Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 135
Filtrar
1.
Circulation ; 149(9): 644-655, 2024 02 27.
Artigo em Inglês | MEDLINE | ID: mdl-37883682

RESUMO

BACKGROUND: The optimal treatment in patients with severe aortic stenosis and small aortic annulus (SAA) remains to be determined. This study aimed to compare the hemodynamic and clinical outcomes between transcatheter aortic valve replacement (TAVR) and surgical aortic valve replacement (SAVR) in patients with a SAA. METHODS: This prospective multicenter international randomized trial was performed in 15 university hospitals. Participants were 151 patients with severe aortic stenosis and SAA (mean diameter <23 mm) randomized (1:1) to TAVR (n=77) versus SAVR (n=74). The primary outcome was impaired valve hemodynamics (ie, severe prosthesis patient mismatch or moderate-severe aortic regurgitation) at 60 days as evaluated by Doppler echocardiography and analyzed in a central echocardiography core laboratory. Clinical events were secondary outcomes. RESULTS: The mean age of the participants was 75.5±5.1 years, with 140 (93%) women, a median Society of Thoracic Surgeons predicted risk of mortality of 2.50% (interquartile range, 1.67%-3.28%), and a median annulus diameter of 21.1 mm (interquartile range, 20.4-22.0 mm). There were no differences between groups in the rate of severe prosthesis patient mismatch (TAVR, 4 [5.6%]; SAVR, 7 [10.3%]; P=0.30) and moderate-severe aortic regurgitation (none in both groups). No differences were found between groups in mortality rate (TAVR, 1 [1.3%]; SAVR, 1 [1.4%]; P=1.00) and stroke (TAVR, 0; SAVR, 2 [2.7%]; P=0.24) at 30 days. After a median follow-up of 2 (interquartile range, 1-4) years, there were no differences between groups in mortality rate (TAVR, 7 [9.1%]; SAVR, 6 [8.1%]; P=0.89), stroke (TAVR, 3 [3.9%]; SAVR, 3 [4.1%]; P=0.95), and cardiac hospitalization (TAVR, 15 [19.5%]; SAVR, 15 [20.3%]; P=0.80). CONCLUSIONS: In patients with severe aortic stenosis and SAA (women in the majority), there was no evidence of superiority of contemporary TAVR versus SAVR in valve hemodynamic results. After a median follow-up of 2 years, there were no differences in clinical outcomes between groups. These findings suggest that the 2 therapies represent a valid alternative for treating patients with severe aortic stenosis and SAA, and treatment selection should likely be individualized according to baseline characteristics, additional anatomical risk factors, and patient preference. However, the results of this study should be interpreted with caution because of the limited sample size leading to an underpowered study, and need to be confirmed in future larger studies. REGISTRATION: URL: https://www.clinicaltrials.gov; Unique identifier: NCT03383445.


Assuntos
Insuficiência da Valva Aórtica , Estenose da Valva Aórtica , Implante de Prótese de Valva Cardíaca , Próteses Valvulares Cardíacas , Acidente Vascular Cerebral , Substituição da Valva Aórtica Transcateter , Humanos , Feminino , Idoso , Idoso de 80 Anos ou mais , Masculino , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/cirurgia , Insuficiência da Valva Aórtica/diagnóstico por imagem , Insuficiência da Valva Aórtica/cirurgia , Insuficiência da Valva Aórtica/etiologia , Estudos Prospectivos , Estenose da Valva Aórtica/diagnóstico por imagem , Estenose da Valva Aórtica/cirurgia , Resultado do Tratamento , Substituição da Valva Aórtica Transcateter/efeitos adversos , Fatores de Risco , Acidente Vascular Cerebral/etiologia
2.
Omega (Westport) ; : 302228221125968, 2022 Sep 07.
Artigo em Inglês | MEDLINE | ID: mdl-36069760

RESUMO

This study seeks to know if there is a relationship between measures of suicidal ideation and cognitive orientation towards spirituality, religious attitudes and beliefs, and religious practice. A non-experimental, descriptive, and correlational design, cross-sectional and quantitative approach was used. The sample was made up of 1372 adolescents, 59.2% female, 40.8% male, mean age 14.57, s = 1.75, range 12-17 years old, students from public schools in two cities in Colombia. The results indicated an inverse relationship between negative suicidal ideation (NSI) and cognitive orientation towards spirituality, beliefs and attitudes, and religious practice, and a positive relationship between them and positive suicidal ideation. The regression analysis showed the contribution of spirituality, religious beliefs, and attitudes in the prediction of NSI. In conclusion, the dimensions of spirituality and religiosity can help reduce suicidal thinking, acting as protective factors. The cultivation of a spiritual and/or religious life can be suitable and complementary ways as measures of prevention of suicidal behaviour.

3.
Clin Infect Dis ; 73(11): e3750-e3758, 2021 12 06.
Artigo em Inglês | MEDLINE | ID: mdl-33733675

RESUMO

BACKGROUND: Procedural improvements combined with the contemporary clinical profile of patients undergoing transcatheter aortic valve replacement (TAVR) may have influenced the incidence and outcomes of infective endocarditis (IE) following TAVR. We aimed to determine the temporal trends, characteristics, and outcomes of IE post-TAVR. METHODS: Observational study including 552 patients presenting definite IE post-TAVR. Patients were divided in 2 groups according to the timing of TAVR (historical cohort [HC]: before 2014; contemporary cohort [CC]: after 2014). RESULTS: Overall incidence rates of IE were similar in both cohorts (CC vs HC: 5.45 vs 6.52 per 1000 person-years; P = .12), but the rate of early IE was lower in the CC (2.29‰ vs 4.89‰, P < .001). Enterococci were the most frequent microorganism. Most patients presented complicated IE ( CC: 67.7%; HC: 69.6%; P = .66), but the rate of surgical treatment remained low (CC: 20.7%; HC: 17.3%; P = .32). The CC exhibited lower rates of in-hospital acute kidney injury (35.1% vs 44.6%; P = .036) and in-hospital (26.6% vs 36.4%; P = .016) and 1-year (37.8% vs 53.5%; P < .001) mortality. Higher logistic EuroScore, Staphylococcus aureus etiology, and complications (stroke, heart failure, and acute renal failure) were associated with in-hospital mortality in multivariable analyses (P < .05 for all). CONCLUSIONS: Although overall IE incidence has remained stable, the incidence of early IE has declined in recent years. The microorganism, high rate of complications, and very low rate of surgical treatment remained similar. In-hospital and 1-year mortality rates were high but progressively decreased over time.


Assuntos
Endocardite Bacteriana , Endocardite , Substituição da Valva Aórtica Transcateter , Endocardite/epidemiologia , Endocardite/etiologia , Endocardite/cirurgia , Endocardite Bacteriana/epidemiologia , Endocardite Bacteriana/etiologia , Endocardite Bacteriana/cirurgia , Humanos , Incidência , Complicações Pós-Operatórias/epidemiologia , Fatores de Risco , Substituição da Valva Aórtica Transcateter/efeitos adversos , Resultado do Tratamento
4.
Europace ; 23(2): 254-263, 2021 02 05.
Artigo em Inglês | MEDLINE | ID: mdl-33083813

RESUMO

AIMS: We determined the incidence and type of arrhythmias at 2-year follow-up in patients with new-onset persistent left bundle branch block (LBBB) following transcatheter aortic valve replacement (TAVR). METHODS AND RESULTS: Multicentre prospective study including 103 consecutive patients with new-onset persistent LBBB post-TAVR (SAPIEN XT/3: 53; CoreValve/Evolut R: 50). An implantable cardiac monitor (Reveal XT, Reveal Linq) was implanted before hospital discharge and patients had continuous monitoring for up to 2 years. Arrhythmic events were adjudicated in a central core lab. 1836 new arrhythmic events (tachyarrhythmias: 1655 and bradyarrhythmias: 181) occurred at 2 years. Of these, 283 (15%) occurred beyond 1 year (tachyarrhythmias 212, bradyarrhythmias 71) in 33 (36%) patients, without differences between valve type. Most late (>1 year) arrhythmic events were asymptomatic (94%) and led to a treatment change in 17 (19%) patients. A total of 71 late bradyarrhythmias [high-degree atrioventricular block (HAVB): 3, severe bradycardia: 68] were detected in 17 (21%) patients. At 2 years, 18 (17%) patients had received a permanent pacemaker (PPM) or implantable cardiac-defibrillator. PPM implantation due to HAVB predominated in the early phase post-TAVR, with only 1 HAVB event requiring PPM implantation after 1 year. CONCLUSION: Patients with new-onset LBBB post-TAVR exhibited a very high burden of arrhythmic events within the 2 years post-procedure. While new tachyarrhythmic events were homogeneously distributed over time, the vast majority of new HAVB episodes leading to PPM implantation occurred early after the procedure. These results should help to guide the management of this challenging group of patients. (clinicaltrials.gov: NCT02153307).


Assuntos
Estenose da Valva Aórtica , Marca-Passo Artificial , Substituição da Valva Aórtica Transcateter , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/cirurgia , Estenose da Valva Aórtica/cirurgia , Bloqueio de Ramo/diagnóstico , Bloqueio de Ramo/epidemiologia , Bloqueio de Ramo/etiologia , Humanos , Estudos Prospectivos , Fatores de Risco , Substituição da Valva Aórtica Transcateter/efeitos adversos , Resultado do Tratamento
5.
Eur Heart J ; 41(29): 2731-2742, 2020 08 01.
Artigo em Inglês | MEDLINE | ID: mdl-32592401

RESUMO

AIMS: Due to bioprosthetic valve degeneration, aortic valve-in-valve (ViV) procedures are increasingly performed. There are no data on long-term outcomes after aortic ViV. Our aim was to perform a large-scale assessment of long-term survival and reintervention after aortic ViV. METHODS AND RESULTS: A total of 1006 aortic ViV procedures performed more than 5 years ago [mean age 77.7 ± 9.7 years; 58.8% male; median STS-PROM score 7.3% (4.2-12.0)] were included in the analysis. Patients were treated with Medtronic self-expandable valves (CoreValve/Evolut, Medtronic Inc., Minneapolis, MN, USA) (n = 523, 52.0%), Edwards balloon-expandable valves (EBEV, SAPIEN/SAPIEN XT/SAPIEN 3, Edwards Lifesciences, Irvine, CA, USA) (n = 435, 43.2%), and other devices (n = 48, 4.8%). Survival was lower at 8 years in patients with small-failed bioprostheses [internal diameter (ID) ≤ 20 mm] compared with those with large-failed bioprostheses (ID > 20 mm) (33.2% vs. 40.5%, P = 0.01). Independent correlates for mortality included smaller-failed bioprosthetic valves [hazard ratio (HR) 1.07 (95% confidence interval (CI) 1.02-1.13)], age [HR 1.21 (95% CI 1.01-1.45)], and non-transfemoral access [HR 1.43 (95% CI 1.11-1.84)]. There were 40 reinterventions after ViV. Independent correlates for all-cause reintervention included pre-existing severe prosthesis-patient mismatch [subhazard ratio (SHR) 4.34 (95% CI 1.31-14.39)], device malposition [SHR 3.75 (95% CI 1.36-10.35)], EBEV [SHR 3.34 (95% CI 1.26-8.85)], and age [SHR 0.59 (95% CI 0.44-0.78)]. CONCLUSIONS: The size of the original failed valve may influence long-term mortality, and the type of the transcatheter valve may influence the need for reintervention after aortic ViV.


Assuntos
Estenose da Valva Aórtica , Bioprótese , Implante de Prótese de Valva Cardíaca , Próteses Valvulares Cardíacas , Substituição da Valva Aórtica Transcateter , Idoso , Idoso de 80 Anos ou mais , Valva Aórtica/cirurgia , Estenose da Valva Aórtica/cirurgia , Feminino , Humanos , Masculino , Desenho de Prótese , Falha de Prótese , Resultado do Tratamento
6.
Eur Heart J ; 40(5): 456-465, 2019 02 01.
Artigo em Inglês | MEDLINE | ID: mdl-30590565

RESUMO

Aims: The aim of this study was to compare clinical outcomes of patients undergoing transfemoral transcatheter aortic valve implantation (TAVI) with balloon-expandable (BE) valves vs. self-expandable (SE) valves. Transcatheter aortic valve implantation is a minimally invasive and lifesaving treatment in patients with aortic valve stenosis. Even though BE-valves and SE-valves are both commonly used on a large scale, adequately sized trials comparing clinical outcomes in patients with severe aortic valve stenosis treated with BE-valves compared with SE-valves are lacking. Methods and results: In this CENTER-collaboration, data from 10 registries or clinical trials, selected through a systematic search, were pooled and analysed. Propensity score methodology was used to reduce treatment selection bias and potential confounding. The primary endpoints were mortality and stroke at 30 days follow-up in patients treated with BE-valves compared with SE-valves. Secondary endpoints included clinical outcomes, e.g. bleeding during hospital admission. All outcomes were split for early-generation BE-valves compared with early-generation SE-valves and new-generation BE-valves with new-generation SE-valves. The overall patient population (N = 12 381) included 6239 patients undergoing TAVI with BE-valves and 6142 patients with SE-valves. The propensity matched population had a mean age of 81 ± 7 years and a median STS-PROM score or 6.5% [interquartile range (IQR) 4.0-13.0%]. At 30-day follow-up, the mortality rate was not statistically different in patients undergoing TAVI with BE-valves compared with SE-valves [BE: 5.3% vs. SE: 6.2%, relative risk (RR) 0.9; 95% confidence interval (CI) 0.7-1.0, P = 0.10]. Stroke occurred less frequently in patients treated with BE-valves (BE: 1.9% vs. SE: 2.6%, RR 0.7; 95% CI 0.5-1.0, P = 0.03). Also, patients treated with BE-valves had a three-fold lower risk of requiring pacemaker implantation (BE: 7.8% vs. SE: 20.3%, RR 0.4; 95% CI 0.3-0.4, P < 0.001). In contrast, patients treated with new-generation BE-valves more frequently experienced major and life-threatening bleedings compared with new-generation SE-valves (BE: 4.8% vs. SE: 2.1%, RR 2.3; 95% CI 1.6-3.3, P < 0.001). Conclusion: In this study, which is the largest study to compare valve types in TAVI, we demonstrated that the incidence of stroke and pacemaker implantation was lower in patients undergoing transfemoral TAVI with BE-valves compared with SE-valves. In contrast, patients treated with new-generation BE-valves more often suffered from major or life-threatening bleedings than patients with new-generation SE-valves. Mortality at 30-days was not statistically different in patients treated with BE-valves compared with SE-valves. This study was a propensity-matched analysis generated from observational data, accordingly current outcomes will have to be confirmed in a large scale randomized controlled trial.


Assuntos
Estenose da Valva Aórtica/cirurgia , Próteses Valvulares Cardíacas , Marca-Passo Artificial/estatística & dados numéricos , Desenho de Prótese , Acidente Vascular Cerebral/epidemiologia , Substituição da Valva Aórtica Transcateter , Idoso , Idoso de 80 Anos ou mais , Valva Aórtica/cirurgia , Conversão para Cirurgia Aberta/estatística & dados numéricos , Feminino , Implante de Prótese de Valva Cardíaca/efeitos adversos , Humanos , Masculino , Estudos Observacionais como Assunto , Complicações Pós-Operatórias/epidemiologia , Complicações Pós-Operatórias/mortalidade , Pontuação de Propensão , Sistema de Registros , Acidente Vascular Cerebral/etiologia , Substituição da Valva Aórtica Transcateter/métodos , Substituição da Valva Aórtica Transcateter/mortalidade
7.
Circulation ; 131(18): 1566-74, 2015 May 05.
Artigo em Inglês | MEDLINE | ID: mdl-25753535

RESUMO

BACKGROUND: We aimed to determine the incidence, predictors, clinical characteristics, management, and outcomes of infective endocarditis (IE) after transcatheter aortic valve implantation (TAVI). METHODS AND RESULTS: This multicenter registry included 53 patients (mean age, 79±8 years; men, 57%) who suffered IE after TAVI of 7944 patients after a mean follow-up of 1.1±1.2 years (incidence, 0.67%, 0.50% within the first year after TAVI). Mean time from TAVI was 6 months (interquartile range, 1-14 months). Orotracheal intubation (hazard ratio, 3.87; 95% confidence interval, 1.55-9.64; P=0.004) and the self-expandable CoreValve system (hazard ratio, 3.12; 95% confidence interval, 1.37-7.14; P=0.007) were associated with IE (multivariate analysis including 3067 patients with individual data). The most frequent causal microorganisms were coagulase-negative staphylococci (24%), followed by Staphylococcus aureus (21%) and enterococci (21%). Vegetations were present in 77% of patients (transcatheter valve leaflets, 39%; stent frame, 17%; mitral valve, 21%). At least 1 complication of IE occurred in 87% of patients (heart failure in 68%). However, only 11% of patients underwent valve intervention (valve explantation and valve-in-valve procedure in 4 and 2 patients, respectively). The mortality rate in hospital was 47.2% and increased to 66% at the 1-year follow-up. IE complications such as heart failure (P=0.037) and septic shock (P=0.002) were associated with increased in-hospital mortality. CONCLUSIONS: The incidence of IE at 1 year after TAVI was 0.50%, and the risk increased with the use of orotracheal intubation and a self-expandable valve system. Staphylococci and enterococci were the most common agents. Although most patients presented at least 1 complication of IE, valve intervention was performed in a minority of patients, and nearly half of the patients died during the hospitalization period.


Assuntos
Endocardite Bacteriana/etiologia , Próteses Valvulares Cardíacas/efeitos adversos , Complicações Pós-Operatórias/etiologia , Infecções Relacionadas à Prótese/etiologia , Substituição da Valva Aórtica Transcateter , Idoso , Idoso de 80 Anos ou mais , Estenose da Valva Aórtica/cirurgia , Endocardite Bacteriana/mortalidade , Endocardite Bacteriana/cirurgia , Enterococcus , Contaminação de Equipamentos , Feminino , Infecções por Bactérias Gram-Positivas/etiologia , Infecções por Bactérias Gram-Positivas/cirurgia , Insuficiência Cardíaca/etiologia , Mortalidade Hospitalar , Humanos , Incidência , Intubação Intratraqueal/efeitos adversos , Estimativa de Kaplan-Meier , Masculino , Complicações Pós-Operatórias/mortalidade , Complicações Pós-Operatórias/cirurgia , Modelos de Riscos Proporcionais , Infecções Relacionadas à Prótese/mortalidade , Infecções Relacionadas à Prótese/cirurgia , Sistema de Registros , Estudos Retrospectivos , Risco , Infecções Estafilocócicas/etiologia , Infecções Estafilocócicas/cirurgia , Resultado do Tratamento
8.
Circulation ; 142(15): 1497-1499, 2020 10 13.
Artigo em Inglês | MEDLINE | ID: mdl-33044863
9.
JAMA ; 316(10): 1083-92, 2016 Sep 13.
Artigo em Inglês | MEDLINE | ID: mdl-27623462

RESUMO

IMPORTANCE: Limited data exist on clinical characteristics and outcomes of patients who had infective endocarditis after undergoing transcatheter aortic valve replacement (TAVR). OBJECTIVE: To determine the associated factors, clinical characteristics, and outcomes of patients who had infective endocarditis after TAVR. DESIGN, SETTING, AND PARTICIPANTS: The Infectious Endocarditis after TAVR International Registry included patients with definite infective endocarditis after TAVR from 47 centers from Europe, North America, and South America between June 2005 and October 2015. EXPOSURE: Transcatheter aortic valve replacement for incidence of infective endocarditis and infective endocarditis for in-hospital mortality. MAIN OUTCOMES AND MEASURES: Infective endocarditis and in-hospital mortality after infective endocarditis. RESULTS: A total of 250 cases of infective endocarditis occurred in 20 006 patients after TAVR (incidence, 1.1% per person-year; 95% CI, 1.1%-1.4%; median age, 80 years; 64% men). Median time from TAVR to infective endocarditis was 5.3 months (interquartile range [IQR], 1.5-13.4 months). The characteristics associated with higher risk of progressing to infective endocarditis after TAVR was younger age (78.9 years vs 81.8 years; hazard ratio [HR], 0.97 per year; 95% CI, 0.94-0.99), male sex (62.0% vs 49.7%; HR, 1.69; 95% CI, 1.13-2.52), diabetes mellitus (41.7% vs 30.0%; HR, 1.52; 95% CI, 1.02-2.29), and moderate to severe aortic regurgitation (22.4% vs 14.7%; HR, 2.05; 95% CI, 1.28-3.28). Health care-associated infective endocarditis was present in 52.8% (95% CI, 46.6%-59.0%) of patients. Enterococci species and Staphylococcus aureus were the most frequently isolated microorganisms (24.6%; 95% CI, 19.1%-30.1% and 23.3%; 95% CI, 17.9%-28.7%, respectively). The in-hospital mortality rate was 36% (95% CI, 30.0%-41.9%; 90 deaths; 160 survivors), and surgery was performed in 14.8% (95% CI, 10.4%-19.2%) of patients during the infective endocarditis episode. In-hospital mortality was associated with a higher logistic EuroSCORE (23.1% vs 18.6%; odds ratio [OR], 1.03 per 1% increase; 95% CI, 1.00-1.05), heart failure (59.3% vs 23.7%; OR, 3.36; 95% CI, 1.74-6.45), and acute kidney injury (67.4% vs 31.6%; OR, 2.70; 95% CI, 1.42-5.11). The 2-year mortality rate was 66.7% (95% CI, 59.0%-74.2%; 132 deaths; 115 survivors). CONCLUSIONS AND RELEVANCE: Among patients undergoing TAVR, younger age, male sex, history of diabetes mellitus, and moderate to severe residual aortic regurgitation were significantly associated with an increased risk of infective endocarditis. Patients who developed endocarditis had high rates of in-hospital mortality and 2-year mortality.


Assuntos
Endocardite Bacteriana/epidemiologia , Endocardite/etiologia , Mortalidade Hospitalar/tendências , Substituição da Valva Aórtica Transcateter/efeitos adversos , Fatores Etários , Idoso , Endocardite Bacteriana/etiologia , Feminino , Seguimentos , Insuficiência Cardíaca , Humanos , Masculino , Razão de Chances , Sistema de Registros , Fatores de Risco , Fatores Sexuais , Infecções Estafilocócicas/epidemiologia , Infecções Estafilocócicas/etiologia , Staphylococcus aureus , Resultado do Tratamento
10.
Circulation ; 129(11): 1233-43, 2014 Mar 18.
Artigo em Inglês | MEDLINE | ID: mdl-24370552

RESUMO

BACKGROUND: Very few data exist on the clinical impact of permanent pacemaker implantation (PPI) after transcatheter aortic valve implantation. The objective of this study was to assess the impact of PPI after transcatheter aortic valve implantation on late outcomes in a large cohort of patients. METHODS AND RESULTS: A total of 1556 consecutive patients without prior PPI undergoing transcatheter aortic valve implantation were included. Of them, 239 patients (15.4%) required a PPI within the first 30 days after transcatheter aortic valve implantation. At a mean follow-up of 22±17 months, no association was observed between the need for 30-day PPI and all-cause mortality (hazard ratio, 0.98; 95% confidence interval, 0.74-1.30; P=0.871), cardiovascular mortality (hazard ratio, 0.81; 95% confidence interval, 0.56-1.17; P=0.270), and all-cause mortality or rehospitalization for heart failure (hazard ratio, 1.00; 95% confidence interval, 0.77-1.30; P=0.980). A lower rate of unexpected (sudden or unknown) death was observed in patients with PPI (hazard ratio, 0.31; 95% confidence interval, 0.11-0.85; P=0.023). Patients with new PPI showed a poorer evolution of left ventricular ejection fraction over time (P=0.017), and new PPI was an independent predictor of left ventricular ejection fraction decrease at the 6- to 12-month follow-up (estimated coefficient, -2.26; 95% confidence interval, -4.07 to -0.44; P=0.013; R(2)=0.121). CONCLUSIONS: The need for PPI was a frequent complication of transcatheter aortic valve implantation, but it was not associated with any increase in overall or cardiovascular death or rehospitalization for heart failure after a mean follow-up of ≈2 years. Indeed, 30-day PPI was a protective factor for the occurrence of unexpected (sudden or unknown) death. However, new PPI did have a negative effect on left ventricular function over time.


Assuntos
Valva Aórtica/cirurgia , Cateterismo Cardíaco/tendências , Implante de Prótese de Valva Cardíaca/tendências , Marca-Passo Artificial/tendências , Função Ventricular Esquerda/fisiologia , Idoso , Idoso de 80 Anos ou mais , Valva Aórtica/patologia , Cateterismo Cardíaco/mortalidade , Estudos de Coortes , Feminino , Seguimentos , Implante de Prótese de Valva Cardíaca/mortalidade , Humanos , Masculino , Estudos Prospectivos , Estudos Retrospectivos , Fatores de Tempo , Resultado do Tratamento
11.
Eur Heart J ; 35(38): 2685-96, 2014 Oct 07.
Artigo em Inglês | MEDLINE | ID: mdl-24796337

RESUMO

AIM: The aim of this study was to determine the effects of advanced chronic kidney disease (CKD) on early and late outcomes after transcatheter aortic valve implantation (TAVI), and to evaluate the predictive factors of poorer outcomes in such patients. METHODS AND RESULTS: This was a multicentre study including a total of 2075 consecutive patients who had undergone TAVI. Patients were grouped according the estimated glomerular filtration rate as follows: CKD stage 1-2 (≥60 mL/min/1.73 m(2); n = 950), stage 3 (30-59 mL/min/1.73 m(2); n = 924), stage 4 (15-29 mL/min/1.73 m(2); n = 134) and stage 5 (<15 mL/min/1.73 m² or dialysis; n = 67). Clinical outcomes were evaluated at 30-days and at follow-up (median of 15 [6-29] months) and defined according to the VARC criteria. Advanced CKD (stage 4-5) was an independent predictor of 30-day major/life-threatening bleeding (P = 0.001) and mortality (P = 0.027), and late overall, cardiovascular and non-cardiovascular mortality (P < 0.01 for all). Pre-existing atrial fibrillation (HR: 2.29, 95% CI: 1.47-3.58, P = 0.001) and dialysis therapy (HR: 1.86, 95% CI: 1.17-2.97, P = 0.009) were the predictors of mortality in advanced CKD patients, with a mortality rate as high as 71% at 1-year follow-up in those patients with these 2 factors. Advanced CKD patients who had survived at 1-year follow-up exhibited both a significant improvement in NYHA class (P < 0.001) and no deterioration in valve hemodynamics (P = NS for changes in mean gradient and valve area over time). CONCLUSIONS: Advanced CKD was associated with a higher rate of early and late mortality and bleeding events following TAVI, with AF and dialysis therapy determining a higher risk in these patients. The mortality rate of patients with both factors was unacceptably high and this should be taken into account in the clinical decision-making process in this challenging group of patients.


Assuntos
Estenose da Valva Aórtica/cirurgia , Insuficiência Renal Crônica/complicações , Substituição da Valva Aórtica Transcateter/métodos , Idoso , Estenose da Valva Aórtica/complicações , Estenose da Valva Aórtica/mortalidade , Feminino , Hemodinâmica/fisiologia , Humanos , Estimativa de Kaplan-Meier , Tempo de Internação , Masculino , Hemorragia Pós-Operatória/etiologia , Hemorragia Pós-Operatória/mortalidade , Prognóstico , Insuficiência Renal Crônica/mortalidade , Acidente Vascular Cerebral/etiologia , Acidente Vascular Cerebral/mortalidade , Substituição da Valva Aórtica Transcateter/instrumentação , Substituição da Valva Aórtica Transcateter/mortalidade , Resultado do Tratamento
12.
Artigo em Inglês, Espanhol | MEDLINE | ID: mdl-38763211

RESUMO

INTRODUCTION AND OBJECTIVES: In patients undergoing percutaneous coronary intervention (PCI) in the workup pre-transcatheter aortic valve replacement (TAVR), the clinical impact of coronary revascularization complexity remains unknown. This study sought to examine the impact of PCI complexity on clinical outcomes after TAVR in patients undergoing PCI in the preprocedural workup. METHODS: This was a multicenter study including consecutive patients scheduled for TAVR with concomitant significant coronary artery disease. Complex PCI was defined as having at least 1 of the following features: 3 vessels treated, ≥ 3 stents implanted, ≥ 3 lesions treated, bifurcation with 2 stents implanted, total stent length >60mm, or chronic total occlusion. The rates of major adverse cardiac events (MACE), including cardiovascular mortality, myocardial infarction, and coronary revascularization were evaluated. RESULTS: A total of 1550 patients were included, of which 454 (29.3%) underwent complex PCI in the pre-TAVR workup. After a median follow-up period of 2 [1-3] years after TAVR, the incidence of MACE was 9.6 events per 100 patients-years. Complex PCI significantly increased the risk of cardiac death (HR, 1.44; 95%CI, 1.01-2.07), nonperiprocedural myocardial infarction (HR, 1.52; 95%CI, 1.04-2.21), and coronary revascularization (HR, 2.46; 95%CI, 1.44-4.20). In addition, PCI complexity was identified as an independent predictor of MACE after TAVR (HR, 1.31; 95%CI, 1.01-1.71; P=.042). CONCLUSIONS: In TAVR candidates with significant coronary artery disease requiring percutaneous treatment, complex revascularization was associated with a higher risk of MACE. The degree of procedural complexity should be considered a strong determinant of prognosis in the PCI-TAVR population.

13.
Artigo em Inglês | MEDLINE | ID: mdl-36674216

RESUMO

This paper describes an empirical study carried out with 40 Spanish deaf people, users of sign language, between 19 and 45 years of age, which gathers their perceptions of aspects related to the incidence of the COVID-19 pandemic and its repercussions. During the pandemic, people with hearing disabilities, among other groups, were forgotten. They suffered from accessibility problems to the information issued by the authorities, violating their right to be informed and exposing their health to COVID-19. In this work, we identify the problems they suffered and what effects COVID-19 had on their lives. This will help to take the appropriate measures to restore their rights and design policies and strategies to deal with any new future health emergency. For this, an ad hoc questionnaire was designed, adapted to easy reading and sign language. This was publicized via email and WhatsApp through the Association of Deaf People of Granada and Province (Spain) and was responded to online and by video call with the collaboration of sign language interpreters using the LimeSurvey platform. The results discover (1) the difficulties of communication barriers in the relationship with health professionals and institutions, as well as in the spheres of work and education, (2) similarities with the rest of the population in the negative effects of confinement, and (3) presence of positive effects, such as the development of positive activities and emotions. The study highlights the need to increase economic and institutional support aimed at improving coping resources, access to information, and the reduction of social and institutional barriers that would allow people with hearing disabilities to successfully face future health problems of a global nature such as that experienced with COVID-19.


Assuntos
COVID-19 , Pandemias , Humanos , Acessibilidade aos Serviços de Saúde , COVID-19/epidemiologia , Audição , Percepção
14.
JACC Cardiovasc Interv ; 16(24): 3016-3023, 2023 Dec 25.
Artigo em Inglês | MEDLINE | ID: mdl-37902144

RESUMO

BACKGROUND: The SavvyWire (OpSens Inc) is a 0.035-inch preshaped guidewire with dedicated pacing properties and a distal pressure sensor allowing for continuous hemodynamic pressure monitoring. OBJECTIVES: This study sought to determine the efficacy and safety of the guidewire during transcatheter aortic valve replacement (TAVR) procedures. METHODS: This prospective, multicenter clinical study included patients with severe aortic stenosis undergoing TAVR in 8 European centers. The primary efficacy endpoint was defined as effective left ventricular rapid pacing runs with the guidewire translating into a significant systemic pressure drop (below 60 mm Hg). The safety outcome included the absence of major procedural complications related to the guidewire. RESULTS: A total of 121 patients (mean age: 82.2 ± 5.9 years, 50% women) were included in the study, and 119 (98.3%) patients were finally treated with the study device. A balloon-expandable valve was implanted in 45 (37.8%) patients. Predilatation and postdilatation were performed in 89 (74.8%) and 14 (11.8%) patients, respectively. The primary efficacy endpoint was achieved in 116 (98.3%) patients, and the mean aortic systolic arterial pressure achieved during rapid pacing was 46.6 ± 11.3 mm Hg. Hemodynamic assessment with the use of the OptoMonitor 3 (OpSens Inc) without additional catheter exchange was achieved in 117 (99.2%) patients. The safety endpoint was achieved in 117 (99.2%) patients. No procedural mortality, stroke, or ventricular perforation was reported. CONCLUSIONS: The use of the guidewire during TAVR procedures appeared to be efficacious and safe. This device could help minimize interventions during the procedure and improve the clinical decision making after transcatheter heart valve deployment. (SavvyWire Efficacy and Safety in Transcatheter Aortic Valve Implantation Procedures [SAFE-TAVI]; NCT05492383).


Assuntos
Estenose da Valva Aórtica , Próteses Valvulares Cardíacas , Substituição da Valva Aórtica Transcateter , Humanos , Feminino , Idoso , Idoso de 80 Anos ou mais , Masculino , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/cirurgia , Estenose da Valva Aórtica/diagnóstico por imagem , Estenose da Valva Aórtica/cirurgia , Estudos Prospectivos , Resultado do Tratamento
15.
Artigo em Inglês, Espanhol | MEDLINE | ID: mdl-38000627

RESUMO

INTRODUCTION AND OBJECTIVES: There are scarce data on the factors associated with impaired functional status after transcatheter aortic valve replacement (TAVR) and its clinical impact. This study aimed to determine the incidence, predictors, and prognostic implications of impaired functional class (NYHA class III-IV) following TAVR. METHODS: This multicenter study included 3462 transarterial TAVR patients receiving newer generation devices. The patients were compared according to their NYHA class at 1 month of follow-up (NYHA I-II vs NYHA III-IV). A multivariate logistic regression was performed to identify the predictors of 30-day NYHA class III-IV. Patient survival was compared with the Kaplan-Meier method and factors associated with decreased survival were identified with Cox regression analysis. RESULTS: The mean age of the study population was 80.3±7.3 years, with 47% of women, and a median Society of Thoracic Surgeons score of 3.8% [IQR, 2.5-5.8]. A total of 208 patients (6%) were in NYHA class III-IV 1 month after TAVR. Predictors of 30-day NYHA class III-IV were baseline NYHA class III-IV (OR, 1.76; 95%CI, 1.08-2.89; P=.02), chronic pulmonary obstructive disease (OR, 1.80; 95%CI, 1.13-2.83; P=.01), and post-TAVR severe mitral regurgitation (OR, 2.00; 95%CI, 1.21-3.31; P<.01). Patients in NYHA class III-IV 1 month after TAVR were at higher risk of death (HR, 3.68; 95%CI, 2.39-5.70; P<.01) and heart failure-related hospitalization (HR, 6.00; 95%CI, 3.76-9.60; P<.01) at 1-year follow-up. CONCLUSIONS: Up to 6% of contemporary TAVR patients exhibited an impaired functional status following TAVR. Worse baseline NYHA class, chronic pulmonary obstructive disease, and severe mitral regurgitation predicted 30-day NYHA class III/IV, and this determined a higher risk of mortality and heart failure hospitalization at 1-year follow-up. Further studies on the prevention and treatment optimization of patients with impaired functional status after TAVR are needed.

16.
JACC Cardiovasc Interv ; 16(17): 2153-2164, 2023 09 11.
Artigo em Inglês | MEDLINE | ID: mdl-37704301

RESUMO

BACKGROUND: In patients undergoing percutaneous coronary intervention (PCI) in the work-up pre-transcatheter aortic valve replacement (TAVR), the incidence and clinical impact of late bleeding events (LBEs) remain largely unknown. OBJECTIVES: This study sought to determine the incidence, clinical characteristics, associated factors, and outcomes of LBEs in patients undergoing PCI in the work-up pre-TAVR. METHODS: This was a multicenter study including 1,457 consecutive patients (mean age 81 ± 7 years; 41.5% women) who underwent TAVR and survived beyond 30 days. LBEs (>30 days post-TAVR) were defined according to the Valve Academic Research Consortium-2 criteria. RESULTS: LBEs occurred in 116 (7.9%) patients after a median follow-up of 23 (IQR: 12-40) months. Late bleeding was minor, major, and life-threatening or disabling in 21 (18.1%), 63 (54.3%), and 32 (27.6%) patients, respectively. Periprocedural (<30 days post-TAVR) major bleeding and the combination of antiplatelet and anticoagulation therapy at discharge were independent factors associated with LBEs (P ≤ 0.02 for all). LBEs conveyed an increased mortality risk at 4-year follow-up compared with no bleeding (43.9% vs 36.0; P = 0.034). Also, LBE was identified as an independent predictor of all-cause mortality after TAVR (HR: 1.39; 95% CI: 1.05-1.83; P = 0.020). CONCLUSIONS: In TAVR candidates with concomitant significant coronary artery disease requiring percutaneous treatment, LBEs after TAVR were frequent and associated with increased mortality. Combining antiplatelet and anticoagulation regimens and the occurrence of periprocedural bleeding determined an increased risk of LBEs. Preventive strategies should be pursued for preventing late bleeding after TAVR, and further studies are needed to provide more solid evidence on the most safe and effective antithrombotic regimen post-TAVR in this challenging group of patients.


Assuntos
Intervenção Coronária Percutânea , Substituição da Valva Aórtica Transcateter , Humanos , Feminino , Idoso , Idoso de 80 Anos ou mais , Masculino , Intervenção Coronária Percutânea/efeitos adversos , Substituição da Valva Aórtica Transcateter/efeitos adversos , Resultado do Tratamento , Hemorragia/induzido quimicamente , Catéteres
17.
Circ Cardiovasc Interv ; 16(3): e012554, 2023 03.
Artigo em Inglês | MEDLINE | ID: mdl-36943930

RESUMO

BACKGROUND: The potential benefit of using larger or smaller transcatheter heart valves (THV) in patients with borderline aortic annulus measurement (BAM) remains uncertain. The objective of this study was to evaluate the clinical outcomes associated with the selection of larger or smaller THV in the context of BAM. METHODS: This was a multicenter observational study including patients who underwent transcatheter aortic valve replacement with the SAPIEN 3 or SAPIEN 3 Ultra-valve systems (Edwards Lifesciences, Irvine, CA) from April 2014 to June 2021. BAM was defined according to the manufacturer sizing chart and included the following annulus areas: 314 to 346, 400 to 430, 500 to 546 mm2. A 1:1 propensity score matching was used to compare outcomes of patients with larger or smaller THV. RESULTS: From a total of 2467 patients, BAM was identified in 852 patients (34.5%). A larger and smaller THV was selected in 338 (39.7%) and 514 patients (60.3%) patients, respectively. The choice of a larger THV was associated (before and after propensity matching) with a higher risk of new-onset left bundle branch block (HR, 2.25 [95% CI, 1.39-3.65; P=0.001) and permanent pacemaker implantation (HR, 1.86 [95% CI, 1.11-3.09]; P=0.016) without any impact on gradients or the risk of moderate or severe paravalvular regurgitation at discharge (HR, 0.78 [95% CI, 0.41-1.45]; P=0.427). The risk of periprocedural complications such as aortic rupture and tamponade was low (<1%) and similar between groups. CONCLUSIONS: In patient with BAM, selecting a larger SAPIEN 3/Ultra THV increased the risk of conduction disturbances without any benefit on valve hemodynamics and clinical outcomes.


Assuntos
Insuficiência da Valva Aórtica , Estenose da Valva Aórtica , Próteses Valvulares Cardíacas , Substituição da Valva Aórtica Transcateter , Humanos , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/cirurgia , Insuficiência da Valva Aórtica/diagnóstico por imagem , Insuficiência da Valva Aórtica/etiologia , Insuficiência da Valva Aórtica/cirurgia , Estenose da Valva Aórtica/diagnóstico por imagem , Estenose da Valva Aórtica/cirurgia , Estenose da Valva Aórtica/complicações , Próteses Valvulares Cardíacas/efeitos adversos , Resultado do Tratamento , Substituição da Valva Aórtica Transcateter/efeitos adversos , Desenho de Prótese
18.
JACC Cardiovasc Interv ; 16(18): 2277-2290, 2023 09 25.
Artigo em Inglês | MEDLINE | ID: mdl-37758382

RESUMO

BACKGROUND: The burden of cardiac death after transcatheter aortic valve replacement (TAVR), particularly from advanced heart failure (HF) and sudden cardiac death (SCD), remains largely unknown. OBJECTIVES: This study sought to evaluate the incidence and predictors of SCD and HF-related death in TAVR recipients treated with newer-generation devices. METHODS: This study included a total of 5,421 consecutive patients who underwent TAVR with newer-generation devices using balloon (75.7%) or self-expandable (24.3%) valves. RESULTS: After a median follow-up of 2 (IQR: 1-3) years, 976 (18.0%) patients had died, 50.8% from cardiovascular causes. Advanced HF and SCD accounted for 11.6% and 7.5% of deaths, respectively. Independent predictors of HF-related death were atrial fibrillation (HR: 2.17; 95% CI: 1.47-3.22; P < 0.001), prior pacemaker (HR: 1.79; 95% CI: 1.10-2.92; P = 0.01), reduced left ventricular ejection fraction (HR: 1.08 per 5% decrease; 95% CI: 1.01-1.14; P = 0.02), transthoracic approach (HR: 2.50; 95% CI: 1.37-4.55; P = 0.003), and new-onset persistent left bundle branch block (HR: 1.85; 95% CI: 1.14-3.02; P = 0.01). Two baseline characteristics (diabetes, HR: 1.81; 95% CI: 1.13-2.89; P = 0.01; and chronic kidney disease, HR: 1.72; 95% CI: 1.02-2.90; P = 0.04) and 3 procedural findings (valve in valve, HR: 2.17; 95% CI: 1.01-4.64; P = 0.04; transarterial nontransfemoral approach, HR: 2.23; 95% CI: 1.23-4.48; P = 0.01; and periprocedural ventricular arrhythmia, HR: 7.19; 95% CI: 2.61-19.76; P < 0.001) were associated with an increased risk of SCD after TAVR. CONCLUSIONS: Advanced HF and SCD accounted for a fifth of deaths after TAVR in contemporary practice. Potentially treatable factors leading to increased risk of HF deaths and SCD were identified, such as arrhythmia/dyssynchrony factors for HF and valve-in-valve TAVR or periprocedural ventricular arrhythmias for SCD.


Assuntos
Estenose da Valva Aórtica , Substituição da Valva Aórtica Transcateter , Humanos , Substituição da Valva Aórtica Transcateter/efeitos adversos , Volume Sistólico , Estenose da Valva Aórtica/diagnóstico por imagem , Estenose da Valva Aórtica/cirurgia , Fatores de Risco , Função Ventricular Esquerda , Resultado do Tratamento , Arritmias Cardíacas/terapia , Morte Súbita Cardíaca/epidemiologia , Morte Súbita Cardíaca/etiologia , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/cirurgia
19.
Am Heart J ; 163(2): 288-94, 2012 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-22305849

RESUMO

BACKGROUND: Few data exist on the clinical impact of transcatheter aortic valve implantation (TAVI) in patients with symptomatic aortic stenosis and a high surgical risk. The aim of this study was to determine the survival and the factors predicting mortality after 30 days post-TAVI with the CoreValve prosthesis (Medtronic, Minneapolis, MN). METHODS: From April 2008 to October 2010, the CoreValve prosthesis (Medtronic) was implanted in 133 consecutive high-risk surgical patients with symptomatic severe aortic stenosis. RESULTS: The mean age was 79.5 ± 6.7 years. The logistic European System for Cardiac Operative Risk Evaluation was 21.5% ± 14%. The implantation success rate was 97.7%. In-hospital mortality was 4.5%, and the combined end point of death, vascular complications, myocardial infarction, or stroke had a rate of 9%. Survival at 12 and 24 months was 84.5% and 79%, respectively, after a mean follow-up of 11.3 ± 8 months. The New York Heart Association functional class improved from 3.3 ± 0.5 to 1.18 ± 0.4 and remained stable at 1 year. A high Charlson index (hazard ratio [HR] 1.44, 95% CI 1.09-1.89, P < .01) and a worse Karnofsky score before the procedure (HR 0.95, 95% CI 0.92-0.99, P = .021) were predictors of mortality after 30 days. CONCLUSIONS: Transcatheter aortic valve implantation with the CoreValve prosthesis for patients with aortic stenosis and a high surgical risk is a safe, efficient option resulting in a medium-term clinical improvement. Survival during follow-up depends on the associated comorbidities. Early mortality beyond 30 days is predicted by preoperative comorbidity scores and the functional status of the patient.


Assuntos
Estenose da Valva Aórtica/mortalidade , Cateterismo Cardíaco/métodos , Próteses Valvulares Cardíacas , Idoso , Estenose da Valva Aórtica/cirurgia , Feminino , Mortalidade Hospitalar/tendências , Humanos , Masculino , Prognóstico , Desenho de Prótese , Fatores de Risco , Índice de Gravidade de Doença , Espanha/epidemiologia , Taxa de Sobrevida/tendências , Fatores de Tempo , Resultado do Tratamento
20.
EuroIntervention ; 18(5): e417-e427, 2022 Aug 05.
Artigo em Inglês | MEDLINE | ID: mdl-35321860

RESUMO

BACKGROUND: Morbidly obese (MO) patients are increasingly undergoing transcatheter aortic valve replacement (TAVR) and surgical aortic valve replacement (SAVR) for severe aortic stenosis (AS). However, the best therapeutic strategy for these patients remains a matter for debate. AIMS: Our aim was to compare the periprocedural and mid-term outcomes in MO patients undergoing TAVR versus SAVR. METHODS: A multicentre retrospective study including consecutive MO patients (body mass index ≥40 kg/m2, or ≥35 kg/m2 with obesity-related comorbidities) from 18 centres undergoing either TAVR (n=860) or biological SAVR (n=696) for severe AS was performed. Propensity score matching resulted in 362 pairs. RESULTS: After matching, periprocedural complications, including blood transfusion (14.1% versus 48.1%; p<0.001), stage 2-3 acute kidney injury (3.99% versus 10.1%; p=0.002), hospital-acquired pneumonia (1.7% versus 5.8%; p=0.005) and access site infection (1.5% versus 5.5%; p=0.013), were more common in the SAVR group, as was moderate to severe patient-prosthesis mismatch (PPM; 9.9% versus 39.4%; p<0.001). TAVR patients more frequently required permanent pacemaker implantation (14.4% versus 5.6%; p<0.001) and had higher rates of ≥moderate residual aortic regurgitation (3.3% versus 0%; p=0.001). SAVR was an independent predictor of moderate to severe PPM (hazard ratio [HR] 1.80, 95% confidence interval [CI]: 1.25-2.59; p=0.002), while TAVR was not. In-hospital mortality was not different between groups (3.9% for TAVR versus 6.1% for SAVR; p=0.171). Two-year outcomes (including all-cause and cardiovascular mortality, and readmissions) were similar in both groups (log-rank p>0.05 for all comparisons). Predictors of all-cause 2-year mortality differed between the groups; moderate to severe PPM was a predictor following SAVR (HR 1.78, 95% CI: 1.10-2.88; p=0.018) but not following TAVR (p=0.737). CONCLUSIONS: SAVR and TAVR offer similar mid-term outcomes in MO patients with severe AS, however, TAVR offers some advantages in terms of periprocedural morbidity.


Assuntos
Estenose da Valva Aórtica , Implante de Prótese de Valva Cardíaca , Obesidade Mórbida , Substituição da Valva Aórtica Transcateter , Valva Aórtica/cirurgia , Implante de Prótese de Valva Cardíaca/métodos , Humanos , Obesidade Mórbida/complicações , Obesidade Mórbida/cirurgia , Pontuação de Propensão , Estudos Retrospectivos , Fatores de Risco , Substituição da Valva Aórtica Transcateter/métodos , Resultado do Tratamento
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA