Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Mais filtros

Base de dados
Tipo de documento
País/Região como assunto
Intervalo de ano de publicação
1.
Int J Artif Organs ; 46(4): 226-234, 2023 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-36895175

RESUMO

We sought to evaluate whether differences in left ventricular assist device (LVAD) canula alignment are associated with stroke. There is a paucity of clinical data on contribution of LVAD canulae alignment to strokes. We conducted a retrospective analysis of patients who underwent LVAD implantation at Houston Methodist hospital from 2011 to 2016 and included those who had undergone cardiac computed tomography (CT) with contrast. LVAD graft alignment using X-ray, echocardiography, and cardiac CT was evaluated. The primary outcome was stroke within 1 year of LVAD implantation. Of the 101 patients that underwent LVAD Implantation and cardiac CT scan during the study period, 78 met inclusion criteria. The primary outcome occurred in 12 (15.4%) patients with a median time to stroke of 77 days (interquartile range: 42-132 days). Of these, 10 patients had an ischemic and two had hemorrhagic strokes. The predominant device type was Heart Mate II (94.8%). Patients with LVAD outflow cannula to aortic angle lesser than 37.5° and those with outflow graft diameter of anastomosis less than 1.5 cm (assessed by cardiac CT) had significantly higher stroke risk (p < 0.001 and p = 0.01 respectively). In HMII patients, a lower LVAD speed at the time of CT scan was associated with stroke. Further studies are needed to identify optimal outflow graft configuration to mitigate stroke risk.


Assuntos
Insuficiência Cardíaca , Coração Auxiliar , Acidente Vascular Cerebral , Humanos , Estudos Retrospectivos , Cânula , Ecocardiografia , Acidente Vascular Cerebral/diagnóstico por imagem , Acidente Vascular Cerebral/etiologia , Coração Auxiliar/efeitos adversos
2.
J Ophthalmic Inflamm Infect ; 6(1): 44, 2016 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-27864795

RESUMO

BACKGROUND: The objective of this study was to determine the prevalence of symptoms of ocular surface disease and its relationship with associated risk factors in students from the University of Monterrey using Ocular Surface Disease (OSDI) questionnaire. METHODS: A cross-sectional survey was conducted between October and December 2014 to assess the prevalence and risk factors for ocular surface disease in a group of students from Universidad de Monterrey in Monterrey, Mexico. The severity of the disease was measured via the Ocular Surface Disease Index (OSDI) questionnaire. RESULTS: The OSDI average value was 26.85 ± 20.79 points, with 70.4% of students (579) had OSDI score higher than 12 points. Women had ocular surface disease 1.63 times more than men (OR 1.29, 95% CI 1.13,1.48). Students who used ophthalmic drops have an OR 2.00 (95% CI 1.65,2.40), and students who smoke have an OR 1.24 (95% CI 1.06,1.46). Use of contact lenses, hours in front of computer or history of refractive surgery has low-estimated effect on the probability of presenting an ocular disease. CONCLUSIONS: University students have a prevalence of 70.4% of ocular surface disease (OSD). OSD was associated with gender (women have a higher prevalence), smoking and the use of eye drops. A program to modify these risk factors to reduce the prevalence is needed.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA