Am J Orthod Dentofacial Orthop ; 151(3): 607-615, 2017 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-28257745

RESUMO

INTRODUCTION: The purposes of this study were to examine the accuracy and the head positioning effects on measurements of anterior tooth length using 3-dimensional (3D) and conventional dental panoramic radiography and to investigate whether 3D panoramic radiography is suitable for the evaluation of anterior tooth length. METHODS: A simulated human head was radiographed at 4, 8, and 12 mm displaced positions, and at 5°, 10°, and 15° tilted positions from the standard head position using 3D and conventional panoramic radiography, and also using cone-beam computed tomography. Anterior tooth lengths were measured on the panoramic and cone-beam computed tomography images. The values for the standard head position in the panoramic radiographs were defined as the standard values. Measurement error was defined as the standard value minus the cone-beam computed tomography value on each panoramic radiograph. The head position ratio of the measurement value to the standard value at each head position was calculated. RESULTS: Measurement errors for the 3D panoramic radiographs were significantly smaller than those for the conventional panoramic radiographs. In the 3D panoramic radiographs, the head position ratios at the 4, 8, and 12 mm displaced positions and at the 5° tilted position were within ±5% of the standard value. CONCLUSIONS: Three-dimensional panoramic radiography is suitable for the quantitative evaluation of anterior tooth length with high accuracy.


Assuntos
Cabeça/anatomia & histologia , Imageamento Tridimensional , Incisivo/diagnóstico por imagem , Radiografia Panorâmica/métodos , Tomografia Computadorizada de Feixe Cônico , Humanos , Imagens de Fantasmas
2.
Angle Orthod ; 83(1): 117-26, 2013 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-22612390

RESUMO

OBJECTIVE: To investigate measurement errors and head positioning effects on radiographs made with new dental panoramic radiograph equipment that uses tomosynthesis. MATERIALS AND METHODS: Radiographic images of a simulated human head or phantom were made at standard head positions using the new dental panoramic radiograph equipment. Measurement errors were evaluated by comparing with the true values. The phantom was also radiographed at various alternative head positions. Significant differences between measurement values at standard and alternative head positions were evaluated. Magnification ratios of the dimensions at standard and alternative head positions were calculated. RESULTS: The measurement errors were small for all dimensions. On the measurements at 4-mm displacement positions, no dimension was significantly different from the standard value, and all dimensions were within ±5% of the standard values. At 12-mm displacement positions, the magnification ratios for tooth length and mandibular ramus height were within ±5% of the standard values, but those for dental arch width, mandibular width, and mandibular body length were beyond ±5% of the standard values. CONCLUSIONS: Measurement errors on radiographs made using the new panoramic radiograph equipment were small in any direction. At 4-mm head displacement positions, no head positioning effect on the measurements was found. At 12-mm head displacement positions, the measurements for vertical dimensions were little affected by head positioning, while those for lateral and anteroposterior dimensions were strongly affected.


Assuntos
Cefalometria/instrumentação , Ampliação Radiográfica/normas , Radiografia Panorâmica/instrumentação , Cefalometria/métodos , Precisão da Medição Dimensional , Humanos , Processamento de Imagem Assistida por Computador , Posicionamento do Paciente , Imagens de Fantasmas , Radiografia Panorâmica/métodos