RESUMO
Rhythmic masticatory muscle activity (RMMA), which is defined as three or more consecutive phasic bursts, accounts for a large part of sleep bruxism (SB). RMMA is thought to be characterized by co-contraction, a jaw muscle activity in which jaw-opening muscles contract during the active phase of jaw-closing muscles, which is different from that during mastication. However, there has been limited information about co-contraction. The aim of the present study was to clarify the amplitudes and patterns of jaw-opening muscle activity during the active phase of jaw-closing muscles in RMMA. Data from 14 healthy volunteers with bruxism, which was diagnosed by using polysomnographic recording with audio-video, were analysed. RMMA with electromyographic amplitudes of more than two times the baseline amplitude was selected. From the selected RMMA, burst groups consisting of five or more consecutive phasic bursts, including tonic bursts, were selected for analyses. Electromyographic activities during gum chewing were also recorded before sleeping. The minimum, maximum and average value of the amplitudes of jaw-opening muscle activity during the active phase of jaw-closing muscles were calculated. Jaw-opening muscle activity during the active phase of jaw-closing muscles in RMMA was closer to the baseline than that in gum chewing. The minimum, maximum and average values of amplitudes of jaw-opening muscle activity during the phase were significantly smaller than those of gum chewing. Contrary to our hypothesis prior to the study, the obtained results suggested that the pattern of electromyogram activity of jaw-opening and jaw-closing muscles in RMMA was not necessarily co-contraction.
Assuntos
Eletromiografia/métodos , Músculos da Mastigação/fisiopatologia , Bruxismo do Sono/diagnóstico , Adulto , Feminino , Humanos , Masculino , Voluntários , Adulto JovemRESUMO
BACKGROUND: AQP2 water channel is critical for urinary concentration in the kidney. Interestingly, AQP2 is abundantly excreted in the urine as extracellular vesicles (EVs), which is known to be a useful biomarker for water-balance disorders although the character of AQP2-enriched EVs is poorly understood including water channel function. METHODS: Human urine EVs were obtained by a differential centrifugation method. AQP2-bearing EVs were isolated by immunoprecipitation with an AQP2-specific antibody, and the proteins in the EVs were analyzed by LC-MS/MS proteomic analysis. Osmotic water permeability (Pf) of the AQP2-rich EVs was measured by a stopped-flow method monitoring scattered light intensity in response to outwardly directed osmotic gradient. RESULTS: Sequential centrifugation of human urine showed that AQP2 was present predominantly (80%) in low-density EVs (160,000 g), whereas negligible amount in high-density EVs (17,000 g). Proteomic analysis of the AQP2-bearing EVs identified 137 proteins, mostly in the endosome pathway, including the components of ESCRT (endosomal sorting complex required transporter)-I, II, III. Pf value of the 160,000 g EVs was 4.75 ± 0.38 × 10-4 cm s-1 (mean ± SE) with the activation energy of 3.51 kcal mol-1 which was inhibited with 0.3 mM HgCl2 by 63%, suggesting a channel-mediated water transport. Moreover, Pf value showed a significant correlation with the abundance of AQP2 protein in EVs. CONCLUSION: Taken together, AQP2 is localized predominantly to urinary exosomes with preserved water channel activities.
Assuntos
Aquaporina 2/urina , Exossomos , Rim/fisiologia , Proteômica , Humanos , Permeabilidade , Água/metabolismoRESUMO
PURPOSE: No definitive associations or causal relationships have been determined between obstructive sleep apnea-hypopnea (OSAH) and sleep bruxism (SB). The purpose of this study was to investigate, in a population reporting awareness of both OSAH and SB, the associations between each specific breathing and jaw muscle event. METHODS: Polysomnography and audio-video data of 59 patients reporting concomitant OSAH and SB history were analyzed. Masseteric bursts after sleep onset were scored and classified into three categories: (1) sleep rhythmic masticatory muscle activity with SB (RMMA/SB), (2) sleep oromotor activity other than RMMA/SB (Sleep-OMA), and (3) wake oromotor activity after sleep onset (Wake-OMA). Spearman's rank correlation coefficient analyses were performed. Dependent variables were the number of RMMA/SB episodes, RMMA/SB bursts, Sleep-OMA, and Wake-OMA; independent variables were apnea-hypopnea index (AHI), arousal index(AI), body mass index(BMI), gender, and age. RESULTS: Although all subjects had a history of both SB and OSAH, sleep laboratory results confirmed that these conditions were concomitant in only 50.8 % of subjects. Moderate correlations were found in the following combinations (p < 0.05); RMMA/SB episode with AI, RMMA/SB burst with AI and age, Sleep-OMA burst with AHI, and Wake-OMA burst with BMI. CONCLUSIONS: The results suggest that (1) sleep arousals in patients with concomitant SB and OSAH are not strongly associated with onset of RMMA/SB and (2) apnea-hypopnea events appear to be related to higher occurrence of other types of sleep oromotor activity, and not SB activity. SB genesis and OSAH activity during sleep are probably influenced by different mechanisms.
Assuntos
Polissonografia , Apneia Obstrutiva do Sono/diagnóstico , Bruxismo do Sono/diagnóstico , Adulto , Idoso , Comorbidade , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Apneia Obstrutiva do Sono/epidemiologia , Bruxismo do Sono/epidemiologia , Estatística como AssuntoRESUMO
Purpose This study aimed to measure masseter muscle activity throughout the day in outpatients suspected of having awake bruxism (AB) and/or sleep bruxism (SB) and examine the relationship between AB and SB by comparing muscle activity during daytime wakefulness and nighttime sleep.Methods Fifty outpatients with suspected SB and/or AB participated in this study. A single-channel wearable electromyogram (EMG) device was used for EMG recording. The selected EMG bursts were divided into bursts during sleep (S-bursts) and bursts during awake state (A-bursts). The number of bursts per hour, average burst duration, and ratio of burst peak value to maximum voluntary contraction were calculated for both the S- and A-bursts. These values of the S- and A-bursts were then compared, and the correlations between them were analyzed. Additionally, the ratios of phasic and tonic bursts in the S- and A-bursts were compared.Results The number of bursts per hour was significantly higher for A-bursts than for S-bursts. No significant correlation was found between the numbers of S- and A-bursts. The ratio of phasic bursts was large and that of tonic bursts was small in both the S- and A-bursts. A comparison of the S- and A-bursts showed that the S-bursts had a significantly lower ratio of phasic bursts and higher ratio of tonic bursts than the A-bursts.Conclusions The number of masseteric EMG bursts during wakefulness did not show any association with that during sleep. It became clear that sustained muscle activity was not dominant in AB.
Assuntos
Bruxismo do Sono , Dispositivos Eletrônicos Vestíveis , Humanos , Músculo Masseter/fisiologia , Vigília , Sono/fisiologia , Bruxismo do Sono/diagnóstico , Eletromiografia/métodosRESUMO
PURPOSE: This study aimed to elucidate the relationship between diurnal masseter muscle activity and awareness of diurnal awake bruxism (d-AB) by conducting a comparative analysis of electromyographic (EMG) data from individuals with and without awareness of diurnal awake bruxism (d-AB), utilizing EMG data gathered from multiple subjects. METHODS: Unilateral masseter electromyography (EMG) recordings were performed during the daytime using an ultraminiature wearable EMG device. A total of 119 participants (59 with awareness of diurnal tooth clenching [d-TC] and 60 without awareness of d-TC) were included. Waveforms longer than 0.25 s with the two amplitude conditions, exceeding twice the baseline and >5% of maximum voluntary clenching, were extracted. In addition, the number of bursts and episodes (groups of bursts), burst duration, and burst peak amplitude were calculated for each participant. RESULTS: There were no significant differences in the EMG parameters between the groups with and without awareness of d-TC. Additionally, the frequency distribution of the number of EMG waveforms exhibited wide ranges and substantial overlap between the two groups. CONCLUSIONS: The variability in the number of bursts and episodes, burst peak amplitude, and burst duration among subjects suggests the need for an objective classification of d-AB severity based on EMG values. The absence of significant differences and large overlap in frequency distributions between the groups with and without awareness of d-TC indicate difficulty in predicting muscle activity solely based on awareness of d-AB.
Assuntos
Conscientização , Bruxismo , Eletromiografia , Músculo Masseter , Vigília , Humanos , Músculo Masseter/fisiopatologia , Músculo Masseter/fisiologia , Bruxismo/fisiopatologia , Masculino , Feminino , Adulto , Vigília/fisiologia , Conscientização/fisiologia , Ritmo Circadiano/fisiologia , Adulto Jovem , Pessoa de Meia-IdadeRESUMO
There is some evidence suggesting that obstructive sleep apnea-hypopnea syndrome is concomitant with sleep bruxism. The aim of this study was to investigate the temporal association between sleep apnea-hypopnea events and sleep bruxism events. In an open observational study, data were gathered from 10 male subjects with confirmed obstructive sleep apnea-hypopnea syndrome and concomitant sleep bruxism. Polysomnography and audio-video recordings were performed for 1 night in a sleep laboratory. Breathing, brain, heart and masticatory muscle activity signals were analysed to quantify sleep and sleep stage duration, and number and temporal distribution of apnea-hypopnea events and sleep bruxism events. Apnea-hypopnea events were collected within a 5-min time window before and after sleep bruxism events, with the sleep bruxism events as the pivotal reference point. Two temporal patterns were analysed: (i) the interval between apnea-hypopnea events termination and sleep bruxism events onset, called T1; and (ii) the interval between sleep bruxism events termination and apnea-hypopnea events onset, called T2. Of the intervals between sleep bruxism events and the nearest apnea-hypopnea event, 80.5% were scored within 5 min. Most intervals were distributed within a period of <30 s, with peak at 0-10 s. The T1 interval had a mean length of 33.4 s and was significantly shorter than the T2 interval (64.0 s; P < 0.05). Significantly more sleep bruxism events were scored in association with the T1 than the T2 pattern (P < 0.05). Thus, in patients with concomitant obstructive sleep apnea-hypopnea syndrome and sleep bruxism, most sleep bruxism events occurred after sleep apnea-hypopnea events, suggesting that sleep bruxism events occurring close to sleep apnea-hypopnea events is a secondary form of sleep bruxism.
RESUMO
OBJECTIVE: The current state of portable/wearable electromyographic (EMG) devices for assessment of bruxism was reviewed. METHODS: A search of full-text articles relevant to portable/wearable EMG devices capable of being used at home was performed. The data source used was MEDLINE via PubMed from January 1970 to July 2019. RESULTS: There were nine kinds of wearable EMG devices capable of being used under unrestrained conditions. Ultra-miniaturized wearable EMG devices with a level of performance equivalent to that of conventional stationary EMG devices have been developed and are being used during sleep and in the daytime. The devices have a high level of diagnostic accuracy for sleep bruxism. A definite cut-off value for awake bruxism has not been established. DISCUSSION: Assessment of sleep bruxism with a high level of accuracy can be performed using a portable/wearable EMG device. However, a definite cut-off value is required for assessment of awake bruxism.
Assuntos
Bruxismo , Bruxismo do Sono , Dispositivos Eletrônicos Vestíveis , Humanos , Bruxismo/diagnóstico , Bruxismo do Sono/diagnóstico , Vigília , Eletromiografia , SonoRESUMO
OBJECTIVE: This study aimed to clarify frequency distribution of number and peak amplitude of electromyographic (EMG) waveforms of sleep bruxism (SB) in outpatients with clinical diagnosis of SB (probable bruxer: P-bruxer). METHODS: Subjects were 40 P-bruxers. Masseteric EMG during sleep was measured at home using a wearable EMG system. EMG waveforms with amplitude of more than two times the baseline and with duration of 0.25 s were extracted as SB bursts. Clusters of bursts, i.e. SB episodes, were also scored. RESULTS: There were large variations among the subjects in numbers of SB bursts and episodes and in burst peak amplitude. As for burst peak amplitude within a subject, a wide right-tailed frequency distribution was shown with the highest frequency at the class of 5-10% maximum voluntary contraction. CONCLUSION: The number and amplitude of SB waveforms for P-bruxers were distributed over a wide range, indicating the existence of large individual differences.
RESUMO
The aim of this literature review was to summarize the clinical characteristics and symptoms of temporomandibular joint diseases, and to discuss the associations between temporomandibular joint diseases and categorization of malocclusion. Electronic literature searches were performed using the PubMed database. The authors established a differential diagnostic method for temporomandibular joint diseases related to malocclusion. A literature search using PubMed yielded 213 texts, of which based on exclusion criteria, 28 were included in this study. Malocclusions were categorized into 5 types. The authors suggested a diagnostic tree of temporomandibular joint diseases based on the types of malocclusion and 4 variables in clinical characteristics and symptoms. Clinicians treating malocclusions must attempt to clarify the cause of the occlusal condition. If caused by temporomandibular joint disease, it is important to make a proper differential diagnosis at first, and not to overlook the causative disease. Further clinical knowledge of associations between temporomandibular joint diseases and malocclusions should be accumulated, and the diagnostic tree should be improved based on new information.
Assuntos
Má Oclusão , Transtornos da Articulação Temporomandibular , Diagnóstico Diferencial , Humanos , Conhecimento , Má Oclusão/diagnóstico , Má Oclusão/terapia , PubMed , Articulação Temporomandibular , Transtornos da Articulação Temporomandibular/complicações , Transtornos da Articulação Temporomandibular/diagnósticoRESUMO
Evaluation of sleep bruxism (SB) in clinical practice is currently conducted based on clinical findings, i.e., clinical diagnostic criteria consisting of medical interview, findings of tooth wear, and symptoms of temporomandibular joint (TMJ) and muscles. However, there are many unclear points about validity of the criteria. In this study, validity tests were conducted to clarify the accuracy of the clinical diagnostic criteria for SB by comparison with a reference standard using a single-channel masseteric electromyogram (EMG) obtained with ultraminiature electromyographic devices. The subjects included 30 'probable' bruxers (P-bruxers) who were clinically diagnosed as having SB and 30 non-bruxers. EMG was recorded during sleep under unrestrained and accustomed condition at each subject's home using ultraminiature cordless EMG devices. Bursts with amplitudes of more than 5%, 10%, 20% of the maximum voluntary contraction (MVC) value (EMG-burst-5%, EMG-burst-10%, and EMG-burst-20%) and episodes of sleep bruxism (EMG-episode) were selected for analyses. In all conditions for burst selection, the P-bruxer group showed a significantly larger number of bursts and episodes than those in the non-bruxer group. Accuracy of the clinical diagnosis criteria was 66.7% with the reference standard using EMG-burst-5%/h and 58.3% with that using EMG-episodes/h. By applying single-channel EMG as the reference standard, we were able to conduct validity tests of clinical diagnostic criteria with a larger sample. It was clarified that the level of accuracy of clinical diagnostic criteria for SB were not high despite using the combination of an interview and clinical findings.
RESUMO
Objective: Assessments of diurnal awake bruxism (d-AB) using masseteric electromyogram (EMG) during various lengths of measurement time within a day were examined as the first step of research to clarify the minimum measurement time required for assessment of d-AB by subject.Methods: Subjects were 33 outpatients. Assessment of d-AB by EMG during partial measurement time (PMT) with durations ranging from 30 minutes to 6 hours was compared with that during total measurement time (TMT) used as the reference standard.Results: No significant difference was found between TMT data and PMT data. There were significant correlations in all combinations between TMT data and PMT data. Accuracy was 0.909 or more for 2.5 hours or longer.Discussion: The results suggest that the tendency of daytime muscle activity in 1 day can be assessed even by using masseteric EMG data obtained during a relatively short measurement time.
Assuntos
Bruxismo , Bruxismo do Sono , Bruxismo/diagnóstico , Eletromiografia , Humanos , Músculo Masseter , Bruxismo do Sono/diagnóstico , VigíliaRESUMO
PURPOSE: We aimed to clarify the relationship between the number of sleep bruxism (SB) bursts at home and in a laboratory equipped with polysomnography with audio-video recording (PSG-AV). We applied an identical single-channel wearable electromyography (EMG) device for both types of SB burst scorings. METHODS: The subjects were 20 healthy student volunteers (12 men and 8 women; mean age, 21.9 years) who were clinically diagnosed with bruxism based on the criteria set forth by the International Classification of Sleep Disorders (ICSD-2). We used a wearable EMG device attached to the masseteric area (the FLA-500-SD [FLA]), for scoring SB bursts at home and in the laboratory. PSG-AV was set within the laboratory environment as well. The mean interval for both sleep studies was 28.8 days. EMG bursts with amplitudes greater than twice the baseline amplitude and with durations of longer than 0.25 s were selected. EMG bursts with amplitudes ≥5% MVC (maximum voluntary contraction), ≥10% MVC, and ≥20% MVC were selected as well. A cluster of bursts was defined as an episode. RESULTS: In all the conditions for selecting EMG bursts specified above, the number of SB bursts and episodes recorded under laboratory conditions was statistically significantly smaller than that recorded at home. There were no statistically significant differences between the data obtained on the first and second recording days. CONCLUSION: The results of this study suggest that the unfamiliar environment of a sleep laboratory equipped with PSG-AV affects the emergence of SB as compared with home conditions.
Assuntos
Polissonografia , Bruxismo do Sono , Sono , Adulto , Eletromiografia , Feminino , Voluntários Saudáveis , Humanos , Masculino , Músculo Masseter , Polissonografia/métodos , Bruxismo do Sono/diagnóstico , Dispositivos Eletrônicos Vestíveis , Adulto JovemRESUMO
PURPOSE: The purpose of this study was to clarify the validity of assessment of sleep bruxism (SB) by using single-channel electromyogram (EMG) and a cut-off value with optimum sensitivity and specificity. METHODS: The subjects were twenty volunteers with clinical diagnosis of SB. Assessment by masseteric EMG data only by using a wearable EMG was compared with reference standard assessment by masseteric EMG data using polysomnography with audio-visual recording (PSG-AV). From EMG activities recorded by single-channel EMG, bursts of more than two times the baseline amplitude with a duration of 0.25s or more were selected by a burst unit (EMG-burst-all). Furthermore, from EMG-burst-all, bursts that were more than 5-20% of the maximum voluntary contraction value (EMG-burst-5%, EMG-burst-10%, EMG-burst-20%) were selected. By an episode unit, phasic, tonic, and mixed episodes were selected by single-channel EMG (EMG-episodes). Among the EMG-episodes, further, reference standard episodes of SB (PSG-episodes) were selected by PSG-AV assessment. RESULTS: Sixteen subjects were diagnosed as bruxers based on PSG-AV (PSG-episodes/h >2). By a burst unit and an episode unit, there were significant correlations between assessment variables of SB by single-channel EMG and PSG-AV except for EMG-burst-20%/h. When the cut-off value in EMG-episodes/h was 5.5/h for sleep bruxers, both sensitivity and specificity were 100%. As for variables by a burst unit, EMG-burst-all/h and EMG-burst-5% had higher values of sensitivity and specificity. CONCLUSIONS: The results suggested that single-channel EMG is valid for diagnosis of SB if a cut-off value that is appropriate for single-channel EMG is used.
Assuntos
Bruxismo do Sono , Dispositivos Eletrônicos Vestíveis , Eletromiografia , Humanos , Músculo Masseter , PolissonografiaRESUMO
PURPOSE: We describe the characteristics of a new data-logger-type ultraminiature electromyogram (EMG) system (FLA-500-SD) and methods used for recording and we show its potential in clinical applications by presenting an example of a clinical case. METHOD: FLA contains electrodes, an amplifier, 12-bit analog-to-digital (A/D) converter at a sampling frequency of 1kHz, 16-bit CPU, a 3.7-V coin-shaped lithium battery, and a micro SD card. The size of FLA is 37.0×23.5×8.6mm, and its weight is 6g (9g with a battery inserted). The device is wearable and patients can attach the device and operate it by themselves in daily life. Data recorded in the micro SD card are transferred to a personal computer and analyzed. Although the device is ultraminiature and wearable, it has the capacity for recording a precise and clear masseteric surface electromyogram that is not inferior to that recorded by conventional stationary-type EMG recording systems. CONCLUSIONS: To our knowledge, the device is the smallest and lightest device with capacity for the longest consecutive measuring time as a data-logger-type electromyograph with built-in electrodes and memory. The device is useful for analyses of masseteric activity during the whole day. In the future, it is expected that applications of the device will expanded to observation, evaluation and diagnosis of normal or abnormal gnathic functions, e.g., assessment of sleep and awake bruxism and observation of the chewing state in daily life.
Assuntos
Eletromiografia/instrumentação , Músculo Masseter/fisiologia , Microeletrodos , Monitorização Fisiológica/instrumentação , Dispositivos Eletrônicos Vestíveis , Bruxismo/diagnóstico , Bruxismo/fisiopatologia , Eletromiografia/métodos , Humanos , Mastigação/fisiologia , Monitorização Fisiológica/métodosRESUMO
OBJECTIVES: The aim of this study was to elucidate characteristics of rhythmic masticatory muscle activity (RMMA) during sleep by comparing masseteric EMG (electromyogram) activities of RMMA with gum chewing. METHOD: The parts of five or more consecutive phasic bursts in RMMA of 23 bruxers were analyzed. Wilcoxon signed-rank test for matched pairs and Spearman's correlation coefficient by the rank test were used for statistical analysis. RESULTS: Root mean square value of RMMA phasic burst was smaller than that during gum chewing, but correlates to that of gum chewing. The cycle of RMMA was longer than that of gum chewing due to the longer burst duration of RMMA, and variation in the cycles of RMMA was wider. DISCUSSION: These findings suggest that the longer but smaller EMG burst in comparison with gum chewing is one of the characteristics of RMMA. The relation between size of RMMA phasic bursts and gum chewing is also suggested.
Assuntos
Mastigação/fisiologia , Músculos da Mastigação/fisiopatologia , Bruxismo do Sono/fisiopatologia , Adulto , Goma de Mascar , Eletromiografia , Feminino , Humanos , Masculino , Músculos da Mastigação/fisiologiaRESUMO
PURPOSE: The purpose of this study was to clarify the day-to-day variations of salivary cortisol to discuss the appropriate timing for collecting saliva in a day for stress evaluation. MATERIALS AND METHODS: Saliva samples from twelve healthy adults were collected by means of Salivette(®) (SARSTEDT Co.) three times per day, immediately after awakening (Time1), 6:00 PM (Time2) and 30 min before going to bed (Time3), on 5 nonconsecutive days. Cortisol concentration was measured using a radioimmunoassay. RESULTS: Salivary cortisol concentration showed the larger value at Time1 than that at Time2. The mean value of %CV for day-to-day variation showed the smallest value at Time1 (mean: 43.1%) and the largest value at Time3 (mean: 100.3%). There were significant differences in %CV value between Time1 and Time3, Time2 (mean: 64.1%) and Time3. CONCLUSIONS: There are considerable day-to-day variations in salivary cortisol concentration measurements. From the viewpoint of day-to-day variation, collecting saliva immediately after awakening in the morning is thought to be more advantageous for evaluating cortisol concentration.
Assuntos
Ritmo Circadiano/fisiologia , Hidrocortisona/análise , Saliva/química , Estresse Psicológico/diagnóstico , Adulto , Biomarcadores/análise , Feminino , Humanos , Sistema Hipotálamo-Hipofisário/fisiologia , Masculino , Sistema Hipófise-Suprarrenal , Adulto JovemRESUMO
PURPOSE: To elucidate the influence of motion and posture of head on the newly developed ultraminiature cordless bruxism measurement system (BMS), we examined masseteric electromyographic (EMG) data of BMS during turning-over movements in bed in comparison with those of a conventional polygraph system (PG). METHODS: Twelve healthy subjects lay on their back and then turned to the right (right turn, 90 degrees) and then to the left (left turn, 180 degrees). Maximum amplitudes and root mean square (RMS) values of EMG data were calculated during the phase of turning movements. The data were high-pass filtered at 10 Hz, 30 Hz, 50 Hz, and 100 Hz. RESULTS: Artifact signals were visibly observed in PG measurement for all subjects and in BMS measurement for three subjects. Maximum amplitudes during right turn measured by BMS were significantly smaller than those measured by PG, while there was no significant difference during left turn. During right turn, RMS values high-pass filtered at 10 Hz obtained by BMS were significantly smaller than those obtained by PG, while there was no significant difference between the data obtained by the two devices at the other cut-off frequencies. During left turn, there was no significant difference between RMS values obtained by the two devices. CONCLUSIONS: Although BMS data were slightly affected by motion and posture of head during simulated sleep-turning, it was suggested that motion artifact of signals during BMS measurements is equivalent to or less than that during PG measurements, and BMS is thought to be suitable to measure sleep bruxism.
Assuntos
Análise do Estresse Dentário/instrumentação , Análise do Estresse Dentário/métodos , Eletromiografia/instrumentação , Eletromiografia/métodos , Cabeça/fisiologia , Músculo Masseter/fisiologia , Miniaturização , Movimento (Física) , Postura/fisiologia , Bruxismo do Sono/diagnóstico , Adulto , Feminino , Humanos , Masculino , Polissonografia , Adulto JovemRESUMO
To verify validity of a newly developed ultraminiature EMG measurement system (BMS), the ability of BMS to record masseteric EMG was compared with that of a conventional polygraph system (PG) in the daytime. Effective distance between the transmitter unit and receiver unit of BMS was also examined. Subjects were 12 healthy volunteers. During tapping, maximum clenching, and gum chewing of all subjects, distinct bursts were observed in EMG recorded by BMS as well as PG. RMS values of maximum clenching measured by BMS and PG showed a linear and significant correlation, and there was no significant difference between the data of BMS and PG. When distance between the transmitter unit and receiver unit of BMS was 100 cm or less, no artifact signal was observed. Having obtained these findings suggesting ability for precise measurement in the daytime, we are planning to use BMS in home sleep studies in the next step.