Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 28
Filtrar
1.
World J Surg Oncol ; 19(1): 80, 2021 Mar 18.
Artigo em Inglês | MEDLINE | ID: mdl-33736652

RESUMO

BACKGROUND: Many oncologists debate if lobular neoplasia (LN) is a risk factor or an obligatory precursor of more aggressive disease. This study has three aims: (i) describe the different treatment options (surgical resection vs observation), (ii) investigate the upgrade rate in surgically treated patients, and (iii) evaluate the long-term occurrences of aggressive disease in both operated and unoperated patients. METHODS: A series of 122 patients with LN bioptic diagnosis and follow-up information were selected. Clinical, radiological, and pathological data were collected from medical charts. At definitive histology, either invasive or ductal carcinoma in situ was considered upgraded lesions. RESULTS: Atypical lobular hyperplasia (ALH), lobular carcinoma in situ (LCIS), and high-grade LN (HG-LN) were diagnosed in 44, 63, and 15 patients, respectively. The median follow-up was 9.5 years. Ninety-nine patients were surgically treated, while 23 underwent clinical-radiological follow-up. An upgrade was observed in 28/99 (28.3%). Age ≥ 54 years (OR 4.01, CI 1.42-11.29, p = 0.009), Breast Imaging-Reporting and Data System (BI-RADS) categories 4-5 (OR 3.76, CI 1.37-10.1, p = 0.010), and preoperatory HG-LN diagnosis (OR 8.76, 1.82-42.27, p = 0.007) were related to upgraded/aggressive disease. During follow-up, 8 patients developed an ipsilateral malignant lesion, four of whom were not initially operated (4/23, 17%). CONCLUSIONS: BI-RADS categories 4-5, HG-LN diagnosis, and age ≥ 54 years were features associated with an upgrade at definitive surgery. Moreover, 17% of unoperated cases developed an aggressive disease, emphasizing that LN patients need close surveillance due to the long-term risk of breast cancer.


Assuntos
Neoplasias da Mama , Carcinoma in Situ , Carcinoma Lobular , Neoplasias da Mama/diagnóstico por imagem , Neoplasias da Mama/epidemiologia , Neoplasias da Mama/cirurgia , Carcinoma Lobular/diagnóstico por imagem , Carcinoma Lobular/cirurgia , Seguimentos , Humanos , Hiperplasia , Pessoa de Meia-Idade , Prognóstico
2.
Breast Cancer Res Treat ; 166(3): 765-773, 2017 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-28819781

RESUMO

PURPOSE: To compare the interpretive performance of synthetic mammography (SM), reconstructed from digital breast tomosynthesis (DBT), and full-field digital mammography (FFDM) in a diagnostic setting, covering different conditions of breast density and mammographic signs. METHODS: A retrospective analysis was conducted on 231 patients, who underwent FFDM and DBT (from which SM images were reconstructed) between September 2014-September 2015. The study included 250 suspicious breast lesions, all biopsy proven: 148 (59.2%) malignant and 13 (5.2%) high-risk lesions were confirmed by surgery, 89 (35.6%) benign lesions had radiological follow-up. Two breast radiologists, blinded to histology, independently reviewed all cases. Readings were performed with SM alone, then with FFDM, collecting data on: probability of malignancy for each finding, lesion conspicuity, mammographic features and dimensions of detected lesions. RESULTS: Agreement between readers was good for BI-RADS classification (Cohen's k-coefficient = 0.93 ± 0.02) and for lesion dimension (Wilcoxon's p = 0.76). Visibility scores assigned to SM and FFDM for each lesion were similar for non-dense and dense breasts, however, there were significant differences (p = 0.0009) in distribution of mammographic features subgroups. SM and FFDM had similar sensitivities in non-dense (respectively 94 vs. 91%) and dense breasts (88 vs. 80%) and for all mammographic signs (93 vs. 87% for asymmetric densities, 96 vs. 75% for distortion, 92 vs. 85% for microcalcifications, and both 94% for masses). Based on all data, there was a significant difference in sensitivity for SM (92%) vs. FFDM (87%), p = 0.02, whereas the two modalities yielded similar results for specificity (SM: 60%, FFDM: 62%, p = 0.21). CONCLUSIONS: SM alone showed similar interpretive performance to FFDM, confirming its potential role as an alternative to FFDM in women having tomosynthesis, with the added advantage of halving the patient's dose exposure.


Assuntos
Neoplasias da Mama/diagnóstico por imagem , Neoplasias da Mama/diagnóstico , Mama/diagnóstico por imagem , Mamografia/métodos , Tomografia Computadorizada por Raios X/métodos , Adulto , Idoso , Biópsia , Mama/patologia , Densidade da Mama , Neoplasias da Mama/patologia , Feminino , Humanos , Intensificação de Imagem Radiográfica/métodos , Estudos Retrospectivos
3.
Radiol Med ; 122(10): 723-730, 2017 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-28540564

RESUMO

This position paper, issued by ICBR/SIRM and GISMa, summarizes the evidence on DBT and provides recommendations for its use. In the screening setting, DBT in adjunct to digital mammography (DM) increased detection rate by 0.5-2.7‰ and decreased false positives by 0.8-3.6% compared to DM alone in observational and double-testing experimental studies. The reduction in recall rate could be less prominent in those screening programs which already have low recall rates with DM. The increase in radiation exposure associated with DM/DBT protocols has been solved by the introduction of synthetic mammograms (sDM) reconstructed from DBT datasets. Thus, whenever possible, sDM/DBT should be preferred to DM/DBT. However, before introducing DBT as a routine screening tool for average-risk women, we should wait for the results of randomized controlled trials and for a statistically significant and clinically relevant reduction in the interval cancer rate, hopefully associated with a reduction in the advanced cancer rate. Otherwise, a potential for overdiagnosis and overtreatment cannot be excluded. Studies exploring this issue are ongoing. Screening of women at intermediate risk should follow the same recommendations, with particular protocols for women with previous BC history. In high-risk women, if mammography is performed as an adjunct to MRI or in the case of MRI contraindications, sDM/DBT protocols are suggested. Evidence exists in favor of DBT usage in women with clinical symptoms/signs and asymptomatic women with screen-detected findings recalled for work-up. The possibility to perform needle biopsy or localization under DBT guidance should be offered when DBT-only findings need characterization or surgery.


Assuntos
Neoplasias da Mama/diagnóstico por imagem , Mamografia , Detecção Precoce de Câncer , Medicina Baseada em Evidências , Feminino , Humanos , Itália
4.
Radiol Med ; 121(11): 834-837, 2016 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-27406629

RESUMO

Women who underwent chest radiation therapy (CRT) during pediatric/young-adult age (typically, lymphoma survivors) have an increased breast cancer risk, in particular for high doses. The cumulative incidence from 40 to 45 years of age is 13-20 %, similar to that of BRCA mutation carriers for whom contrast-enhanced magnetic resonance imaging (MRI) is recommended. However, in women who underwent CRT, MRI sensitivity is lower (63-80 %) and that of mammography higher (67-70 %) than those observed in women with hereditary predisposition, due to a higher incidence of ductal carcinoma in situ with microcalcifications and low neoangiogenesis. A sensitivity close to 95 % can be obtained only using mammography as an adjunct to MRI. Considering the available evidence, women who underwent CRT before 30 receiving a cumulative dose ≥10 Gy should be invited after 25 (or, at least, 8 years after CRT) to attend the following program: 1. interview about individual risk profile and potential of breast imaging; 2. annual MRI using the same protocol recommended for women with hereditary predisposition; 3. annual bilateral two-view full-field digital mammography or digital breast tomosynthesis (DBT) with synthetic 2D reconstructions. Mammography and MRI can be performed at once or alternately every 6 months. In the case of MRI or contrast material contraindications, ultrasound will be performed instead of MRI. Reporting using BI-RADS is recommended. At the age for entering population screening, the individual risk profile will be discussed with the woman about opting for only mammography/DBT screening or for continuing the intensive protocol.


Assuntos
Neoplasias da Mama/diagnóstico por imagem , Linfoma/radioterapia , Imageamento por Ressonância Magnética , Mamografia , Neoplasias Induzidas por Radiação/diagnóstico por imagem , Vigilância da População , Adulto , Consenso , Meios de Contraste , Feminino , Humanos , Itália , Pessoa de Meia-Idade , Fatores de Risco
5.
Radiol Med ; 121(12): 891-896, 2016 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-27601142

RESUMO

Women who were previously treated for breast cancer (BC) are an important particular subgroup of women at intermediate BC risk. Their breast follow-up should be planned taking in consideration a 1.0-1.5 % annual rate of loco-regional recurrences and new ipsilateral or contralateral BCs during 15-20 years, and be based on a regional/district invitation system. This activity should be carried out by a Department of Radiology integrating screening and diagnostics in the context of a Breast Unit. We recommend the adoption of protocols dedicated to women previously treated for BC, with a clear definition of responsibilities, methods for invitation, site(s) of visits, methods for clinical and radiological evaluation, follow-up duration, role and function of family doctors and specialists. These women will be invited to get a mammogram in dedicated sessions starting from the year after the end of treatment. The planned follow-up duration will be at least 10 years and will be defined on the basis of patient's age and preferences, taking into consideration organizational matters. Special agreements can be defined in the case of women who have their follow-up planned at other qualified centers. Dedicated screening sessions should include: evaluation of familial/personal history (if previously not done) for identifying high-risk conditions which could indicate a different screening strategy; immediate evaluation of mammograms by one or, when possible, two breast radiologists with possible addition of supplemental mammographic views, digital breast tomosynthesis, clinical breast examination, breast ultrasound; and prompt planning of possible further workup. Results of these screening sessions should be set apart from those of general female population screening and presented in dedicated reports. The following research issues are suggested: further risk stratification and effectiveness of follow-up protocols differentiated also for BC pathologic subtype and molecular classification, and evaluation of different models of survivorship care, also in terms of cost-effectiveness.


Assuntos
Neoplasias da Mama/diagnóstico por imagem , Neoplasias da Mama/patologia , Continuidade da Assistência ao Paciente , Recidiva Local de Neoplasia/diagnóstico por imagem , Recidiva Local de Neoplasia/patologia , Neoplasias da Mama/terapia , Consenso , Feminino , Humanos , Itália , Mamografia , Programas de Rastreamento , Medição de Risco , Sociedades Médicas
6.
Radiology ; 277(1): 56-63, 2015 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-25961633

RESUMO

PURPOSE: To evaluate a commercial tomosynthesis computer-aided detection (CAD) system in an independent, multicenter dataset. MATERIALS AND METHODS: Diagnostic and screening tomosynthesis mammographic examinations (n = 175; cranial caudal and mediolateral oblique) were randomly selected from a previous institutional review board-approved trial. All subjects gave informed consent. Examinations were performed in three centers and included 123 patients, with 132 biopsy-proven screening-detected cancers, and 52 examinations with negative results at 1-year follow-up. One hundred eleven lesions were masses and/or microcalcifications (72 masses, 22 microcalcifications, 17 masses with microcalcifications) and 21 were architectural distortions. Lesions were annotated by radiologists who were aware of all available reports. CAD performance was assessed as per-lesion sensitivity and false-positive results per volume in patients with negative results. RESULTS: Use of the CAD system showed per-lesion sensitivity of 89% (99 of 111; 95% confidence interval: 81%, 94%), with 2.7 ± 1.8 false-positive rate per view, 62 of 72 lesions detected were masses, 20 of 22 were microcalcification clusters, and 17 of 17 were masses with microcalcifications. Overall, 37 of 39 microcalcification clusters (95% sensitivity, 95% confidence interval: 81%, 99%) and 79 of 89 masses (89% sensitivity, 95% confidence interval: 80%, 94%) were detected with the CAD system. On average, 0.5 false-positive rate per view were microcalcification clusters, 2.1 were masses, and 0.1 were masses and microcalcifications. CONCLUSION: A digital breast tomosynthesis CAD system can allow detection of a large percentage (89%, 99 of 111) of breast cancers manifesting as masses and microcalcification clusters, with an acceptable false-positive rate (2.7 per breast view). Further studies with larger datasets acquired with equipment from multiple vendors are needed to replicate the findings and to study the interaction of radiologists and CAD systems.


Assuntos
Neoplasias da Mama/diagnóstico por imagem , Interpretação de Imagem Assistida por Computador , Mamografia/métodos , Intensificação de Imagem Radiográfica , Adulto , Idoso , Idoso de 80 Anos ou mais , Doenças Mamárias/diagnóstico por imagem , Calcinose/diagnóstico por imagem , Feminino , Humanos , Pessoa de Meia-Idade , Estudos Prospectivos , Sensibilidade e Especificidade
7.
Eur Radiol ; 25(1): 9-14, 2015 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-25163902

RESUMO

OBJECTIVES: To compare DBT and FFDM in the classification of microcalcification clusters (MCs) using BI-RADS. METHODS: This Institutional Review Board-approved study was undertaken in three centres. A total of 107 MCs evaluated with both DBT and FFDM were randomised for prospective reading by six experienced breast radiologists and classified using BI-RADS. RESULTS: The benign/malignant ratio of MC was 66/41. Of 11/107 discordant results, DBT classified MCs as R2 whereas FFDM classified them as R3 in 9 and R4 in 2. Three of these (3/107 = 2.8%) were malignant; 8 (7.5%) were nonmalignant and were correctly classified as R2 on DBT but incorrectly classified as R3 on FFDM. Estimated sensitivity and specificity, respectively, were 100% (95% CI: 91% to 100%) and 94.6% (95% CI: 86.7% to 98.5%) for FFDM and 91.1% (95% CI: 78.8% to 97.5%) and 100% (95% CI: 94.8% to 100%) for DBT. Overall intra- and interobserver agreements were 0.75 (95% CI: 0.61-0.84) and 0.73 (95% CI: 0.62-0.78). CONCLUSIONS: Most MCs are scored similarly on FFDM and DBT. Although a minority (11/107) of MCs are classified differently on FFDM (benign MC classified as R3) and DBT (malignant MC classified as R2), this may have clinical relevance. KEY POINTS: • The BI-RADS classification of MC differs for FFDM and DBT in 11/107 cases • DBT assigned lower BI-RADS classes compared to FFDM in 11 clusters • In 4/107 DBT may have missed some malignant and high-risk lesions • In 7/107 the 'underclassification' on DBT was correct, potentially avoiding unnecessary biopsies • DBT may miss a small proportion of malignant lesions.


Assuntos
Doenças Mamárias/diagnóstico por imagem , Calcinose/diagnóstico por imagem , Mamografia/métodos , Intensificação de Imagem Radiográfica/métodos , Tomografia por Raios X/métodos , Diagnóstico Diferencial , Feminino , Seguimentos , Humanos , Pessoa de Meia-Idade , Estudos Prospectivos , Curva ROC , Reprodutibilidade dos Testes
8.
Eur Radiol ; 25(9): 2673-81, 2015 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-25813013

RESUMO

OBJECTIVES: Preoperative breast magnetic resonance (MR) often generates additional suspicious findings needing further investigations. Targeted breast ultrasound (US) is the standard tool to characterize MR additional lesions. The purpose of this study is to evaluate the potential role of digital breast tomosynthesis (DBT) to characterize MR detected additional findings, unidentified at targeted breast US. METHODS: This prospective study included women who a) had biopsy-proven, newly diagnosed breast cancers detected at conventional 2D mammography and/or US, referred to breast MR for tumour staging; and b) had DBT if additional MR findings were not detected at targeted ('second look') US. RESULTS: In 520 patients, MR identified 164 (in 114 women, 22%) additional enhancing lesions. Targeted US identified 114/164 (69.5%) of these, whereas 50/164 (30.5%) remained unidentified. DBT identified 32/50 of these cases, increasing the overall characterization of MR detected additional findings to 89.0% (146/164). Using DBT the identified lesions were significantly more likely to be malignant than benign MR-detected additional lesions (p = 0.04). CONCLUSIONS: DBT improves the characterization of additional MR findings not identified at targeted breast US in preoperative breast cancer staging. KEY POINTS: • Targeted US identified 114 of 164 (69.5%) additional enhancing lesions at preoperative breast MRI. • DBT identified a further 32 of the 50 lesions unidentified on targeted US. • DBT improved the characterization of additional MR findings for breast cancer staging.


Assuntos
Neoplasias da Mama/diagnóstico por imagem , Neoplasias da Mama/patologia , Imageamento por Ressonância Magnética , Mamografia , Ultrassonografia Mamária , Adulto , Idoso , Feminino , Humanos , Pessoa de Meia-Idade , Estadiamento de Neoplasias , Estudos Prospectivos
9.
Radiol Med ; 120(4): 369-76, 2015 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-25120079

RESUMO

PURPOSE: The authors sought to compare the diagnostic performance of the Mammotome(®) and EnCor(®) vacuum-assisted breast biopsy (VABB) systems in the assessment of suspicious mammographic microcalcifications. MATERIALS AND METHODS: Between January 2011 and July 2012, a total of 169 VABB were performed by stereotactic guidance on a prone table. The Mammotome(®) 11G (S1) or EnCor(®) 10G (S2) probes were used randomly. Sampling time and the number of frustules collected were considered; sensitivity, specificity, diagnostic accuracy, positive and negative predictive value (PPV, NPV) of both procedures were evaluated, considering the final histological examination as reference (B1, B3, B5 lesions underwent surgical excision; B2 lesion were considered confirmed after a negative follow-up of at least 1 year). RESULTS: There were no statistically significant differences between the two groups of patients according to the number of procedures (S1 82/169; S2 87/169), average age, BIRADS category (4a, b), and average size of the lesions. The two systems did not differ statistically for correlation with the final histology (S1 k = 0.94 ± 0.06; S2 k = 0.92 ± 0.08) and underestimation of B3 lesions or in situ (S1 4.5%; S2 4.3%). Sensitivity, specificity, PPV, NPV, diagnostic accuracy of S1 and S2 were also not statistically different. The systems differed only in sampling time (S1 80; S2 63 s), but not in total procedure time. CONCLUSIONS: Our study confirms the effectiveness of VABB in the assessment of microcalcifications and highlights the lack of significant differences between the two systems in terms of diagnostic performance.


Assuntos
Biópsia por Agulha/instrumentação , Neoplasias da Mama/patologia , Calcinose/patologia , Biópsia Guiada por Imagem/instrumentação , Vácuo , Neoplasias da Mama/diagnóstico por imagem , Calcinose/diagnóstico por imagem , Feminino , Humanos , Mamografia , Pessoa de Meia-Idade , Valor Preditivo dos Testes , Sensibilidade e Especificidade , Técnicas Estereotáxicas
10.
Radiol Med ; 120(4): 377-85, 2015 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-25155350

RESUMO

PURPOSE: To retrospectively assess the risk of breast cancer associated with the radial scar (RS) microhistological diagnosis, also taking into consideration the percutaneous biopsy devices used, as well as the different performances of the mammographic systems (analogical, digital and tomosynthesis) in the radiological diagnosis of RS. MATERIALS AND METHODS: Between March 2002 and November 2011, 80 RSs were identified using the analogical, digital and tomosynthesis mammographic systems. Based on the microhistological examination, the patients were divided into three groups [RS without hyperplasic-proliferative lesions (HPL); RS with HPL; RS with cancer] and we assessed the risk of cancer associated with RS in the first and second group. We evaluated the mammographic features and the BI-RADS categories assigned to RSs, the biopsy devices used and the differences between the pathological examination and the microhistological diagnosis (p < 0.05). RESULTS: Based on the microhistological examination, 51/80 patients were included in the first group (9 of them not subjected to surgery), 25/80 in the second group and 4/80 in the third one. At the final histological examination, there were 7/42 (16.7%) cancers in the first group and 8/25 (32%) in the second group. The largest number of microhistological underestimation occurred in the patients who were subjected to core biopsy (15 cases) (p < 0.05). Tomosynthesis improved (p < 0.05) the identification of the RS. CONCLUSIONS: 22.3% of the RSs was associated with cancer. Given that at microhistological examination 16.7% of the RS without HPL was cancer at pathology, the surgical excision is preferred. Tomosynthesis was useful to detect parenchymal distortions.


Assuntos
Biópsia com Agulha de Grande Calibre , Neoplasias da Mama/diagnóstico por imagem , Cicatriz/diagnóstico por imagem , Biópsia Guiada por Imagem , Neoplasias da Mama/patologia , Neoplasias da Mama/cirurgia , Cicatriz/patologia , Feminino , Humanos , Mamografia , Pessoa de Meia-Idade , Estudos Retrospectivos , Fatores de Risco , Técnicas Estereotáxicas
11.
Breast J ; 20(3): 243-8, 2014.
Artigo em Inglês | MEDLINE | ID: mdl-24750509

RESUMO

Ductal carcinoma in situ (DCIS) is a common neoplasm that may be associated with focal invasive breast cancer lesions. The aim of our study was to evaluate the role of preoperative magnetic resonance imaging (MRI) in determining occult invasive presence and disease extent in patients with preoperative diagnosis of pure DCIS. We analyzed 125 patients with postoperative pure DCIS (n = 91) and DCIS plus invasive component (n = 34). Diagnostic mammography (MRX) showed a size underestimation rate of 30.4% while MRI showed an overestimation rate of 28.6%. Comparing the mean absolute error between preoperative MRI and MRX evaluations and final disease extent, MRI showed an improved accuracy of 51.2%. In our analysis preoperative breast MRI showed a better accuracy in predicting postoperative pathologic extent of disease, adding strength to the growing evidences that preoperative MRI can lead to a more appropriate management of DCIS patients.


Assuntos
Neoplasias da Mama/patologia , Carcinoma Intraductal não Infiltrante/patologia , Imageamento por Ressonância Magnética/métodos , Adulto , Fatores Etários , Idoso , Neoplasias da Mama/diagnóstico por imagem , Neoplasias da Mama/cirurgia , Carcinoma Intraductal não Infiltrante/diagnóstico por imagem , Carcinoma Intraductal não Infiltrante/cirurgia , Feminino , Humanos , Mamografia , Pessoa de Meia-Idade , Valor Preditivo dos Testes , Cuidados Pré-Operatórios , Estudos Retrospectivos , Adulto Jovem
12.
Radiol Med ; 119(10): 741-9, 2014 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-24610166

RESUMO

OBJECTIVE: This study was done to assess breast density on digital mammography and digital breast tomosynthesis according to the visual Breast Imaging Reporting and Data System (BI-RADS) classification, to compare visual assessment with Quantra software for automated density measurement, and to establish the role of the software in clinical practice. MATERIALS AND METHODS: We analysed 200 digital mammograms performed in 2D and 3D modality, 100 of which positive for breast cancer and 100 negative. Radiological density was assessed with the BI-RADS classification; a Quantra density cut-off value was sought on the 2D images only to discriminate between BI-RADS categories 1-2 and BI-RADS 3-4. Breast density was correlated with age, use of hormone therapy, and increased risk of disease. RESULTS: The agreement between the 2D and 3D assessments of BI-RADS density was high (K 0.96). A cut-off value of 21% is that which allows us to best discriminate between BI-RADS categories 1-2 and 3-4. Breast density was negatively correlated to age (r = -0.44) and positively to use of hormone therapy (p = 0.0004). Quantra density was higher in breasts with cancer than in healthy breasts. CONCLUSIONS: There is no clear difference between the visual assessments of density on 2D and 3D images. Use of the automated system requires the adoption of a cut-off value (set at 21%) to effectively discriminate BI-RADS 1-2 and 3-4, and could be useful in clinical practice.


Assuntos
Neoplasias da Mama/diagnóstico por imagem , Mama/patologia , Mamografia , Intensificação de Imagem Radiográfica , Adulto , Fatores Etários , Idoso , Idoso de 80 Anos ou mais , Detecção Precoce de Câncer/métodos , Terapia de Reposição de Estrogênios/efeitos adversos , Feminino , Humanos , Mamografia/métodos , Pessoa de Meia-Idade , Interpretação de Imagem Radiográfica Assistida por Computador , Reprodutibilidade dos Testes , Estudos Retrospectivos , Medição de Risco , Fatores de Risco
13.
Br J Radiol ; 97(1155): 505-512, 2024 Feb 28.
Artigo em Inglês | MEDLINE | ID: mdl-38419148

RESUMO

Acellular dermal matrices (ADMs) are biological engineered tissues, which may provide an immunologically inert scaffold in breast reconstruction. Since the literature on imaging features of ADMs is limited, radiologists must be aware of the common imaging appearances of ADM, to differentiate normal conformation from residual or recurrent disease. Our purpose is to review the current role of ADMs in implant-based breast reconstruction, describing the normal imaging findings at ultrasound, mammography, and MRI also considering the possible changes over time. In this pictorial essay, we reviewed imaging features of ADMs described in the literature and we reported our experience in patients who underwent reconstructive surgery with human or animal ADM for newly diagnosed breast cancer.


Assuntos
Derme Acelular , Neoplasias da Mama , Mamoplastia , Cirurgia Plástica , Animais , Humanos , Feminino , Mastectomia/métodos , Mamoplastia/métodos , Neoplasias da Mama/diagnóstico por imagem , Neoplasias da Mama/cirurgia
14.
Radiol Med ; 118(7): 1119-36, 2013 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-23801389

RESUMO

PURPOSE: Accurate measurement of breast tumour size is fundamental for treatment planning. We compared the accuracy of digital mammography (DM), digital breast tomosynthesis (DBT), ultrasound (US) and magnetic resonance imaging (MRI) for the preoperative evaluation of breast cancer size. MATERIALS AND METHODS: We retrospectively reviewed 149 breast cancers in 110 patients who underwent DM, DBT, US and MRI between January 2010 and December 2011, before definitive surgery. The lesions were measured by two radiologists, without knowledge of the final histological examination, considered the gold standard. For each imaging modality, the maximum tumour size was measured to the nearest millimetre; the measurements were considered concordant if they were within ± 5 mm. Pearson's correlation coefficient was calculated for each imaging modality. RESULTS: The median pathological tumour size was 22.3 mm. MRI and DBT had a level of concordance with pathology of 70% and 66%, respectively, which was higher than that of DM (54%). DBT and MRI measurements had a better correlation with pathological tumour size (R:0.89 and R:0.92, respectively) compared to DM (R:0.83) and US (R:0.77). CONCLUSIONS: DBT and MRI are superior to DM and US in the preoperative assessment of breast tumour size. DBT seems to improve the accuracy of DM, although MRI remains the most accurate imaging modality for breast cancer extension.


Assuntos
Neoplasias da Mama/patologia , Adulto , Idoso , Neoplasias da Mama/cirurgia , Feminino , Humanos , Imageamento por Ressonância Magnética , Mamografia , Pessoa de Meia-Idade , Estadiamento de Neoplasias , Estudos Retrospectivos , Tomografia Computadorizada por Raios X , Ultrassonografia Mamária
15.
Eur J Radiol ; 122: 108766, 2020 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-31809942

RESUMO

PURPOSE: To compare the rates of mastectomy and re-operation after breast-conserving surgery (BCS) among patients who had different pre-operative multi-modality imaging, hence identifying significant predictors of mastectomy and re-operations within each group. METHOD: Retrospective study of consecutive patients with primary breast cancer treated January 2010 - December 2016, divided in 3 groups, undergoing pre-operative local staging respectively with conventional imaging modalities only (2D mammography, ultrasound (US)), conventional imaging and tomosynthesis (DBT) and/or MRI. The primary outcome was identification of significant predictors of surgical outcomes, within each group. Study variables examined in univariate analysis were age, lesion dimension, breast density, multifocality, tumor size, histology, and if associated with outcomes they were included in binary logistic regression analysis. RESULTS: Amongst 1547 patients, patient and tumor characteristics differed across the three groups, as did mastectomy rates which were 18 % (102/562) for 2D + US, 36 % (154/428) for 2D + DBT + US, 45 % (250/557) for 2D+/-DBT + US + MRI(p < 0.001). Variables strongly associated with mastectomy were larger lesions and multifocality (as was multi-modality group). Re-operation rate showed an opposite trend: 12.2 % (56/459) for 2D + US, 8 % (22/272) for 2D + DBT + US, 6.5 % (20/306) for 2D+/-DBT + US + MRI. Re-operation rate for 2D+/-DBT + US + MRI was lower than for 2D + US (p = 0.01) but similar to 2D + DBT + US (p = 0.58). Patients who had 2D + US and re-operations had significantly larger lesions, more underestimation, higher proportion of invasive carcinoma with in-situ component than those who did not require re-operation. CONCLUSIONS: Patients who had larger tumors and multifocal disease were more frequently staged by adding DBT and/or MRI to conventional imaging (mammography and US) which was associated with more extensive surgical treatment but lower reoperation rates.


Assuntos
Neoplasias da Mama/patologia , Idoso , Densidade da Mama/fisiologia , Neoplasias da Mama/cirurgia , Feminino , Humanos , Imageamento por Ressonância Magnética/métodos , Mamografia/métodos , Mastectomia/métodos , Mastectomia Segmentar/métodos , Pessoa de Meia-Idade , Imagem Multimodal , Estadiamento de Neoplasias , Cuidados Pré-Operatórios , Reoperação/estatística & dados numéricos , Estudos Retrospectivos , Resultado do Tratamento , Ultrassonografia
16.
Br J Radiol ; 93(1109): 20190785, 2020 May 01.
Artigo em Inglês | MEDLINE | ID: mdl-32101449

RESUMO

OBJECTIVE: To compare standard specimen mammography (SSM) with remote intraoperative specimen mammography (ISM) assessment in breast conserving-surgery (BCS) based on operative times, intraoperative additional excision (IAE) and re-intervention rates. METHODS AND MATERIALS: We retrospectively compared 129 consecutive patients (136 lesions) who had BCS with SSM at our centre between 11/2011 and 02/2013 with 138 consecutive patients (144 lesions) who underwent BCS with ISM between 08/2014 and 02/2015.SSM or ISM were performed to confirm the target lesions within the excised specimen and margin adequacy. The utility of SMM and ISM was evaluated considering pathology as gold-standard, using χ2 or Fisher's exact tests for comparison of categorical variables, and non-parametric Mann-Whitney test for continuous variables. RESULTS: The two groups did not statistically differ for age (p = 0.20), lesion size (p = 0.29) and morphology (p = 0.82) or tumor histology type (p = 0.65). Intraoperative time was significantly longer (p < 0.00001) for SSM (132 ± 43 min) than for ISM (90 ± 42 min). The proportions requiring IAE did not significantly differ between SSM group (39/136 lesions (40%)) and ISM group (52/144 lesions (57%)) (p = 0.19), overall and in stratified analysis by mammographic features. Re-intervention rates were not statistically different between the two groups [SSM:19/136 (14%), ISM:13/144 (9%); p = 0.27]. CONCLUSION: The introduction of ISM in BCS significantly reduced surgical time but did not change IAE and re-intervention rates, highlighting facilitated communication between surgeons and radiologists. ADVANCES IN KNOWLEDGE: Compared to standard mammography imaging, the use of ISM significantly reduced surgical time.


Assuntos
Neoplasias da Mama/diagnóstico por imagem , Neoplasias da Mama/cirurgia , Carcinoma Ductal de Mama/cirurgia , Carcinoma Intraductal não Infiltrante/cirurgia , Mamografia/métodos , Mastectomia Segmentar/métodos , Carcinoma Ductal de Mama/diagnóstico por imagem , Carcinoma Intraductal não Infiltrante/diagnóstico por imagem , Feminino , Humanos , Cuidados Intraoperatórios/métodos , Pessoa de Meia-Idade , Duração da Cirurgia , Consulta Remota/métodos , Reoperação/estatística & dados numéricos , Manejo de Espécimes
17.
Eur J Radiol ; 130: 109194, 2020 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-32795765

RESUMO

PURPOSE: To investigate clinical, radiologic and pathologic features of B3 lesions diagnosed on VABB targeting microcalcifications, for identifying predictors of malignancy. METHOD: This retrospective multi-centre study included consecutive VABBs performed over a 10-year period on suspicious microcalcifications not associated with other radiological signs diagnosed as B3 on histology from VABB, with outcomes ascertained by surgical excision. Clinical, demographic, radiological and histological (B3 subcategory) data were collected. For statistical analysis (univariate and binary logistic regression), the primary outcome variable was the upgrade rate to malignancy after surgery. Predictors of upgrade to malignancy were identified from clinical, demographic, radiological and pathological variables (including B3 subcategory). RESULTS: Amongst 447 VABBs, there were 57(12.7 %) upgrades to malignancy at surgical histology (36 DCIS and 21 invasive cancer). At univariate analysis, variables significantly associated with increased risk of upgrade to malignancy were age>55 years (p = 0.01), lesion size>10 mm (p < 0.0001), BI-RADS 4b-c and 5 (p = 0.0001), and fine pleomorphic morphology (p = 0.002) of microcalcifications. Binary logistic regression confirmed as significant independent risk factors age, lesion size and BI-RADS category (p = 0.02, 0.02 and 0.0006 respectively). Amongst subcategories of B3 lesions, lobular neoplasia was significantly(p = 0.04) associated with upgrade, confirmed as an independent risk factor [p = 0.03, OR = 2.3(1.1-4.7)]. Flat epithelial atypia was significantly(p = 0.004) associated with reduced odds of upgrade, but binary logistic regression showed only borderline association [p = 0.052, OR = 0.4(0.2-1.01)]. CONCLUSIONS: Across B3 lesions diagnosed on histology from VABB of suspicious microcalcifications, older age, size>10 mm, BI-RADS category≥ 4b on imaging, and lobular neoplasia were risk factors for upgrade to malignancy. This information can be used to discuss patients' tailored management options.


Assuntos
Neoplasias da Mama/patologia , Calcinose/patologia , Adulto , Idoso , Biópsia por Agulha/métodos , Mama/patologia , Neoplasias da Mama/cirurgia , Calcinose/cirurgia , Carcinoma in Situ/patologia , Carcinoma Intraductal não Infiltrante/patologia , Carcinoma Intraductal não Infiltrante/cirurgia , Diagnóstico Diferencial , Feminino , Humanos , Biópsia Guiada por Imagem , Modelos Logísticos , Mamografia , Mastectomia , Pessoa de Meia-Idade , Lesões Pré-Cancerosas/patologia , Estudos Retrospectivos
18.
Mod Pathol ; 22(6): 762-9, 2009 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-19287465

RESUMO

Columnar cell lesions of the breast are increasingly recognized at mammography for their tendency to calcify. We studied 392 vacuum-assisted core biopsies performed solely for calcifications to evaluate the frequency of columnar cell lesions, their relationship with radiological risk, appearance of calcifications, and clinical data. Management and follow-up of columnar cell lesions without and with atypia (flat epithelial atypia) was analyzed. Cases with architectural atypia (cribriform spaces and/or micropapillae) were excluded from flat epithelial atypia. Calcifications were within the lumen of acini affected by columnar cell lesions in 137 out of 156 biopsies diagnosed with some columnar cell lesions. These represented 37% of vacuum-assisted core biopsies and 62% of low radiological risk (BI-RADS3) calcifications. High-risk (BI-RADS5) calcifications were never associated with columnar cell lesions. Age and menopausal status were comparable in columnar and in not-columnar cell lesions. Atypia was associated with long-term hormone replacement therapy in both lesions. Surgical biopsy was recommended for all cases with atypia. Flat epithelial atypia, as the only histological findings on vacuum-assisted core biopsies, was never associated with malignancy at surgery. In conclusion, we suggest that surgical excision is not mandatory when flat epithelial atypia is found as the most advanced lesion on vacuum-assisted core biopsy performed for low radiological risk calcifications, and that women should be advised of the possible hormone dependency of this entity.


Assuntos
Doenças Mamárias/patologia , Calcinose/patologia , Biópsia , Biópsia por Agulha , Doenças Mamárias/diagnóstico por imagem , Doenças Mamárias/cirurgia , Calcinose/diagnóstico por imagem , Calcinose/cirurgia , Feminino , Humanos , Mamografia , Lesões Pré-Cancerosas/diagnóstico por imagem , Lesões Pré-Cancerosas/patologia , Lesões Pré-Cancerosas/cirurgia , Fatores de Risco
19.
Eur J Radiol ; 114: 57-61, 2019 May.
Artigo em Inglês | MEDLINE | ID: mdl-31005177

RESUMO

OBJECTIVE: To evaluate inter- and intra-rater reliability of background parenchymal enhancement (BPE) assessment across breast MRI sequences. MATERIALS AND METHODS: Institutional review board approval was obtained and the requirement for consent was waived. Three radiologists qualitatively categorized BPE on 150 breast MRI using a four-point scale (minimal, mild, moderate or marked) according to BI-RADS category system. According to MR-sequence used for the assessment of BPE, inter-rater and intra-rater reliability across a simulated reading strategy with four options was performed: (1) initial contrast-enhanced (CE) fat-suppressed T1-weighted images (2) initial CE subtracted images (3) maximum-intensity-projection (MIP) of the first CE subtracted images (4) combination of initial CE fat-suppressed T1-weighted, initial CE subtracted and MIP images. Raters repeated BPE assessment of 45 breast MRI four weeks after the initial assessment. Gwet's AC1 index with ordinal weights was used to assess reliabilities. RESULTS: Gwet's index for the reliability among the three raters was 0.68 (0.63-0.74) using initial contrast-enhanced fat-suppressed T1 weighted images, 0.74 (0.69-0.80) using subtracted images, 0.80 (0.76-0.83) using MIP, 0.80 (0.77-0.84) using a combination of the initial contrast-enhanced fat-suppressed T1 weighted, initial contrast-enhanced subtracted and MIP images. Test-retest reliability was 0.81 (0.60-1.00) for rater 1, 0.77 (0.55-0.98) for rater 2, 0.79 (0.59-0.99) for rater 3 using the combination of initial contrast-enhanced fat-suppressed T1 weighted, initial contrast-enhanced subtracted and MIP images. CONCLUSIONS: Overall, the combination of all CE MRI images showed the highest reliability of BPE assessment. However, MIP showed a high reliability with lower reading time compared to the combination of all CE MRI images.


Assuntos
Carcinoma de Mama in situ/patologia , Neoplasias da Mama/patologia , Carcinoma Ductal de Mama/patologia , Adulto , Idoso , Mama/patologia , Feminino , Humanos , Aumento da Imagem/métodos , Imageamento por Ressonância Magnética/métodos , Pessoa de Meia-Idade , Variações Dependentes do Observador , Reprodutibilidade dos Testes , Estudos Retrospectivos
20.
Eur J Cancer ; 104: 39-46, 2018 11.
Artigo em Inglês | MEDLINE | ID: mdl-30316869

RESUMO

BACKGROUND: Increased risk of breast cancer (BC) and increased risk of an interval BC at mammography screening are associated with high mammographic density. Adjunct imaging detects additional BCs not detected at mammography screening in women with dense breasts. AIM: The aim is to estimate the incremental cancer detection rate (CDR) and false-positive recall for each of tomosynthesis and ultrasound, as adjunct screening modalities in women with mammography-negative dense breasts. METHODS: A multicentre prospective comparative trial of adjunct screening with tomosynthesis or ultrasound in women with mammography-negative dense breasts (ASTOUND-2) recruited asymptomatic women attending Italian breast screening services. All participants had independently interpreted tomosynthesis and ultrasound. Outcomes were ascertained from excision histopathology or completed assessment. Paired binary data were compared using McNemar's test. RESULTS: We recruited 5300 screening participants with median age of 50 (interquartile range 43-79) years who had negative mammography and dense breasts (April 2015-September 2017). Adjunct screening detected 29 additional BCs (27 invasive, 2 in situ): 12 detected on both tomosynthesis and ultrasound, 3 detected only on tomosynthesis, 14 detected only on ultrasound. Incremental CDR for tomosynthesis (+15 cancers) was 2.83/1000 screens (95% confidence interval [CI]: 1.58-4.67) versus ultrasound (+26 cancers) with an incremental CDR of 4.90/1000 screens (95% CI: 3.21-7.19), P = 0.015. Mean size of these cancers was 14.2 mm (standard deviation: 7.8 mm), and six had nodal metastases. Incremental false-positive recall was 1.22% (95% CI: 0.91%-1.49%) and differed significantly between tomosynthesis (0.30%) and ultrasound (1.0%), P < 0.001. CONCLUSIONS: Ultrasound detected more BCs but caused more false positives than tomosynthesis, underscoring trade-offs in screening outcomes when adjunct imaging is used for screening dense breasts.


Assuntos
Densidade da Mama , Neoplasias da Mama/diagnóstico por imagem , Detecção Precoce de Câncer/métodos , Imageamento Tridimensional , Interpretação de Imagem Radiográfica Assistida por Computador , Tomografia Computadorizada por Raios X/métodos , Ultrassonografia Mamária , Adulto , Idoso , Biópsia por Agulha , Neoplasias da Mama/patologia , Reações Falso-Positivas , Feminino , Humanos , Metástase Linfática , Pessoa de Meia-Idade , Estudos Prospectivos , Sensibilidade e Especificidade , Carga Tumoral
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA