Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 18 de 18
Filtrar
1.
J Card Surg ; 37(1): 107-114, 2022 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-34662451

RESUMO

BACKGROUND AND AIM OF THE STUDY: To report early clinical outcomes of the frozen elephant trunk (FET) technique for the treatment of complex aortic diseases after transition from conventional elephant trunk. METHODS: A single-center, retrospective study of patients who underwent hybrid aortic arch and FET repair for aortic arch and/or proximal descending aortic aneurysms, acute and chronic Stanford type A aortic dissection with arch and/or proximal descending involvement, Stanford type B acute and chronic aortic dissections with retrograde aortic arch involvement. RESULTS: Between December 2017 and May 2020, 70 consecutive patients (62.7 ± 10.6 years, 59 male) were treated: 41 (58.6%) for emergent conditions and 29 (41.4%) for elective. Technical success was 100%. In-hospital mortality was 14.2% (n = 12, 17.1% emergent vs. 10.3% elective, P = NS); 2 (2.9%) major strokes; 1 (1.4%) spinal cord injury. Mean follow-up was 12.5 months (interquartile range, 3.7-22.3). Overall survival at 3, 6, 12, and 24 months was 90% (95% confidence interval [CI], 83.2-97.3), 85.6% (95% CI, 77.7-94.3), 79.1% (95% CI, 69.9-89.5), 75.6% (95% CI, 65.8-86.9) and 73.5% (95% CI, 63.3-85.3). There were no aortic re-interventions and no distal stent graft-induced new entry (dSINE); 5 patients with residual type B dissection underwent TEVAR completion. CONCLUSIONS: In a real-world setting, FET with Thoraflex Hybrid demonstrated feasibility and good clinical outcomes, even in emergent setting. Our implant technique optimize cerebral perfusion reporting good results in terms of neurological complications. Techniques to perfect the procedure and to reduce remaining risks, and consensus on considerations such as standardized cerebral protection need to be reported.


Assuntos
Aneurisma da Aorta Torácica , Dissecção Aórtica , Implante de Prótese Vascular , Dissecção Aórtica/diagnóstico por imagem , Dissecção Aórtica/cirurgia , Aorta Torácica/diagnóstico por imagem , Aorta Torácica/cirurgia , Aneurisma da Aorta Torácica/cirurgia , Prótese Vascular , Humanos , Masculino , Estudos Retrospectivos
2.
J Card Surg ; 36(1): 371-373, 2021 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-33225461

RESUMO

Reimplantation of the supra-aortic vessels can be challenging with Thoraflex Hybrid. A device modification made the vessel lengths more appropriate and the position of the neo-vessels in the chest avoided malpositioning and kinking and facilitated sternum closure; this may improve operating times as well as allowing complete and continuous cerebral trivascular perfusion and corrects positioning of the intrathoracic vessels.


Assuntos
Aneurisma da Aorta Torácica , Dissecção Aórtica , Implante de Prótese Vascular , Anastomose Cirúrgica , Dissecção Aórtica/cirurgia , Aorta Torácica/diagnóstico por imagem , Aorta Torácica/cirurgia , Aneurisma da Aorta Torácica/diagnóstico por imagem , Aneurisma da Aorta Torácica/cirurgia , Prótese Vascular , Humanos
3.
Medicina (Kaunas) ; 57(9)2021 Aug 28.
Artigo em Inglês | MEDLINE | ID: mdl-34577818

RESUMO

Acute type A aortic dissection (ATAAD) is an indisputable emergency with very poor outcomes without surgical treatment. Although the aortic arch is often involved in the aortic dissection, its optimal management during surgical therapy remains uncertain. A conservative tear-oriented approach has traditionally been adopted, limiting the procedure to the ascending aorta (or hemiarch) replacement. However, dilation of the residual dissected aorta and subsequent rupture may occur, requiring further intervention in the future. In the last two decades, the frozen elephant trunk (FET) technique has become a valid and attractive option to treat aortic disease when the arch and the thoracic aorta are involved, both in elective and in emergency settings. Here, we report a review of the contemporary literature regarding the short- and long-term outcomes of the FET technique in ATAAD repair.


Assuntos
Aneurisma da Aorta Torácica , Dissecção Aórtica , Implante de Prótese Vascular , Doença Aguda , Dissecção Aórtica/diagnóstico por imagem , Dissecção Aórtica/cirurgia , Aneurisma da Aorta Torácica/diagnóstico por imagem , Aneurisma da Aorta Torácica/cirurgia , Humanos , Estudos Retrospectivos
4.
J Card Surg ; 35(11): 3157-3159, 2020 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-32720389

RESUMO

BACKGROUND: Displacement of Impella 5.0 secondary to patient movement or transportation is a well-known complication. Typically, repositioning of an Impella across the aortic valve is attempted over a guidewire. We present the first case, to our knowledge, of repositioning a dislodged Impella 5.0 without a guidewire under transesophageal echocardiography (TEE) guidance, by inducing rapid ventricular pacing to cross the aortic valve. CASE PRESENTATION: A 70-year-old man with low left ventricular ejection fraction underwent off-pump coronary artery bypass grafting. On 2nd postoperative day a low cardiac output state developed with increasing lactate levels and consequently the patient was taken to the cardiac catheterization laboratory for insertion of an Impella 5.0. Suddenly the Impella system failed with a rapid hemodynamic deterioration and it was successfully bedside repositioned inducing rapid ventricular pacing. CONCLUSIONS: In case of accidental Impella dislodgement and fast deterioration of the patient's hemodynamic status, rapid pacing may be an option to "open" the aortic valve thus aiding quick replacement of Impella 5.0 through the aortic valve into the left ventricle under TEE guidance.


Assuntos
Valva Aórtica/cirurgia , Estimulação Cardíaca Artificial/métodos , Coração Auxiliar/efeitos adversos , Falha de Prótese , Implantação de Prótese/métodos , Cirurgia Assistida por Computador/métodos , Idoso , Ponte de Artéria Coronária sem Circulação Extracorpórea , Ecocardiografia Transesofagiana , Ventrículos do Coração/cirurgia , Hemodinâmica , Humanos , Masculino , Reoperação
5.
J Card Surg ; 28(5): 557-60, 2013 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-23947575

RESUMO

We report the case of a 46-year-old male hospitalized for abdominal pain and fever with history of a David procedure followed by an aortic valve replacement due to severe aortic regurgitation. Transesophageal echocardiography (TEE) and computed tomography showed a large mass floating in the aorta. After surgical excision of the vegetation, attached to the Dacron prosthesis, histological examination revealed Candida hyphae and spores confirming the diagnosis of a mycetoma in an ascending aorta tubular graft. At six-month follow-up, the patient was in good clinical condition without recurrence of the fungal mass on TEE.


Assuntos
Aorta/diagnóstico por imagem , Aorta/microbiologia , Implante de Prótese Vascular/métodos , Prótese Vascular/microbiologia , Candida/isolamento & purificação , Micetoma/microbiologia , Micetoma/cirurgia , Infecções Relacionadas à Prótese/microbiologia , Infecções Relacionadas à Prótese/cirurgia , Valva Aórtica/cirurgia , Insuficiência da Valva Aórtica/cirurgia , Ecocardiografia Transesofagiana , Seguimentos , Implante de Prótese de Valva Cardíaca , Humanos , Masculino , Micetoma/diagnóstico por imagem , Infecções Relacionadas à Prótese/diagnóstico por imagem , Índice de Gravidade de Doença , Resultado do Tratamento
6.
Front Cardiovasc Med ; 9: 997961, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-36312248

RESUMO

Introduction: In the last two decades, a more aggressive approach has been encouraged to treat patients with acute type A aortic dissection (ATAAD), extending the repair to the aortic arch and proximal descending thoracic aorta with the frozen elephant trunk (FET) implantation. Here, we report our single-centre experience with the FET technique for the systematic treatment of emergency type A aortic dissection. Materials and methods: Between December 2017 and January 2022, 69 consecutive patients were admitted with ATAAD; of those, 66 patients (62.9 ± 10.2 years of age, 81.8% men) underwent emergency hybrid aortic arch and FET repair with the multibranched Thoraflex hybrid graft and were enrolled in the study. Primary endpoints were 30 days- and in-hospital mortality. Secondary endpoints were postoperative morbidity and follow-up survival. To better clarify the impact of age on surgical outcomes, we have divided the study population into two groups: group A for patients <70 years of age (47 patients), and group B for patients ≥70 years (19 patients). Time-to-event analysis has been conducted using the Log-rank test and is displayed with Kaplan-Meier curves. A multiple Cox proportional Hazard model was developed to identify predictors of long-term survival with a stepwise backward/forward selection process. Results: 30-days- and in-hospital mortality were 10.6 and 13.6%, respectively. Stroke occurred in three (4.5%) patients. Two (3.0%) patients experienced spinal cord ischemia. We did not find any statistically significant difference between the two groups in terms of main post-operative outcomes. The multivariable Cox proportional hazard model showed left ventricular ejection fraction (HR: 0.83, 95% CI: 0.79-0.92, p < 0.01), peripheral vascular disease (HR: 15.8, 95% CI: 3.9-62.9, p < 0.01), coronary malperfusion (HR: 0.10, 95% CI: 0.01-0.77, p =0.03), lower limbs malperfusion (HR: 5.1, 95% CI: 1.10-23.4, p = 0.04), and cardiopulmonary bypass time (HR: 1.02, 95% CI: 1-1.04, p = 0.01) as independent predictors of long term mortality. Conclusions: Frozen elephant trunk repair to treat emergency type A aortic dissection appears to be associated with good early and mid-term clinical outcomes even in the elderly.

7.
Cardiovasc Diagn Ther ; 12(4): 516-520, 2022 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-36033221

RESUMO

The frozen elephant trunk (FET) technique is an increasingly common procedure to treat complex extensive aortic disease both in elective and emergency setting. In a contemporary era, several prostheses are available to be used by surgeons performing such procedures, merging the advantages of endovascular and conventional surgery and preparing a more useful landing zone for second-stage downstream endovascular or open repair. Thoraflex hybrid (Terumo Aortic, Scotland) is a largely used hybrid vascular device merging a conventional surgical vascular graft made of gelatin-sealed woven polyester graft with a nitinol self-expanding stent graft. Since its release in 2012, this prosthesis has gained a large consensus, mainly for the plexus version, which allows for single reimplantation of the epiaortic vessels. In the last few years, new devices have come out to offer new specific weapons to be used by the surgical team in different clinical scenarios. In this context, the need of making the supra-aortic vessel debranching easier and more functional to our surgical technique has pushed our demand for a customization of a conventional Thoraflex hybrid. Here we report a modification to its standard design, the concept beyond the "Custom device" and its potential advantages with regards to our peculiar implantation technique and intraoperative cerebral perfusion during circulatory arrest time.

8.
Clin Case Rep ; 9(9): e04688, 2021 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-34484752

RESUMO

Difficult diagnosis is due to rarity of the case. TT or TE echocardiography is sufficient to make a correct diagnosis. The risk of embolism or coronary ostia occlusion should guide the decision for surgery.

9.
JACC Case Rep ; 3(6): 884-887, 2021 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-34317647

RESUMO

We report a unique case of a Starr-Edwards prosthesis (model 6310, cloth covered) implanted in the mitral position by Christian Barnard that was successfully explanted and replaced after 50 years, the longest period free from valve dysfunction ever reported. Reoperation also included replacement of the native aortic valve combined with tricuspid valve annuloplasty. (Level of Difficulty: Beginner.).

10.
Gen Thorac Cardiovasc Surg ; 69(5): 877-881, 2021 May.
Artigo em Inglês | MEDLINE | ID: mdl-33400196

RESUMO

Short-term mechanical circulatory support (MCS) devices are designed to provide hemodynamic support for a wide range of clinical conditions such as high-risk cardiac surgery or interventional procedures, post-cardiotomy cardiogenic shock, acute decompensated heart failure. Electrical storm (defined as three or more sustained episodes of ventricular fibrillation-VF- in a 24-h period) is a rare but critical complication following revascularization in patients with ischemic heart disease and it is associated with a very high mortality (80-90%) both during the incident alone and during further observation. Here we report the case of a 38-year-old patient affected by coronary artery disease with moderate to severe left ventricular systolic dysfunction (EF 30-35%) who underwent emergency coronary artery bypass grafting (CABG) complicated by electrical storm and severe haemodynamic instability, successfully managed with a novel approach of biventricular mechanical circulatory support with extracorporeal life support (ECLS) in first instance, subsequently switched to Impella CP and ProtekDuo.


Assuntos
Procedimentos Cirúrgicos Cardíacos , Oxigenação por Membrana Extracorpórea , Insuficiência Cardíaca , Coração Auxiliar , Adulto , Humanos , Choque Cardiogênico/etiologia , Choque Cardiogênico/terapia
11.
World J Surg ; 34(4): 652-7, 2010 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-20012609

RESUMO

OBJECTIVES: Granulocyte apoptosis is a key control process in the clearance of neutrophils from inflammatory sites, and its rate is modulated by a number of inflammatory mediators. In this study, we investigated whether the use of left ventricular-assisted technique (LVA) in beating heart myocardial revascularization would exert less impact on neutrophil apoptosis compared with conventional cardiopulmonary bypass (CPB). METHODS: Forty consecutive patients who underwent myocardial revascularization were randomly assigned to LVA (group A, 21 patients) or CPB (group B, 19 patients). Blood samples for detection of interleukin-6, interleukin-8, and tumor necrosis factor-alpha were measured at baseline and at various time points postoperatively. Neutrophil apoptosis was detected by light microscopy as well as by the annexin-V assays together with the activity of caspase 3 on postoperative samples. RESULTS: Preoperative clinical and demographic data did not differ between the two groups. The two groups also were similar with respect to mortality, number of grafts performed, duration of extracorporeal circulation, and need for inotropes. However postoperatively, spontaneous apoptosis was significantly delayed in neutrophils from CPB patients compared with LVA patients. Neutrophils were activated, as indicated by increased surface expression of CD11b. Caspase 3 activity was found to be significantly reduced in neutrophils from CPB patients after 18 and 24 hours of culture. CONCLUSIONS: Patients who underwent beating heart myocardial revascularization with LVA show a better preserved neutrophil apoptosis than patients treated with the CPB.


Assuntos
Apoptose/fisiologia , Coração Auxiliar , Isquemia Miocárdica/cirurgia , Revascularização Miocárdica/métodos , Idoso , Análise de Variância , Anexina A5/sangue , Ponte Cardiopulmonar/métodos , Caspase 3/sangue , Distribuição de Qui-Quadrado , Feminino , Humanos , Interleucina-6/sangue , Interleucina-8/sangue , Masculino , Pessoa de Meia-Idade , Isquemia Miocárdica/sangue , Isquemia Miocárdica/fisiopatologia , Neutrófilos/fisiologia , Estudos Prospectivos , Estatísticas não Paramétricas , Resultado do Tratamento , Fator de Necrose Tumoral alfa/sangue
12.
Aorta (Stamford) ; 8(4): 111-115, 2020 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-33307592

RESUMO

Type A aortic dissection, according to Stanford classification, is a surgical emergency with high morbidity and carries 56% of in-hospital mortality when surgical intervention is not performed. The surgical mortality at 30 days is 10 to 20%. The therapeutic goals are to replace the diseased ascending aorta and to treat or to monitor the distal aortic patent false lumen. When the dissection involves the aortic root and the architecture of aortic valve is normal, the surgical techniques used could be multiple: reinforce the aortic root and spare the native aortic valve or replace the aortic valve and the aortic root. The Florida sleeve technique has been developed to treat the aortic aneurysm, sparing the aortic valve in patients with connective tissue disease. Some case reports have described the use of this technique to treat an acute aortic dissection. In the following case, we present a single stage repair of the ascending aorta, aortic arch, and proximal intrathoracic aorta in a patient with Type A aortic dissection through the contemporaneous use of two techniques: Florida sleeve and Vascutek "Thoraflex" hybrid prosthesis. The use of these two techniques allows the repair/replacement of the proximal intrathoracic aorta, the sparing of the native aortic valve, the employment of a hybrid prosthesis to replace the supraortic vessels, and the creation of a descending aortic landing zone for later, distal intervention.

13.
PLoS One ; 14(11): e0223710, 2019.
Artigo em Inglês | MEDLINE | ID: mdl-31738753

RESUMO

BACKGROUND: To evaluate the prognostic impact of diabetes mellitus (DM) in patients with Infective Endocarditis (IE). METHODS AND RESULTS: 375 patients with diagnosis of IE referred to our Hospital between 1994-2017 were retrospectively included; diabetes was reported in 129 (34.4%). Diabetic patients were older than non-diabetic (66±1 vs. 57±2 years, p<0.001) and showed a higher prevalence of comorbidities such as hypertension (75 vs. 54%, p<0.001), coronary artery disease (30 vs. 12%, p<0.001) and history of heart failure (HF; 24 vs. 13%, p = 0.021). Echocardiography showed a higher incidence of paravalvular complications (82 vs. 64%, p<0.001) and a lower left ventricular ejection fraction (LVEF; 52±11 vs. 55±10%, p = 0.001) in diabetic than in non-diabetic patients. In-hospital mortality was higher in diabetic patients (83 vs. 74%; p = 0.030). At logistic regression, history of HF (OR = 3.1, 95%CI: 1.87-5.29, p<0.001) resulted an independent predictor of in-hospital death. At long-term follow-up [median 24(7-84) months], the Kaplan-Meier analysis showed a significantly lower survival free from all-cause death in the group with diabetes (Log-rank<0.001). At the propensity score adjusted Cox multivariable analysis, DM (HR = 1.76, 95%CI: 1.18-2.6, p = 0.005), age (HR = 1.03, 95%CI: 1.02-1.05, p<0.001), intravenous drug users (HR = 5.42, 95%CI: 2.55-11.51, p<0.001) and low LVEF (HR = 0.98, 95%CI: 0.96-0.99, p = 0.013) were independently associated to a higher mortality. CONCLUSION: In patients with IE, DM is associated to a higher prevalence of anatomic complications and a more impaired LVEF. Diabetic patients show a significantly lower survival both in hospital and during follow-up compared to the non-diabetic ones.


Assuntos
Complicações do Diabetes/epidemiologia , Endocardite/complicações , Adulto , Idoso , Comorbidade , Complicações do Diabetes/mortalidade , Complicações do Diabetes/fisiopatologia , Endocardite/epidemiologia , Endocardite/mortalidade , Feminino , Mortalidade Hospitalar , Humanos , Itália/epidemiologia , Estimativa de Kaplan-Meier , Masculino , Pessoa de Meia-Idade , Prevalência , Prognóstico , Estudos Retrospectivos , Função Ventricular Esquerda
14.
Int J Cardiol ; 284: 50-58, 2019 06 01.
Artigo em Inglês | MEDLINE | ID: mdl-30360995

RESUMO

BACKGROUND: The prognostic predictors of outcome in patients with functional mitral regurgitation (FMR) undergoing MitraClip implantation (MCi) are still poorly known. The aim of our study is to identify the baseline predictors of outcome in FMR patients candidate to MCi. METHODS: All patients with symptomatic moderate-to-severe or severe FMR undergoing MCi at our institution were consecutively and prospectively enrolled. Baseline clinical and instrumental data were collected. Primary endpoint was the occurrence of cardiac death; secondary endpoints were all-cause death and the composite of cardiac death or rehospitalization for heart failure. RESULTS: 74 patients (mean 71.6 ±â€¯8.3 years) were enrolled. During follow-up (median 416.0 days), the primary endpoint occurred in 15 (20.3%), all-cause death in 26 (35.1%) and the composite endpoint in 25 (33.8%). At multivariate analysis, the left atrial volume index (LAVi; HR:1.02; P = 0.048) and the low peak oxygen uptake (peak VO2; HR:0.73; P = 0.018) increased the risk of cardiac death at follow-up; atrial fibrillation (AF; HR:2.69; P = 0.027) was independently associated to all-cause death and the low level of peak VO2 was an independent predictor of overall mortality (HR:0.70; P < 0.001) as well as of the composite endpoint (HR:0.73; P < 0.001). The ROC analysis identified a peak VO2 cut-off of 10.0 mL/kg/min as the best predictor for the three study endpoints; the best LAVi cut-off for cardiac death was 67 mL/m2. Kaplan-Meier analysis for the individual and combined outcome predictors confirmed their significant stratification ability during follow-up. CONCLUSIONS: Peak VO2, along with LAVi and AF, identify FMR patients with the worst prognosis after MCi.


Assuntos
Insuficiência Cardíaca/complicações , Implante de Prótese de Valva Cardíaca/métodos , Insuficiência da Valva Mitral/etiologia , Valva Mitral/cirurgia , Medição de Risco/métodos , Idoso , Progressão da Doença , Ecocardiografia , Feminino , Seguimentos , Insuficiência Cardíaca/epidemiologia , Insuficiência Cardíaca/fisiopatologia , Humanos , Incidência , Itália/epidemiologia , Masculino , Valva Mitral/diagnóstico por imagem , Insuficiência da Valva Mitral/diagnóstico , Insuficiência da Valva Mitral/cirurgia , Prognóstico , Estudos Prospectivos , Desenho de Prótese , Fatores de Risco , Índice de Gravidade de Doença , Taxa de Sobrevida/tendências , Resultado do Tratamento , Função Ventricular Esquerda/fisiologia
15.
Eur Heart J Acute Cardiovasc Care ; 6(7): 666-669, 2017 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-26566773

RESUMO

Spontaneous coronary artery rupture is a rare disorder that may develop early into a sudden death due to the abrupt evolution of the associated cardiac tamponade. In some cases the rupture is contained and a false aneurysm develops with slower evolution of clinical signs. The correct diagnosis of spontaneous coronary artery rupture deserves a high level of suspicion; frequently it may be missed because the time window of its evolution seems to be very short or signs of acute coronary syndrome sometimes can prevail, leading to delays in diagnosis or to misdiagnosis. We report the case of a patient presenting a giant pseudoaneurysm of the right coronary artery due to spontaneous coronary artery rupture without any underlying disease. Moreover we present a review of the few cases in the literature, offering a pathophysiological hypothesis linking the site of rupture and clinical presentation.


Assuntos
Síndrome Coronariana Aguda/diagnóstico , Falso Aneurisma/complicações , Tamponamento Cardíaco/complicações , Aneurisma Coronário/complicações , Vasos Coronários/diagnóstico por imagem , Síndrome Coronariana Aguda/etiologia , Síndrome Coronariana Aguda/cirurgia , Adulto , Falso Aneurisma/diagnóstico , Procedimentos Cirúrgicos Cardíacos , Tamponamento Cardíaco/diagnóstico , Tamponamento Cardíaco/cirurgia , Angiografia por Tomografia Computadorizada , Aneurisma Coronário/diagnóstico , Aneurisma Coronário/cirurgia , Angiografia Coronária , Ecocardiografia Transesofagiana , Eletrocardiografia , Humanos , Masculino , Ruptura Espontânea
16.
J Cardiovasc Med (Hagerstown) ; 18(9): 669-678, 2017 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-28509760

RESUMO

AIM: The aim of this study was to assess preoperative determinants, prevalence, and prognostic impact of left ventricular (LV) reverse remodeling (LVRR) in patients with secondary mitral regurgitation (SMR), undergoing MitraClip implantation (MCi). METHODS: From March 2012 to January 2015, a total of 41 consecutive patients with moderate-to-severe SMR treated successfully with MCi were enrolled. All patients underwent clinical and echocardiographic follow-up after MCi. Global longitudinal strain (GLS) was obtained using two dimensional speckle tracking analysis. A reduction in LV end-systolic volume more than 10% compared with baseline was considered as a marker of LVRR. Patients were divided into two groups according to the presence or absence of LVRR. Cardiac events were defined as the occurrence of cardiac death, rehospitalization for worsening heart failure, and mitral valve surgery. RESULTS: On univariable analysis, EuroSCORE II and GLS were associated with LVRR. On multivariable logistic regression analysis, GLS was the only independent correlate of LVRR (P = 0.004). A receiver operating characteristic curve identified a cutoff value for GLS of -9.25% (P < 0.001) associated with LVRR, with a sensitivity and specificity of 81 and 74%, respectively. New York Heart Failure Association class more than 2 after MCi, absence of LVRR after MCi, and preoperative GLS more than -9.25% were significantly correlated with adverse cardiac events at long-term follow-up. On multivariable logistic regression analysis, GLS was the only independent predictor of composite adverse cardiac events at 2-year follow-up. CONCLUSION: A worse preoperative GLS predicts no LVRR and is associated with adverse long-term outcome after successful MCi for SMR.


Assuntos
Ecocardiografia/métodos , Insuficiência da Valva Mitral/diagnóstico por imagem , Idoso , Idoso de 80 Anos ou mais , Feminino , Implante de Prótese de Valva Cardíaca , Humanos , Masculino , Pessoa de Meia-Idade , Insuficiência da Valva Mitral/terapia , Remodelação Ventricular
SELEÇÃO DE REFERÊNCIAS