.7 min versus 240.6 +/- 24.8 min, p = 0.001. CONCLUSIONS: 3DVE in conjunction with a "laparoscopic eye" creates a preoperative and intraoperative three-dimensional data platform that potentially enhances the accuracy and safety of LDP.


Assuntos
Imageamento Tridimensional , Laparoscopia/métodos , Pancreatectomia/métodos , Neoplasias Pancreáticas/cirurgia , Cirurgia Assistida por Computador/métodos , Realidade Virtual , Idoso , Idoso de 80 Anos ou mais , Estudos de Coortes , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Neoplasias Pancreáticas/diagnóstico por imagem , Neoplasias Pancreáticas/patologia , Tomografia Computadorizada por Raios X
3.
BMC Surg ; 20(1): 223, 2020 Oct 06.
Artigo em Inglês | MEDLINE | ID: mdl-33023558

RESUMO

BACKGROUND: Pancreatic fistula is one of the serious complications for patients undergoing distal pancreatectomy, which leads to significant morbidity. The aim of our study is to compare linear stapling closure plus continuous suture with linear stapling closure alone during laparoscopic distal pancreatectomy (LDP) in terms of clinically relevant postoperative pancreatic fistula (POPF) rate. METHODS: Twenty-two patients underwent LDP at our institution between 2011 and 2013. Twelve patients had linear stapling closure with peri-firing compression (LSC) alone compared with ten patients who had linear stapling closure, peri-firing compression plus continuous suture (LSC/CS) for stump closure of remnant pancreas in LDP. Biochemical leak and clinically relevant POPF were compared between both groups. RESULTS: POPF occurred in 4 of 12 (33.3%) patients with linear stapling closure while no patient developed a clinically relevant POPF in the triple combination of linear stapling, peri-firing compression plus continuous suture group (p = 0.043).1 patient (8.3%) in the LSC group and 5 patients (50%) in the LSC/CS group had evidence of a biochemical leak. There were no significant differences in operative time (188.3 vs 187.0 min) and blood loss (135 vs. 240 g) between both groups but there was a significantly of shorter length of hospital stay (11.9 vs. 19.9 days) in LSC/CS group (p = 0.037). There was no mortality in either group. CONCLUSIONS: The triple combination of linear stapling, peri-firing compression plus continuous suture in LDP has effectively prevented occurrence of clinically relevant ISGPF POPF. TRIAL REGISTRATION: The study was retrospectively registered September 30, 2019 at Showa University Ethics Committee as IRB protocol numbers 2943.


Assuntos
Laparoscopia , Pancreatectomia , Fístula Pancreática , Idoso , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Pâncreas/cirurgia , Pancreatectomia/efeitos adversos , Fístula Pancreática/etiologia , Fístula Pancreática/prevenção & controle , Complicações Pós-Operatórias , Grampeamento Cirúrgico , Técnicas de Sutura , Suturas
4.
Aquat Toxicol ; 249: 106238, 2022 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-35863252

RESUMO

Silica nanoparticles (SiNPs) are among the non-toxic nanoparticles (NPs) that have magnetic capabilities. It is hypothesized that SiNPs may be able to reduce toxic effects exerted by a mixture of lead (Pb) and mercury (Hg) in African catfish Clarias gariepinus. The in vitro magnetic potential of SiNPs to absorb Pb and Hg was tested. Fish (N = 240) were divided into four groups in triplicates for 30 days. The first group served as control and the second group (SiNPs) was exposed to 1/10 of 96 h LC50 of SiNPs (14.45 mg/L). The third group (HMM) was exposed to 1/10 of 96-h LC50 of a mixture of mercury chloride (HgCl2) and lead chloride (PbCl2) equal to 0.04 mg/ L and 23.1 mg/L. The fourth group (SiNPs+ HMM) was exposed to a suspension composed of SiNPs, HgCl2, and PbCl2 at the same concentrations as the third group. Results showed that fish exposed to heavy metals revealed the following consequences; a significant decrease in hematological, immunological (complement-3 and nitric oxide), and antioxidants (total antioxidant capacity, glutathione peroxidase, superoxide dismutase, and catalase) indices, down-regulation of IL-1ß, IL-8, TGF-ß, NF-κß, HSP70, and Hepcidin genes, the highest mortality rate (48.33%), higher values of alkaline phosphatase, alanine, and aspartate aminotransferases, urea, creatinine, and branchial malondialdehyde, marked up-regulation of CC chemokine and CXC chemokines, and high HMs residues levels in muscles. Extensive pathology showed degeneration with diffuse vacuolation of hepatopancreatic cells and hemorrhage in the HMM group. Interestingly, the exposed group to SiNPs and HMM demonstrated a decline of HMs concentration in fish muscles and modulated the abovementioned parameters with the regeneration of histological alterations of liver and gills. Based on the study outcomes, we highlight the importance and the safety of SiNPs as a novel aqueous additive to alleviate HMs toxicity and recommend using SiNPs for enhancing fish performance for sustaining aquaculture without adverting safety of human health by their little accumulation in muscular tissue.


Assuntos
Peixes-Gato , Mercúrio , Metais Pesados , Nanopartículas , Poluentes Químicos da Água , Animais , Antioxidantes/metabolismo , Peixes-Gato/metabolismo , Humanos , Chumbo , Metais Pesados/toxicidade , Nanopartículas/toxicidade , Estresse Oxidativo , Dióxido de Silício/toxicidade , Poluentes Químicos da Água/toxicidade
5.
Anticancer Res ; 42(1): 67-73, 2022 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-34969710

RESUMO

BACKGROUND: Probe-based confocal laser endomicroscopy (pCLE) can visualize microscopic structures at high resolution but has not yet yielded definitive diagnostic features of gallbladder malignancy, as opposed to benign changes. PATIENTS AND METHODS: A total of 73 patients had their gallbladder evaluated with pCLE performed on resected benign and malignant gallbladder surgical specimens, which were sprayed with fluorescein. Malignant and benign features of pCLE findings were identified on the basis of Miami and Paris Classifications. Standard histopathological diagnoses and individual patient pCLE findings of gallbladder lesions were correlated. RESULTS: Of the 73 consecutive patients that had their gallbladder evaluated ex vivo with pCLE, 11 were identified with gallbladder malignancy. pCLE identified features of gallbladders examined ex vivo, including the presence of thick dark bands and dark clumps, which together correlated with histopathologically-determined biliary malignancy at 100% sensitivity. Thick white bands and visualized epithelium, also identified with pCLE, together correlated with histopathologically-determined malignancy at 100% specificity. CONCLUSION: pCLE can be used for real-time differentiation of cancerous/non-cancerous regions in the gallbladder using the diagnostic criteria identified in the present study.


Assuntos
Endoscopia/métodos , Neoplasias da Vesícula Biliar/diagnóstico , Microscopia Confocal/métodos , Feminino , Humanos , Masculino
6.
Life (Basel) ; 12(10)2022 Sep 27.
Artigo em Inglês | MEDLINE | ID: mdl-36294935

RESUMO

Chlorpyrifos (CPF) is a common organophosphorus insecticide. It is associated with negative consequences such as neurotoxicity and reproductive injury. This study aimed to observe the ability of olive leaf extract to attenuate chlorpyrifos toxicity, which induced neuro- and reproductive toxicity in male albino rats. Olive leaf extract (OLE) exhibits potent antioxidant and antiapoptotic properties. Twenty-two mature male rats were divided into four groups: control (saline), CPF (9 mg/kg), OLE (150 mg/kg), and CPF + OLE. Treatment was administered orally for 80 days. The CPF significantly reduced serum sex hormones, sperm counts and motility, high oxidants (MDA), and depleted antioxidants (GSH, SOD, TAC) in the brain and testes homogenate; additionally, it decreased serum AChE and brain neurotransmitters, increased Bax, decreased Bcl-2, and boosted caspase-3 immune expression in neural and testicular cells. Immunological expression of Ki 67 in the cerebrum, cerebellum, choroid plexus, and hippocampus was reduced, and α-SMA in testicular tissue also decreased. Histopathological findings were consistent with the above impacts. OLE co-administration significantly normalized all these abnormalities. OLE showed significant protection against neural and reproductive damage caused by CPF.

7.
Eur J Trauma Emerg Surg ; 47(5): 1553-1559, 2021 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-32065243

RESUMO

PURPOSE: This study evaluates the accuracy of IV contrast-enhanced computed tomography (CT) tractography in the detection of peritoneal violation in anterior abdominal stab wounds (AASW) and its impact on the management algorithm. METHODS: This prospective study included 61 patients who presented to Kasr Alainy Hospital with AASW. According to the IV contrast-enhanced CT tractography, they were classified into penetrating, equivocal and non-penetrating injuries. The former two were subjected to diagnostic laparoscopy (DL), while the non-penetrating group was subjected to serial abdominal examination (SAE). The accuracy of CT tractography to detect peritoneal violation was assessed by correlating its findings with management outcome. RESULTS: CT tractography stratified the injuries into non penetrating (54.1%), equivocal (14.8%) and penetrating (31.1%). All non-penetrating stabs were managed successfully by SAE. DL proved negative for peritoneal violation in all equivocal injuries and positive in all injuries designated as penetrating. Consequently, sensitivity, specificity, positive and negative predictive values and accuracy of CT tractography in detecting peritoneal violation was 100%. No missed injuries were encountered in this study. CONCLUSION: IV contrast-enhanced CT tractography is an effective tool in the evaluation of patients with AASW. Patients with negative tractography can be safely managed by SAE. Positive tractography accurately indicates peritoneal violation which warrants further management. Patients with equivocal findings were all negative for peritoneal violation by laparoscopy, therefore, they might be reallocated for frequent SAE to reduce the rate of non-therapeutic interventions.


Assuntos
Traumatismos Abdominais , Ferimentos Penetrantes , Ferimentos Perfurantes , Traumatismos Abdominais/diagnóstico por imagem , Traumatismos Abdominais/cirurgia , Algoritmos , Humanos , Laparotomia , Estudos Prospectivos , Tomografia Computadorizada por Raios X , Ferimentos Perfurantes/diagnóstico por imagem , Ferimentos Perfurantes/cirurgia
8.
J Gastrointest Surg ; 25(7): 1779-1786, 2021 07.
Artigo em Inglês | MEDLINE | ID: mdl-32901425

RESUMO

BACKGROUND: Recently, virtual navigation system has been applied to hepatic surgery, enabling better visualization of intrahepatic vascular branches and location of tumor. Intraoperative ultrasonography (IOUS) is the most common form of image guidance during liver surgery. However, during laparoscopic hepatectomies (LH), IOUS has several limitations and its reliability has been poorly evaluated. The objective of this work is to evaluate VRCT (virtual real-time CT-guided volume navigation) during LH. This system aims to provide accurate anatomical orientation for surgeons enhancing the safety of LH. METHODS: Twenty-seven hepatic neoplasms were resected laparoscopically at our institution under reference guidance of VRCT. During operation, electromagnetic tracking of the surgical instrument was used for navigating the direction of accurate liver transection. RESULTS: Twenty-six (96.3%) of the 27 lesions (mean diameter 11 mm) were successfully performed under VRCT guidance. Average registration time was < 2 min. Average setup time was approximately 7 min per procedure. VRCT allows the surgeon to navigate liver transection with acceptable accuracy. The mean error was 12 mm. All surgical margins were negative and the mean histologic resection margin was 9 mm. CONCLUSIONS: VRCT-guided LH is feasible and provides valuable real-time anatomical feedback during hepatic resections. Advancement of such systems to improve accuracy might greatly compensate for the limitation of laparoscopic IOUS.


Assuntos
Laparoscopia , Neoplasias Hepáticas , Cirurgia Assistida por Computador , Hepatectomia , Humanos , Fígado/diagnóstico por imagem , Fígado/cirurgia , Neoplasias Hepáticas/diagnóstico por imagem , Neoplasias Hepáticas/cirurgia , Reprodutibilidade dos Testes , Tomografia Computadorizada por Raios X
9.
Egypt Liver J ; 11(1): 92, 2021.
Artigo em Inglês | MEDLINE | ID: mdl-34956680

RESUMO

BACKGROUND: Solid organ transplantation (SOT) service has been disrupted during the current coronavirus disease 2019 (COVID-19) pandemic, which deferred the service in most centers worldwide. As the pandemic persists, there will be an urgency to identify the best and safest practices for resuming activities as areas re-open. Resuming activity is a difficult issue, in particular, the decision of reopening after a period of slowing down or complete cessation of activities. OBJECTIVES: To share our experience in resuming living donor liver transplantation (LDLT) in the context of the COVID-19 pandemic in the Liver Transplantation Unit of El-Manial Specialized Hospital, Cairo University, Egypt, and to review the obstacles that we have faced. MATERIAL AND METHODS: This study is a single-center study. We resumed LDLT by the 26th of August 2020 after a period of closure from the 1st of March 2020. We have taken a lot of steps in order to prevent COVID-19 transmission among transplant patients and healthcare workers (HCWs). RESULTS: In our study, we reported three LDLT recipients, once resuming the transplantation till now. All our recipients and donors tested negative for SARS-CoV-2 by nasopharyngeal RT-PCR a day before the transplantation. Unfortunately, one of them developed COVID-19 infection. We managed rapidly to isolate him in a single room, restricting one team of HCWs to deal with him with strict personal protective measures. Finally, the patient improved and was discharged in a good condition. The second patient ran a smooth course apart from FK neurotoxicity which improved with proper management. The third patient experienced a sharp rise in bilirubin and transaminases on day 14 that was attributed to drug toxicity vs. rejection and managed by discontinuing the offending drugs and pulse steroids. In addition, one of our head nurses tested positive for SARS-CoV-2 that was manageable with self-isolation. CONCLUSION: Careful patient, donor, personnel screening is mandatory. Adequate supply of personal protective equipments, effective infection control policies, and appropriate administrative modifications are needed for a safe return of LDLT practice.

10.
Exp Clin Transplant ; 15(6): 648-657, 2017 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-29025382

RESUMO

OBJECTIVES: Biliary complications are common after living-donor liver transplant. This retrospective study reviewed our experience with biliary complications in recipients of living-donor liver transplant. MATERIALS AND METHODS: Over our 9-year study period, 120 patients underwent living-donor liver transplant. Patients were divided into 2 groups, with group A having biliary complications and group B without biliary complications. Both groups were compared, and different treatment modalities for biliary complications were evaluated. RESULTS: Group A included 45 patients (37.5%), whereas group B included 75 patients (62.5%). Biliary complications included bile leak in 17 patients (14.2%), biliary stricture in 11 patients (9.2%), combined biliary stricture with bile leak in 15 patients (12.5%), and sphincter of Oddi dysfunction and cholangitis in 1 patient each (0.8%). Cold ischemia time was significantly longer in group A (P = .002). External biliary drainage was less frequently used in group A (P = .031). Technical success rates of endoscopic biliary drainage and percutaneous transhepatic biliary drainage were 68.3% and 41.7%. Survival rate following relaparotomy for biliary complications was 62.5%. CONCLUSIONS: Graft ischemia is an important risk factor for biliary complications. Bile leaks can predispose to anastomotic strictures. The use of external biliary drainage seems to reduce the incidence of biliary complications. Endoscopic and percutaneous trans-hepatic approaches can successfully treat more than two-thirds of biliary complications. Relaparotomy can improve survival outcomes and is usually reserved for patients with intractable biliary complications.


Assuntos
Fístula Anastomótica/etiologia , Procedimentos Cirúrgicos do Sistema Biliar/efeitos adversos , Colangite/etiologia , Colestase/etiologia , Transplante de Fígado/efeitos adversos , Doadores Vivos , Disfunção do Esfíncter da Ampola Hepatopancreática/etiologia , Adolescente , Adulto , Idoso , Fístula Anastomótica/diagnóstico por imagem , Fístula Anastomótica/mortalidade , Fístula Anastomótica/terapia , Procedimentos Cirúrgicos do Sistema Biliar/métodos , Procedimentos Cirúrgicos do Sistema Biliar/mortalidade , Criança , Pré-Escolar , Colangiopancreatografia Retrógrada Endoscópica , Colangite/diagnóstico por imagem , Colangite/mortalidade , Colangite/terapia , Colestase/diagnóstico por imagem , Colestase/mortalidade , Colestase/terapia , Isquemia Fria/efeitos adversos , Drenagem/métodos , Egito , Feminino , Humanos , Lactente , Transplante de Fígado/métodos , Transplante de Fígado/mortalidade , Masculino , Pessoa de Meia-Idade , Reoperação , Estudos Retrospectivos , Fatores de Risco , Disfunção do Esfíncter da Ampola Hepatopancreática/diagnóstico por imagem , Disfunção do Esfíncter da Ampola Hepatopancreática/mortalidade , Disfunção do Esfíncter da Ampola Hepatopancreática/terapia , Fatores de Tempo , Resultado do Tratamento , Adulto Jovem
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA