Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 24
Filtrar
1.
J Synchrotron Radiat ; 29(Pt 6): 1407-1413, 2022 Nov 01.
Artigo em Inglês | MEDLINE | ID: mdl-36345748

RESUMO

X-ray diffraction with high spatial resolution is commonly used to characterize (poly)crystalline samples with, for example, respect to local strain, residual stress, grain boundaries and texture. However, the investigation of highly absorbing samples or the simultaneous assessment of high-Z materials by X-ray fluorescence have been limited due to the utilization of low photon energies. Here, a goniometer-based setup implemented at the P06 beamline of PETRA III that allows for micrometre spatial resolution with a photon energy of 35 keV and above is reported. A highly focused beam was achieved by using compound refractive lenses, and high-precision sample manipulation was enabled by a goniometer that allows up to 5D scans (three rotations and two translations). As experimental examples, the determination of local strain variations in martensitic steel samples with micrometre spatial resolution, as well as the simultaneous elemental distribution for high-Z materials in a thin-film solar cell, are demonstrated. The proposed approach allows users from the materials-science community to determine micro-structural properties even in highly absorbing samples.

2.
Opt Express ; 30(19): 33652-33663, 2022 Sep 12.
Artigo em Inglês | MEDLINE | ID: mdl-36242395

RESUMO

X-ray ptychography is a cutting edge imaging technique providing ultra-high spatial resolutions. In ptychography, phase retrieval, i.e., the recovery of a complex valued signal from intensity-only measurements, is enabled by exploiting a redundancy of information contained in diffraction patterns measured with overlapping illuminations. For samples that are considerably larger than the probe we show that during the iteration the bulk information has to propagate from the sample edges to the center. This constitutes an inherent limitation of reconstruction speed for algorithms that use a flat initialization. Here, we experimentally demonstrate that a considerable improvement of computational speed can be achieved by utilizing a low resolution sample wavefront retrieved from measured diffraction patterns as object initialization. In addition, we show that this approach avoids phase artifacts associated with large phase gradients and may alleviate the requirements on phase structure within the probe. Object initialization is computationally fast, potentially beneficial for bulky sample and compatible with flat samples. Therefore, the presented approach is readily adaptable with established ptychographic reconstruction algorithms implying a wide spread use.

3.
Phys Rev Lett ; 118(26): 265501, 2017 Jun 30.
Artigo em Inglês | MEDLINE | ID: mdl-28707948

RESUMO

Small angle x-ray scattering has been proven to be a valuable method for accessing structural information below the spatial resolution limit implied by direct imaging. Here, we theoretically derive the relation that links the subpixel differential phase signal provided by the sample to the moments of scattering distributions accessible by refraction sensitive x-ray imaging techniques. As an important special case we explain the scatter or dark-field contrast in terms of the sample's phase signal. Further, we establish that, for binary phase objects, the nth moment scales with the difference of the refractive index decrement to the power of n. Finally, we experimentally demonstrate the utility of the moments by quantitatively determining the particle sizes of a range of powders with a laboratory-based setup.

4.
Radiology ; 277(1): 64-72, 2015 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-25942503

RESUMO

PURPOSE: To investigate the accuracy of x-ray grating interferometry phase-contrast (PC) imaging for the characterization of human coronary artery plaque. MATERIALS AND METHODS: PC and conventional absorption computed tomographic (CT) imaging was performed ex vivo in this institutional review board-approved study in 40 human coronary artery segments by using a synchrotron radiation source. Qualitative analyses and calculations of image quality (McNemar test), plaque components (McNemar test), and plaque classification (Cohen κ test) according to the American Heart Association classification were performed in 38 plaques detected at histopathologic examination (reference standard). Quantitative measurements of plaque components (ie, collagen, lipids, smooth muscle, and calcifications) were compared among PC and absorption images by using analysis of variance for repeated measures with post hoc Bonferroni correction. RESULTS: Image quality was superior in PC (median image score, 1) in all cases (100%) compared with absorption imaging (median image score, 3) (P < .001). Plaque components were detected by means of PC without significant differences (seven of seven calcifications, 22 of 22 plaques with collagen and smooth muscle cells, P > .99; 29 of 29 plaques with lipids, P = .10) with histopathologic findings, whereas absorption imaging was used to detect calcifications (seven of seven, P > .99) without statistical differences only (nine of 29 plaques with lipids, 0 of 22 plaques with collagen and smooth muscle cells, P < .001). Accuracy for plaque stage assessment with PC (early vs advanced) was 100%, and characterization was correct in 33 of 38 plaques (87%), while conventional absorption imaging allowed correct characterization of seven plaques only (18%, P < .001). PC CT numbers were significantly different (P < .05) for all plaque components (mean for calcifications, 1236 HU ± 69; collagen, 78 HU ± 24; lipids, -18 HU ± 23; and smooth muscle cells, 34 HU ± 12), whereas absorption images showed significant differences (P < .001) between calcifications (1336 HU ± 241) and other plaque components, but not for collagen (22 HU ± 13), lipids (-15 HU ± 14), and smooth muscle (13 HU ± 9) (P > .99). CONCLUSION: PC imaging allows accurate characterization of human coronary artery plaques and quantitative assessment of plaque components, thereby outperforming absorption imaging.


Assuntos
Doença da Artéria Coronariana/diagnóstico por imagem , Doença da Artéria Coronariana/patologia , Placa Aterosclerótica/diagnóstico por imagem , Placa Aterosclerótica/patologia , Tomografia Computadorizada por Raios X , Adulto , Cadáver , Doença da Artéria Coronariana/complicações , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Placa Aterosclerótica/complicações , Reprodutibilidade dos Testes , Adulto Jovem
5.
J Synchrotron Radiat ; 21(Pt 3): 613-22, 2014 May.
Artigo em Inglês | MEDLINE | ID: mdl-24763652

RESUMO

Phase-sensitive X-ray imaging shows a high sensitivity towards electron density variations, making it well suited for imaging of soft tissue matter. However, there are still open questions about the details of the image formation process. Here, a framework for numerical simulations of phase-sensitive X-ray imaging is presented, which takes both particle- and wave-like properties of X-rays into consideration. A split approach is presented where we combine a Monte Carlo method (MC) based sample part with a wave optics simulation based propagation part, leading to a framework that takes both particle- and wave-like properties into account. The framework can be adapted to different phase-sensitive imaging methods and has been validated through comparisons with experiments for grating interferometry and propagation-based imaging. The validation of the framework shows that the combination of wave optics and MC has been successfully implemented and yields good agreement between measurements and simulations. This demonstrates that the physical processes relevant for developing a deeper understanding of scattering in the context of phase-sensitive imaging are modelled in a sufficiently accurate manner. The framework can be used for the simulation of phase-sensitive X-ray imaging, for instance for the simulation of grating interferometry or propagation-based imaging.

6.
Phys Rev Lett ; 113(2): 020801, 2014 Jul 11.
Artigo em Inglês | MEDLINE | ID: mdl-25062159

RESUMO

Multiple scattering represents a challenge for numerous modern tomographic imaging techniques. In this Letter, we derive an appropriate line integral that allows for the tomographic reconstruction of angular resolved scattering distributions, even in the presence of multiple scattering. The line integral is applicable to a wide range of imaging techniques utilizing various kinds of probes. Here, we use x-ray grating interferometry to experimentally validate the framework and to demonstrate additional structural sensitivity, which exemplifies the impact of multiple scattering tomography.


Assuntos
Interferometria/métodos , Tomografia Computadorizada por Raios X/métodos , Modelos Teóricos , Espalhamento de Radiação
7.
Opt Express ; 21(5): 5511-28, 2013 Mar 11.
Artigo em Inglês | MEDLINE | ID: mdl-23482123

RESUMO

Differential phase-contrast is a recent technique in the context of X-ray imaging. In order to reduce the specimen's exposure time, we propose a new iterative algorithm that can achieve the same quality as FBP-type methods, while using substantially fewer angular views. Our approach is based on 1) a novel spline-based discretization of the forward model and 2) an iterative reconstruction algorithm using the alternating direction method of multipliers. Our experimental results on real data suggest that the method allows to reduce the number of required views by at least a factor of four.

8.
Opt Express ; 21(26): 32340-8, 2013 Dec 30.
Artigo em Inglês | MEDLINE | ID: mdl-24514826

RESUMO

In this paper we introduce a new reconstruction algorithm for X-ray differential phase-contrast Imaging (DPCI). Our approach is based on 1) a variational formulation with a weighted data term and 2) a variable-splitting scheme that allows for fast convergence while reducing reconstruction artifacts. In order to improve the quality of the reconstruction we take advantage of higher-order total-variation regularization. In addition, the prior information on the support and positivity of the refractive index is considered, which yields significant improvement. We test our method in two reconstruction experiments involving real data; our results demonstrate its potential for in-vivo and medical imaging.


Assuntos
Algoritmos , Artefatos , Intensificação de Imagem Radiográfica/métodos , Interpretação de Imagem Radiográfica Assistida por Computador/métodos , Tomografia/métodos , Difração de Raios X/métodos
9.
Opt Lett ; 38(22): 4605-8, 2013 Nov 15.
Artigo em Inglês | MEDLINE | ID: mdl-24322085

RESUMO

Phase contrast x-ray imaging (PCXI) is a promising imaging modality, capable of sensitively differentiating soft tissue structures at high spatial resolution. However, high sensitivity often comes at the cost of a long exposure time or multiple exposures per image, limiting the imaging speed and possibly increasing the radiation dose. Here, we demonstrate a PCXI method that uses a single short exposure to sensitively capture sample phase information, permitting high speed x-ray movies and live animal imaging. The method illuminates a checkerboard phase grid to produce a fine grid-like intensity reference pattern at the detector, then spatially maps sample-induced distortions of this pattern to recover differential phase images of the sample. The use of a phase grid is an improvement on our previous absorption grid work in two ways. There is minimal loss in x-ray flux, permitting faster imaging, and, a very fine pattern is produced for homogenous high spatial resolution. We describe how this pattern permits retrieval of five images from a single exposure; the sample phase gradient images in the horizontal and vertical directions, a projected phase depth image, an edge-enhanced image, and a type of scattering image. Finally, we describe how the reconstruction technique can achieve subpixel distortion retrieval and study the behavior of the technique in regard to analysis technique, Talbot distance, and exposure time.


Assuntos
Iluminação/instrumentação , Microscopia de Contraste de Fase/instrumentação , Refratometria/instrumentação , Transdutores , Difração de Raios X/instrumentação , Desenho Assistido por Computador , Desenho de Equipamento , Análise de Falha de Equipamento
10.
Opt Express ; 20(10): 10724-49, 2012 May 07.
Artigo em Inglês | MEDLINE | ID: mdl-22565698

RESUMO

Differential X-ray phase-contrast tomography (DPCT) refers to a class of promising methods for reconstructing the X-ray refractive index distribution of materials that present weak X-ray absorption contrast. The tomographic projection data in DPCT, from which an estimate of the refractive index distribution is reconstructed, correspond to one-dimensional (1D) derivatives of the two-dimensional (2D) Radon transform of the refractive index distribution. There is an important need for the development of iterative image reconstruction methods for DPCT that can yield useful images from few-view projection data, thereby mitigating the long data-acquisition times and large radiation doses associated with use of analytic reconstruction methods. In this work, we analyze the numerical and statistical properties of two classes of discrete imaging models that form the basis for iterative image reconstruction in DPCT. We also investigate the use of one of the models with a modern image reconstruction algorithm for performing few-view image reconstruction of a tissue specimen.


Assuntos
Diagnóstico por Imagem/métodos , Microscopia de Contraste de Fase/métodos , Tomografia Computadorizada por Raios X/métodos , Algoritmos , Simulação por Computador , Processamento de Imagem Assistida por Computador/métodos , Interferometria/métodos , Modelos Estatísticos , Modelos Teóricos , Distribuição Normal , Imagens de Fantasmas , Radônio , Refratometria , Raios X
11.
Opt Express ; 19(25): 25545-58, 2011 Dec 05.
Artigo em Inglês | MEDLINE | ID: mdl-22273948

RESUMO

Phase retrieval from unidirectional radiographic differential phase contrast images requires integration of noisy data. A method is presented, which aims to suppress stripe artifacts arising from direct image integration. It is purely algorithmic and therefore, compared to alternative approaches, neither additional alignment nor an increased scan time is required. We report on the theory of this method and present results using numerical as well as experimental data. The method shows significant improvements on the phase retrieval accuracy and enhances contrast in the phase image. Due to its general applicability, the proposed method provides a valuable tool for various 2D imaging applications using differential data.


Assuntos
Algoritmos , Armazenamento e Recuperação da Informação/métodos , Intensificação de Imagem Radiográfica/métodos , Interpretação de Imagem Radiográfica Assistida por Computador/métodos , Difração de Raios X/métodos , Dinâmica não Linear
12.
Opt Express ; 19(25): 24890-6, 2011 Dec 05.
Artigo em Inglês | MEDLINE | ID: mdl-22273882

RESUMO

We report on a setup for differential x-ray phase-contrast imaging and tomography, that measures the full 2D phase-gradient information. The setup uses a simple one-dimensional x-ray grating interferometer, in which the grating structures of the interferometer are oriented at a tilt angle with respect to the sample rotation axis. In such a configuration, the differential phase images from opposing tomography projections can be combined to yield both components of the gradient vector. We show how the refractive index distribution as well as its x, y, and z gradient components can be reconstructed directly from the recorded projection data. The method can equally well be applied at conventional x-ray tube sources, to analyzer based x-ray imaging or neutron imaging. It is demonstrated with measurements of an x-ray phantom and a rat brain using synchrotron radiation.


Assuntos
Aumento da Imagem/instrumentação , Interferometria/instrumentação , Tomografia Computadorizada por Raios X/instrumentação , Desenho de Equipamento , Análise de Falha de Equipamento
13.
Opt Express ; 17(14): 11618-37, 2009 Jul 06.
Artigo em Inglês | MEDLINE | ID: mdl-19582078

RESUMO

Image magnification via twofold asymmetric Bragg reflection (a setup called the "Bragg Magnifier") is a recently established technique allowing to achieve both sub-micrometer spatial resolution and phase contrast in X-ray imaging. The present article extends a previously developed theoretical formalism to account for partially coherent illumination. At a typical synchrotron setup polychromatic illumination is identified as the main influence of partial coherence and the implications on imaging characteristics are analyzed by numerical simulations. We show that contrast decreases by about 50% when compared to the monochromatic case, while sub-micrometer spatial resolution is preserved. The theoretical formalism is experimentally verified by correctly describing the dispersive interaction of the two orthogonal magnifier crystals, an effect that has to be taken into account for precise data evaluation.


Assuntos
Processamento de Imagem Assistida por Computador/métodos , Óptica e Fotônica , Algoritmos , Simulação por Computador , Desenho de Equipamento , Análise de Fourier , Modelos Estatísticos , Modelos Teóricos , Síncrotrons , Raios X
14.
Phys Med Biol ; 64(20): 205008, 2019 10 10.
Artigo em Inglês | MEDLINE | ID: mdl-31509810

RESUMO

Iterative tomographic reconstruction has been established as a viable alternative for data analysis in phase-sensitive x-ray imaging based on the edge-illumination principle. However, previously published approaches did not account for drifts of optical elements during a scan, which can lead to artefacts. Up to now, the strategy to reduce these artefacts was to acquire additional intermediate flat field images, which were used to correct the sinograms. Here, we expand the theoretical model to take these effects into account and demonstrate a significant reduction of (ring)-artefacts in the final reconstructions, while allowing for a significant reduction of scan time and dose. We further improve the model by including the capability to reconstruct combined absorption and phase contrast slices, which we experimentally demonstrate to deliver improved contrast to noise ratios compared to previously employed single shot approaches.


Assuntos
Algoritmos , Processamento de Imagem Assistida por Computador/métodos , Modelos Teóricos , Tomografia Computadorizada por Raios X/instrumentação , Tomografia Computadorizada por Raios X/métodos , Artefatos , Simulação por Computador , Humanos , Iluminação , Raios X
15.
Opt Express ; 16(7): 5141-9, 2008 Mar 31.
Artigo em Inglês | MEDLINE | ID: mdl-18542614

RESUMO

An extension of the theoretical formalism of Fresnel diffraction to the case of an inclined image plane is proposed. The resulting numerical algorithm speeds up computation times by typically three orders of magnitude, thus opening the possibility of utilizing previously inapplicable image analysis algorithms for this special type of a non shift-invariant imaging system. This is exemplified by adapting an iterative phase retrieval algorithm developed for electron microscopy to the case of hard x-ray imaging with asymmetric Bragg reflection (the so-called "Bragg Magnifier"). Numerical simulations demonstrate the convergence and feasibility of the iterative phase retrieval algorithm for the case of x-ray imaging with the Bragg Magnifier.


Assuntos
Modelos Teóricos , Refratometria/métodos , Simulação por Computador , Luz , Espalhamento de Radiação
16.
Sci Rep ; 6: 30940, 2016 08 05.
Artigo em Inglês | MEDLINE | ID: mdl-27491917

RESUMO

Sensitivity to sub-pixel sample features has been demonstrated as a valuable capability of phase contrast x-ray imaging. Here, we report on a method to obtain angular-resolved small angle x-ray scattering distributions with edge-illumination- based imaging utilizing incoherent illumination from an x-ray tube. Our approach provides both the three established image modalities (absorption, differential phase and scatter strength), plus a number of additional contrasts related to unresolved sample features. The complementarity of these contrasts is experimentally validated by using different materials in powder form. As a significant application example we show that the extended complementary contrasts could allow the diagnosis of pulmonary emphysema in a murine model. In support of this, we demonstrate that the properties of the retrieved scattering distributions are consistent with the expectation of increased feature sizes related to pulmonary emphysema. Combined with the simplicity of implementation of edge-illumination, these findings suggest a high potential for exploiting extended sub-pixel contrasts in the diagnosis of lung diseases and beyond.


Assuntos
Processamento de Imagem Assistida por Computador/métodos , Enfisema Pulmonar/diagnóstico , Radiografia , Animais , Meios de Contraste , Humanos , Camundongos , Camundongos da Linhagem 129 , Espalhamento a Baixo Ângulo , Difração de Raios X , Raios X
17.
Sci Rep ; 5: 11980, 2015 Jul 13.
Artigo em Inglês | MEDLINE | ID: mdl-26165698

RESUMO

The goal of this study was to investigate the performance of 3D synchrotron differential phase contrast (DPC) imaging for the visualization of both macroscopic and microscopic aspects of atherosclerosis in the mouse vasculature ex vivo. The hearts and aortas of 2 atherosclerotic and 2 wild-type control mice were scanned with DPC imaging with an isotropic resolution of 15 µm. The coronary artery vessel walls were segmented in the DPC datasets to assess their thickness, and histological staining was performed at the level of atherosclerotic plaques. The DPC imaging allowed for the visualization of complex structures such as the coronary arteries and their branches, the thin fibrous cap of atherosclerotic plaques as well as the chordae tendineae. The coronary vessel wall thickness ranged from 37.4 ± 5.6 µm in proximal coronary arteries to 13.6 ± 3.3 µm in distal branches. No consistent differences in coronary vessel wall thickness were detected between the wild-type and atherosclerotic hearts in this proof-of-concept study, although the standard deviation in the atherosclerotic mice was higher in most segments, consistent with the observation of occasional focal vessel wall thickening. Overall, DPC imaging of the cardiovascular system of the mice allowed for a simultaneous detailed 3D morphological assessment of both large structures and microscopic details.


Assuntos
Aterosclerose/patologia , Animais , Apolipoproteínas E/deficiência , Apolipoproteínas E/genética , Aterosclerose/diagnóstico por imagem , Vasos Coronários/diagnóstico por imagem , Estudos de Viabilidade , Coração/diagnóstico por imagem , Imageamento Tridimensional , Camundongos , Camundongos Endogâmicos C57BL , Camundongos Knockout , Radiografia , Razão Sinal-Ruído , Síncrotrons
18.
Cardiovasc Res ; 105(2): 213-22, 2015 Feb 01.
Artigo em Inglês | MEDLINE | ID: mdl-25538157

RESUMO

AIMS: In this work, we provide novel insight into the morphology of dissecting abdominal aortic aneurysms in angiotensin II-infused mice. We demonstrate why they exhibit a large variation in shape and, unlike their human counterparts, are located suprarenally rather than infrarenally. METHODS AND RESULTS: We combined synchrotron-based, ultra-high resolution ex vivo imaging (phase contrast X-Ray tomographic microscopy) with in vivo imaging (high-frequency ultrasound and contrast-enhanced micro-CT) and image-guided histology. In all mice, we observed a tear in the tunica media of the abdominal aorta near the ostium of the celiac artery. Independently we found that, unlike the gradual luminal expansion typical for human aneurysms, the outer diameter increase of angiotensin II-induced dissecting aneurysms in mice was related to one or several intramural haematomas. These were caused by ruptures of the tunica media near the ostium of small suprarenal side branches, which had never been detected by the established small animal imaging techniques. The tear near the celiac artery led to apparent luminal dilatation, while the intramural haematoma led to a dissection of the tunica adventitia on the left suprarenal side of the aorta. The number of ruptured branches was higher in those aneurysms that extended into the thoracic aorta, which explained the observed variability in aneurysm shape. CONCLUSION: Our results are the first to describe apparent luminal dilatation, suprarenal branch ruptures, and intramural haematoma formation in dissecting abdominal aortic aneurysms in mice. Moreover, we validate and demonstrate the vast potential of phase contrast X-ray tomographic microscopy in cardiovascular small animal applications.


Assuntos
Aneurisma Roto/patologia , Angiotensina II/farmacologia , Aorta Torácica/patologia , Aneurisma da Aorta Abdominal/patologia , Dissecção Aórtica/patologia , Dilatação Patológica/tratamento farmacológico , Angiotensina II/administração & dosagem , Animais , Meios de Contraste , Modelos Animais de Doenças , Masculino , Camundongos Endogâmicos C57BL
19.
Sci Rep ; 5: 8514, 2015 Feb 17.
Artigo em Inglês | MEDLINE | ID: mdl-25686728

RESUMO

Faults in vascular (VN) and neuronal networks of spinal cord are responsible for serious neurodegenerative pathologies. Because of inadequate investigation tools, the lacking knowledge of the complete fine structure of VN and neuronal system represents a crucial problem. Conventional 2D imaging yields incomplete spatial coverage leading to possible data misinterpretation, whereas standard 3D computed tomography imaging achieves insufficient resolution and contrast. We show that X-ray high-resolution phase-contrast tomography allows the simultaneous visualization of three-dimensional VN and neuronal systems of ex-vivo mouse spinal cord at scales spanning from millimeters to hundreds of nanometers, with nor contrast agent nor sectioning and neither destructive sample-preparation. We image both the 3D distribution of micro-capillary network and the micrometric nerve fibers, axon-bundles and neuron soma. Our approach is very suitable for pre-clinical investigation of neurodegenerative pathologies and spinal-cord-injuries, in particular to resolve the entangled relationship between VN and neuronal system.


Assuntos
Imageamento Tridimensional/métodos , Microvasos , Vias Neurais , Medula Espinal/irrigação sanguínea , Medula Espinal/citologia , Animais , Camundongos , Tomografia Computadorizada por Raios X/métodos
20.
Tissue Eng Part C Methods ; 20(6): 451-63, 2014 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-24156382

RESUMO

BACKGROUND: Chronic venous insufficiency (CVI) represents a major global health problem with increasing prevalence and morbidity. CVI is due to an incompetence of the venous valves, which causes venous reflux and distal venous hypertension. Several studies have focused on the replacement of diseased venous valves using xeno- and allogenic transplants, so far with moderate success due to immunologic and thromboembolic complications. Autologous cell-derived tissue-engineered venous valves (TEVVs) based on fully biodegradable scaffolds could overcome these limitations by providing non-immunogenic, non-thrombogenic constructs with remodeling and growth potential. METHODS: Tri- and bicuspid venous valves (n=27) based on polyglycolic acid-poly-4-hydroxybutyrate composite scaffolds, integrated into self-expandable nitinol stents, were engineered from autologous ovine bone-marrow-derived mesenchymal stem cells (BM-MSCs) and endothelialized. After in vitro conditioning in a (flow) pulse duplicator system, the TEVVs were crimped (n=18) and experimentally delivered (n=7). The effects of crimping on the tissue-engineered constructs were investigated using histology, immunohistochemistry, scanning electron microscopy, grating interferometry (GI), and planar fluorescence reflectance imaging. RESULTS: The generated TEVVs showed layered tissue formation with increasing collagen and glycosaminoglycan levels dependent on the duration of in vitro conditioning. After crimping no effects were found on the MSC level in scanning electron microscopy analysis, GI, histology, and extracellular matrix analysis. However, substantial endothelial cell loss was detected after the crimping procedure, which could be reduced by increasing the static conditioning phase. CONCLUSIONS: Autologous living small-diameter TEVVs can be successfully fabricated from ovine BM-MSCs using a (flow) pulse duplicator conditioning approach. These constructs hold the potential to overcome the limitations of currently used non-autologous replacement materials and may open new therapeutic concepts for the treatment of CVI in the future.


Assuntos
Bioprótese , Cateterismo Periférico/instrumentação , Transplante de Células-Tronco Mesenquimais/instrumentação , Células-Tronco Mesenquimais/citologia , Alicerces Teciduais , Válvulas Venosas/crescimento & desenvolvimento , Animais , Cateterismo Periférico/métodos , Células Cultivadas , Células Endoteliais , Análise de Falha de Equipamento , Estudos de Viabilidade , Transplante de Células-Tronco Mesenquimais/métodos , Células-Tronco Mesenquimais/fisiologia , Desenho de Prótese , Ovinos , Engenharia Tecidual/instrumentação , Resultado do Tratamento , Dispositivos de Acesso Vascular , Válvulas Venosas/citologia , Válvulas Venosas/cirurgia
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA