Resultados 1 - 20 de 25
Filtrar
1.
Eur Radiol ; 30(1): 404-412, 2020 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-31332560

RESUMO

OBJECTIVES: To develop a method that allows approximating the mass of monosodium uric acid (MSU) in a gouty tophus using phantom measurements and including tophus density into the calculation of the dual-energy computed tomography (DECT) tophus volumetry. METHODS: We prepared specimens of different concentrations of MSU placed in an epoxy-based phantom and an excised porcine foreleg. Density and volumetric measurements were performed in sequential single-source DECT scans acquired with increasingly higher tube currents. We developed a method for estimating the tophus mass by multiplying the detected tophus volume with its mean density and adding a specific gravimetric coefficient k. k was derived from the DECT scans by comparing the approximated MSU masses in the epoxy phantom with the known true MSU masses of the specimens. RESULTS: Comparison of the approximated MSU masses in the porcine foreleg scans with the true MSU masses of the syringe contents showed similar performance to sole volume measurement while providing additional information on the true uric acid burden: Over 70% of the true urate masses have been detected in MSU concentrations ≥ 45%, while the detection rate was much lower for MSU concentrations ≤ 40%. Retrospective analysis of patients with proven gouty arthritis confirmed the diagnostic potential of the mass approximation technique. CONCLUSIONS: We successfully established a method to include tophus density measurement for estimation of the uric acid burden in milligrams (instead of ml) in a phantom setting for MSU concentrations above 40%. Future studies should validate its use for follow-up in clinical practice. KEY POINTS: • Including tophus density measurement in dual-energy computed tomography scans in a phantom setting can be used for estimating the urate burden in milligrams, which might be useful for imaging follow-up. • The mass [mg] of the uric acid burden in a patient with gouty arthritis can be calculated by multiplying volume [ml] with mean density [HU] using a specific gravimetric coefficient. • Retrospective analysis of two patients with gouty tophi showed the relevance of measuring urate mass in addition to urate volume alone.


Assuntos
Artrite Gotosa/diagnóstico por imagem , Imagem Radiográfica a Partir de Emissão de Duplo Fóton/métodos , Tomografia Computadorizada por Raios X/métodos , Ácido Úrico/análise , Algoritmos , Animais , Artrite Gotosa/metabolismo , Humanos , Masculino , Imagens de Fantasmas , Estudos Retrospectivos , Suínos
2.
J Comput Assist Tomogr ; 44(5): 744-749, 2020.
Artigo em Inglês | MEDLINE | ID: mdl-32842063

RESUMO

PURPOSE: The aim of this study was to investigate the diagnostic accuracy of computed tomography (CT) for the prediction of ablation zones from microwave ablation (MWA) and cryoablation (CA) in an ex vivo porcine liver model. METHODS: Sequential (30 seconds) CT scans were acquired during and after MWA and CA in an ex vivo porcine liver model. We generated 120-kVp equivalent reconstructions of generic dual-energy CT data sets, and comprehensive region-of-interest measurements were statistically correlated with invasive temperature monitoring using Pearson correlation coefficient. Binary logistic regression was performed for prediction of successful ablation. RESULTS: With the use of pooled data from 6 lesions in 2 separate experiments, correlation analysis of attenuation in Hounsfield units (HU) and temperature yielded r = -0.79 [confidence interval (CI), -0.85 to -0.71] for MWA and r = 0.62 (CI, 0.55 to 0.67) for CA.For MWA, there was a linear association between attenuation and temperature up to 75°C; thus, linear regression yielded a slope of -2.00 HU/°C (95% CI, -1.58 to -2.41). For CA, a linear association between attenuation and temperature was observed in the cooling phase with a slope of 2.11 HU/°C (95% CI, 1.79 to 2.58). In MWA treatment, binary logistic regression separated less than 70°C and greater than 70°C with 89.2% accuracy. Within the ice ball, temperatures above and below -20°C were distinguished with 65.3% accuracy. CONCLUSIONS: Our experiments reveal several difficulties in predicting ablation zone temperature from CT attenuation. Microwave ablation leads to gas production in the tissue, which degrades the accuracy of noninvasive temperature measurement, especially at higher temperatures. In CA, CT thermometry is limited by ice ball formation, which leads to homogeneous attenuation, nearly independent of temperature. Further research is needed to define the role of CT thermography in ablation zone monitoring in liver malignancies.


Assuntos
Técnicas de Ablação/métodos , Termografia/métodos , Tomografia Computadorizada por Raios X/métodos , Animais , Criocirurgia , Fígado/diagnóstico por imagem , Fígado/cirurgia , Micro-Ondas , Suínos
3.
Eur Radiol ; 29(1): 31-39, 2019 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-29948088

RESUMO

OBJECTIVES: To evaluate the diagnostic accuracy of single-source dual-energy computed tomography (DECT) for the detection of bone marrow oedema (BME) in patients with vertebral compression fractures. METHODS: Patients over 50 years of age with radiographically suspected vertebral compression fracture of the thoracic or lumbar spine were prospectively enrolled. All patients underwent DECT with sequential acquisition of 80 and 135 kVp datasets on a 320-row detector CT scanner and 1.5-Tesla magnetic resonance imaging (MRI) including T1-weighted and short-tau inversion recovery (STIR) sequences. Virtual non-calcium (VNCa) images were reconstructed using a three-material decomposition algorithm. Vertebrae with height loss in CT were scored for the presence of BME in both MRI and DECT and used to determine signal- and contrast-to-noise ratios (SNR and CNR). Contingency analysis using MRI as standard of reference and Fleiss's kappa were calculated. IRB approval was obtained. RESULTS: In total 192 vertebral compression fractures in 70 patients (23 men, 47 women; mean age 70.7 years (SD 9.8)) were included in our analysis. DECT showed a reader-dependent sensitivity of 72% and specificity of 70% for BME. Fleiss's kappa was .40 for DECT and .58 for MRI. T1-weighted images had significantly better SNR and CNR compared to STIR, CT, and VNCa (p < .0001); however, there was no difference between STIR and VNCa. CONCLUSIONS: VNCa images depict BME with adequate sensitivity and specificity and can be acquired on a single-source system. Image quality is adequate but trained readers are needed for image interpretation. KEY POINTS: • Dual-energy CT in a single-source technique can help to detect bone marrow oedema in patients with vertebral compression fractures. • However, given the inferior inter-rater reliability and limited specificity compared to MRI, experienced readers are needed for image interpretation. • Dual-energy CT of the spine has limited sensitivity for the detection of bone marrow oedema in vertebra with previous surgical intervention.


Assuntos
Doenças da Medula Óssea/diagnóstico , Medula Óssea/diagnóstico por imagem , Edema/diagnóstico , Fraturas por Compressão/diagnóstico , Vértebras Lombares/lesões , Fraturas da Coluna Vertebral/diagnóstico , Tomografia Computadorizada por Raios X/métodos , Idoso , Idoso de 80 Anos ou mais , Algoritmos , Doenças da Medula Óssea/etiologia , Edema/etiologia , Feminino , Fraturas por Compressão/complicações , Humanos , Vértebras Lombares/diagnóstico por imagem , Imageamento por Ressonância Magnética/métodos , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos , Curva ROC , Reprodutibilidade dos Testes , Fraturas da Coluna Vertebral/complicações
4.
Clin Exp Rheumatol ; 36(6): 1061-1067, 2018.
Artigo em Inglês | MEDLINE | ID: mdl-30418110

RESUMO

OBJECTIVES: To validate the diagnostic benefit of dual-energy computed tomography (DECT) and synovial fluid aspiration in suspected gout. METHODS: A total of 43 patients with suspected gout underwent aspiration and DECT (320-row CT; Canon Medical Systems, Japan). The patients were assessed (gout vs. non-gout) based on the 2015 ACR/EULAR gout classification criteria using clinical and laboratory findings. The results were analysed by comparing two scenarios using McNemar test: Scenario A: ACR/EULAR criteria, followed by DECT results and aspiration findings. Scenario B: ACR/EULAR criteria, followed by aspiration and DECT results. RESULTS: 15/43 patients (34.9%) were positive for MSU crystals, and 16/43 patients (37.2%) for gouty tophi (DECT). 26/43 patients (60.5%) were diagnosed with gout and fulfilled the ACR/EULAR criteria. The diagnostic performance of either synovial fluid aspiration or DECT was similar with sensitivity of 58% and specificity of 100% and 94%, respectively. Combination of both modalities (at least one of them positive), resulted in increased sensitivity of 85% and unchanged specificity (94%). Based only on clinical and laboratory findings, 13/43 patients (30.2%) were classified as gout according to ACR/EULAR criteria. In scenario A, additional 8 out of 30 (26.7%) patients were diagnosed as gout by DECT findings, and another 5/22 (22.7%) patients by aspiration findings. In scenario B, initial consideration of aspiration findings resulted in 10 out of 30 (33.3%) additionally identified patients, and another 3 (15%) patients by DECT findings. There was no relevant difference between scenarios A and B (p=0.508). CONCLUSIONS: Combination of joint aspiration and DECT improves the diagnostic algorithm for gout. In our attempt to establish an optimal sequence of diagnostic tests, we did not identify an advantage for either synovial fluid analysis or DECT as the initially better modality after clinical examination and analysis of blood tests.


Assuntos
Artrite Gotosa/diagnóstico por imagem , Artrite Gotosa/metabolismo , Articulações/química , Articulações/diagnóstico por imagem , Tomografia Computadorizada Multidetectores , Líquido Sinovial/química , Ácido Úrico/análise , Adulto , Idoso , Cristalização , Feminino , Humanos , Masculino , Microscopia de Polarização , Pessoa de Meia-Idade , Valor Preditivo dos Testes , Estudos Prospectivos , Reprodutibilidade dos Testes , Sucção
5.
Skeletal Radiol ; 47(12): 1719, 2018 12.
Artigo em Inglês | MEDLINE | ID: mdl-30187109

RESUMO

The name of Kay Geert A. Hermann is incorrectly captured in the original article and is now corrected in this paper.

6.
Skeletal Radiol ; 46(2): 185-190, 2017 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-27872954

RESUMO

OBJECTIVE: Dual-energy computed tomography detects tophi in patients with chronic gout. However, other information that can be obtained from the same scan is not the focus of the current research, e.g., the detection of bone marrow edema (BME) using virtual bone marrow imaging (VBMI). The aim of this study was to evaluate if BME in patients with acute arthritis can be detected with VBMI using magnetic resonance imaging (MRI) as the standard of reference. MATERIALS AND METHODS: This retrospective study included 11 patients who underwent both MRI and dual-energy computed tomography (mean interval of 40 days). BME in MRI (standard of reference) and VBMI was judged independently by two different blinded readers. φ-correlation coefficient and Cohen's κ were performed for statistical analysis. Approval was waived by the IRB. RESULTS: Two patients with a final diagnosis of RA and one with septic arthritis showed osteitis on MRI and VBMI. However, in each case, there were individual bones identified with osteitis on MRI but not VBMI. Three additional patients with the final diagnosis of RA were identified correctly as negative for BME. There was a good correlation between both modalities (φ = 0.8; κ = 0.8). Inter-rater reliability was excellent for both modalities (κ = 0.9). CONCLUSIONS: We have shown that detecting osteitis using VBMI is feasible in patients with inflammatory arthritis. Further studies are needed on larger, more-targeted populations to better define the indications, accuracy, and added value of this technique.


Assuntos
Artrite Reumatoide/diagnóstico por imagem , Medula Óssea/diagnóstico por imagem , Edema/diagnóstico por imagem , Gota/diagnóstico por imagem , Imageamento por Ressonância Magnética/métodos , Osteíte/diagnóstico por imagem , Tomografia Computadorizada por Raios X/métodos , Doença Aguda , Idoso , Idoso de 80 Anos ou mais , Diagnóstico Diferencial , Estudos de Viabilidade , Feminino , Humanos , Interpretação de Imagem Assistida por Computador , Masculino , Pessoa de Meia-Idade , Reprodutibilidade dos Testes , Estudos Retrospectivos
7.
COPD ; 14(6): 597-602, 2017 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-29023143

RESUMO

The purpose of this research was to evaluate respiratory gated CT of the lung in patients with COPD for analysis of parenchymal characteristics who were potential candidates for volume reduction surgery. Eleven patients with clinically known emphysematous disease underwent a respiratory gated, free-breathing 64-multislice-CT (Aquilion 64, Toshiba). Retrospective image reconstruction was performed similar to cardiac CT at every 10% of the respiratory loop, resulting in 10 complete volumetric datasets at 10 equidistant time points. All images were transferred onto a PC for calculation of the total lung volume, emphysema volume, emphysema index, and mean lung density. Complete datasets could be successfully reconstructed in all patients. The mean lung volume increased from 6.9 L to 7.5 L over the respiratory cycle. Emphysema volume increased from 1.6 L to 2.0 L and emphysema index from 22.6% to 26.5% from expiration to inspiration. In conclusion, respiratory gated chest 4D-CT allows for combined morphologic and functional image analysis, which can provide new insight into functional impairment and individual treatment planning.


Assuntos
Tomografia Computadorizada Quadridimensional/métodos , Pulmão/diagnóstico por imagem , Enfisema Pulmonar/diagnóstico por imagem , Técnicas de Imagem de Sincronização Respiratória/métodos , Idoso , Feminino , Humanos , Processamento de Imagem Assistida por Computador , Pulmão/patologia , Medidas de Volume Pulmonar , Masculino , Pessoa de Meia-Idade , Tamanho do Órgão , Respiração
8.
Skeletal Radiol ; 44(11): 1573-7, 2015 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-26142537

RESUMO

OBJECTIVES: Dual-energy computed tomography (DECT) is an emerging imaging technique for examining patients with suspected gout. Single-source dual-energy CT (S-DECT) is a new way of obtaining DECT information on conventional CT scanners rather than using special dual-source CT systems. METHODS: We tested the feasibility of S-DECT (320-row CT; Aquilion ONE, Toshiba Medical Systems, Otawara, Japan) in 6 patients (5 men, 1 woman; mean age 61.3, range 48 to 69 years) with acute arthralgia and suspected gout, and compared the S-DECT findings with the results of joint aspiration. RESULTS: Three patients had a diagnosis of gouty arthritis with negatively birefringent crystals in synovial fluid, in addition to gouty tophi in S-DECT. Three patients had no detectable crystals by polarization microscopy and no tophi on DECT. Their final diagnoses were rheumatoid arthritis, activated osteoarthritis, and septic arthritis in one case each. CONCLUSION: This initial experience suggests that S-DECT might be a valuable alternative to dual-source CT. Hence, more patients may benefit from its additional diagnostic abilities in the future.


Assuntos
Artralgia/diagnóstico por imagem , Tomografia Computadorizada por Raios X/métodos , Doença Aguda , Idoso , Artralgia/complicações , Artralgia/patologia , Biópsia por Agulha , Estudos de Viabilidade , Feminino , Gota/complicações , Gota/diagnóstico por imagem , Gota/patologia , Humanos , Imageamento Tridimensional , Masculino , Pessoa de Meia-Idade , Imagem Radiográfica a Partir de Emissão de Duplo Fóton , Valores de Referência
9.
Eur Radiol Exp ; 8(1): 69, 2024 Jun 12.
Artigo em Inglês | MEDLINE | ID: mdl-38862843

RESUMO

BACKGROUND: Dual-energy computed tomography (DECT) is useful for detecting gouty tophi. While iodinated contrast media (ICM) might enhance the detection of monosodium urate crystals (MSU), higher iodine concentrations hamper their detection. Calculating virtual noncontrast (VNC) images might improve the detection of enhancing tophi. The aim of this study was to evaluate MSU detection with VNC images from DECT acquisitions in phantoms, compared against the results with standard DECT reconstructions. METHODS: A grid-like and a biophantom with 25 suspensions containing different concentrations of ICM (0 to 2%) and MSU (0 to 50%) were scanned with sequential single-source DECT using an ascending order of tube current time product at 80 kVp (16.5-220 mAs) and 135 kVp (2.75-19.25 mAs). VNC images were equivalently reconstructed at 80 and 135 kVp. Two-material decomposition analysis for MSU detection was applied for the VNC and conventional CT images. MSU detection and attenuation values were compared in both modalities. RESULTS: For 0, 0.25, 0.5, 1, and 2% ICM, the average detection indices (DIs) for all MSU concentrations (35-50%) with VNC postprocessing were respectively 25.2, 36.6, 30.9, 38.9, and 45.8% for the grid phantom scans and 11.7, 9.4, 5.5, 24.0, and 25.0% for the porcine phantom scans. In the conventional CT image group, the average DIs were respectively 35.4, 54.3, 45.4, 1.0, and 0.0% for the grid phantom and 19.4, 17.9, 3.0, 0.0, and 0.0% for the porcine phantom scans. CONCLUSIONS: VNC effectively reduces the suppression of information caused by high concentrations of ICM, thereby improving the detection of MSU. RELEVANCE STATEMENT: Contrast-enhanced DECT alone may suffice for diagnosing gout without a native acquisition. KEY POINTS: • Highly concentrated contrast media hinders monosodium urate crystal detection in CT imaging • Virtual noncontrast imaging redetects monosodium urate crystals in high-iodinated contrast media concentrations. • Contrast-enhanced DECT alone may suffice for diagnosing gout without a native acquisition.


Assuntos
Meios de Contraste , Gota , Imagens de Fantasmas , Tomografia Computadorizada por Raios X , Ácido Úrico , Tomografia Computadorizada por Raios X/métodos , Ácido Úrico/análise , Gota/diagnóstico por imagem , Imagem Radiográfica a Partir de Emissão de Duplo Fóton/métodos , Animais , Suínos
10.
Eur Radiol Exp ; 7(1): 43, 2023 07 24.
Artigo em Inglês | MEDLINE | ID: mdl-37486463

RESUMO

BACKGROUND: To investigate the influence of iodinated contrast medium (ICM) on detection of monosodium urate (MSU) with dual-energy computed tomography (DECT) in two types of phantoms and demonstrate an example patient for clinical illustration. METHODS: Approval is by the institutional review board, and written informed consent was obtained. A grid-like and a biophantom with 25 suspensions containing different concentrations of ICM (0 to 2%) and MSU (0 to 50%) were prepared and scanned with sequential single-source DECT using established methodology. Ascending orders of tube currents were applied at 80 kVp (16.5 to 220.0 mAs) and 135 kVp (2.75 to 19.25 mAs). Volume and mass measurements were performed using clinical gout software (dual-energy decomposition analysis). Numbers of true-positive and false-positive MSU detections were recorded and compared for different ICM concentrations. We demonstrate a patient with gouty arthritis for clinical illustration. RESULTS: Effects of ICM on MSU detection varied with the amount of iodine. Lower ICM concentrations (0.25 and 0.50%) improved detection of small uric acid concentrations of 35 to 45% in comparison to scans without ICM. However, high ICM concentrations (1 and 2%) almost completely precluded MSU detection for all MSU concentrations investigated. In a patient with gouty arthritis, tophi in the wrist were only detected after intravenous ICM administration. CONCLUSIONS: Exploring multimodal DECT for arthritis imaging, enhancement of ICM influences tophus detection. It can help in visualizing previously undetected MSU depositions but, with too strong enhancement, also obscure tophi. RELEVANCE STATEMENT: Use of iodinated contrast media in dual-energy CT might help in visualizing previously undetected uric acid depositions but, with too strong enhancement, obscure gouty tophi. KEY POINTS: • Iodine significantly influences the uric acid crystal detection in systematic phantom studies. • Lower iodine concentrations improved detection of low and medium uric acid concentrations. • High concentrations of iodine hampered detection of all uric acid concentrations.


Assuntos
Artrite Gotosa , Iodo , Humanos , Ácido Úrico/análise , Meios de Contraste , Tomografia Computadorizada por Raios X/métodos
11.
Diagnostics (Basel) ; 13(12)2023 Jun 15.
Artigo em Inglês | MEDLINE | ID: mdl-37370971

RESUMO

Computed tomography (CT)-based Thermography (CTT) is currently being investigated as a non-invasive temperature monitoring method during ablation procedures. Since multiple CT scans with defined time intervals were acquired during this procedure, interscan motion artifacts can occur between the images, so registration is required. The aim of this study was to investigate different registration algorithms and their combinations for minimizing inter-scan motion artifacts during thermal ablation. Four CTT datasets were acquired using microwave ablation (MWA) of normal liver tissue performed in an in vivo porcine model. During each ablation, spectral CT volume scans were sequentially acquired. Based on initial reconstructions, rigid or elastic registration, or a combination of these, were carried out and rated by 15 radiologists. Friedman's test was used to compare rating results in reader assessments and revealed significant differences for the ablation probe movement rating only (p = 0.006; range, 5.3-6.6 points). Regarding this parameter, readers assessed rigid registration as inferior to other registrations. Quantitative analysis of ablation probe movement yielded a significantly decreased distance for combined registration as compared with unregistered data. In this study, registration was found to have the greatest influence on ablation probe movement, with connected registration being superior to only one registration process.

12.
Insights Imaging ; 14(1): 189, 2023 Nov 14.
Artigo em Inglês | MEDLINE | ID: mdl-37962712

RESUMO

OBJECTIVES: The aim of the study was to investigate computed tomography-based thermography (CTT) for ablation zone prediction in microwave ablation (MWA). METHODS: CTT was investigated during MWA in an in vivo porcine liver. For CTT, serial volume scans were acquired every 30 s during ablations and every 60 s immediately after MWA. After the procedure, contrast-enhanced computed tomography (CECT) was performed. After euthanasia, the liver was removed for sampling and further examination. Color-coded CTT maps were created for visualization of ablation zones, which were compared with both CECT and macroscopy. Average CT attenuation values in Hounsfield units (HU) were statistically correlated with temperatures using Spearman's correlation coefficient. CTT was retrospectively evaluated in one patient who underwent radiofrequency ablation (RFA) treatment of renal cell carcinoma. RESULTS: A significant correlation between HU and temperature was found with r = - 0.77 (95% confidence interval (CI), - 0.89 to - 0.57) and p < 0.001. Linear regression yielded a slope of - 1.96 HU/°C (95% CI, - 2.66 to - 1.26). Color-coded CTT maps provided superior visualization of ablation zones. CONCLUSION: Our results show that CTT allows visualization of the ablation area and measurement of its size and is feasible in patients, encouraging further exploration in a clinical setting. CRITICAL RELEVANCE STATEMENT: CT-based thermography research software allows visualization of the ablation zone and is feasible in patients, encouraging further exploration in a clinical setting to assess risk reduction of local recurrence.

13.
Sci Rep ; 12(1): 16407, 2022 09 30.
Artigo em Inglês | MEDLINE | ID: mdl-36180510

RESUMO

Dual-energy computed tomography (DECT) is an imaging technique that combines nondestructive morphological cross-sectional imaging of objects and the quantification of their chemical composition. However, its potential to assist investigations in paleontology has not yet been explored. This study investigates quantitative DECT for the nondestructive density- and element-based material decomposition of fossilized bones. Specifically, DECT was developed and validated for imaging-based calcium and fluorine quantification in bones of five fossil vertebrates from different geological time periods and of one extant vertebrate. The analysis shows that DECT material maps can differentiate bone from surrounding sediment and reveals fluorine as an imaging marker for fossilized bone and a reliable indicator of the age of terrestrial fossils. Moreover, the jaw bone mass of Tyrannosaurus rex showed areas of particularly high fluorine concentrations on DECT, while conventional CT imaging features supported the diagnosis of chronic osteomyelitis. These findings highlight the relevance of radiological imaging techniques in the natural sciences by introducing quantitative DECT imaging as a nondestructive approach for material decomposition in fossilized objects, thereby potentially adding to the toolbox of paleontological studies.


Assuntos
Paleontologia , Tomografia Computadorizada por Raios X , Animais , Cálcio , Flúor , Tomografia Computadorizada por Raios X/métodos , Vertebrados
14.
Eur J Radiol ; 139: 109692, 2021 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-33839428

RESUMO

PURPOSE: To derive optimal scanning parameters for single-source dual-energy computed tomography (DECT) in the detection of urate by analyzing influence of tube current ratio (TCR) and total radiation exposure in a phantom. METHOD: Specimens with different urate concentrations in a realistic porcine bio-phantom were repeatedly imaged with sequential single-source DECT scans at 80 kVp (16.5-220 mA s) and 135 kVp (2.75-19.25 mA s). Detection index (DI - true positive minus false positive urate volume) was calculated for every possible tube current combination. Optimal tube current combinations reaching at least 85 % of the highest measured DI of all combinations without exceeding 150 % of equivalent single-energy radiation dose were identified. TCR, DLP and DI were plotted and compared. RESULTS: Cubic regression analysis showed a flattening increase in the DI with increasing tube currents. Five out of the 100 tube current combinations analyzed achieved the detection target: the lowest DLP of 53.9 mGy*cm at 19.25/16.5 mAs (135/80 kVp) achieved a DI of 2.07 mL and the highest DI of 2.11 mL at a dose of 65.3 mGy*cm and 8.25/79.75 mAs. The optimal TCR is between two and four, while both, higher and lower ratios decreased DI. CONCLUSIONS: A minimum tube current of the high-energy scans is needed before an acceptable overall sensitivity is achieved and before increases in low-energy exposure result in more urate detection. High TCRs above 10 are not beneficial while the optimal TCR ranges between two and four, indicating that special care has to be taken in designing a suitable DECT protocol.


Assuntos
Tomografia Computadorizada por Raios X , Ácido Úrico , Animais , Imagens de Fantasmas , Doses de Radiação , Suínos
15.
Eur J Radiol ; 65(2): 228-34, 2008 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-17499951

RESUMO

PURPOSE: The aim of the study was to compare the influence of different reconstruction algorithms on quantitative emphysema analysis in patients with severe emphysema. MATERIAL AND METHODS: Twenty-five patients suffering from severe emphysema were included in the study. All patients underwent inspiratory MDCT (Aquilion-16, slice thickness 1/0.8mm). The raw data were reconstructed using six different algorithms: bone kernel with beam hardening correction (BHC), soft tissue kernel with BHC; standard soft tissue kernel, smooth soft tissue kernel (internal reference standard), standard lung kernel, and high-convolution kernel. The only difference between image data sets was the algorithm employed to reconstruct the raw data, no additional radiation was required. CT data were analysed using self-written emphysema detection and quantification software providing lung volume, emphysema volume (EV), emphysema index (EI) and mean lung density (MLD). RESULTS: The use of kernels with BHC led to a significant decrease in MLD (5%) and EI (61-79%) in comparison with kernels without BHC. The absolute difference (from smooth soft tissue kernel) in MLD ranged from -0.6 to -6.1 HU and were significant different for all kernels. The EV showed absolute differences between -0.05 and -0.4 L and was significantly different for all kernels. The EI showed absolute differences between -0.8 and -5.1 and was significantly different for all kernels. CONCLUSION: The use of kernels with BHC led to a significant decrease in MLD and EI. The absolute differences between different kernels without BHC were small but they were larger than the known interscan variation in patients. Thus, for follow-up examinations the same reconstruction algorithm has to be used and use of BHC has to be avoided.


Assuntos
Algoritmos , Imageamento Tridimensional , Enfisema Pulmonar/diagnóstico por imagem , Tomografia Computadorizada por Raios X/métodos , Adulto , Idoso , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Imagens de Fantasmas , Interpretação de Imagem Radiográfica Assistida por Computador , Testes de Função Respiratória , Software , Estatísticas não Paramétricas
16.
Sci Rep ; 8(1): 15095, 2018 10 10.
Artigo em Inglês | MEDLINE | ID: mdl-30305658

RESUMO

This study examines the influence of iterative reconstruction on bone mineral density (BMD) measurement by comparison with standard quantitative computed tomography (QCT; reference) and two other protocols based on filtered back projection. Ten human cadaver specimens of the lumbar spine with a hydroxyapatite calibration phantom underneath, were scanned with 4 protocols: 1. standard QCT, 2. volume scan with FBP, 3. helical scan with FBP, and 4. helical scan with IR (Adaptive Iterative Dose Reduction 3D (AIDR3D)). Radiation doses were recorded as CT dose index (CTDIvol) and BMD, signal-to-noise and contrast-to-noise ratio were calculated. Mean hydroxyapatite concentration (HOA) did not differ significantly between protocols, ranging from 98.58 ± 31.09 mg cm3 (protocol 4) to 100.47 ± 30.82 mg cm3 (protocol 2). Paired sample correlations of HOA values for protocol 4 and protocols 1, 2 and 3 were nearly perfect with coefficients of 0.980, 0.979 and 0.982, respectively (p < 0.004). CTDIvol were 7.50, 5.00, 6.82 (±2.03) and 1.72 (±0.50) mGy for protocols 1, 2, 3 and 4 respectively. Objective image quality was highest for protocol 4. The use of IR for BMD assessment significantly lowers radiation exposure compared to standard QCT and protocols with FBP while not degrading BMD measurement.


Assuntos
Densidade Óssea , Vértebras Lombares/diagnóstico por imagem , Doses de Radiação , Tomografia Computadorizada por Raios X/métodos , Tomografia Computadorizada por Raios X/normas , Idoso , Idoso de 80 Anos ou mais , Feminino , Humanos , Masculino , Pessoa de Meia-Idade
17.
Br J Radiol ; 91(1084): 20170678, 2018 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-29260893

RESUMO

OBJECTIVE: To assess the accuracy of an iterative reconstruction (IR) technique for coronary artery calcium scoring with reduced radiation dose. METHODS: 163 consecutive patients underwent twofold scanning by 320-row detector CT at 120 kVp. A low-dose scan at 25% tube current but with standard scan length (14 cm) was followed by a standard dose scan with routine tube current but reduced scan length (10 cm). Reduced dose images were constructed using filtered back-projection (FBP) and IR (adaptive iterative dose reduction in three dimensions). The standard dose scan reconstructed with FBP served as the gold standard for comparisons. Image noise and Agatston coronary calcium scores were determined and compared between the groups. RESULTS: Compared with FBP at standard dose, noise at reduced dose increased markedly with FBP but remained low with IR. Mean Agatston score with FBP at reduced dose showed a significant increase as compared with FBP at standard dose. No significant difference was observed when applying IR at reduced dose. At reduced dose, 38 (23.3%) patients were reassigned to a different cardiovascular risk category with FBP but only 8 (4.9%) with IR. Out of 47 patients with a zero Agatston score, 15 patients (31.9%) were false-positive with FBP at reduced dose, but no false positives were found with IR. CONCLUSION: IR allows accurate coronary artery calcium scoring with a radiation dose reduced by 75%. Advances in knowledge: The application of adaptive iterative dose reduction in three dimensions allows the maintenance of accurate Agatston scores and risk stratification at significantly reduced tube current, thus reducing the patient's exposure to ionizing radiation.


Assuntos
Doença das Coronárias/diagnóstico por imagem , Interpretação de Imagem Radiográfica Assistida por Computador/métodos , Tomografia Computadorizada por Raios X/métodos , Calcificação Vascular/diagnóstico por imagem , Idoso , Algoritmos , Feminino , Humanos , Masculino , Doses de Radiação , Medição de Risco
18.
Invest Radiol ; 53(1): 6-12, 2018 01.
Artigo em Inglês | MEDLINE | ID: mdl-28727616

RESUMO

OBJECTIVES: We hypothesize that, compared with filtered back projection (FBP), iterative reconstruction (IR) increases the detected volume of uric acid, which serves as a measure of the sensitivity of the method, and therefore allows examinations with lower radiation exposure. Thus, the aim of our study was to evaluate the role of IR in dual-energy computed tomography (DECT) for gout assessment and volumetry in an ex vivo gout model using an epoxy phantom and a biophantom. MATERIALS AND METHODS: We prepared specimens with different concentrations of monosodium uric acid in ultrasound gel (30%-50%) and inserted them into an epoxy-based phantom and a porcine foreleg. Computed tomography scanning was performed on a 320-row single-source DECT scanner in volume mode with an ascending order of tube currents. Image data sets were reconstructed using FBP and IR with 2 iteration levels (IR1 and IR2). Measurements in regions of interest (ROIs) and volumetric measurements were performed using either fixed parameters for the analysis software (epoxy phantom) or parameters specifically adapted for each data set (porcine phantom). Seven retrospectively identified clinical data sets were used for validation in patients. Rm-ANOVA was used for statistical analysis. No institutional review board approval was required. RESULTS: We found no differences in Hounsfield units between the different reconstruction algorithms (P = 0.09 and 0.05 for 80 and 135 kVp, respectively) and the calculated dual-energy gradient (P = 0.27). Filtered back projection detected less uric acid compared with IR (with fixed parameters: 6.0 ± 0.3 cm for FBP and 6.1 ± 0.2 for IR1 and IR2; with adapted thresholds: 1.2 ± 0.3 cm for FBP and 1.8 ± 0.1 and 2.0 ± 0.1 for IR1 and IR2, respectively). The differences were significant for all measurements (P = 0.0003). Also in the test cases, FBP detected significantly fewer tophi (mean volume, 1.38 ± 2.1 cm) compared with IR1 (1.86 ± 2.9) and IR2 (2.07 ± 3.1) (P = 0.04). CONCLUSIONS: Iterative reconstruction has the potential to improve the sensitivity of a DECT scan for gouty tophi, to decrease radiation exposure, or to combine both options.


Assuntos
Gota/diagnóstico por imagem , Processamento de Imagem Assistida por Computador/métodos , Imagens de Fantasmas , Tomografia Computadorizada por Raios X/métodos , Algoritmos , Animais , Feminino , Humanos , Masculino , Doses de Radiação , Interpretação de Imagem Radiográfica Assistida por Computador/métodos , Imagem Radiográfica a Partir de Emissão de Duplo Fóton/métodos , Estudos Retrospectivos , Suínos
19.
Invest Radiol ; 42(4): 230-4, 2007 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-17351429

RESUMO

OBJECTIVE: We sought to evaluate and validate a low-dose protocol for respiratory-gated multislice computed tomography (CT) for volume calculations in small ventilated neonatal animals as a model for the ventilated human neonatal lung. MATERIALS AND METHODS: Five mechanically ventilated newborn piglets were imaged in a multislice CT scanner (0.5-mm slice thickness, 4:16 pitch, 0.5 seconds rotation time, 120 kV) using a normal (100 mAs) and a reduced (10 mAs) dose protocol. All animals were scanned twice (at 100 and 10 mAs) at each of 3 different ventilator settings. Complete volume datasets were reconstructed throughout the respiratory cycle in increments of 10% using retrospective half-scan reconstruction. End-inspiratory volumes and volumes during maximal expiration (functional residual capacity) were calculated by a customized software and values for normal and reduced dose protocols were compared using Kolmogorov-Smirnov test and Bland-Altman plots. RESULTS: Two volume datasets (one normal and one reduced dose protocol) showed artifacts on the axial images, which could not be analyzed by the software. Those values were determined after manual segmentation and excluded from final analysis. The mean (+/-SD) end-inspiratory volumes and functional residual capacity were 34.3 +/- 10.1 mL and 25.3 +/- 8.0 mL for the normal-dose protocol versus 33.1 +/- 10.0 mL and 24.7 +/- 8.1 mL for the reduced-dose protocol, respectively. There was no statistically significant difference between normal and reduced dose protocol (KS-Test: D = 0.14 < Dmax). CONCLUSION: Lung volume calculation in ventilated newborn piglets (end-inspiratory volumes and functional residual capacity) can be performed using respiratory-gated multislice CT even at a substantially reduced dose (eg, to 10 mAs). This makes the technique a candidate for future pediatric use.


Assuntos
Pneumopatias/diagnóstico , Pulmão/fisiologia , Tomografia Computadorizada por Raios X , Animais , Relação Dose-Resposta à Radiação , Capacidade Residual Funcional , Pulmão/efeitos da radiação , Pneumopatias/patologia , Modelos Animais , Mecânica Respiratória , Suínos
20.
Eur J Radiol ; 85(10): 1829-1834, 2016 10.
Artigo em Inglês | MEDLINE | ID: mdl-27666624

RESUMO

OBJECTIVES: To investigate the diagnostic value of single-source dual-energy computed tomography (SDECT) in gouty arthritis and to compare its capability to detect urate depositions with digital radiography (DR) and conventional computed tomography (CT). METHODS: Forty-four patients who underwent SDECT volume scans of the feet for suspected gouty arthritis were retrospectively analyzed. SDECT, CT (both n=44) and DR (n=36) were scored by three blinded readers for presence of osteoarthritis, erosions, and tophi. A diagnosis was made for each imaging modality. Results were compared to the clinical diagnosis using the American College of Rheumatology (ACR) classification criteria. RESULTS: The patient population was divided into a gout (n=21) and control (n=23) group based on final clinical diagnosis. Osteoarthritis was evident in 15 joints using CT and 30 joints using DR (p=0.165). There were 134 erosions detected by CT compared to 38 erosions detected by DR (p<0.001). In total 119 tophi were detected by SDECT, compared to 85 tophi by CT (p=0.182) and 25 tophi by DR (p<0.001). SDECT had best diagnostic value for diagnosis of gout compared to DR and conventional CT (sensitivity and specificity for SDECT: 71.4% and 95.7%, CT: 71.4% and 91.3% and DR: 44.4% and 83.3%, respectively). For all three readers, Cohen's kappa for DR and conventional CT were substantial for all scoring items and ranged from 0.75 to 0.77 and 0.72-0.76, respectively. For SDECT Cohen's kappa was good to almost perfect with 0.77-0.84. CONCLUSIONS: SDECT is capable to detect uric acid depositions with good sensitivity and high specificity in feet, therefore diagnostic confidence is improved. Using SDECT, inter-reader variance can be markedly reduced for the detection of gouty tophi.


Assuntos
Pé/diagnóstico por imagem , Gota/diagnóstico por imagem , Intensificação de Imagem Radiográfica/métodos , Imagem Radiográfica a Partir de Emissão de Duplo Fóton/métodos , Radiografia , Tomografia Computadorizada por Raios X/métodos , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Reprodutibilidade dos Testes , Estudos Retrospectivos , Sensibilidade e Especificidade