Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 8 de 8
Filtrar
Mais filtros

Base de dados
Tipo de documento
Intervalo de ano de publicação
1.
Environ Sci Technol ; 46(15): 8025-34, 2012 Aug 07.
Artigo em Inglês | MEDLINE | ID: mdl-22788666

RESUMO

In June 2010, the NOAA WP-3D aircraft conducted two survey flights around the Deepwater Horizon (DWH) oil spill. The Gulf oil spill resulted in an isolated source of secondary organic aerosol (SOA) precursors in a relatively clean environment. Measurements of aerosol composition and volatile organic species (VOCs) indicated formation of SOA from intermediate-volatility organic compounds (IVOCs) downwind of the oil spill (Science2011, 331, doi 10.1126/science.1200320). In an effort to better understand formation of SOA in this environment, we present mass spectral characteristics of SOA in the Gulf and of SOA formed in the laboratory from evaporated light crude oil. Compared to urban primary organic aerosol, high-mass-resolution analysis of the background-subtracted SOA spectra in the Gulf (for short, "Gulf SOA") showed higher contribution of C(x)H(y)O(+) relative to C(x)H(y)(+) fragments at the same nominal mass. In each transect downwind of the DWH spill site, a gradient in the degree of oxidation of the Gulf SOA was observed: more oxidized SOA (oxygen/carbon = O/C ∼0.4) was observed in the area impacted by fresher oil; less oxidized SOA (O/C ∼0.3), with contribution from fragments with a hydrocarbon backbone, was found in a broader region of more-aged surface oil. Furthermore, in the plumes originating from the more-aged oil, contribution of oxygenated fragments to SOA decreased with downwind distance. Despite differences between experimental conditions in the laboratory and the ambient environment, mass spectra of SOA formed from gas-phase oxidation of crude oil by OH radicals in a smog chamber and a flow tube reactor strongly resembled the mass spectra of Gulf SOA (r(2) > 0.94). Processes that led to the observed Gulf SOA characteristics are also likely to occur in polluted regions where VOCs and IVOCs are coemitted.


Assuntos
Aerossóis , Poluentes Atmosféricos/análise , Espectrometria de Massas/métodos , Poluição por Petróleo , Compostos Orgânicos Voláteis/análise , Oxirredução
2.
Atmos Meas Tech ; 9(7): 3063-3093, 2016.
Artigo em Inglês | MEDLINE | ID: mdl-29619117

RESUMO

Natural emissions of ozone-and-aerosol-precursor gases such as isoprene and monoterpenes are high in the southeast of the US. In addition, anthropogenic emissions are significant in the Southeast US and summertime photochemistry is rapid. The NOAA-led SENEX (Southeast Nexus) aircraft campaign was one of the major components of the Southeast Atmosphere Study (SAS) and was focused on studying the interactions between biogenic and anthropogenic emissions to form secondary pollutants. During SENEX, the NOAA WP-3D aircraft conducted 20 research flights between 27 May and 10 July 2013 based out of Smyrna, TN. Here we describe the experimental approach, the science goals and early results of the NOAA SENEX campaign. The aircraft, its capabilities and standard measurements are described. The instrument payload is summarized including detection limits, accuracy, precision and time resolutions for all gas-and-aerosol phase instruments. The inter-comparisons of compounds measured with multiple instruments on the NOAA WP-3D are presented and were all within the stated uncertainties, except two of the three NO2 measurements. The SENEX flights included day- and nighttime flights in the Southeast as well as flights over areas with intense shale gas extraction (Marcellus, Fayetteville and Haynesville shale). We present one example flight on 16 June 2013, which was a daytime flight over the Atlanta region, where several crosswind transects of plumes from the city and nearby point sources, such as power plants, paper mills and landfills, were flown. The area around Atlanta has large biogenic isoprene emissions, which provided an excellent case for studying the interactions between biogenic and anthropogenic emissions. In this example flight, chemistry in and outside the Atlanta plumes was observed for several hours after emission. The analysis of this flight showcases the strategies implemented to answer some of the main SENEX science questions.

3.
Eur J Drug Metab Pharmacokinet ; 26(1-2): 123-8, 2001.
Artigo em Inglês | MEDLINE | ID: mdl-11554426

RESUMO

Pregabalin [PGB, (S)-3-isobutyl GABA, CI-1008] is a derivative of the inhibitory neurotransmitter g-aminobutyric acid (GABA). It has shown anticonvulsant, analgesia and anxiety activity in animal models. In this report, blood-brain barrier (BBB) influx and efflux of PGB were investigated with microdialysis at efficacious doses in rats. BBB influx (CLin) and efflux (CLout) permeability for pregabalin were 4.8 and 37.2 microL/min/g brain, respectively, following an intravenous infusion to rats. The results indicate that PGB is brain penetrable, supporting its anti-epilepsy and other CNS pharmacology. Significant anticonvulsant action of PGB was detected between 2 and 8 hr post oral dose, which is lag behind ECF drug concentrations lees. A PK/PD link model was used to describe the counter-clockwise hysteresis relationship between pregabalin brain ECF concentration and the anticonvulsant effect in rats. The resulting Ce (concentration in effect compartment) versus effect profile exhibits a sigmoidal curve and the calculated ECe50 and Keo values were 95.3 ng/mL and 0.0092 min-1, respectively. The small Keo value suggests that the effect is not directly proportional to the amount of pregabalin in the ECF compartment possibly due to inherent delay.


Assuntos
Aminas , Anticonvulsivantes/farmacologia , Anticonvulsivantes/farmacocinética , Encéfalo/metabolismo , Ácidos Cicloexanocarboxílicos , Antagonistas GABAérgicos/farmacologia , Antagonistas GABAérgicos/farmacocinética , Ácido gama-Aminobutírico/análogos & derivados , Ácido gama-Aminobutírico/farmacologia , Ácido gama-Aminobutírico/farmacocinética , Acetatos/administração & dosagem , Acetatos/farmacocinética , Animais , Anticonvulsivantes/administração & dosagem , Barreira Hematoencefálica , Eletrochoque , Antagonistas GABAérgicos/administração & dosagem , Gabapentina , Indicadores e Reagentes , Infusões Intravenosas , Microdiálise , Modelos Biológicos , Pregabalina , Ratos , Ratos Wistar , Convulsões/metabolismo , Ácido gama-Aminobutírico/administração & dosagem
4.
Stud Health Technol Inform ; 39: 598-607, 1997.
Artigo em Inglês | MEDLINE | ID: mdl-10173070

RESUMO

The key bimanual instrument tasks involved in laparoscopic surgery have been abstracted for use in a virtual reality surgical skills evaluator and trainer. The trainer uses two laparoscopic instruments mounted on a frame with position sensors which provide instrument movement data that is translated into interactive real time graphics on a PC (P133, 16 Mb RAM, graphics acceleration card). An accurately scaled operating volume of 10 cm3 is represented by a 3D cube on the computer screen. "Camera" position and size of target objects can be varied for different skill levels. Targets appear randomly within the operating volume according to the skill task and can be grasped and manipulated with the instruments. Accuracy and errors during the tasks and time to completion are logged. Mist VR has tutorial, training, examination, analysis and configuration modes. Six tasks have been selected and include combinations of instrument approach, target acquisition, target manipulation and placement, transfer between instruments, target contact with optional diathermy, and controlled instrument withdrawal/replacement. Tasks can be configured for varying degrees of difficulty and the configurations saved to a library for reuse. Specific task configurations can be assigned to individual students. In the examination mode the supervisor can select the tasks, repetitions and order and save to a specific file for that trainee. Progress can be assessed and there is the option for playback of the training session or examination. Data analyses permit overall, including task, and right or left hand performances to be quantified. Mist VR represents a significant advance over the subjective assessment of training performances with existing "plastic box" basic trainers.


Assuntos
Instrução por Computador/métodos , Avaliação Educacional/métodos , Cirurgia Geral/educação , Laparoscopia , Interface Usuário-Computador , Humanos
5.
Science ; 331(6022): 1295-9, 2011 Mar 11.
Artigo em Inglês | MEDLINE | ID: mdl-21393539

RESUMO

A large fraction of atmospheric aerosols are derived from organic compounds with various volatilities. A National Oceanic and Atmospheric Administration (NOAA) WP-3D research aircraft made airborne measurements of the gaseous and aerosol composition of air over the Deepwater Horizon (DWH) oil spill in the Gulf of Mexico that occurred from April to August 2010. A narrow plume of hydrocarbons was observed downwind of DWH that is attributed to the evaporation of fresh oil on the sea surface. A much wider plume with high concentrations of organic aerosol (>25 micrograms per cubic meter) was attributed to the formation of secondary organic aerosol (SOA) from unmeasured, less volatile hydrocarbons that were emitted from a wider area around DWH. These observations provide direct and compelling evidence for the importance of formation of SOA from less volatile hydrocarbons.

7.
Mass Spectrom Rev ; 26(2): 185-222, 2007.
Artigo em Inglês | MEDLINE | ID: mdl-17230437

RESUMO

The application of mass spectrometric techniques to the real-time measurement and characterization of aerosols represents a significant advance in the field of atmospheric science. This review focuses on the aerosol mass spectrometer (AMS), an instrument designed and developed at Aerodyne Research, Inc. (ARI) that is the most widely used thermal vaporization AMS. The AMS uses aerodynamic lens inlet technology together with thermal vaporization and electron-impact mass spectrometry to measure the real-time non-refractory (NR) chemical speciation and mass loading as a function of particle size of fine aerosol particles with aerodynamic diameters between approximately 50 and 1,000 nm. The original AMS utilizes a quadrupole mass spectrometer (Q) with electron impact (EI) ionization and produces ensemble average data of particle properties. Later versions employ time-of-flight (ToF) mass spectrometers and can produce full mass spectral data for single particles. This manuscript presents a detailed discussion of the strengths and limitations of the AMS measurement approach and reviews how the measurements are used to characterize particle properties. Results from selected laboratory experiments and field measurement campaigns are also presented to highlight the different applications of this instrument. Recent instrumental developments, such as the incorporation of softer ionization techniques (vacuum ultraviolet (VUV) photo-ionization, Li+ ion, and electron attachment) and high-resolution ToF mass spectrometers, that yield more detailed information about the organic aerosol component are also described.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA