Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 4 de 4
Filtrar
1.
Vox Sang ; 105(2): 137-43, 2013 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-23448618

RESUMO

BACKGROUND: Although orthotopic liver transplantation (OLT) is nowadays considered standard practice at experienced centres, it can still be affected by a significant risk of massive bleeding and its related complications. Solvent/detergent plasma (S/D Plasma) has been proposed as an alternative to fresh frozen plasma (FFP) to curtail such complications. This study aimed at evaluating the efficacy of S/D Plasma in OLT patients by comparing it to FFP. MATERIALS AND METHODS: Sixty-three OLT patients were randomized into two groups depending on whether they were transfused with FFP or S/D plasma. A thromboelastography-based protocol aimed at achieving and maintaining predetermined coagulation goals was used to guide plasma transfusions. At the beginning and the end of surgery, standard laboratory coagulation tests were performed together with the assessment of the VII, VIII, V, XII factors and S protein blood levels. RESULTS: The two study groups equally achieved the thromboelastography goals but with a reduced amount of transfusions in the S/D plasma group (P < 0.0001). At the end of surgery, factors V and XII and S protein blood levels were lower in the S/D plasma patients who also showed lower INR, aPTT and antithrombin III levels. CONCLUSION: In cirrhotic patients undergoing OLT, the use of S\D plasma associated with thromboelastography allows the same clinical results but with a significant reduction in the amount of plasma transfusions.


Assuntos
Transfusão de Componentes Sanguíneos , Detergentes/administração & dosagem , Cirrose Hepática/cirurgia , Transplante de Fígado , Plasma , Solventes/administração & dosagem , Adulto , Aloenxertos , Proteínas Sanguíneas/metabolismo , Feminino , Humanos , Cirrose Hepática/sangue , Masculino , Pessoa de Meia-Idade , Tromboelastografia/métodos
2.
Br J Anaesth ; 102(1): 47-54, 2009 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-19059920

RESUMO

BACKGROUND: The pulmonary artery catheter is invasive and may cause serious complications. A safe method of cardiac output (CO) measurement is needed. We have assessed the accuracy and reliability of a recently marketed self-calibrating arterial pulse contour CO monitoring system (FloTrac/Vigileo) in end-stage liver failure patients undergoing liver transplant. The pattern of alterations known as cirrhotic cardiomyopathy, and the transplant procedure itself, provided an evaluation under varying clinical conditions. METHODS: The cardiac index was measured simultaneously by thermodilution (CI(TD): mean of four readings) using a pulmonary artery catheter and pulse contour analysis (CI(V): mean value computed by the FloTrac/Vigileo over the same time period). Readings were made at 10 time-points during liver transplant surgery (T1-T5) and on the intensive care unit (T6-T10). CI(V) was computed using the latest Vigileo software version 01.10. RESULTS: A total of 290 paired readings from 29 patients were collected. Mean (SD) CI(TD) was 5.2 (1.3) and CI(V) was 3.9 (0.9) litre min(-1) m(-2), with a corrected for repeated measures bias between readings of 1.3 (0.2) litre min(-1) m(-2) and 95% limits of agreement of -1.5 (0.2) to 4.1 (0.3) litre min(-1) m(-2). The percentage error (2SD(Bias)/meanCI(TD)) was 54%, which exceeded a 30% limit of acceptance. Low peripheral resistance and increasing bias were related (r=0.69; P<0.001). The Vigileo system failed to reliably trend CI data, with a concordance compared with thermodilution below an acceptable level (at best 68% of sequential readings). CONCLUSIONS: In cirrhotic patients with hyperdynamic circulation, the Vigileo system showed a degree of error and unreliability higher than that considered acceptable for clinical purposes.


Assuntos
Débito Cardíaco , Cirrose Hepática/cirurgia , Transplante de Fígado , Monitorização Intraoperatória/métodos , Adulto , Pressão Sanguínea , Cateterismo Cardíaco , Cuidados Críticos/métodos , Feminino , Humanos , Cirrose Hepática/fisiopatologia , Falência Hepática Aguda/fisiopatologia , Falência Hepática Aguda/cirurgia , Masculino , Pessoa de Meia-Idade , Monitorização Intraoperatória/instrumentação , Monitorização Fisiológica/métodos , Cuidados Pós-Operatórios/métodos , Artéria Pulmonar/fisiopatologia , Pulso Arterial , Reprodutibilidade dos Testes , Termodiluição/métodos , Resistência Vascular , Adulto Jovem
3.
J Clin Monit Comput ; 22(6): 449-52, 2008 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-19112602

RESUMO

Acute hepatic failure (ALF) is an uncommon disease characterized by a rapid deterioration of the hepatic function with severe derangements of the mental status in previously healthy subjects due to massive hepatocytes necrosis. Neurological impairment, due to intracranial hypertension and cerebral ischemia, is a key factor because it is a main criterion to decide when to proceed to liver transplantation, which is only treatment for these patients. Therefore, neurological monitoring holds an essential role in the clinical management of ALF patients but it needs to be performed at the point-of-care in the majority of the cases as such critically ill patients cannot be moved away from the ICU because they frequently need continuous hemodynamic, ventilatory and renal support. We herein report and discuss our experience relating to the use of transcranial sonography as a neuro-monitoring tool in ALF patients. In our series this technique allowed a repeatable and reliable non-invasive assessment of cerebral blood flow changes at the bedside thus avoiding the complications associated with the use of an intracranial probe to measure intra-cranial pressure and making it possible to correctly evaluate the timing and feasibility of liver transplantation.


Assuntos
Isquemia Encefálica/diagnóstico por imagem , Isquemia Encefálica/etiologia , Técnicas de Apoio para a Decisão , Interpretação de Imagem Assistida por Computador/métodos , Falência Hepática Aguda/complicações , Falência Hepática Aguda/diagnóstico por imagem , Sistemas Automatizados de Assistência Junto ao Leito , Ultrassonografia Doppler Transcraniana/métodos , Sistemas de Apoio a Decisões Clínicas , Feminino , Humanos , Masculino , Prognóstico , Reprodutibilidade dos Testes , Sensibilidade e Especificidade
4.
Minerva Anestesiol ; 75(10): 555-62, 2009 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-19461563

RESUMO

AIM: The aim of this study was to investigate the hypothesis that periodical sampling of the tracheo-bronchial tree in the absence of clinical suspicion of pneumonia is useful to identify bacteria responsible for subsequent late ventilator associated pneumonia (VAP). This was a retrospective observational human study carried out in two medical-surgical intensive care units of two different hospitals. From January 1999 to December 2000, 559 patients, who received invasive respiratory support for more than 48 hours, were screened. METHODS: Tracheal aspiration (TA) was performed once or twice weekly in all mechanically ventilated patients. The microbiological findings from TA surveillance cultures done in the eight days before suspicion of VAP were compared to those isolated from the positive diagnostic samples done for late onset VAP (after more than four days of mechanical ventilation). The sensitivity, specificity, and positive/negative predictive values of the ability of the surveillance sample to anticipate the VAP pathogen were calculated. RESULTS: Among the microorganisms isolated from TA, 68% were retrieved from diagnostic samples. All VAP pathogens previously isolated were from 43% of the TA samples. If TA was collected 2-4 days before the clinical diagnosis of VAP, pathogens were detected in 58% of samples. In contrast, only 27% were collected more than four days earlier (P<0.05). The positive predictive values for Pseudomonas aeruginosa and methicillin resistant Staphylococcus aureus from routine TA samples were 92% and 90%, respectively. The negative predictive values for Pseudomonas aeruginosa and methicillin resistant Staphylococcus aureus from routine TA samples were 75% and 89%, respectively. CONCLUSIONS: TA cultures in ventilated patients may help to predict pathogens. Early detection may lead to earlier treatment in long term ventilated patients when VAP is suspected.


Assuntos
Bactérias/isolamento & purificação , Pneumonia Associada à Ventilação Mecânica/microbiologia , Traqueia/microbiologia , Humanos , Vigilância da População , Valor Preditivo dos Testes , Estudos Retrospectivos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA