RESUMO
The newly operating near-backscattering imaging (NBI) system on the Laser MegaJoule (LMJ) is briefly described with emphasis on the temporally resolved measurements and their synchronization with the LMJ laser pulse through target shots taken as part of the diagnostic commissioning campaign. The NBI measures the stimulated Brillouin and Raman scattered light around two quadruplets (one inner and one outer) of the upper LMJ hemisphere. The temporal resolution is achieved with a unique system: a specifically designed wide-open optical lens images 40 points of a diffuser onto an array of optical fibers with the scattered light recorded on a multiplexed photodiode array.
RESUMO
The diagnostic designs for the Laser Megajoule (LMJ) will require components to operate in environments far more severe than those encountered in present facilities. This harsh environment will be induced by fluxes of neutrons, gamma rays, energetic ions, electromagnetic radiations, and, in some cases, debris and shrapnel, at levels several orders of magnitude higher than those experienced today on existing facilities. The lessons learned about the vulnerabilities of present diagnostic parts fielded mainly on OMEGA for many years, have been very useful guide for the design of future LMJ diagnostics. The present and future LMJ diagnostic designs including this vulnerability approach and their main mitigation techniques will be presented together with the main characteristics of the LMJ facility that provide for diagnostic protection.