1.
PLoS One ; 17(6): e0269542, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-35666737

RESUMO

Although scatter correction improves SPECT image contrast and thus image quality, the effects of quantitation accuracy under various conditions remain unclear. The present study aimed to empirically define the conditions for the optimal scatter correction of quantitative bone SPECT/CT images. Scatter correction was performed by applying dual and triple energy windows (DEW and TEW) with different sub-energy window widths, and effective scatter source estimation (ESSE) to CT-based scatter correction. Scattered radiation was corrected on images acquired using a triple line source (TLSP) phantom and an uniform cylinder phantom. The TLSP consisted of a line source containing 74.0 MBq of 99mTc in the middle, and a background component containing air, water or a K2HPO4 solution with a density equivalent to that of bone. The sum of all pixels in air, water and the K2HPO4 solution was measured on SPECT images. Scatter fraction (SF) and normalized mean square error (NMSE) based on counts from the air background as a reference were then calculated to assess quantitative errors due to scatter correction. The uniform cylinder phantom contained the same K2HPO4 solution and 222.0 MBq of 99mTc. The coefficient of variation (CV) was calculated from the count profile of this phantom to assess the uniformity of SPECT images across scatter correction under various conditions. Both SF and NMSE in SPECT images of phantoms containing water in the background were lower at a TEW sub-window of 3% (TEW3%), than in other scatter corrections, whereas those in K2HPO4 were lower at a DEW sub-window of 20% (DEW20%). Larger DEW and smaller TEW sub-energy windows allowed more effective correction. The CV of the uniform cylinder phantom, DEW20%, was inferior to all other tested scatter corrections. The quantitative accuracy of bone SPECT images substantially differed according to the method of scatter correction. The optimal scatter correction for quantitative bone SPECT was DEW20% (k = 1), but at the cost of slightly decreased image uniformity.


Assuntos
Tomografia Computadorizada com Tomografia Computadorizada de Emissão de Fóton Único , Tomografia Computadorizada de Emissão de Fóton Único , Imagens de Fantasmas , Espalhamento de Radiação , Tomografia Computadorizada de Emissão de Fóton Único/métodos , Água
2.
Ann Nucl Med ; 34(10): 762-771, 2020 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-32623569

RESUMO

OBJECTIVE: Many advances in PET/CT technology can potentially improve image quality and the ability to detect small lesions. A new digital TOF-PET/CT scanner based on silicon photomultipliers (SiPM) integrated with a Bayesian penalized likelihood (BPL) PET reconstruction algorithm (Q.Clear; GE Healthcare) has been introduced into clinical practice. The present study aimed to quantify the ability of a digital TOF-PET/CT scanner combined with BPL reconstruction to detect small lesions, and to determine the optimal penalization factor (ß) in BPL to accurately detect such lesions. METHODS: All PET data were acquired from a NEMA body phantom using a Discovery MI (DMI) PET/CT system (GE Healthcare). The phantom included six spheres with diameters of 4, 5, 6, 8, 10, and 13 mm, and contained a background activity level of 5.3 kBq/mL, with target-to-background ratios (TBR) of 4:1 and 8:1. Images were reconstructed using a baseline OSEM algorithm, with OSEM + PSF, OSEM + TOF, OSEM + PSF + TOF, and BPL + PSF + TOF (ß: 50-400). The matrix size was 192 × 192 and 384 × 384. Data acquired in 100-min list mode were re-binned into acquisition times ranging from 2 to 100 min. The quantitative accuracy and detectability of small hot spheres were evaluated by physical assessment of a recovery coefficient (RC) and a detectability index (DI), as well as visual assessment of PET images at each acquisition time. RESULTS: The RC and DI of sub-centimeter spheres were improved, because the digital TOF-PET/CT scanner has a larger TOF performance gain due to better timing resolution. The RC and DI were higher with BPL in sub-centimeter spheres, than with other OSEM-based types of reconstruction. The BPL for an 8-mm sphere overestimated uptake due to edge artifact overshoot induced by PSF modeling. The variability of RC and DI for acquisition times and TBR differed considerably according to ß values. The RC for ~ 8-mm spheres were > 1 at ß values between 50 and 100, but were close to 1 at ß value of 200. The visual scores for ß = 200 in BPL were maximal, whereas those for spheres that were ≥ 6 mm exceeded the criterion of 3. CONCLUSION: The BPL in the digital TOF-PET/CT scanner improved the quantitation and detectability of sub-centimeter spheres compared with OSEM-based reconstruction. Optimization of the ß value in BPL might allow the detection of lesions ≤ 6 mm, although detectability depended on the TBR of lesions. A ß value of 200 seemed optimal for detecting sub-centimeter lesions.


Assuntos
Algoritmos , Processamento de Imagem Assistida por Computador/métodos , Tomografia por Emissão de Pósitrons combinada à Tomografia Computadorizada , Teorema de Bayes , Funções Verossimilhança , Imagens de Fantasmas , Silício