Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 95
Filtrar
1.
Europace ; 25(9)2023 08 02.
Artigo em Inglês | MEDLINE | ID: mdl-37622591

RESUMO

This reviews the transition of remote monitoring of patients with cardiac electronic implantable devices from curiosity to standard of care. This has been delivered by technology evolution from patient-activated remote interrogations at appointed intervals to continuous monitoring that automatically flags clinically actionable information to the clinic for review. This model has facilitated follow-up and received professional society recommendations. Additionally, continuous monitoring has provided a new level of granularity of diagnostic data enabling extension of patient management from device to disease management. This ushers in an era of digital medicine with wider applications in cardiovascular medicine.


Assuntos
Fármacos Cardiovasculares , Humanos , Eletrônica , Coração , Tecnologia , Gerenciamento Clínico
2.
Europace ; 26(1)2023 Dec 28.
Artigo em Inglês | MEDLINE | ID: mdl-38225168

RESUMO

AIMS: Conduction abnormalities post-transcatheter aortic valve implantation (TAVI) are common. Post-TAVI PR prolongation was mainly studied as an adjunct to new-onset bundle branch block. The net effect of isolated PR prolongation (IPRP) without post-TAVI QRS changes is not well known. The aim of this study was to define the incidence and clinical significance of post-TAVI IPRP. METHODS AND RESULTS: A total of 1108 consecutive TAVI patients were reviewed. Patients with IPRP were compared with patients without post-TAVI electrocardiogram (ECG) changes. Clinical outcomes included permanent pacemaker implantation (PPI) and overall mortality. A total of 146 patients with IPRP were compared with 290 patients without post-TAVI ECG changes. At 1 year follow-up, 4 (2.7%) and 7 (2.4%) patients underwent PPI (P = 0.838) and 10 (6.8%) and 25 (8.6%) died (P = 0.521), from the study and control groups, respectively. No patient with IPRP and narrow QRS underwent PPI during 1 year post-TAVI, and all death events were non-cardiac except one unknown cause. Permanent pacemaker implantation rates among patients with IPRP and wide QRS were higher (n = 4, 12.1%), compared with patients with wide QRS without post-TAVI ECG change (n = 3, 4%) however not reaching statistical significance (P = 0.126). Multivariate Cox proportional hazards model demonstrated that in patients with narrow QRS, neither PR prolongation nor baseline or maximal PR intervals was associated with the combined endpoint of PPI and mortality. However, in patients with wide QRS, baseline PR intervals and QRS width, but not PR prolongation were associated with the combined outcome. CONCLUSION: Post-TAVI IPRP in patients with narrow QRS is not associated with adverse outcome. This finding may translate clinically into a more permissive approach to these patients.


Assuntos
Estenose da Valva Aórtica , Próteses Valvulares Cardíacas , Marca-Passo Artificial , Substituição da Valva Aórtica Transcateter , Humanos , Substituição da Valva Aórtica Transcateter/efeitos adversos , Marca-Passo Artificial/efeitos adversos , Incidência , Relevância Clínica , Estimulação Cardíaca Artificial/efeitos adversos , Estimulação Cardíaca Artificial/métodos , Estenose da Valva Aórtica/cirurgia , Estenose da Valva Aórtica/complicações , Resultado do Tratamento , Bloqueio de Ramo/diagnóstico , Bloqueio de Ramo/epidemiologia , Bloqueio de Ramo/terapia , Eletrocardiografia , Valva Aórtica/cirurgia , Próteses Valvulares Cardíacas/efeitos adversos
3.
Europace ; 25(3): 1025-1034, 2023 03 30.
Artigo em Inglês | MEDLINE | ID: mdl-36635857

RESUMO

AIMS: Little is known about patients with right bundle branch block (RBBB)-ventricular tachycardia (VT) and arrhythmogenic cardiomyopathy (ACM). Our aims were: (i) to describe electrocardiogram (ECG) characteristics of sinus rhythm (SR) and VT; (ii) to correlate SR with RBBB-VT ECGs; and (iii) to compare VT ECGs with electro-anatomic mapping (EAM) data. METHODS AND RESULTS: From the European Survey on ACM, 70 patients with spontaneous RBBB-VT were included. Putative left ventricular (LV) sites of origin (SOOs) were estimated with a VT-axis-derived methodology and confirmed by EAM data when available. Overall, 49 (70%) patients met definite Task Force Criteria. Low QRS voltage predominated in lateral leads (n = 37, 55%), but QRS fragmentation was more frequent in inferior leads (n = 15, 23%). T-wave inversion (TWI) was equally frequent in inferior (n = 28, 42%) and lateral (n = 27, 40%) leads. TWI in inferior leads was associated with reduced LV ejection fraction (LVEF; 46 ± 10 vs. 53 ± 8, P = 0.02). Regarding SOOs, the inferior wall harboured 31 (46%) SOOs, followed by the lateral wall (n = 17, 25%), the anterior wall (n = 15, 22%), and the septum (n = 4, 6%). EAM data were available for 16 patients and showed good concordance with the putative SOOs. In all patients with superior-axis RBBB-VT who underwent endo-epicardial VT activation mapping, VT originated from the LV. CONCLUSIONS: In patients with ACM and RBBB-VT, RBBB-VTs originated mainly from the inferior and lateral LV walls. SR depolarization and repolarization abnormalities were frequent and associated with underlying variants.


Assuntos
Cardiomiopatias , Taquicardia Ventricular , Humanos , Bloqueio de Ramo , Taquicardia Ventricular/etiologia , Taquicardia Ventricular/complicações , Ventrículos do Coração , Eletrocardiografia , Cardiomiopatias/complicações , Cardiomiopatias/diagnóstico
4.
J Cardiovasc Electrophysiol ; 33(4): 618-625, 2022 04.
Artigo em Inglês | MEDLINE | ID: mdl-35118762

RESUMO

BACKGROUND: A novel 3D mapping system (KODEX-EPD, EPD Solutions) enables catheter localization and real-time 3D cardiac mapping. OBJECTIVE: To evaluate left atrium (LA) anatomical mapping accuracy created by the KODEX-EPD system during pulmonary vein isolation (PVI) compared with gold standard computed tomography (CT) images acquired from the same patients before the procedure. METHODS: In 15 consecutive patients who underwent PVI, 3D mapping of the LA was created on the KODEX-EPD system using the Achieve catheter. Pulmonary vein (PV), posterior wall, and appendage anatomy and diameters, were compared to the CT 3D reconstruction measured on the CARTO 3 system. Measurements were done independently by two physicians in each method. Linear correlation and agreement between CT and EPD measurements were assessed by Spearman correlation and Bland-Altman plot. RESULTS: Mean LA mapping time was 7.7 ± 3.6 min. Very high interobserver correlation was found for both EPD and CT measurements (Spearman r = .9). High correlation (r = .75) was found between CT and EPD measurements. Bland-Altman plot method revealed that measurements assessed by EPD were slightly higher than those assessed by CT. Mean difference was 3.5 mm, p < .01. In 2 (13.5%) patients each, disagreement regarding the presence of a left common PV and a right middle accessory vein anatomy was seen. CONCLUSION: The new KODEX-EPD mapping system allows quick and accurate mapping of the LA with high correlation to CT imaging. Some differences in left common and accessory right middle vein anatomy were seen.


Assuntos
Fibrilação Atrial , Ablação por Cateter , Veias Pulmonares , Fibrilação Atrial/diagnóstico por imagem , Fibrilação Atrial/cirurgia , Ablação por Cateter/métodos , Computadores , Átrios do Coração/diagnóstico por imagem , Átrios do Coração/cirurgia , Humanos , Imageamento Tridimensional/métodos , Veias Pulmonares/diagnóstico por imagem , Veias Pulmonares/cirurgia , Tomografia Computadorizada por Raios X
5.
Europace ; 24(5): 817-827, 2022 05 03.
Artigo em Inglês | MEDLINE | ID: mdl-34652415

RESUMO

AIMS: The aims of this study is to characterize the transvenous lead extraction (TLE) population with active (A) compared with passive fixation (PFix) leads and to compare the safety, efficacy, and ease of extracting active fixation (AFix) compared with PFix right atrial (RA) and right ventricular (RV) leads. METHODS AND RESULTS: The European Lead Extraction ConTRolled Registry (ELECTRa) was analysed. Patients were divided into three groups; those with only AFix, only PFix, and combined Fix leads. Three outcomes were defined. Difficult extraction, complete radiological, and clinical success. Multivariate model was used to analyse the independent effect of Fix mechanism on these outcomes. The study included 2815 patients, 1456 (51.7%) with only AFix leads, 982 (34.9%) with only PFix leads, and 377 (13.4%) with combined Fix leads. Patients with AFix leads were younger with shorter lead dwelling time. Infection was the leading cause for TLE among the combined Fix group with lowest rates among AFix group. No difference in complications rates was noted between patients with only AFix vs. PFix leads. Overall, there were 1689 RA (1046 AFix and 643 PFix) and 2617 RV leads (1441 AFix and 1176 PFix). Multivariate model demonstrated that PFix is independently associated with more difficult extraction for both RA and RV leads, lower radiological success in the RA but has no effect on clinical success. CONCLUSION: Mechanism of Fix impact the ease of TLE of RA and RV leads and rates of complete radiological success in the RA but not clinical success. These findings should be considered during implantation and TLE procedures.


Assuntos
Desfibriladores Implantáveis , Marca-Passo Artificial , Desfibriladores Implantáveis/efeitos adversos , Remoção de Dispositivo/efeitos adversos , Remoção de Dispositivo/métodos , Humanos , Marca-Passo Artificial/efeitos adversos , Sistema de Registros , Estudos Retrospectivos , Resultado do Tratamento
6.
Europace ; 24(1): 165-172, 2022 01 04.
Artigo em Inglês | MEDLINE | ID: mdl-34455442

RESUMO

AIMS: To develop a suite of quality indicators (QIs) for the evaluation of the care and outcomes for adults undergoing cardiac pacing. METHODS AND RESULTS: Under the auspice of the Clinical Practice Guideline Quality Indicator Committee of the European Society of Cardiology (ESC), the Working Group for cardiac pacing QIs was formed. The Group comprised Task Force members of the 2021 ESC Clinical Practice Guidelines on Cardiac Pacing and Cardiac Resynchronization Therapy, members of the European Heart Rhythm Association, international cardiac device experts, and patient representatives. We followed the ESC methodology for QI development, which involved (i) the identification of the key domains of care by constructing a conceptual framework of the management of patients receiving cardiac pacing, (ii) the development of candidate QIs by conducting a systematic review of the literature, (iii) the selection of the final set of QIs using a modified-Delphi method, and (iv) the evaluation of the feasibility of the developed QIs. Four domains of care were identified: (i) structural framework, (ii) patient assessment, (iii) pacing strategy, and (iv) clinical outcomes. In total, seven main and four secondary QIs were selected across these domains and were embedded within the 2021 ESC Guidelines on Cardiac Pacing and Cardiac Resynchronization therapy. CONCLUSION: By way of a standardized process, 11 QIs for cardiac pacing were developed. These indicators may be used to quantify adherence to guideline-recommended clinical practice and have the potential to improve the care and outcomes of patients receiving cardiac pacemakers.


Assuntos
Terapia de Ressincronização Cardíaca , Cardiologia , Marca-Passo Artificial , Adulto , Comitês Consultivos , Terapia de Ressincronização Cardíaca/efeitos adversos , Humanos , Indicadores de Qualidade em Assistência à Saúde
7.
Harefuah ; 161(7): 454-457, 2022 Jul.
Artigo em Hebraico | MEDLINE | ID: mdl-35833433

RESUMO

INTRODUCTION: For many years routine screening of athletes in Israel includes frequently performed ECGs and exercise tests that overload the system with questionable benefits. The purpose of the current document is to reevaluate the need for pre-participation testing and establish new evidence-based guidelines. It should be noted that our proposal for a change of approach relates only to subjects whose health questionnaire is normal, who do not have a family history of sudden and unexpected death at an early age, or a family history of hereditary heart disease and whose physical examination from a cardiovascular point of view is normal.


Assuntos
Doenças Cardiovasculares , Esportes , Atletas , Doenças Cardiovasculares/diagnóstico , Doenças Cardiovasculares/prevenção & controle , Morte Súbita Cardíaca/etiologia , Morte Súbita Cardíaca/prevenção & controle , Eletrocardiografia , Humanos , Israel , Programas de Rastreamento , Exame Físico , Organização Mundial da Saúde
8.
Int J Clin Pract ; 75(4): e13788, 2021 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-33128270

RESUMO

OBJECTIVES: A significant proportion of COVID-19 patients may have cardiac involvement including arrhythmias. Although arrhythmia characterisation and possible predictors were previously reported, there are conflicting data regarding the exact prevalence of arrhythmias. Clinically applicable algorithms to classify COVID patients' arrhythmic risk are still lacking, and are the aim of our study. METHODS: We describe a single-centre cohort of hospitalised patients with a positive nasopharyngeal swab for COVID-19 during the initial Israeli outbreak between 1/2/2020 and 30/5/2020. The study's outcome was any documented arrhythmia during hospitalisation, based on daily physical examination, routine ECG's, periodic 24-hour Holter, and continuous monitoring. Multivariate analysis was used to find predictors for new arrhythmias and create classification trees for discriminating patients with high and low arrhythmic risk. RESULTS: Out of 390 COVID-19 patients included, 28 (7.2%) had documented arrhythmias during hospitalisation, including 23 atrial tachyarrhythmias, combined atrial fibrillation (AF), and ventricular fibrillation, ventricular tachycardia storm, and 3 bradyarrhythmias. Only 7/28 patients had previous arrhythmias. Our study showed a significant correlation between disease severity and arrhythmia prevalence (P < .001) with a low arrhythmic prevalence amongst mild disease patients (2%). Multivariate analysis revealed background heart failure (CHF) and disease severity are independently associated with overall arrhythmia while age, CHF, disease severity, and arrhythmic symptoms are associated with tachyarrhythmias. A novel decision tree using age, disease severity, CHF, and troponin levels was created to stratify patients into high and low risk for developing arrhythmia. CONCLUSIONS: Dominant arrhythmia amongst COVID-19 patients is AF. Arrhythmia prevalence is associated with age, disease severity, CHF, and troponin levels. A novel simple Classification tree, based on these parameters, can discriminate between high and low arrhythmic risk patients.


Assuntos
Arritmias Cardíacas , COVID-19 , Coronavirus , Algoritmos , Arritmias Cardíacas/complicações , Arritmias Cardíacas/diagnóstico , COVID-19/complicações , Humanos , Prevalência , SARS-CoV-2
9.
Int J Clin Pract ; 74(10): e13583, 2020 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-32533880

RESUMO

AIMS: Many tachy-brady syndrome (TBS) patients, are implanted a permanent pacemaker (PPM) to allow continuation of anti-arrhythmic drug (AAD) therapy to maintain sinus rhythm. Many of these PPM's are implanted as a preventive measure, in absence of symptomatic bradycardia. Our primary aim was to evaluate pacing use among these patients and find predictors for PPM use. Our secondary aim was to appreciate the portion of these patients who progress to permanent atrial fibrillation (AF). METHODS: Retrospective study of TBS patients implanted a PPM as preventive measure, dividing cases into defined categories regarding highest percent atrial and ventricular pacing documented in PPM clinic visits during 3 year follow-up (F/U) period. Patients' baseline characteristics and AAD therapy were compared between cases with a major (>90%) pacing use and cases with <90% pacing use to find predictors for pacing use. Multivariable logistic regression was applied to identify independent variables associated with major pacing use. RESULTS: Our study included 119 TBS patients. Most (86.5%) TBS patients had a moderate (>50%) pacing use and 58% had a major pacing use. Significant association was found between pre-implant severe sinus bradycardia (<40 bpm), first degree atrioventricular block and amiodarone treatment to major pacing use on univariate analysis and severe sinus bradycardia was significantly associated with major pacing on multivariate analysis as well. Only minority (16.8%) of TBS patients progressed to permanent AF during the study F/U period. CONCLUSION: Our study reveals most TBS patients succeed to maintain sinus rhythm using an AAD with a significant pacing use, suggesting preventive PPM implantation might be advantageous in these cases. Pre-implant severe sinus bradycardia (<40 bpm) is a possible predictor for major pacing use in this population.


Assuntos
Fibrilação Atrial/terapia , Bradicardia/terapia , Estimulação Cardíaca Artificial/estatística & dados numéricos , Síndrome do Nó Sinusal/terapia , Idoso , Antiarrítmicos/uso terapêutico , Fibrilação Atrial/tratamento farmacológico , Fibrilação Atrial/etiologia , Bradicardia/tratamento farmacológico , Bradicardia/etiologia , Feminino , Átrios do Coração/fisiopatologia , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Retrospectivos , Síndrome do Nó Sinusal/complicações , Síndrome do Nó Sinusal/tratamento farmacológico
10.
Europace ; 21(11): 1670-1677, 2019 Nov 01.
Artigo em Inglês | MEDLINE | ID: mdl-31504477

RESUMO

AIMS: To define the clinical characteristics and long-term clinical outcomes of a large cohort of patients with idiopathic ventricular fibrillation (IVF) and normal 12-lead electrocardiograms (ECGs). METHODS AND RESULTS: Patients with ventricular fibrillation as the presenting rhythm, normal baseline, and follow-up ECGs with no signs of cardiac channelopathy including early repolarization or atrioventricular conduction abnormalities, and without structural heart disease were included in a registry. A total of 245 patients (median age: 38 years; males 59%) were recruited from 25 centres. An implantable cardioverter-defibrillator (ICD) was implanted in 226 patients (92%), while 18 patients (8%) were treated with drug therapy only. Over a median follow-up of 63 months (interquartile range: 25-110 months), 12 patients died (5%); in four of them (1.6%) the lethal event was of cardiac origin. Patients treated with antiarrhythmic drugs only had a higher rate of cardiovascular death compared to patients who received an ICD (16% vs. 0.4%, P = 0.001). Fifty-two patients (21%) experienced an arrhythmic recurrence. Age ≤16 years at the time of the first ventricular arrhythmia was the only predictor of arrhythmic recurrence on multivariable analysis [hazard ratio (HR) 0.41, 95% confidence interval (CI) 0.18-0.92; P = 0.03]. CONCLUSION: Patients with IVF and persistently normal ECGs frequently have arrhythmic recurrences, but a good prognosis when treated with an ICD. Children are a category of IVF patients at higher risk of arrhythmic recurrences.


Assuntos
Desfibriladores Implantáveis , Eletrocardiografia , Parada Cardíaca Extra-Hospitalar/etiologia , Sistema de Registros , Fibrilação Ventricular/complicações , Adolescente , Adulto , Criança , Feminino , Seguimentos , Humanos , Masculino , Pessoa de Meia-Idade , Parada Cardíaca Extra-Hospitalar/diagnóstico , Parada Cardíaca Extra-Hospitalar/terapia , Valores de Referência , Estudos Retrospectivos , Fatores de Tempo , Fibrilação Ventricular/diagnóstico , Fibrilação Ventricular/fisiopatologia , Adulto Jovem
11.
Europace ; 21(5): 796-802, 2019 May 01.
Artigo em Inglês | MEDLINE | ID: mdl-30590530

RESUMO

AIMS: Data on predictors of time-to-first appropriate implantable cardioverter-defibrillator (ICD) therapy in patients with Brugada Syndrome (BrS) and prophylactically implanted ICD's are scarce. METHODS AND RESULTS: SABRUS (Survey on Arrhythmic Events in BRUgada Syndrome) is an international survey on 678 BrS patients who experienced arrhythmic event (AE) including 252 patients in whom AE occurred after prophylactic ICD implantation. Analysis was performed on time-to-first appropriate ICD discharge regarding patients' characteristics. Multivariate logistic regression models were utilized to identify which parameters predicted time to arrhythmia ≤5 years. The median time-to-first appropriate ICD therapy was 24.8 ± 2.8 months. A shorter time was observed in patients from Asian ethnicity (P < 0.05), those with syncope (P = 0.001), and those with Class IIa indication for ICD (P = 0.001). A longer time was associated with a positive family history of sudden cardiac death (P < 0.05). Multivariate Cox regression revealed shorter time-to-ICD therapy in patients with syncope [odds ratio (OR) 1.65, P = 0.001]. In 193 patients (76.6%), therapy was delivered during the first 5 years. Factors associated with this time were syncope (OR 0.36, P = 0.001), spontaneous Type 1 Brugada electrocardiogram (ECG) (OR 0.5, P < 0.05), and Class IIa indication (OR 0.38, P < 0.01) as opposed to Class IIb (OR 2.41, P < 0.01). A near-significant trend for female gender was also noted (OR 0.13, P = 0.052). Two score models for prediction of <5 years to shock were built. CONCLUSION: First appropriate therapy in BrS patients with prophylactic ICD's occurred during the first 5 years in 76.6% of patients. Syncope and spontaneous Type 1 Brugada ECG correlated with a shorter time to ICD therapy.


Assuntos
Síndrome de Brugada , Morte Súbita Cardíaca , Desfibriladores Implantáveis , Implantação de Prótese , Síncope/diagnóstico , Adulto , Síndrome de Brugada/complicações , Síndrome de Brugada/cirurgia , Morte Súbita Cardíaca/etiologia , Morte Súbita Cardíaca/prevenção & controle , Eletrocardiografia/métodos , Feminino , Humanos , Masculino , Prognóstico , Implantação de Prótese/instrumentação , Implantação de Prótese/métodos , Implantação de Prótese/estatística & dados numéricos , Fatores de Risco , Fatores Sexuais , Inquéritos e Questionários , Fatores de Tempo
12.
Isr Med Assoc J ; 21(12): 790-795, 2019 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-31814341

RESUMO

BACKGROUND: Patients with right bundle branch block (RBBB) prior to transcatheter aortic valve implantation (TAVI) are at high risk for immediate post-procedural heart block and long-term mortality when discharged without a pacemaker. OBJECTIVES: To test whether prophylactic permanent pacemaker implantation (PPI) is beneficial. METHODS: Of 795 consecutive patients who underwent TAVI, 90 patients had baseline RBBB. We compared characteristics and outcomes of the prophylactic PPI with post-TAVI PPI. Need for pacing was defined as  greater than 1% ventricular pacing. RESULTS: Forty patients with RBBB received a prophylactic PPI (group 1), and in 50 the decision was based on standard post-procedural indications (group 2). There were no significant differences in clinical baseline characteristics. One patient developed a tamponade after a PPI post-TAVI. A trend toward shorter hospitalization duration in group 1 patients was observed (P = 0.06). On long-term follow-up of 848 ± 56 days, no differences were found in overall survival (P = 0.77), the composite event-free survival of both mortality and hospitalizations (P = 0.66), or mortality and syncope (P = 0.65). On multivariate analysis, independent predictors of the need for pacing included baseline PR interval increase of 10ms (odds ratio [OR] 1.21 per 10 ms increment 95% confidence interval [95%CI] 1.02-1.44, P = 0.028), and the use of new generation valves (OR 3.92, 95%CI 1.23-12.46, P = 0.023). CONCLUSIONS: In patients with baseline pre-TAVI RBBB, no outcome differences were found with prophylactic PPI. On multivariate analysis, predictors of the need for pacing included baseline long PR interval, and the use of newer generation valves.


Assuntos
Bloqueio de Ramo , Estimulação Cardíaca Artificial , Complicações Pós-Operatórias , Cuidados Pré-Operatórios/métodos , Substituição da Valva Aórtica Transcateter , Idoso , Idoso de 80 Anos ou mais , Estenose da Valva Aórtica/epidemiologia , Estenose da Valva Aórtica/cirurgia , Bloqueio de Ramo/diagnóstico , Bloqueio de Ramo/terapia , Estimulação Cardíaca Artificial/métodos , Estimulação Cardíaca Artificial/estatística & dados numéricos , Feminino , Humanos , Israel/epidemiologia , Tempo de Internação/estatística & dados numéricos , Masculino , Mortalidade , Avaliação de Processos e Resultados em Cuidados de Saúde , Marca-Passo Artificial , Complicações Pós-Operatórias/mortalidade , Complicações Pós-Operatórias/prevenção & controle , Utilização de Procedimentos e Técnicas/estatística & dados numéricos , Substituição da Valva Aórtica Transcateter/efeitos adversos , Substituição da Valva Aórtica Transcateter/métodos
13.
J Electrocardiol ; 51(5): 874-878, 2018.
Artigo em Inglês | MEDLINE | ID: mdl-30177332

RESUMO

Verapamil-sensitive left fascicular monomorphic ventricular tachycardia (LF-VT) was first described ~4 decades ago. Our knowledge regarding this arrhythmia is evolving continuously. The current review aims to highlight up to date aspects of this arrhythmia focusing on its ECG recognition, new considerations of the reentrant circuit, ablation targets in inducible and non-inducible patients and the approach to LF-VT with multiform morphology.


Assuntos
Eletrocardiografia , Taquicardia Ventricular , Ablação por Cateter/métodos , Diagnóstico Diferencial , Sistema de Condução Cardíaco/anatomia & histologia , Humanos , Taquicardia Ventricular/diagnóstico , Taquicardia Ventricular/fisiopatologia , Taquicardia Ventricular/terapia , Verapamil/uso terapêutico
14.
Isr Med Assoc J ; 20(8): 467-471, 2018 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-30084569

RESUMO

BACKGROUND: The incidence, characteristics, and clinical significance of catheter-induced mechanical suppression (trauma) of ventricular arrhythmias originating in the outflow tract (OT) area have not been thoroughly evaluated. OBJECTIVES: To determine these variables among our patient cohort. METHODS: All consecutive patients with right ventricular OT (RVOT) and left ventricular OT (LVOT) arrhythmias ablated at two medical centers from 1998 to 2014 were included. Patients were observed for catheter-induced trauma during ablation procedures. Procedural characteristics, as well as response to catheter-induced trauma and long term follow-up, were recorded. RESULTS: During 288 ablations of OT arrhythmias in 273 patients (RVOT n=238, LVOT n=50), we identified 8 RVOT cases (3.3%) and 1 LVOT (2%) case with catheter-induced trauma. Four cases of trauma were managed by immediate radiofrequency ablation (RFA), three were ablated after arrhythmia recurrence within a few minutes, and two were ablated after > 30 minutes without arrhythmia recurrence. Patients with catheter-induced trauma had higher rates of repeat ablations compared to patients without: 3/9 (33%) vs. 12/264 (0.45%), P = 0.009. The three patients with arrhythmia recurrence were managed differently during the first ablation procedure (immediate RFA, RFA following early recurrence, and delayed RFA). During the repeat procedure of these three patients, no catheter trauma occurred in two, and in one no arrhythmia was observed. CONCLUSIONS: Significant catheter-induced trauma occurred in 3.1% of OT arrhythmias ablations, both at the RVOT and LVOT. Arrhythmia suppression may last > 30 minutes and may interfere with procedural success. The optimal mode of management following trauma is undetermined.


Assuntos
Arritmias Cardíacas/etiologia , Ablação por Cateter/efeitos adversos , Ventrículos do Coração/fisiopatologia , Complicações Intraoperatórias/epidemiologia , Adulto , Idoso , Arritmias Cardíacas/epidemiologia , Arritmias Cardíacas/cirurgia , Ablação por Cateter/métodos , Eletrocardiografia/métodos , Feminino , Seguimentos , Ventrículos do Coração/cirurgia , Humanos , Incidência , Complicações Intraoperatórias/cirurgia , Masculino , Pessoa de Meia-Idade , Recidiva , Estudos Retrospectivos , Resultado do Tratamento
15.
Isr Med Assoc J ; 20(1): 43-50, 2018 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-29658207

RESUMO

BACKGROUND: Multiform fascicular tachycardia (FT) was recently described as a ventricular tachycardia (VT) that has a reentrant mechanism using multiple fascicular branches and produces alternate fascicular VT forms. Ablating the respective fascicle may cause a change in the reentrant circuit resulting in a change in morphology. Ablation of the septal fascicle is crucial for successful treatment. OBJECTIVES: To describe four cases of FT in which ablation induced a change in QRS morphologies and aggravated clinical course. METHODS: Four out of 57 consecutive FT cases at three institutions were retrospectively analyzed and found to involve multiform FT. These cases underwent electrophysiological study, fascicular potential mapping, and electroanatomical mapping. All patients initially had FT with right bundle branch block (RBBB) and superior axis morphology. RESULTS: Radiofrequency catheter ablation (RFCA) targeting the distal left posterior fascicle (LPF) resulted in a second VT with an RBBB-inferior axis morphology that sometimes became faster and/or incessant and/or verapamil-refractory in characteristics. RFCA in the upper septum abolished the second VT with no complications and uneventful long-term follow-up. CONCLUSIONS: The change in FT morphology during ablation may be associated with a change in clinical course when shifting from one route to another and may aggravate symptoms. Targeting of the proximal conduction system (such as bifurcation, LPF, left anterior fascicle, high septal/auxiliary pathway) may serve to solve this problem.


Assuntos
Fascículo Atrioventricular , Bloqueio de Ramo , Ablação por Cateter/métodos , Técnicas Eletrofisiológicas Cardíacas/métodos , Taquicardia Ventricular , Adulto , Fascículo Atrioventricular/fisiopatologia , Fascículo Atrioventricular/cirurgia , Bloqueio de Ramo/diagnóstico , Bloqueio de Ramo/fisiopatologia , Bloqueio de Ramo/cirurgia , Eletrocardiografia/métodos , Ventrículos do Coração/diagnóstico por imagem , Ventrículos do Coração/fisiopatologia , Humanos , Masculino , Pessoa de Meia-Idade , Taquicardia Ventricular/diagnóstico , Taquicardia Ventricular/etiologia , Taquicardia Ventricular/fisiopatologia , Taquicardia Ventricular/prevenção & controle , Tempo , Resultado do Tratamento
16.
Isr Med Assoc J ; 20(5): 269-276, 2018 05.
Artigo em Inglês | MEDLINE | ID: mdl-29761670

RESUMO

BACKGROUND: Limited information exists about detailed clinical characteristics and management of the small subset of Brugada syndrome (BrS) patients who had an arrhythmic event (AE). OBJECTIVES: To conduct the first nationwide survey focused on BrS patients with documented AE. METHODS: Israeli electrophysiology units participated if they had treated BrS patients who had cardiac arrest (CA) (lethal/aborted; group 1) or experienced appropriate therapy for tachyarrhythmias after prophylactic implantable cardioverter defibrillator (ICD) implantation (group 2). RESULTS: The cohort comprised 31 patients: 25 in group 1, 6 in group 2. Group 1: 96% male, mean CA age 38 years (range 13-84). Nine patients (36%) presented with arrhythmic storm and three had a lethal outcome; 17 (68%) had spontaneous type 1 Brugada electrocardiography (ECG). An electrophysiology study (EPS) was performed on 11 patients with inducible ventricular fibrillation (VF) in 10, which was prevented by quinidine in 9/10 patients. During follow-up (143 ± 119 months) eight patients experienced appropriate shocks, none while on quinidine. Group 2: all male, age 30-53 years; 4/6 patients had familial history of sudden death age < 50 years. Five patients had spontaneous type 1 Brugada ECG and four were asymptomatic at ICD implantation. EPS was performed in four patients with inducible VF in three. During long-term follow-up, five patients received ≥ 1 appropriate shocks, one had ATP for sustained VT (none taking quinidine). No AE recurred in patients subsequently treated with quinidine. CONCLUSIONS: CA from BrS is apparently a rare occurrence on a national scale and no AE occurred in any patient treated with quinidine.


Assuntos
Arritmias Cardíacas/epidemiologia , Arritmias Cardíacas/fisiopatologia , Síndrome de Brugada/epidemiologia , Síndrome de Brugada/fisiopatologia , Desfibriladores Implantáveis , Adolescente , Adulto , Idoso , Idoso de 80 Anos ou mais , Antiarrítmicos/uso terapêutico , Arritmias Cardíacas/terapia , Síndrome de Brugada/terapia , Estudos de Coortes , Comorbidade , Eletrocardiografia/métodos , Feminino , Seguimentos , Humanos , Israel/epidemiologia , Masculino , Pessoa de Meia-Idade , Quinidina/uso terapêutico , Adulto Jovem
17.
J Cardiovasc Electrophysiol ; 28(2): 240-248, 2017 02.
Artigo em Inglês | MEDLINE | ID: mdl-27763695

RESUMO

INTRODUCTION: A new imaging software (CARTO® Segmentation Module, Biosense Webster) allows preprocedural 3-D reconstruction of all heart chambers based on cardiac CT. We describe our initial experience with the new module during ablation of ventricular arrhythmias. METHODS AND RESULTS: Eighteen consecutive patients with idiopathic ventricular arrhythmias or ischemic ventricular tachycardia (VT) were studied. In the latter group, a combined endocardial and epicardial ablation was performed. Of the 14 patients with idiopathic arrhythmias, 12 were ablated in the outflow tract (OT), 1 in the midseptal left ventricle, and 1 at the left posterior fascicular area; acute successful ablation was achieved in 11 (78.6%) patients. The procedure was discontinued due to close proximity of the arrhythmia origin to the coronary arteries (CA) in 2 patients. Acute successful uncomplicated ablation was achieved in all 4 patients with ischemic VT. During ablation in the coronary cusps commissures, the CARTO® Segmentation Module accurately defined the cusps anatomy. The precise anatomic location provided by the module assisted in successfully ablating when information from activation mapping was not optimal, by ablating at the opposite side of the cusps. In addition, by demonstrating the precise location of the CA, it allowed safe ablation of arrhythmias that originated in close proximity to the CA both in the OT area and the epicardium, eliminating the need for repeat angiography. CONCLUSIONS: The CARTO® Segmentation Module is useful for accurate definition of the exact anatomic location of ventricular arrhythmias and for safely ablating them especially in close proximity to the CA.


Assuntos
Arritmias Cardíacas/cirurgia , Ablação por Cateter/métodos , Angiografia por Tomografia Computadorizada/métodos , Angiografia Coronária/métodos , Imageamento Tridimensional/métodos , Interpretação de Imagem Radiográfica Assistida por Computador/métodos , Design de Software , Cirurgia Assistida por Computador/métodos , Taquicardia Ventricular/cirurgia , Fibrilação Ventricular/cirurgia , Potenciais de Ação , Adulto , Idoso , Arritmias Cardíacas/diagnóstico por imagem , Arritmias Cardíacas/fisiopatologia , Técnicas de Imagem de Sincronização Cardíaca , Ablação por Cateter/efeitos adversos , Eletrocardiografia , Feminino , Frequência Cardíaca , Humanos , Masculino , Pessoa de Meia-Idade , Valor Preditivo dos Testes , Cirurgia Assistida por Computador/efeitos adversos , Taquicardia Ventricular/diagnóstico por imagem , Taquicardia Ventricular/fisiopatologia , Resultado do Tratamento , Fibrilação Ventricular/diagnóstico por imagem , Fibrilação Ventricular/fisiopatologia
18.
Europace ; 19(9): 1485-1492, 2017 Sep 01.
Artigo em Inglês | MEDLINE | ID: mdl-27702848

RESUMO

AIMS: Dual-coil leads were traditionally considered standard of care due to lower defibrillation thresholds (DFT). Higher complication rates during extraction with parallel progression in implantable cardioverter defibrillator (ICD) technology raised questions on dual coil necessity. Prior substudies found no significant outcome difference between dual and single coils, although using higher rates of DFT testing then currently practiced. We evaluated the temporal trends in implantation rates of single- vs. dual-coil leads and determined the associated adverse clinical outcomes, using a contemporary nation-wide ICD registry. METHODS AND RESULTS: Between July 2010 and March 2015, 6343 consecutive ICD (n = 3998) or CRT-D (n = 2345) implantation patients were prospectively enrolled in the Israeli ICD Registry. A follow-up of at least 1 year of 2285 patients was available for outcome analysis. The primary endpoint was all-cause mortality. Single-coil leads were implanted in 32% of our cohort, 36% among ICD recipients, and 26% among CRT-D recipients. Secondary prevention indication was associated with an increased rate of dual-coil implantation. A significant decline in dual-coil leads with reciprocal incline of single coils was observed, despite low rates of DFT testing (11.6%) during implantation, which also declined from 31 to 2%. In the multivariate Cox model analysis, dual- vs. single-coil lead implantation was not associated with an increased risk of mortality [hazard ratio (HR) = 1.23; P= 0.33], heart failure hospitalization (HR = 1.34; P=0.13), appropriate (HR = 1.25; P= 0.33), or inappropriate ICD therapy (HR = 2.07; P= 0.12). CONCLUSION: Real-life rates of single-coil lead implantation are rising while adding no additional risk. These results of single-coil safety are reassuring and obtained, despite low and contemporary rates of DFT testing.


Assuntos
Arritmias Cardíacas/terapia , Morte Súbita Cardíaca/prevenção & controle , Desfibriladores Implantáveis , Cardioversão Elétrica/instrumentação , Prevenção Primária/instrumentação , Idoso , Arritmias Cardíacas/complicações , Arritmias Cardíacas/diagnóstico , Arritmias Cardíacas/mortalidade , Causas de Morte , Distribuição de Qui-Quadrado , Morte Súbita Cardíaca/etiologia , Remoção de Dispositivo , Cardioversão Elétrica/efeitos adversos , Cardioversão Elétrica/mortalidade , Feminino , Humanos , Israel , Estimativa de Kaplan-Meier , Masculino , Pessoa de Meia-Idade , Análise Multivariada , Modelos de Riscos Proporcionais , Desenho de Prótese , Falha de Prótese , Sistema de Registros , Fatores de Risco , Fatores de Tempo , Resultado do Tratamento
19.
Europace ; 19(8): 1357-1363, 2017 Aug 01.
Artigo em Inglês | MEDLINE | ID: mdl-27733457

RESUMO

AIMS: Cardiac resynchronization therapy (CRT) with a defibrillator (CRT-D) has downsides of high cost and inappropriate shocks compared to CRT without a defibrillator (CRT-P). Recent data suggest that the survival benefit of implantable cardioverter defibrillator (ICD) therapy is attenuated in the older age group. We hypothesized that, among octogenarians eligible for cardiac resynchronization therapy, CRT-P confers similar morbidity and mortality benefits as CRT-D. METHODS AND RESULTS: We compared morbidity and mortality outcomes between consecutive octogenarian patients eligible for CRT therapy who underwent CRT-P implantation at Barzilai MC (n = 142) vs. those implanted with CRT-D for primary prevention indication who were prospectively enrolled in the Israeli ICD Registry (n = 104). Among the 246 study patients, mean age was 84 ± 3 years, 74% were males, and 66% had ischaemic cardiomyopathy. Kaplan-Meier survival analysis showed that at 5 years of follow-up the rate of all-cause mortality was 43% in CRT-P vs. 57% in the CRT-D group [log-rank P = 0.13; adjusted hazard ratio (HR) = 0.79, 95% CI 0.46-1.35, P = 0.37]. Kaplan-Meier analysis also showed no significant difference in the rates of the combined endpoint of heart failure or death (46 vs. 60%, respectively, log-rank P = 0.36; adjusted HR was 0.85, 95% CI 0.51-1.44, P = 0.55). A Cox proportional hazard with competing risk model showed that re-hospitalizations for cardiac cause were not different for the two groups (adjusted HR 1.35, 95% CI 0.7-2.6, P = 0.37). CONCLUSION: Our data suggest that, in octogenarians with systolic heart failure, CRT-P therapy is associated with similar morbidity and mortality outcomes as CRT-D therapy.


Assuntos
Dispositivos de Terapia de Ressincronização Cardíaca , Terapia de Ressincronização Cardíaca/mortalidade , Desfibriladores Implantáveis , Cardioversão Elétrica/instrumentação , Cardioversão Elétrica/mortalidade , Insuficiência Cardíaca/terapia , Prevenção Primária/instrumentação , Fatores Etários , Idoso de 80 Anos ou mais , Terapia de Ressincronização Cardíaca/efeitos adversos , Causas de Morte , Distribuição de Qui-Quadrado , Cardioversão Elétrica/efeitos adversos , Feminino , Insuficiência Cardíaca/diagnóstico , Insuficiência Cardíaca/mortalidade , Insuficiência Cardíaca/fisiopatologia , Humanos , Israel , Estimativa de Kaplan-Meier , Modelos Logísticos , Masculino , Readmissão do Paciente , Pontuação de Propensão , Modelos de Riscos Proporcionais , Estudos Prospectivos , Sistema de Registros , Fatores de Risco , Fatores de Tempo , Resultado do Tratamento
SELEÇÃO DE REFERÊNCIAS