1.
Circ J ; 88(7): 1118-1124, 2024 Jun 25.
Artigo em Inglês | MEDLINE | ID: mdl-38616125

RESUMO

BACKGROUND: Despite an increased incidence of chronic heart failure (HF) and sudden cardiac death (SCD), the use of implantable cardioverter-defibrillators (ICDs) and cardiac resynchronization therapy (CRT) is much lower in Japan than in Western countries. The HF Indication and SCD Prevention Trial Japan (HINODE) prospectively assessed the mortality rate, appropriately treated ventricular arrhythmias (VA), and HF in Japanese patients with a higher risk of HF.Methods and Results: HINODE consisted of ICD, CRT-defibrillator (CRT-D), pacing, and non-device treatment cohorts. This subanalysis evaluated the impact of the implantation of high-voltage devices (HVD; ICD and CRT-D) in 171 Japanese patients. We compared all-cause mortality, VA, and HF events between elderly (age >70 years at study enrollment) and non-elderly HVD recipients. The estimated survival rate through 24 months in the HVD cohort was 85.8% (97.5% lower control limit 77.6%). The risk of all-cause mortality was increased for the elderly vs. non-elderly (hazard ratio [HR] 2.82; 95% confidence interval [CI] 1.01-7.91; P=0.039), but did not differ after excluding ICD patients with CRT-D indication (HR 2.32; 95% CI 0.79-6.78; P=0.11). There were no differences in VA and HF event-free rates between elderly and non-elderly HVD recipients (P=0.73 and P=0.55, respectively). CONCLUSIONS: Although elderly patients may have a higher risk of mortality in general, the benefit of HVD therapy in this group is comparable to that in non-elderly patients.


Assuntos
Terapia de Ressincronização Cardíaca , Desfibriladores Implantáveis , Insuficiência Cardíaca , Humanos , Idoso , Insuficiência Cardíaca/mortalidade , Insuficiência Cardíaca/terapia , Masculino , Feminino , Japão/epidemiologia , Idoso de 80 Anos ou mais , Pessoa de Meia-Idade , Prevenção Primária , Estudos Prospectivos , Morte Súbita Cardíaca/prevenção & controle , Fatores Etários , Fatores de Risco , População do Leste Asiático
2.
Heart Vessels ; 38(12): 1459-1467, 2023 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-37650926

RESUMO

Myocardium baseline impedance (BI) is an important factor in ablation effectiveness. This study examined the performance of low-power and long-duration (LPLD), high-power and short-duration (HPSD) ablation at different BIs by computer simulation. A 3D model of the ablation region was constructed for simulation, and in vitro experiments were performed to validate the simulation. Three ablation power and duration configurations of 30 W/30 s, 50 W/10 s, and 90 W/5 s were used for simulation with BI values of 90, 100, 110, 120, 130, and 140 Ω. Roll-off time and ablation volume were measured to evaluate ablation results. The simulation is consistent with the in vitro experiments. When BI is changed from 90 [Formula: see text] to 140 [Formula: see text], the lesion volume over 50 °C with BI of 140 [Formula: see text] was reduced by 6.3%, 6.7%, and 7.3% for 30 W/30 s, 50 W/10 s, and 90 W/5 s configurations, respectively, and the lesion volume over 100 °C was reduced by 62.8%, 49.7%, and 22.5% under 30 W/30 s, 50 W/10 s, and 90 W/5 s, respectively. Simulation results revealed that HPSD (vHPSD) and LPLD ablation were more affected by changes in BI in the lesion volumes over 50 °C and 100 °C, respectively, and demonstrated that resistive and conductive heating were the main heating effects in HPSD (vHPSD) and LPLD, respectively.


Assuntos
Fibrilação Atrial , Ablação por Cateter , Veias Pulmonares , Humanos , Simulação por Computador , Impedância Elétrica , Ablação por Cateter/métodos , Miocárdio/patologia , Fatores de Tempo , Fibrilação Atrial/cirurgia , Veias Pulmonares/cirurgia , Resultado do Tratamento
3.
Int Heart J ; 64(6): 1025-1031, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-38030289

RESUMO

The number of TV-PM implantations in elderly people is increasing. Although frailty syndrome is common in elderly patients, the relationship between the pre-procedural frailty status and clinical outcomes has not been fully elucidated in elderly TV-PM recipients.This study included 103 consecutive patients over 80 years old who were newly implanted with a TV-PM (age 85.7 ± 4.2, 41.7% male). We assessed the relationship between the clinical outcome and predictive factors, especially for the pre-procedural frailty status after the TV-PM implantation. The pre-procedural frailty status was retrospectively assessed from the medical records and classified on the basis of impairments in 3 domains (walking, cognition, and activities of daily living). The primary endpoint was defined as a heart failure admission.During the follow-up period (4.1 ± 2.3 years), 20 patients (19.4%) met the primary endpoint. Frailty syndrome was identified in 40 patients (38.8%). In univariate analysis, the LVEF (HR 0.97, 95% CI 0.96-1.00 P = 0.0492), an RV pacing burden over 40% (HR 1.58, 95% CI 1.00-2.54 P = 0.0473), and presence of a frailty status (HR 1.82, 95% CI 1.13-2.87 P = 0.0134) were found to be statistically significant predictors for the study endpoint. In multivariate analysis, having frailty syndrome was the only predictive factor for a heart failure admission (HR 1.83, 95% CI 1.12-2.93 P = 0.0157).The presence of frailty syndrome and incidence of clinical events were high and a pre-procedural frailty status assessment was key in determining the clinical outcomes in TV-PM recipients over 80 years old.


Assuntos
Fragilidade , Insuficiência Cardíaca , Marca-Passo Artificial , Humanos , Masculino , Idoso , Idoso de 80 Anos ou mais , Feminino , Fragilidade/epidemiologia , Idoso Fragilizado , Estudos Retrospectivos , Atividades Cotidianas , Insuficiência Cardíaca/epidemiologia , Insuficiência Cardíaca/terapia
4.
Circ J ; 86(2): 299-308, 2022 01 25.
Artigo em Inglês | MEDLINE | ID: mdl-34629373

RESUMO

BACKGROUND: Radiofrequency catheter ablation (RFCA) is an effective therapy for atrial fibrillation (AF). However, it the problem of AF recurrence remains. This study investigates whether a deep convolutional neural network (CNN) can accurately predict AF recurrence in patients with AF who underwent RFCA, and compares CNN with conventional statistical analysis.Methods and Results:Three-hundred and ten patients with AF after RFCA treatment, including 94 patients with AF recurrence, were enrolled. Nine variables are identified as candidate predictors by univariate Cox proportional hazards regression (CPH). A CNNSurv model for AF recurrence prediction was proposed. The model's discrimination ability is validated by a 10-fold cross validation method and measured by C-index. After back elimination, 4 predictors are used for model development, they are N-terminal pro-BNP (NT-proBNP), paroxysmal AF (PAF), left atrial appendage volume (LAAV) and left atrial volume (LAV). The average testing C-index is 0.76 (0.72-0.79). The corresponding calibration plot appears to fit well to a diagonal, and the P value of the Hosmer-Lemeshow test also indicates the proposed model has good calibration ability. The proposed model has superior performance compared with the DeepSurv and multivariate CPH. The result of risk stratification indicates that patients with non-PAF, higher NT-proBNP, larger LAAV and LAV would have higher risks of AF recurrence. CONCLUSIONS: The proposed CNNSurv model has better performance than conventional statistical analysis, which may provide valuable guidance for clinical practice.


Assuntos
Fibrilação Atrial , Ablação por Cateter , Aprendizado Profundo , Fibrilação Atrial/diagnóstico , Fibrilação Atrial/etiologia , Fibrilação Atrial/cirurgia , Ablação por Cateter/efeitos adversos , Ablação por Cateter/métodos , Humanos , Recidiva , Resultado do Tratamento
5.
Pacing Clin Electrophysiol ; 44(1): 192-193, 2021 01.
Artigo em Inglês | MEDLINE | ID: mdl-32779758

RESUMO

A 78-year-old male with a history of a cardiac embolic stroke due to persistent AF and cerebral bleeding (CHADS2 score 4, HAS-BLED score 4) was referred to our hospital to implant a left atrial appendage (LAA) closure (LAAC) device. A trans esophageal echocardiography was performed and a high echoic lesion that was difficult to differentiate the spontaneous echo contrast or thrombus was found in the LAA cavity. After isoproterenol infusion, a high echoic lesion disappeared and we confirmed that it was not an LAA thrombus. Successful LAAC device implantation was performed without any thromboembolic events.


Assuntos
Agonistas Adrenérgicos beta/administração & dosagem , Apêndice Atrial/diagnóstico por imagem , Apêndice Atrial/cirurgia , Isoproterenol/administração & dosagem , Dispositivo para Oclusão Septal , Idoso , Ecocardiografia Transesofagiana , Humanos , Infusões Intravenosas , Imageamento por Ressonância Magnética , Masculino
6.
Pacing Clin Electrophysiol ; 44(11): 1810-1816, 2021 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-34554589

RESUMO

BACKGROUND: Transvenous implantable cardioverter defibrillator (TV-ICD) systems are commonly implanted in the left anterior chest because of an easier implantation and better defibrillation threshold. This study aimed to evaluate the safety and feasibility of left axillary implantations of TV-ICD systems. METHODS: We performed left axillary TV-ICD implantations and compared that to the major complication rate and operation time of the conventional TV-ICD implantation site (left anterior chest). The electrical parameter trends were also assessed in the left axilla group. RESULTS: Seventy-six consecutive patients were evaluated for the analysis. Thirty-one patients had their system implanted in the left axilla and the reasons for the implantations included 29 patients for cosmetic reasons and two for post-infection conditions. The operation time and major complication rate were similar between the two groups (left anterior chest vs. left axilla: 134±62.4 min vs. 114±33.5 min, p = .11, 1/45 patient, 2.2% [pocket hematoma] vs. 1/31 patient, 3.2% [lead dislodgement], p = .77). During the follow up period (4.9±2.3years), no lead interruptions were observed in either group. The electrical lead parameters at the time of the implantation and follow up were similar in the study group (R wave sensing 20.8±33.4 vs. 11.2±7.42 mv, p = .34; lead impedance 464±64.7 vs. 418±135ohm, p = .22; pacing threshold [at 0.4 ms] 1.0±0.76 vs. 1.21±0.93V, p = .49). CONCLUSION: TV-ICD implantations in the left axilla were performed safely without increasing the operation time as compared to the conventional ICD implantation site. ICD implantations in the left axilla are an alternative in those not suitable for implanting TV-ICDs in the conventional implantation site.


Assuntos
Axila/cirurgia , Desfibriladores Implantáveis , Segurança do Paciente , Estudos de Viabilidade , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Complicações Pós-Operatórias , Estudos Retrospectivos
7.
Heart Vessels ; 36(9): 1438-1444, 2021 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-33740089

RESUMO

There is increased interest in creating high-power short duration (HPSD) ablation lesions in the field of atrial fibrillation (AF) radiofrequency ablation (RFA). We evaluated the lesion characteristics and collateral damage using two separate RFA protocols setting (HPSD: 50 W and 7 s vs control: 25 W and 30 s) in vitro model. Sixteen freshly killed porcine hearts were obtained, and the atrium and ventricle slabs were harvested for ablation. The each slabs were placed in a tissue bath with circulating 0.9% NaCl at maintained temperature 37 °C. RFA was performed with 4 mm tip irrigated force sensing catheter. All lesions were ablated under recording the electrical parameters using with Ensite Navx system (St. Jude Medical, St. Paul, Minnesota). After RFA, lesion characteristics were assessed for each lesion. Thirty-five lesions were made for each ablation protocol (total 70 lesions for analysis). Ablation parameters were similar between two groups (HPSD vs control; impedance drop (Ω): 34.2 ± 13.1 vs 36.1 ± 8.65 P = 0.49, contact force (g): 13.9 ± 4.37 vs 14.6 ± 5.09, P = 0.51, lesion size index: 4.8 ± 0.52 vs 4.73 ± 0.59, P = 0.62). Although the lesion volume was similar, the HPSD ablation creates wider but more shallower lesions compared to control group (HPSD vs control; lesion volume: 29.6 ± 18.1 mm3 vs 35.5 ± 17.1 mm3 P = 0.16, lesion diameter: 4.98 ± 0.91 mm vs 4.45 ± 0.74 mm P = 0.0095, lesion depth: 2.2 ± 0.76 mm vs 2.8 ± 1.56 mm P = 0.046). Of these, 38 lesions were assessed for adjacent tissue damage and adjacent tissue damages were more frequent seen in control group (HPSD vs control; 1/19 (5.26%) vs 6/19 (31.5%), P = 0.036). Effective lesions were made with HPSD, thereby reducing RFA procedure time. Although the lesion volume was similar between two groups, collateral damage was less seen in HPSD group attributed by lesion characteristics.


Assuntos
Fibrilação Atrial , Ablação por Cateter , Ablação por Radiofrequência , Animais , Fibrilação Atrial/diagnóstico , Fibrilação Atrial/cirurgia , Ventrículos do Coração , Suínos , Fatores de Tempo
8.
J Electrocardiol ; 66: 114-121, 2021.
Artigo em Inglês | MEDLINE | ID: mdl-33906059

RESUMO

BACKGROUND: Atrial fibrillation (AF) induces functional mitral regurgitation (FMR) and tricuspid regurgitation (FTR) during atrial remodeling. FMR and FTR are associated with AF prognosis, but the effects for AF recurrence after ablation have not been determined conclusively. METHODS: Two hundred thirty nine patients who underwent AF ablation were enrolled. Forty five patients were excluded. In total, 194 patients were analyzed. FMR and FTR were assessed by echocardiography. The left atrial volume index (LAVI) was evaluated by contrast-enhanced computed tomography. RESULTS: Significant FMR and moderate FTR were observed in 15 (7.7%) and in 25 (12.9%) patients, respectively. The severity of tricuspid regurgitation (TR) significant correlated with age, NT-proBNP, and LAVI. During a 13.4 month follow-up period of, 39 patients (20.1%) demonstrated AF recurrence. In the Cox proportional-hazards model, E/e', FTR, and LAVI, were termed as predictor factors of AF recurrence (E/e'. hazard ratio [HR] = 1.117; P = 0.019, significant FTR. HR = 4.679; P = 0.041, LAVI. HR = 1.057; P = 0.003). Kaplan-Meier analysis showed that AF recurrence was more frequent in FTR compared with the nonsignificant FTR cases (log-rank, P = 0.001). Although survival analysis showed no difference with or without FMR, the presence of FMR and FTR was strongly associated with high-AF recurrence (log-rank, P = 0.004). CONCLUSIONS: AF recurrence was associated with E/e', LAVI, and extensive FTR. Specifically, the combination of FTR and FMR markedly worsens the AF prognosis.


Assuntos
Fibrilação Atrial , Insuficiência da Valva Mitral , Insuficiência da Valva Tricúspide , Fibrilação Atrial/cirurgia , Eletrocardiografia , Átrios do Coração , Humanos , Insuficiência da Valva Mitral/cirurgia , Insuficiência da Valva Tricúspide/diagnóstico por imagem , Insuficiência da Valva Tricúspide/cirurgia
9.
Int Heart J ; 60(6): 1444-1447, 2019 Nov 30.
Artigo em Inglês | MEDLINE | ID: mdl-31666453

RESUMO

A healthy 73-year-old woman unpredictably developed Takotsubo cardiomyopathy syndrome (TTS) during Holter-electrocardiogram (ECG) recording. Thus, the complete chronological ECG data on the actual onset day of TTS were obtained. Many heart rate variability (HRV) parameters, including the low-frequency components (LF) and the high-frequency components (HF), on the actual onset day and in the healing phase were calculated. The interesting facts on the actual onset day were that the suppression of both LF and HF appeared earlier than the changes of the ECG waveform; and the LF/HF ratio remained within the normal range, although both LF and HF were markedly suppressed. The abnormality on the actual onset day was clear compared with the healing phase. It is noteworthy to obtain the chronological ECG data on the actual onset day of TTS in a healthy patient. The present data are unique in terms of being analyzed on the actual onset day. Although the HRV parameters, including LF and HF, were obviously abnormal, there is some skepticism about using HRV parameters as indices of cardiac autonomic activity. In the present case, it was concluded that the abnormality of cardiac autonomic activity contributed to the onset of TTS. These data are unlikely to ever be replicated, and we hope that this report helps elucidate the TTS mechanism.


Assuntos
Frequência Cardíaca/fisiologia , Cardiomiopatia de Takotsubo/diagnóstico , Cardiomiopatia de Takotsubo/fisiopatologia , Idoso , Eletrocardiografia Ambulatorial , Feminino , Humanos
10.
Int Heart J ; 59(2): 439-442, 2018 Mar 30.
Artigo em Inglês | MEDLINE | ID: mdl-29526888

RESUMO

A 70-years-old male with a history of hypertension and drug resistant paroxysmal atrial fibrillation (AF) presented to our hospital for catheter ablation to his symptomatic AF. He had no prior surgical or percutaneous procedure to close or exclude the left atrial appendage (LAA). A transesophageal echocardiography (TEE) was performed to rule out intra-cardiac thrombus prior to the ablation procedure. Although the TEE imaging at multiple acquisition angles was obtained, the LAA could not be visualized and an absence of the LAA was suspected. An absence of the LAA was confirmed using cardiac computed tomography (CT), which included 3D reconstruction. Additionally, the LAA was not visualized with left atrium (LA) angiography. During the ablation procedure, 3D voltage mapping in LA was created and no low voltage area or abnormal potential was recorded around the usual root location of the LAA. Successful electrical pulmonary vein isolation was achieved with no major complications. After six months of follow-up, the patient remained in sinus rhythm without any antiarrhythmic drugs and showed no related clinical symptoms. He stopped his anticoagulation therapy due to lack of evidence of AF recurrence and an absence of LAA. Multimodality imaging allowed us to identify the congenital absence of LAA.


Assuntos
Apêndice Atrial/anormalidades , Apêndice Atrial/diagnóstico por imagem , Imagem Multimodal , Idoso , Fibrilação Atrial/diagnóstico por imagem , Fibrilação Atrial/etiologia , Fibrilação Atrial/terapia , Ecocardiografia Transesofagiana , Humanos , Imageamento Tridimensional , Masculino , Tomografia Computadorizada por Raios X
11.
Am J Physiol Heart Circ Physiol ; 312(3): H392-H405, 2017 Mar 01.
Artigo em Inglês | MEDLINE | ID: mdl-28011590

RESUMO

Cardiac sympathetic denervation (CSD) is reported to reduce the burden of ventricular tachyarrhythmias [ventricular tachycardia (VT)/ventricular fibrillation (VF)] in cardiomyopathy patients, but the mechanisms behind this benefit are unknown. In addition, the relative contribution to cardiac innervation of the middle cervical ganglion (MCG), which may contain cardiac neurons and is not removed during this procedure, is unclear. The purpose of this study was to compare sympathetic innervation of the heart via the MCG vs. stellate ganglia, assess effects of bilateral CSD on cardiac function and VT/VF, and determine changes in cardiac sympathetic innervation after CSD to elucidate mechanisms of benefit in 6 normal and 18 infarcted pigs. Electrophysiological and hemodynamic parameters were evaluated at baseline, during bilateral stellate stimulation, and during bilateral MCG stimulation in 6 normal and 12 infarcted animals. Bilateral CSD (removal of bilateral stellates and T2 ganglia) was then performed and MCG stimulation repeated. In addition, in 18 infarcted animals VT/VF inducibility was assessed before and after CSD. In infarcted hearts, MCG stimulation resulted in greater chronotropic and inotropic response than stellate ganglion stimulation. Bilateral CSD acutely reduced VT/VF inducibility by 50% in infarcted hearts and prolonged global activation recovery interval. CSD mitigated effects of MCG stimulation on dispersion of repolarization and T-peak to T-end interval in infarcted hearts, without causing hemodynamic compromise. These data demonstrate that the MCG provides significant cardiac sympathetic innervation before CSD and adequate sympathetic innervation after CSD, maintaining hemodynamic stability. Bilateral CSD reduces VT/VF inducibility by improving electrical stability in infarcted hearts in the setting of sympathetic activation.NEW & NOTEWORTHY Sympathetic activation in myocardial infarction leads to arrhythmias and worsens heart failure. Bilateral cardiac sympathetic denervation reduces ventricular tachycardia/ventricular fibrillation inducibility and mitigates effects of sympathetic activation on dispersion of repolarization and T-peak to T-end interval in infarcted hearts. Hemodynamic stability is maintained, as innervation via the middle cervical ganglion is not interrupted.


Assuntos
Arritmias Cardíacas/fisiopatologia , Arritmias Cardíacas/cirurgia , Gânglios Simpáticos/fisiopatologia , Gânglios Simpáticos/cirurgia , Coração/inervação , Gânglio Estrelado/fisiopatologia , Gânglio Estrelado/cirurgia , Simpatectomia , Sistema Nervoso Simpático/fisiopatologia , Sistema Nervoso Simpático/cirurgia , Animais , Arritmias Cardíacas/metabolismo , Estimulação Cardíaca Artificial , Estimulação Elétrica , Frequência Cardíaca , Contração Miocárdica , Infarto do Miocárdio/complicações , Infarto do Miocárdio/fisiopatologia , Norepinefrina/metabolismo , Suínos , Sistema Nervoso Simpático/metabolismo , Taquicardia Ventricular/metabolismo , Taquicardia Ventricular/fisiopatologia , Taquicardia Ventricular/cirurgia , Fibrilação Ventricular/metabolismo , Fibrilação Ventricular/fisiopatologia , Fibrilação Ventricular/cirurgia
12.
J Physiol ; 594(2): 321-41, 2016 Jan 15.
Artigo em Inglês | MEDLINE | ID: mdl-26572244

RESUMO

KEY POINTS: Intrinsic cardiac (IC) neurons undergo differential morphological and phenotypic remodelling that reflects the site of myocardial infarction (MI). Afferent neural signals from the infarcted region to IC neurons are attenuated, while those from border and remote regions are preserved post-MI, giving rise to a 'neural sensory border zone'. Convergent IC local circuit (processing) neurons have enhanced transduction capacity following MI. Functional network connectivity within the intrinsic cardiac nervous system is reduced post-MI. MI reduces the response and alters the characteristics of IC neurons to ventricular pacing. ABSTRACT: Autonomic dysregulation following myocardial infarction (MI) is an important pathogenic event. The intrinsic cardiac nervous system (ICNS) is a neural network located on the heart that is critically involved in autonomic regulation. The aims of this study were to characterize structural and functional remodelling of the ICNS post-MI in a porcine model (control (n = 16) vs. healed anteroapical MI (n = 16)). In vivo microelectrode recordings of basal activity, as well as responses to afferent and efferent stimuli, were recorded from intrinsic cardiac neurons. From control 118 neurons and from MI animals 102 neurons were functionally classified as afferent, efferent, or convergent (receiving both afferent and efferent inputs). In control and MI, convergent neurons represented the largest subpopulation (47% and 48%, respectively) and had enhanced transduction capacity following MI. Efferent inputs to neurons were maintained post-MI. Afferent inputs were attenuated from the infarcted region (19% in control vs. 7% in MI; P = 0.03), creating a 'neural sensory border zone', or heterogeneity in afferent information. MI reduced transduction of changes in preload (54% in control vs. 41% in MI; P = 0.05). The overall functional network connectivity, or the ability of neurons to respond to independent pairs of stimuli, within the ICNS was reduced following MI. The neuronal response was differentially decreased to ventricular vs. atrial pacing post-MI (63% in control vs. 44% in MI to ventricular pacing; P < 0.01). MI induced morphological and phenotypic changes within the ICNS. The alteration of afferent neural signals, and remodelling of convergent neurons, represents a 'neural signature' of ischaemic heart disease.


Assuntos
Sistema Nervoso Autônomo/fisiopatologia , Infarto do Miocárdio/fisiopatologia , Plasticidade Neuronal , Neurônios/fisiologia , Potenciais de Ação , Animais , Sistema Nervoso Autônomo/patologia , Feminino , Coração/inervação , Frequência Cardíaca , Masculino , Suínos
14.
Europace ; 17(12): 1840-7, 2015 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-26045502

RESUMO

AIMS: The Mason-Likar modified electrocardiogram (ML-ECG) can be interchanged with standard 12 lead ECG electrode positions (standard ECG) without affecting the diagnostic interpretation during sinus rhythm, but the morphological differences during ventricular arrhythmias have not been sufficiently evaluated. This study aimed to elucidate the morphological changes in the ML-ECG precordial leads. METHODS AND RESULTS: In 53 consecutive patients with premature ventricular contractions predicted to originate from the outflow tract (OT-PVCs), the arrhythmias were analysed by those two ECG methods. The OT-PVC origin sites, which were predicted by currently published criteria with the respective ECG methods prior to catheter ablation, were compared with the successful ablation sites. Compared with the standard-ECG, S-waves in the ML-ECG became shallower in leads V1-4 (P < 0.05 in lead V1; P < 0.001 in leads V2-4), and pseudo-R-waves in lead V1 appeared in seven patients. The precordial leads transition zone shifted counter-clockwise in 18 patients in the ML-ECG. In leads I and aVL, the negative deflection amplitudes of the ML-ECG were greater than those of the standard ECG (P < 0.001), and polarity reversals in lead I appeared in 18 patients. The R-wave amplitudes in all ML-ECG inferior leads were greater than those in the standard-ECG leads (all for P < 0.001). Those changes had an effect on the diagnostic indexes for the localization, and the specificity of the criteria for the ML-ECG was poorer than that for the standard-ECG. CONCLUSION: Great differences were found between those two ECG methods. Predicting OT-PVC origins by diagnostic criteria with the ML-ECG might result in a misdiagnosis and inefficient ablation.


Assuntos
Ablação por Cateter , Eletrocardiografia/métodos , Sistema de Condução Cardíaco/cirurgia , Frequência Cardíaca , Taquicardia Ventricular/diagnóstico , Taquicardia Ventricular/cirurgia , Complexos Ventriculares Prematuros/diagnóstico , Complexos Ventriculares Prematuros/cirurgia , Potenciais de Ação , Adulto , Idoso , Erros de Diagnóstico , Feminino , Sistema de Condução Cardíaco/fisiopatologia , Humanos , Masculino , Pessoa de Meia-Idade , Valor Preditivo dos Testes , Reprodutibilidade dos Testes , Taquicardia Ventricular/fisiopatologia , Fatores de Tempo , Resultado do Tratamento , Complexos Ventriculares Prematuros/fisiopatologia
15.
J Cardiovasc Electrophysiol ; 24(9): 975-83, 2013 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-23691953

RESUMO

INTRODUCTION: Atrial substrates with high-dominant frequency (DF) and complex fractionated atrial electrogram (CFAE) sites have sources maintaining atrial fibrillation (AF) and are potential AF ablation targets. This study aimed to evaluate an approach of circumferential pulmonary vein isolation (PVI) followed by a DF and CFAE site ablation. METHODS AND RESULTS: Fifty consecutive AF patients (23 paroxysmal, 9 persistent, and 18 longstanding persistent) underwent ablation, using NavX. When AF continued after circumferential PVI, high-DF sites of ≥ 8 Hz and then continuous left atrial (LA) CFAE sites defined by fractionated intervals (FI) of ≤50 milliseconds including the coronary sinus and right atrium were targeted. A total of 45.1% of high-DF and 48.1% of continuous CFAE sites significantly decreased after PVI (P < 0.001). The mean LA DF and FI significantly decreased and prolonged, respectively, after PVI (P < 0.001). Only 14.1% of all high-DF sites after PVI overlapped with continuous CFAE sites. AF terminated at high-DF sites in 11 (22%) patients and continuous CFAE sites in 1 (2%). AF could be induced in only 8% of patients after the procedure. The mean LA DF value before ablation was significantly lower in those without recurrence (P = 0.003). AF freedom on antiarrhythmic drugs was 96% and 59%, respectively, in the paroxysmal and nonparoxysmal AF patients (89% persistent and 44% longstanding persistent) after 1 procedure over a 12-month follow-up. CONCLUSIONS: A combined high-DF and continuous CFAE site ablation in all chambers after circumferential PVI may be effective in the paroxysmal and persistent AF patients.


Assuntos
Fibrilação Atrial/diagnóstico , Fibrilação Atrial/cirurgia , Ablação por Cateter/métodos , Técnicas Eletrofisiológicas Cardíacas/métodos , Veias Pulmonares/cirurgia , Idoso , Feminino , Seguimentos , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos
16.
Europace ; 15(3): 332-8, 2013 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-23194697

RESUMO

AIMS: Catheter ablation is a potentially curative treatment for atrial fibrillation (AF). However, complications such as ischaemic stroke are more frequent and more severe compared with ablation procedures for other arrhythmias. Irrigated-tip catheters have been reported to reduce the risk of stroke. The present study aimed to evaluate predictors of asymptomatic cerebral infarction (CI) after AF ablation using an irrigated-tip catheter. METHODS AND RESULTS: A total of 70 consecutive AF patients who underwent catheter ablation were subjected to brain magnetic resonance imaging (MRI) 1 day after the procedure. In 10 (14.3%) of 70 patients, MRI revealed acute CI, but neither symptoms nor abnormal neurological findings were present in these patients. In univariate analysis, a history of persistent AF, left atrial dimension, presence of spontaneous echo contrast (SEC), procedure duration prior to heparin injection, and electrical cardioversion during the procedure differed significantly between the two groups, those with and without CI (P = 0.02, 0.05, 0.01, 0.01, and 0.05, respectively). Multivariate logistic regression analysis identified SEC [odds ratio (OR), 9.39; 1.60-55.2; P = 0.01] and procedure duration prior to heparin injection (OR, 1.19; 1.04-1.36; P = 0.01) as predictive of acute asymptomatic CI after AF ablation. CONCLUSION: The presence of SEC and procedure duration prior to heparin injection are determinants of asymptomatic CI during AF ablation despite the use of an irrigated-tip catheter.


Assuntos
Fibrilação Atrial/cirurgia , Cateteres Cardíacos , Ablação por Cateter , Infarto Cerebral/etiologia , Irrigação Terapêutica , Administração Oral , Idoso , Anticoagulantes/administração & dosagem , Doenças Assintomáticas , Fibrilação Atrial/diagnóstico , Ablação por Cateter/efeitos adversos , Ablação por Cateter/instrumentação , Infarto Cerebral/diagnóstico , Infarto Cerebral/prevenção & controle , Distribuição de Qui-Quadrado , Imagem de Difusão por Ressonância Magnética , Desenho de Equipamento , Feminino , Heparina/administração & dosagem , Humanos , Injeções Intravenosas , Modelos Logísticos , Masculino , Pessoa de Meia-Idade , Análise Multivariada , Razão de Chances , Estudos Prospectivos , Medição de Risco , Fatores de Risco , Irrigação Terapêutica/efeitos adversos , Irrigação Terapêutica/instrumentação , Fatores de Tempo , Resultado do Tratamento , Varfarina/administração & dosagem
17.
Circ J ; 77(6): 1416-23, 2013.
Artigo em Inglês | MEDLINE | ID: mdl-23428717

RESUMO

BACKGROUND: The pre-procedural prediction of atrial fibrillation (AF) termination by catheter ablation in patients with persistent AF has not been evaluated fully. The aim of this study was to evaluate the pre-procedural predictors of persistent AF termination by ablation associated with the possibility of reverse remodeling of the left atrium (LA). METHODS AND RESULTS: Seventy consecutive patients (mean age, 62±8 years) with persistent or long-standing persistent AF underwent ablation. They were divided into 2 groups: those with AF terminated by ablation (n=14; group 1) and those with AF terminated by cardioversion after ablation (n=56; group 2). The left atrial appendage (LAA) contraction velocity determined on transesophageal echocardiography was significantly decreased in group 2 as compared to group 1 (P<0.001). Kaplan-Meier analysis showed that the group 1 patients had a higher AF-free survival rate than those in group 2 during 12±4.1 months of follow-up (P=0.048). The LA reverse remodeling ratio, given as the volume difference between before and 3 months after ablation in group 1, was significantly greater after ablation than that in group 2 (25.8±13% vs. 15.0±15%, P=0.015). Multivariate logistic regression analysis indicated that the LAA contraction velocity was an independent predictor of persistent AF termination by ablation (P=0.018). CONCLUSIONS: The LAA contraction velocity was the only non-invasive pre-procedural predictor of persistent AF termination by ablation, indicating the possibility of reverse remodeling of the LA.


Assuntos
Fibrilação Atrial/fisiopatologia , Fibrilação Atrial/terapia , Remodelamento Atrial , Ablação por Cateter , Idoso , Fibrilação Atrial/complicações , Fibrilação Atrial/diagnóstico por imagem , Ecocardiografia Transesofagiana , Feminino , Seguimentos , Humanos , Masculino , Pessoa de Meia-Idade , Contração Miocárdica
19.
BMJ Open ; 13(2): e068894, 2023 02 15.
Artigo em Inglês | MEDLINE | ID: mdl-36792334

RESUMO

INTRODUCTION: Data are lacking on the extent to which patients with non-valvular atrial fibrillation (AF) who are aged ≥80 years benefit from ablation treatment. The question pertains especially to patients' postablation quality of life (QoL) and long-term clinical outcomes. METHODS AND ANALYSIS: We are initiating a prospective, registry-based, multicentre observational study that will include patients aged ≥80 years with non-valvular AF who choose to undergo treatment by catheter ablation and, for comparison, such patients who do not choose to undergo ablation (either according to their physician's advice or their own preference). Study subjects are to be enrolled from 52 participant hospitals and three clinics located throughout Japan from 1 June 2022 to 31 December 2023, and each will be followed up for 1 year. The planned sample size is 660, comprising 220 ablation group patients and 440 non-ablation group patients. The primary endpoint will be the composite incidence of stroke/transient ischaemic attack (TIA) or systemic embolism (SE), another cardiovascular event, major bleeding and/or death from any cause. Other clinical events such as postablation AF recurrence, a fall or bone fracture will be recorded. We will collect standard clinical background information plus each patient's Clinical Frailty Scale score, AF-related symptoms, QoL (Five-Level Version of EQ-5D) scores, Mini-Mental State Examination (optional) score and laboratory test results, including measures of nutritional status, on entry into the study and 1 year later, and serial changes in symptoms and QoL will also be secondary endpoints. Propensity score matching will be performed to account for covariates that could affect study results. ETHICS AND DISSEMINATION: The study conforms to the Declaration of Helsinki and the Ethical Guidelines for Clinical Studies issued by the Ministry of Health, Labour and Welfare, Japan. Results of the study will be published in one or more peer-reviewed journals. TRIAL REGISTRATION NUMBER: UMIN000047023.


Assuntos
Fibrilação Atrial , Ablação por Cateter , Acidente Vascular Cerebral , Idoso , Humanos , Fibrilação Atrial/epidemiologia , Fibrilação Atrial/cirurgia , Fibrilação Atrial/complicações , Qualidade de Vida , Estudos Prospectivos , Expectativa de Vida Saudável , Fatores de Risco , Acidente Vascular Cerebral/etiologia , Acidente Vascular Cerebral/complicações , Sistema de Registros , Ablação por Cateter/efeitos adversos , Ablação por Cateter/métodos , Resultado do Tratamento
20.
Circ J ; 76(10): 2337-42, 2012.
Artigo em Inglês | MEDLINE | ID: mdl-22785434

RESUMO

BACKGROUND: Periprocedural anticoagulation using uninterrupted warfarin could reduce the risk of thromboembolic complications of atrial fibrillation (AF) ablation. Few studies, however, have evaluated the efficacy and safety of periprocedural dabigatran in AF ablation. METHODS AND RESULTS: A total of 211 consecutive patients who underwent AF ablation, including 110 patients who received 110mg dabigatran twice daily (group D) and 101 patients who received dose-adjusted warfarin (international normalized ratio, 2.0-3.0; group W), were evaluated. Dabigatran was discontinued on the morning of the procedure, and resumed on the next morning. Warfarin was continued throughout the procedure. During the procedure, heparin infusion was maintained to achieve an activated clotting time of >300s. Postprocedural cerebral magnetic resonance imaging (MRI) was performed in 60 patients (group D, n=31; group W, n=29). No periprocedural deaths or symptomatic thromboembolic complications were observed in either group. MRI indicated a silent cerebral infarction in 1 patient in each group. Five patients in group D and 11 in group W had minor bleeding (P=0.12). Cardiac tamponade occurred in 2 patients in group W, but in none in group D. Total bleeding complications occurred less frequently in group D (4.5%) than in group W (12.9%; P<0.05). CONCLUSIONS: Dabigatran at a dose of 110mg twice daily was safe for AF ablation in patients with a relatively low risk of thromboemboli, suggesting that it may become an alternative to warfarin in those patients.


Assuntos
Antitrombinas/administração & dosagem , Benzimidazóis/administração & dosagem , Ablação por Cateter , Assistência Perioperatória/métodos , Tromboembolia/prevenção & controle , beta-Alanina/análogos & derivados , Idoso , Anticoagulantes/administração & dosagem , Anticoagulantes/efeitos adversos , Antitrombinas/efeitos adversos , Fibrilação Atrial , Benzimidazóis/efeitos adversos , Dabigatrana , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Tromboembolia/etiologia , Varfarina/administração & dosagem , Varfarina/efeitos adversos , beta-Alanina/administração & dosagem , beta-Alanina/efeitos adversos