Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 8 de 8
Filtrar
1.
J Nucl Med Technol ; 36(2): 82-7, 2008 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-18483139

RESUMO

UNLABELLED: We evaluated different (57)Co flood source activities and acquisition times to obtain an optimal localization image for breast lymphoscintigraphy that would adequately outline the body and allow detection of nodes seen on the emission scan while minimizing unnecessary radiation exposure to the patient. METHODS: An anthropomorphic thorax breast phantom representing an average-size patient was used to simulate nodes on a breast lymphoscintigraphy scan. The activities in the nodes at the time of acquisition ranged from 37 to 185 kBq (1-5 microCi). Four experiments were performed, consisting of 10-min emission and 3-min localization images. Anterior, posterior, and right and left lateral views of the thorax phantom were acquired, using each of 5 different (57)Co flood sources with activities ranging from 37 to 269 MBq (1.0-7.26 mCi). Ten 1-min localization images for each source were acquired and compared for quality. Three-minute localization images for 2 phantom thicknesses of 10 and 20 cm were acquired to determine the contrast-to-noise ratio for each (57)Co source. The total exposure was measured using an ion chamber survey meter. RESULTS: All sources allowed visualization of the lymphatic nodes in acquisitions as short as 3 min. Images using the 126-MBq (3.41-mCi) source demonstrated an adequate body outline along with visualization of all nodes seen on the emission image. The 37-MBq (1.0-mCi) source did not provide sufficient definition of the body outline, whereas the hotter sources decreased node visualization by increasing the background around the nodes at the same time that they increased the patient exposure. Node activity of 37 kBq (1 microCi) became undetectable on the anterior localization images yet was still visible on the lateral image because of greater attenuation of (57)Co photons. The estimated dose rate from the (57)Co sheet sources was 0.641 microSv/MBq/h. CONCLUSION: Acquiring a 3-min localization scan using a 126-MBq (3.41-mCi) source provided the best combination of clear-body outline and visualization of all nodes seen on the emission image. The estimated dose to the patient from the 126-MBq (3.41-mCi) sheet source was very low (8.7 microSv for unilateral and 13.1 microSv for bilateral). Node detectability decreased in localization images acquired using (57)Co sources of higher activity. This effect would be more pronounced in lymphoscintigrams of thin patients compared with those of patients of average thickness.


Assuntos
Neoplasias da Mama/diagnóstico por imagem , Radioisótopos de Cobalto/administração & dosagem , Aumento da Imagem/métodos , Linfonodos/diagnóstico por imagem , Feminino , Humanos , Injeções/métodos , Metástase Linfática , Cintilografia , Compostos Radiofarmacêuticos/administração & dosagem , Reprodutibilidade dos Testes , Sensibilidade e Especificidade
2.
J Nucl Med Technol ; 35(1): 10-6; quiz 17-20, 2007 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-17337652

RESUMO

In patients with head and neck tumors, preoperative lymphoscintigraphy can be used to map lymphatic drainage patterns and identify sentinel lymph nodes. However, it is very difficult to determine the exact locations of head and neck sentinel nodes on preoperative lymphoscintigraphy without the use of anatomic landmarks. Lymph nodes in the head and neck are grouped into 7 regions, or levels, on the basis of anatomic landmarks. In patients undergoing standard lymphoscintigraphy, obtaining lateral marker images that show important anatomic landmarks can help with the localization of sentinel nodes. However, technical problems often render marker images of little or no use. Hybrid SPECT/CT lymphoscintigraphic imaging facilitates the localization of sentinel nodes by reliably showing the relationships between sentinel nodes and important anatomic structures. After reading this article, the reader should understand the lymph node level classification system for head and neck melanomas, be able to describe the technique used for the imaging of sentinel nodes in the head and neck region, and be able to demonstrate how SPECT/CT lymphoscintigraphic imaging can enable precise sentinel node localization and thus help to ensure minimal dissection.


Assuntos
Neoplasias de Cabeça e Pescoço/diagnóstico , Linfonodos/diagnóstico por imagem , Melanoma/diagnóstico , Melanoma/secundário , Tomografia Computadorizada de Emissão de Fóton Único/métodos , Tomografia Computadorizada por Raios X/métodos , Humanos , Aumento da Imagem/métodos , Linfonodos/patologia , Metástase Linfática , Guias de Prática Clínica como Assunto , Biópsia de Linfonodo Sentinela/métodos
3.
Nucl Med Commun ; 38(1): 35-43, 2017 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-27775993

RESUMO

OBJECTIVE: The aim of this study was to assess the feasibility of IQ-SPECT gated blood pool (MUGA) under conditions of decreased scan time (ST). PATIENTS AND METHODS: Ten patients underwent routine 26-min, two-view planar, followed by LEHR and IQ-SPECT MUGA, on a Siemens dual-head Symbia scanner. Six 'back and forth' 4-min SPECT scans were summed into 4-, 8-, 12-, 16-, 20-, and 24-min equivalent scans, and reconstructed iteratively (IQ-SPECT and LEHR) and with FBP (LEHR). Uniformity, contrast, and wall motion were scored on a five-point scale. Linear regressions of left ventricular (LV) ejection fraction (EF) were performed between FBP, Flash 3D, and IQ-SPECT versus planar and Flash 3D and IQ-SPECT versus FBP. Agreement tables between Flash 3D and IQ-SPECT versus FBP LV EF were generated using a normal versus cardiotoxicity threshold of 50%. RESULTS: IQ-SPECT had the best scores for all STs, and 4, 8, and 16 min IQ-SPECT were judged to be similar to 24-min LEHR FBP, Flash 3D, and planar, respectively. The average LV EF correlation coefficients were 0.69, 0.71, and 0.63 between IQ-SPECT, Flash 3D, and FBP versus planar, respectively; 0.70 between IQ-SPECT and FBP; and 0.88 between Flash 3D and FBP, and all were statistically significant (P<0.05), except for 16-min FBP LEHR versus planar. Agreement tables showed diagnostic equivalence of IQ-SPECT, Flash 3D, and FBP. CONCLUSION: These preliminary results suggest that IQ-SPECT is equivalent to LEHR Flash 3D and FBP for MUGA SPECT, and better at reduced ST. A larger patient population study is necessary for a more definitive assessment.


Assuntos
Tomografia Computadorizada por Emissão de Fóton Único de Sincronização Cardíaca/métodos , Imagem do Acúmulo Cardíaco de Comporta/métodos , Tomografia Computadorizada por Emissão de Fóton Único de Sincronização Cardíaca/estatística & dados numéricos , Estudos de Viabilidade , Imagem do Acúmulo Cardíaco de Comporta/estatística & dados numéricos , Humanos , Imageamento Tridimensional/métodos , Imageamento Tridimensional/estatística & dados numéricos , Fatores de Tempo
4.
Med Phys ; 33(10): 3931-8, 2006 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-17089855

RESUMO

We proposed a low-dose average computer tomography (ACT) for attenuation correction (AC) of the PET cardiac data in PET/CT. The ACT was obtained from a cine CT scan of over one breath cycle per couch position while the patient was free breathing. We applied this technique on four patients who underwent tumor imaging with 18F-FDG in PET/CT, whose PET data showed high uptake of 18F-FDG in the heart and whose CT and PET data had misregistration. All four patients did not have known myocardiac infarction or ischemia. The patients were injected with 555-740 MBq of 18F-FDG and scanned 1 h after injection. The helical CT (HCT) data were acquired in 16 s for the coverage of 100 cm. The PET acquisition was 3 min per bed of 15 cm. The duration of cine CT acquisition per 2 cm was 5.9 s. We used a fast gantry rotation cycle time of 0.5 s to minimize motion induced reconstruction artifacts in the cine CT images, which were averaged to become the ACT images for AC of the PET data. The radiation dose was about 5 mGy for 5.9 s cine duration. The selection of 5.9 s was based on our analysis of the respiratory signals of 600 patients; 87% of the patients had average breath cycles of less than 6 s and 90% had standard deviations of less than 1 s in the period of breath cycle. In all four patient studies, registrations between the CT and the PET data were improved. An increase of average uptake in the anterior and the lateral walls up to 48% and a decrease of average uptake in the septal and the inferior walls up to 16% with ACT were observed. We also compared ACT and conventional slow scan CT (SSCT) of 4 s duration in one patient study and found ACT was better than SSCT in depicting average respiratory motion and the SSCT images showed motion-induced reconstruction artifacts. In conclusion, low-dose ACT improved registration of the CT and the PET data in the heart region in our study of four patients. ACT was superior than SSCT for depicting average respiration motion in a patient study.


Assuntos
Interpretação de Imagem Assistida por Computador/métodos , Miocárdio/patologia , Tomografia por Emissão de Pósitrons/instrumentação , Tomografia por Emissão de Pósitrons/métodos , Tomógrafos Computadorizados , Tomografia Computadorizada por Raios X/métodos , Artefatos , Coração , Humanos , Imageamento Tridimensional , Respiração , Técnica de Subtração
5.
World J Gastroenterol ; 11(46): 7284-9, 2005 Dec 14.
Artigo em Inglês | MEDLINE | ID: mdl-16437629

RESUMO

AIM: To demonstrate the (18)F-fluorodeoxyglucose positron emission tomography ((18)F-FDG PET) findings in patients with non-Hodgkinos lymphoma (NHL) involving the gastrointestinal (GI) tract and the clinical utility of modality despite of the known normal uptake of FDG in the GI tract. METHODS: Thirty-three patients with biopsy-proven gastrointestinal NHL who had undergone FDG-PET scan were included. All the patients were injected with 10-15 mCi FDG and scanned approximately 60 min later with a CTI/Siemens HR (+) PET scanner. PET scans were reviewed and the maximum standard uptake value (SUV(max)) of the lesions was measured before and after the treatment, if data were available and compared with histologic diagnoses. RESULTS: Twenty-five patients had a high-grade lymphoma and eight had a low-grade lymphoma. The stomach was the most common site of the involvement (20 patients). In high-grade lymphoma, PET showed focal nodular or diffuse hypermetabolic activity. The average SUV(max)+/-SD was 11.58+/-5.83. After the therapy, the patients whose biopsies showed no evidence of lymphoma had a lower uptake without focal lesions. The SUV(max)+/-SD decreased from 11.58+/-5.83 to 2.21+/-0.78. In patients whose post-treatment biopsies showed lymphoma, the SUV(max)+/-SD was 9.42+/-6.27. Low-grade follicular lymphomas of the colon and stomach showed diffuse hypermetabolic activity in the bowel wall (SUV(max) 8.2 and 10.3, respectively). The SUV(max) was 2.02-3.8 (mean 3.02) in the stomach lesions of patients with MALT lymphoma. ONCLUSION: (18)F-FDG PET contributes to the diagnosis of high-grade gastrointestinal non-Hodgkin's lymphoma, even when there is the normal background FDG activity. Furthermore, the SUV plays a role in evaluating treatment response. Low-grade NHL demonstrates FDG uptake but at a lesser intensity than seen in high-grade NHL.


Assuntos
Neoplasias Gastrointestinais/diagnóstico por imagem , Linfoma não Hodgkin/diagnóstico por imagem , Adulto , Idoso , Idoso de 80 Anos ou mais , Feminino , Fluordesoxiglucose F18 , Humanos , Masculino , Pessoa de Meia-Idade , Tomografia por Emissão de Pósitrons , Estudos Retrospectivos , Tomografia Computadorizada por Raios X
6.
J Nucl Med Technol ; 39(2): 105-10, 2011 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-21565955

RESUMO

UNLABELLED: Equilibrium radionuclide angiocardiography (ERNA) scans are used to evaluate left ventricular function and pericardial anatomy. A photopenic "U-halo" around the cardiac blood pool in the left anterior oblique (LAO) view is commonly seen with pericardial effusion. We describe findings of false-positive pericardial effusion due to breast attenuation in cancer patients. METHODS: Several cases that demonstrated the photopenic U-halo in the LAO view did not have true pericardial effusion. The patients' breast size and how far the breast sagged in reference to the heart silhouette were visually observed in topograms. The oblique tilt position was evaluated to determine the effect it may have in creating the photopenic U-halo. A unique ERNA case demonstrating collateral vessels bilaterally in the breasts was used as a reference marker image to determine the effect of a slightly more anterior versus left lateral oblique tilt in the LAO view. RESULTS: Large breasts can overlie the heart in the LAO projection. The overlying breast can cause the appearance of pericardial effusion in the resulting image by attenuating tissues surrounding the heart. The positioning of the breast also affected the appearance of the photopenic halo. A patient with breast implants who had more upright breasts demonstrated a photopenic area anterior to the left ventricle, whereas a large breast that sagged more laterally demonstrated no photopenic area. CONCLUSION: Patients with large breasts may show a photopenic U-halo in the LAO view dependent on how far the breast sags in reference to the heart silhouette and on the positioning of the oblique tilt. The anterior image should be used to distinguish breast attenuation from a photopenic area surrounding the heart. If both the anterior view and the LAO view demonstrate the U-halo, acquiring another view with a slightly more anterior or lateral oblique position will demonstrate any inconsistency in the photopenic area, thereby excluding a diagnosis of pericardial effusion.


Assuntos
Mama , Imagem do Acúmulo Cardíaco de Comporta , Derrame Pericárdico/diagnóstico por imagem , Mama/anatomia & histologia , Reações Falso-Positivas , Coração/diagnóstico por imagem , Humanos , Neoplasias/complicações , Neoplasias/diagnóstico por imagem , Tamanho do Órgão , Derrame Pericárdico/complicações , Estudos Retrospectivos
7.
Int J Mol Imaging ; 2011: 298102, 2011.
Artigo em Inglês | MEDLINE | ID: mdl-21490727

RESUMO

Lymphoscintigraphy is a nuclear medicine procedure that is used to detect sentinel lymph nodes (SLNs). This project sought to investigate fusion of planar scintigrams with CT topograms as a means of improving the anatomic reference for the SLN localization. Heretofore, the most common lymphoscintigraphy localization method has been backlighting with a (57)Co sheet source. Currently, the most precise method of localization through hybrid SPECT/CT increases the patient absorbed dose by a factor of 34 to 585 (depending on the specific CT technique factors) over the conventional (57)Co backlighting. The new approach described herein also uses a SPECT/CT scanner, which provides mechanically aligned planar scintigram and CT topogram data sets, but only increases the dose by a factor of two over that from (57)Co backlighting. Planar nuclear medicine image fusion with CT topograms has been proven feasible and offers a clinically suitable compromise between improved anatomic details and minimally increased radiation dose.

8.
Clin Nucl Med ; 34(12): 859-61, 2009 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-20139817

RESUMO

We report 2 cases of vulvovaginal melanoma in which sentinel node mapping, performed using Tc-99m filtered sulfur colloid SPECT/CT lymphoscintigraphy, added important information to that provided by planar imaging and played a critical role in surgical planning and subsequent management. In the first case, lymphoscintigraphy planar imaging showed only foci of tracer uptake in the right groin and an equivocal focus in the left groin. SPECT/CT precisely localized these radioactive foci to the right and left inguinal sentinel nodes. The patient then underwent bilateral inguinal sentinel node sampling. In the second case, F-18 FDG PET/CT performed prior to lymphoscintigraphy demonstrated a moderately FDG-avid right inguinal lymph node that was indeterminate in nature. SPECT/CT revealed this lymph node to be a radioactive sentinel lymph node that was seen in the right groin on planar imaging. The patient then underwent right inguinal sentinel node sampling. Because pathologic study showed metastasis to the sentinel node, a planned pelvic exenteration was canceled, and the patient was referred for systemic treatment. Preoperative SPECT/CT lymphoscintigraphy is ideal for mapping the unpredicted lymphatic drainage pathways within the complex pelvic anatomy and this technique may also be used in the preoperative workup of other gynecologic malignancies.


Assuntos
Linfonodos/diagnóstico por imagem , Melanoma/diagnóstico , Melanoma/secundário , Tomografia Computadorizada de Emissão de Fóton Único/métodos , Tomografia Computadorizada por Raios X/métodos , Neoplasias Vaginais/diagnóstico , Neoplasias Vulvares/diagnóstico , Idoso , Feminino , Humanos , Metástase Linfática , Pessoa de Meia-Idade , Reprodutibilidade dos Testes , Sensibilidade e Especificidade , Biópsia de Linfonodo Sentinela/métodos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA