Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros

Base de dados
Tipo de documento
Ano de publicação
Intervalo de ano de publicação
1.
Methods Cell Biol ; 186: 51-90, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38705606

RESUMO

Technological advancements in fluorescence flow cytometry and an ever-expanding understanding of the complexity of the immune system, have led to the development of large flow cytometry panels, reaching up to 40 markers at the single-cell level. Full spectrum flow cytometry, that measures the full emission range of all the fluorophores present in the panel instead of only the emission peaks is now routinely used in many laboratories internationally, and the demand for this technology is rapidly increasing. With the capacity to use larger and more complex staining panels, optimized protocols are required for the best panel design, panel validation and high-dimensional data analysis outcomes. In addition, for ex vivo experiments, tissue preparation methods for single-cell analysis should also be optimized to ensure that samples are of the highest quality and are truly representative of tissues in situ. Here we provide optimized step-by-step protocols for full spectrum flow cytometry panel design, tissue digestion and panel optimization to facilitate the analysis of challenging tissue types.


Assuntos
Citometria de Fluxo , Imunofenotipagem , Citometria de Fluxo/métodos , Imunofenotipagem/métodos , Humanos , Análise de Célula Única/métodos , Coloração e Rotulagem/métodos , Corantes Fluorescentes/química , Animais
2.
Physiol Rep ; 12(1): e15891, 2024 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-38163669

RESUMO

Cardiovascular rhythms representing functional states of the autonomic nervous system (ANS) are insufficiently reflected by the current physiological model based on low and high frequency bands (LF, HF, resp.). An intermediate (IM) frequency band generated by a brainstem pacemaker was included in systemic physiological ANS analyses of forehead skin perfusion (SP), ECG, and respiration. Data of 38 healthy participants at T0 and T1 (+1 week) before, during, and following osteopathic cranial vault hold (CVH) stimulation were analyzed including momentary frequencies of highest amplitude, amplitudes in low (0.05-0.12 Hz), IM (0.12-0.18 Hz), and high (0.18-0.4 Hz) frequency bands, and established heart rate variability (HRV) metrics. During CVH, LF interval durations increased, whereas IM/HF band durations decreased significantly. Amplitudes increased significantly in all frequency bands. A cluster analysis found one response pattern dominated by IM activity (47% of participants) with highly stable 0.08 Hz oscillation to CVH, and one dominated by LF activity (0.10 Hz) at T0, increasing to IM activity at T1. Showing frequency ratios at ≈3:1, respiration was not responsible for oscillations in PPG during CVH. HRV revealed no significant responses. Rhythmic patterns in SP and respiration matched previous findings on a reticular "0.15 Hz rhythm". Involvement of baroreflex pathways is discussed as alternative explanation.


Assuntos
Sistema Nervoso Autônomo , Sistema Cardiovascular , Humanos , Pressão Sanguínea/fisiologia , Sistema Nervoso Autônomo/fisiologia , Respiração , Barorreflexo , Frequência Cardíaca/fisiologia
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA