Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 9 de 9
Filtrar
Mais filtros

Base de dados
Tipo de documento
Intervalo de ano de publicação
1.
Phys Rev Lett ; 111(12): 125003, 2013 Sep 20.
Artigo em Inglês | MEDLINE | ID: mdl-24093268

RESUMO

Application of lower hybrid (LH) current drive in tokamak plasmas can induce both co- and countercurrent directed changes in toroidal rotation, depending on the core q profile. For discharges with q(0) <1, rotation increments in the countercurrent direction are observed. If the LH-driven current is sufficient to suppress sawteeth and increase q(0) above unity, the core toroidal rotation change is in the cocurrent direction. This change in sign of the rotation increment is consistent with a change in sign of the residual stress (the divergence of which constitutes an intrinsic torque that drives the flow) through its dependence on magnetic shear.

2.
Phys Rev Lett ; 107(26): 265001, 2011 Dec 23.
Artigo em Inglês | MEDLINE | ID: mdl-22243160

RESUMO

Direction reversals of intrinsic toroidal rotation have been observed in diverted Alcator C-Mod Ohmic L-mode plasmas following electron density ramps. For low density discharges, the core rotation is directed cocurrent, and reverses to countercurrent following an increase in the density above a certain threshold. Such reversals occur together with a decrease in density fluctuations with 2 cm(-1)≤k(θ)≤11 cm(-1) and frequencies above 70 kHz. There is a strong correlation between the reversal density and the density at which the Ohmic L-mode energy confinement changes from the linear to the saturated regime.

3.
Phys Rev Lett ; 106(21): 215001, 2011 May 27.
Artigo em Inglês | MEDLINE | ID: mdl-21699305

RESUMO

Intrinsic rotation has been observed in I-mode plasmas from the C-Mod tokamak, and is found to be similar to that in H mode, both in its edge origin and in the scaling with global pressure. Since both plasmas have similar edge ∇T, but completely different edge ∇n, it may be concluded that the drive of the intrinsic rotation is the edge ∇T rather than ∇P. Evidence suggests that the connection between gradients and rotation is the residual stress, and a scaling for the rotation from conversion of free energy to macroscopic flow is calculated.

4.
Rev Sci Instrum ; 92(5): 053508, 2021 May 01.
Artigo em Inglês | MEDLINE | ID: mdl-34243260

RESUMO

Optimized operation of fusion devices demands detailed understanding of plasma transport, a problem that must be addressed with advances in both measurement and data analysis techniques. In this work, we adopt Bayesian inference methods to determine experimental particle transport, leveraging opportunities from high-resolution He-like ion spectra in a tokamak plasma. The Bayesian spectral fitting code is used to analyze resonance (w), forbidden (z), intercombination (x, y), and satellite (k, j) lines of He-like Ca following laser blow-off injections on Alcator C-Mod. This offers powerful transport constraints since these lines depend differently on electron temperature and density, but also differ in their relation to Li-like, He-like, and H-like ion densities, often the dominant Ca charge states over most of the C-Mod plasma radius. Using synthetic diagnostics based on the AURORA package, we demonstrate improved effectiveness of impurity transport inferences when spectroscopic data from a progressively larger number of lines are included.

5.
Rev Sci Instrum ; 83(10): 10E316, 2012 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-23126975

RESUMO

A laser-based (2.55 THz) mulitchord polarimeter is now operational on Alcator C-Mod and is used to make measurements of the internal magnetic field structure as well as plasma fluctuations. The polarimeter is designed to measure the Faraday effect for high-field (up to 8.3 T) and high-density (up to 5 × 10(20) m(-3)) ITER relevant plasma conditions. Initial 3 chord tests are consistent with magnetic equilibrium reconstructions and indicate no measurable contamination from the toroidal magnetic field due to the Cotton-Mouton effect or misalignment. Time response of <1 µs enables the measurement of fast equilibrium temporal dynamics as well as high-frequency fluctuations.

6.
Rev Sci Instrum ; 83(10): 10E325, 2012 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-23126983

RESUMO

Backscattering experiments to detect lower-hybrid (LH) waves have been performed in Alcator C-Mod, using the two modified channels (60 GHz and 75 GHz) of an ordinary-mode reflectometry system with newly developed spectral recorders that can continuously monitor spectral power at a target frequency. The change in the baseline of the spectral recorder during the LH wave injection is highly correlated to the strength of the X-mode non-thermal electron cyclotron emission. In high density plasmas where an anomalous drop in the lower hybrid current drive efficiency is observed, the observed backscattered signals are expected to be generated near the last closed flux surface, demonstrating the presence of LH waves within the plasma. This experimental technique can be useful in identifying spatially localized LH electric fields in the periphery of high-density plasmas.

7.
Rev Sci Instrum ; 81(10): 10D507, 2010 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-21033862

RESUMO

A poloidally viewing far infrared polarimeter diagnostic is being developed for the Alcator C-Mod tokamak, and will be used to determine the q-profile and to study density and magnetic field fluctuations. A three-chord version of what will eventually be up to a ten-chord system has been designed and fabricated and will be installed on C-Mod before the end of the current run period. Bench tests of a single chord mock-up of this system show acceptable noise levels for the planned measurements. We will discuss the analysis and experimental techniques used to diagnose and reduce noise sources.

8.
Rev Sci Instrum ; 79(10): 10E302, 2008 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-19044464

RESUMO

The use of high resolution x-ray crystal spectrometers to diagnose fusion plasmas has been limited by the poor spatial localization associated with chord integrated measurements. Taking advantage of a new x-ray imaging spectrometer concept [M. Bitter et al., Rev. Sci. Instrum. 75, 3660 (2004)], and improvements in x-ray detector technology [Ch. Broennimann et al., J. Synchrotron Radiat. 13, 120 (2006)], a spatially resolving high resolution x-ray spectrometer has been built and installed on the Alcator C-Mod tokamak. This instrument utilizes a spherically bent quartz crystal and a set of two dimensional x-ray detectors arranged in the Johann configuration [H. H. Johann, Z. Phys. 69, 185 (1931)] to image the entire plasma cross section with a spatial resolution of about 1 cm. The spectrometer was designed to measure line emission from H-like and He-like argon in the wavelength range 3.7 and 4.0 A with a resolving power of approximately 10,000 at frame rates up to 200 Hz. Using spectral tomographic techniques [I. Condrea, Phys. Plasmas 11, 2427 (2004)] the line integrated spectra can be inverted to infer profiles of impurity emissivity, velocity, and temperature. From these quantities it is then possible to calculate impurity density and electron temperature profiles. An overview of the instrument, analysis techniques, and example profiles are presented.

9.
Phys Rev Lett ; 91(20): 205003, 2003 Nov 14.
Artigo em Inglês | MEDLINE | ID: mdl-14683369

RESUMO

Anomalous momentum transport has been observed in Alcator C-Mod tokamak plasmas through analysis of the time evolution of core impurity toroidal rotation velocity profiles. Following the L-mode to EDA (enhanced D(alpha)) H-mode transition, the ensuing cocurrent toroidal rotation velocity, which is generated in the absence of any external momentum source, is observed to propagate in from the edge plasma to the core. The steady state toroidal rotation velocity profiles are relatively flat and the momentum transport can be simulated with a simple diffusion model. Velocity profiles during edge localized mode free (ELM-free) H-modes are centrally peaked, which suggests the addition of inward momentum convection. In all operating regimes the observed momentum diffusivities are much larger than the neoclassical values.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA