Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 179
Filtrar
1.
J Appl Clin Med Phys ; 25(7): e14383, 2024 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-38801204

RESUMO

OBJECTIVE: To assess the impact of scatter radiation on quantitative performance of first and second-generation dual-layer spectral computed tomography (DLCT) systems. METHOD: A phantom with two iodine inserts (1 and 2 mg/mL) configured to intentionally introduce high scattering conditions was scanned with a first- and second-generation DLCT. Collimation widths (maximum of 4 cm for first generation and 8 cm for second generation) and radiation dose levels were varied. To evaluate the performance of both systems, the mean CT numbers of virtual monoenergetic images (MonoEs) at different energies were calculated and compared to expected values. MonoEs at 50  versus 150 keV were plotted to assess material characterization of both DLCTs. Additionally, iodine concentrations were determined, plotted, and compared against expected values. For each experimental scenario, absolute errors were reported. RESULTS: An experimental setup, including a phantom design, was successfully implemented to simulate high scatter radiation imaging conditions. Both CT scanners illustrated high spectral accuracy for small collimation widths (1 and 2 cm). With increased collimation (4 cm), the second-generation DLCT outperformed the earlier DLCT system. Further, the spectral performance of the second-generation DLCT at an 8 cm collimation width was comparable to a 4 cm collimation on the first-generation DLCT. A comparison of the absolute errors between both systems at lower energy MonoEs illustrates that, for the same acquisition parameters, the second-generation DLCT generated results with decreased errors. Similarly, the maximum error in iodine quantification was less with second-generation DLCT (0.45  and 0.33 mg/mL for the first and second-generation DLCT, respectively). CONCLUSION: The implementation of a two-dimensional anti-scatter grid in the second-generation DLCT improves the spectral quantification performance. In the clinical routine, this improvement may enable additional clinical benefits, for example, in lung imaging.


Assuntos
Processamento de Imagem Assistida por Computador , Imagens de Fantasmas , Espalhamento de Radiação , Tomografia Computadorizada por Raios X , Humanos , Tomografia Computadorizada por Raios X/métodos , Processamento de Imagem Assistida por Computador/métodos , Doses de Radiação , Interpretação de Imagem Radiográfica Assistida por Computador/métodos
2.
J Appl Clin Med Phys ; 25(4): e14300, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-38386967

RESUMO

PURPOSE: The aim of this study was to characterize a second-generation wide-detector dual-layer spectral computed tomography (CT) system for material quantification accuracy, acquisition parameter and patient size dependencies, and tissue characterization capabilities. METHODS: A phantom with multiple tissue-mimicking and material-specific inserts was scanned with a dual-layer spectral detector CT using different tube voltages, collimation widths, radiation dose levels, and size configurations. Accuracy of iodine density maps and virtual monoenergetic images (MonoE) were investigated. Additionally, differences between conventional and MonoE 70 keV images were calculated to evaluate acquisition parameter and patient size dependencies. To demonstrate material quantification and differentiation, liver-mimicking inserts with adipose and iron were analyzed with a two-base decomposition utilizing MonoE 50 and 150 keV, and root mean square error (RMSE) for adipose and iron content was reported. RESULTS: Measured inserts exhibited quantitative accuracy across a wide range of MonoE levels. MonoE 70 keV images demonstrated reduced dependence compared to conventional images for phantom size (1 vs. 27 HU) and acquisition parameters, particularly tube voltage (4 vs. 37 HU). Iodine density quantification was successful with errors ranging from -0.58 to 0.44 mg/mL. Similarly, inserts with different amounts of adipose and iron were differentiated, and the small deviation in values within inserts corresponded to a RMSE of 3.49 ± 1.76% and 1.67 ± 0.84 mg/mL for adipose and iron content, respectively. CONCLUSION: The second-generation dual-layer CT enables acquisition of quantitatively accurate spectral data without compromises from differences in patient size and acquisition parameters.


Assuntos
Iodo , Tomografia Computadorizada por Raios X , Humanos , Razão Sinal-Ruído , Tomografia Computadorizada por Raios X/métodos , Imagens de Fantasmas , Obesidade , Ferro
3.
Eur Radiol ; 32(12): 8579-8587, 2022 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-35708838

RESUMO

OBJECTIVE: Evaluation of image characteristics at ultra-low radiation dose levels of a first-generation dual-source photon-counting computed tomography (PCCT) compared to a dual-source dual-energy CT (DECT) scanner. METHODS: A multi-energy CT phantom was imaged with and without an extension ring on both scanners over a range of radiation dose levels (CTDIvol 0.4-15.0 mGy). Scans were performed in different modes of acquisition for PCCT with 120 kVp and DECT with 70/Sn150 kVp and 100/Sn150 kVp. Various tissue inserts were used to characterize the precision and repeatability of Hounsfield units (HUs) on virtual mono-energetic images between 40 and 190 keV. Image noise was additionally investigated at an ultra-low radiation dose to illustrate PCCT's ability to remove electronic background noise. RESULTS: Our results demonstrate the high precision of HU measurements for a wide range of inserts and radiation exposure levels with PCCT. We report high performance for both scanners across a wide range of radiation exposure levels, with PCCT outperforming at low exposures compared to DECT. PCCT scans at the lowest radiation exposures illustrate significant reduction in electronic background noise, with a mean percent reduction of 74% (p value ~ 10-8) compared to DECT 70/Sn150 kVp and 60% (p value ~ 10-6) compared to DECT 100/Sn150 kVp. CONCLUSIONS: This paper reports the first experiences with a clinical dual-source PCCT. PCCT provides reliable HUs without disruption from electronic background noise for a wide range of dose values. Diagnostic benefits are not only for quantification at an ultra-low dose but also for imaging of obese patients. KEY POINTS: PCCT scanners provide precise and reliable Hounsfield units at ultra-low dose levels. The influence of electronic background noise can be removed at ultra-low-dose acquisitions with PCCT. Both spectral platforms have high performance along a wide range of radiation exposure levels, with PCCT outperforming at low radiation exposures.


Assuntos
Tomografia Computadorizada por Raios X , Humanos , Tomografia Computadorizada por Raios X/métodos , Doses de Radiação , Imagens de Fantasmas
4.
Nanotechnology ; 33(49)2022 Sep 19.
Artigo em Inglês | MEDLINE | ID: mdl-35994941

RESUMO

An essential prerequisite for successful solution blow spinning (SBS) is the presence of effective molecular entanglements of polymers in the solution. However, the fabrication of biopolymer fibers is not as straightforward as synthetic polymers. Particularly for biopolymers such as pectin, molecular entanglements are essential but insufficient for successful spinning through the SBS production method. Such a challenge is due to the biopolymer's complex nature. However, incorporating an easily spinnable polymer precursor, such as polyacrylonitrile (PAN), to pectin effectively enabled the production of fibers from the SBS process. In this process, PAN-assisted pectin nanofibers are produced with average diameters ranging from 410.75 ± 3.73 to 477.09 ± 6.60 nm using a feed flow rate of 5 ml h-1, air pressure of 3 bars, syringe tip to collector distance at 30 cm, and spinning time of 10 min. PAN in DMSO solvent at different volume ratios (i.e. 35%-55% v/v) was critical in assisting pectin to produce nanofibers. The addition of a high molecular weight polymer, PAN, to pectin also improved the viscoelasticity of the solution, eventually contributing to its successful SBS process. Furthermore, the composite SBS-spun fibers obtained suggest that its formation is concentration-dependent.


Assuntos
Mangifera , Nanofibras , Biopolímeros , Dimetil Sulfóxido , Pectinas , Polímeros , Solventes
5.
Eur Radiol ; 31(4): 2590-2600, 2021 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-32945965

RESUMO

OBJECTIVES: To investigate potential radiation dose reduction for multi-detector computed tomography (MDCT) exams of the spine by using sparse sampling and virtually lowered tube currents combined with statistical iterative reconstruction (SIR). METHODS: MDCT data of 26 patients (68.9 ± 11.7 years, 42.3% males) were retrospectively simulated as if the scans were acquired at 50%, 10%, 5%, and 3% of the original X-ray tube current or number of projections, using SIR for image reconstructions. Two readers performed qualitative image evaluation considering overall image quality, artifacts, and contrast and determined the number and type of degenerative changes. Scoring was compared between readers and virtual low-dose and sparse-sampled MDCT, respectively. RESULTS: Image quality and contrast decreased with virtual lowering of tube current and sparse sampling, but all degenerative changes were correctly detected in MDCT with 50% of tube current as well as MDCT with 50% of projections. Sparse-sampled MDCT with only 10% of initial projections still enabled correct identification of all degenerative changes, in contrast to MDCT with virtual tube current reduction by 90% where non-calcified disc herniations were frequently missed (R1: 23.1%, R2: 21.2% non-diagnosed herniations). The average volumetric CT dose index (CTDIvol) was 1.4 mGy for MDCT with 10% of initial projections, compared with 13.8 mGy for standard-dose imaging. CONCLUSIONS: MDCT with 50% of original tube current or projections using SIR still allowed for accurate diagnosis of degenerative changes. Sparse sampling may be more promising for further radiation dose reductions since no degenerative changes were missed with 10% of initial projections. KEY POINTS: • Most common degenerative changes of the spine can be diagnosed in multi-detector CT with 50% of tube current or number of projections. • Sparse-sampled multi-detector CT with only 10% of initial projections still enables correct identification of degenerative changes, in contrast to imaging with 10% of original tube current. • Sparse sampling may be a promising option for distinct lowering of radiation dose, reducing the CTDIvol from 13.8 to 1.4 mGy in the study cohort.


Assuntos
Tomografia Computadorizada Multidetectores , Coluna Vertebral , Artefatos , Feminino , Humanos , Masculino , Doses de Radiação , Interpretação de Imagem Radiográfica Assistida por Computador , Estudos Retrospectivos
6.
Eur Radiol ; 31(5): 3147-3155, 2021 May.
Artigo em Inglês | MEDLINE | ID: mdl-33052464

RESUMO

OBJECTIVES: Osteoporosis remains under-diagnosed, which may be improved by opportunistic bone mineral density (BMD) measurements on CT. However, correcting for the influence of intravenous iodine-based contrast agent is challenging. The purpose of this study was to assess the diagnostic accuracy of iodine-corrected vertebral BMD measurements derived from non-dedicated contrast-enhanced phantomless dual-layer spectral CT (DLCT) examinations. METHODS: Vertebral volumetric DLCT-BMD was measured in native, arterial, and portal-venous scans of 132 patients (63 ± 16 years; 32% women) using virtual monoenergetic images (50 and 200 keV). For comparison, conventional BMD was determined using an asynchronous QCT calibration. Additionally, iodine densities were measured in the abdominal aorta (AA), inferior vena cava, and vena portae (VP) on each CT phase to adjust for iodine-related measurement errors in multivariable linear regressions and a generalized estimated equation, and conversion equations were calculated. RESULTS: BMD values derived from contrast-enhanced phases using conversion equations adjusted for individual vessel iodine concentrations of VP and/or AA showed a high agreement with those from non-enhanced scans in Bland-Altman plots. Mean absolute errors (MAE) of DLCT-BMD were 3.57 mg/ml for the arterial (R2 = 0.989) and 3.69 mg/ml for the portal-venous phase (R2 = 0.987) (conventional BMD: 4.70 [R2 = 0.983] and 5.15 mg/ml [R2 = 0.981]). In the phase-independent analysis, MAE was 4.49 mg/ml for DLCT (R2 = 0.989) (conventional BMD: 4.82 mg/ml [R2 = 0.981]). CONCLUSIONS: Converted BMD derived from contrast-enhanced DLCT examinations and adjusted for individual vessel iodine concentrations showed a high agreement with non-enhanced DLCT-BMD, suggesting that opportunistic BMD measurements are feasible even in non-dedicated contrast-enhanced DLCT examinations. KEY POINTS: • Accurate BMD values can be converted from contrast-enhanced DLCT scans, independent from the used scan phase. • DLCT-BMD measurements from contrast-enhanced scans should be adjusted with iodine concentrations of portal vein and/or abdominal aorta, which significantly improves the goodness-of-fit of conversion models.


Assuntos
Densidade Óssea , Osteoporose , Feminino , Humanos , Masculino , Programas de Rastreamento , Osteoporose/diagnóstico por imagem , Coluna Vertebral/diagnóstico por imagem , Tomografia Computadorizada por Raios X
7.
AJR Am J Roentgenol ; 216(5): 1308-1317, 2021 05.
Artigo em Inglês | MEDLINE | ID: mdl-33703925

RESUMO

OBJECTIVE. The purpose of our study was to evaluate simulated sparse-sampled MDCT combined with statistical iterative reconstruction (SIR) for low-dose imaging of patients with spinal instrumentation. MATERIALS AND METHODS. Thirty-eight patients with implanted hardware after spinal instrumentation (24 patients with short- or long-term instrumentation-related complications [i.e., adjacent segment disease, screw loosening or implant failure, or postoperative hematoma or seroma] and 14 control subjects with no complications) underwent MDCT. Scans were simulated as if they were performed with 50% (P50), 25% (P25), 10% (P10), and 5% (P5) of the projections of the original acquisition using an in-house-developed SIR algorithm for advanced image reconstructions. Two readers performed qualitative image evaluations of overall image quality and artifacts, image contrast, inspection of the spinal canal, and diagnostic confidence (1 = high, 2 = medium, and 3 = low confidence). RESULTS. Although overall image quality decreased and artifacts increased with reductions in the number of projections, all complications were detected by both readers when 100% of the projections of the original acquisition (P100), P50, and P25 imaging data were used. For P25 data, diagnostic confidence was still high (mean score ± SD: reader 1, 1.2 ± 0.4; reader 2, 1.3 ± 0.5), and interreader agreement was substantial to almost perfect (weighted Cohen κ = 0.787-0.855). The mean volumetric CT dose index was 3.2 mGy for P25 data in comparison with 12.6 mGy for the original acquisition (P100 data). CONCLUSION. The use of sparse sampling and SIR for low-dose MDCT in patients with spinal instrumentation facilitated considerable reductions in radiation exposure. The use of P25 data with SIR resulted in no missed complications related to spinal instrumentation and allowed high diagnostic confidence, so using only 25% of the projections is probably enough for accurate and confident diagnostic detection of major instrumentation-related complications.


Assuntos
Artefatos , Fixadores Internos , Tomografia Computadorizada Multidetectores/métodos , Complicações Pós-Operatórias/diagnóstico por imagem , Doses de Radiação , Interpretação de Imagem Radiográfica Assistida por Computador/métodos , Adulto , Idoso , Idoso de 80 Anos ou mais , Feminino , Humanos , Masculino , Metais , Pessoa de Meia-Idade , Estudos Retrospectivos , Coluna Vertebral/diagnóstico por imagem
8.
J Appl Clin Med Phys ; 22(3): 16-26, 2021 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-33426801

RESUMO

BACKGROUND: Spectral computed tomography (spectral CT) provides access to clinically relevant measures of endogenous and exogenous materials in patients. For pediatric patients, current spectral CT applications include lesion characterization, quantitative vascular imaging, assessments of tumor response to treatment, and more. OBJECTIVE: The aim of this study is a comprehensive investigation of the accuracy and stability of spectral quantifications from a spectral detector-based CT system with respect to different patient sizes and radiation dose levels relevant for the pediatric population. MATERIALS AND METHODS: A spectral CT phantom with tissue-mimicking materials and iodine concentrations relevant for pediatric imaging was scanned on a spectral detector CT system using a standard pediatric abdominal protocol at 100%, 67%, 33% and 10% of the nominal radiation dose level. Different pediatric patient sizes were simulated using supplemental 3D-printed extension rings. Virtual mono-energetic, iodine density, effective atomic number, and electron density results were analyzed for stability with respect to radiation dose and patient size. RESULTS: Compared to conventional CT imaging, a pronounced improvement in the stability of attenuation measurements across patient size was observed when using virtual mono-energetic images. Iodine densities were within 0.1 mg/ml, effective atomic numbers were within 0.26 atomic numbers and electron density quantifications were within ±1.0% of their respective nominal values. Relative to the nominal dose clinical protocol, differences in attenuation of all tissue-mimicking materials were maintained below 1.6 HU for a 33% dose reduction, below 2.7 HU for a 67% dose reduction and below 3.7 HU for a 90% dose reduction, for all virtual mono-energetic energies equal to or greater than 50 keV. Iodine, and effective atomic number quantifications were stable to within 0.1 mg/ml and 0.06 atomic numbers, respectively, across all measured dose levels. CONCLUSION: Spectral CT provides accurate and stable material quantification with respect to radiation dose reduction (up to 90%) and differing pediatric patient size. The observed consistency is an important step towards quantitative pediatric imaging at low radiation exposure levels.


Assuntos
Iodo , Tomografia Computadorizada por Raios X , Criança , Humanos , Imagens de Fantasmas , Doses de Radiação
9.
Nanotechnology ; 31(34): 345602, 2020 Aug 21.
Artigo em Inglês | MEDLINE | ID: mdl-32375136

RESUMO

Cellulose-based nanofiber membrane fabrication remains a global challenge, especially the use of alternative and sustainable sources of cellulosic materials. Herein, an easy and highly scalable cellulose-based nanofiber membrane was successfully fabricated using a solution blow spinning (SBS) method. Such membrane fabrication was carried out with the assistance of an easy-to-spin precursor polymer (i.e. polyacrylonitrile (PAN)). Through this strategy, cellulose acetate (CA) was successfully spun into a ready-to-use membrane. The formation of CA with the PAN nanofiber is concentration-dependent and requires high air pressure to effectively overcome the composite precursor's surface tension and eventually produce nanofibers. Favourable CA concentration in PAN (i.e. 50%-65% v/v CAN/PAN) is important to the formation of sufficient molecular entanglement with PAN in solution. Upon fulfilling the optimized CA concentration, high air pressure (i.e. ≥3 bars) is used to produce jet-like polymeric fibers of PAN dragging off CA, forming numerous nanofibers which are then collected into a substrate forming a membrane. Characterizations of the CA/PAN composite nanofiber were carried out using scanning electron microscopy, Fourier transform infrared, thermogravimetric analysis and differential scanning calorimetry (DSC). Such unique composite nanofiber membranes have potential as filters and adsorbent membranes for air and water/wastewater applications, as well as for biorefinery applications.

10.
Eur Radiol ; 29(5): 2185-2195, 2019 May.
Artigo em Inglês | MEDLINE | ID: mdl-30377791

RESUMO

The first CT scanners in the early 1970s already used iterative reconstruction algorithms; however, lack of computational power prevented their clinical use. In fact, it took until 2009 for the first iterative reconstruction algorithms to come commercially available and replace conventional filtered back projection. Since then, this technique has caused a true hype in the field of radiology. Within a few years, all major CT vendors introduced iterative reconstruction algorithms for clinical routine, which evolved rapidly into increasingly advanced reconstruction algorithms. The complexity of algorithms ranges from hybrid-, model-based to fully iterative algorithms. As a result, the number of scientific publications on this topic has skyrocketed over the last decade. But what exactly has this technology brought us so far? And what can we expect from future hardware as well as software developments, such as photon-counting CT and artificial intelligence? This paper will try answer those questions by taking a concise look at the overall evolution of CT image reconstruction and its clinical implementations. Subsequently, we will give a prospect towards future developments in this domain. KEY POINTS: • Advanced CT reconstruction methods are indispensable in the current clinical setting. • IR is essential for photon-counting CT, phase-contrast CT, and dark-field CT. • Artificial intelligence will potentially further increase the performance of reconstruction methods.


Assuntos
Algoritmos , Inteligência Artificial , Interpretação de Imagem Radiográfica Assistida por Computador/métodos , Tomografia Computadorizada por Raios X/métodos , Humanos , Doses de Radiação
11.
Eur Radiol ; 29(7): 3606-3616, 2019 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-30903337

RESUMO

PURPOSE: To systematically evaluate the effects of virtual tube current reduction and sparse sampling on image quality and vertebral fracture diagnostics in multi-detector computed tomography (MDCT). MATERIALS AND METHODS: In routine MDCT scans of 35 patients (80.0% females, 70.6 ± 14.2 years, 65.7% showing vertebral fractures), reduced radiation doses were retrospectively simulated by virtually lowering tube currents and applying sparse sampling, considering 50%, 25%, and 10% of the original tube current and projections, respectively. Two readers evaluated items of image quality and presence of vertebral fractures. Readout between the evaluations in the original images and those with virtually lowered tube currents or sparse sampling were compared. RESULTS: A significant difference was revealed between the evaluations of image quality between MDCT with virtually lowered tube current and sparse-sampled MDCT (p < 0.001). Sparse-sampled data with only 25% of original projections still showed good to very good overall image quality and contrast of vertebrae as well as minimal artifacts. There were no missed fractures in sparse-sampled MDCT with 50% reduction of projections, and clinically acceptable determination of fracture age was possible in MDCT with 75% reduction of projections, in contrast to MDCT with 50% or 75% virtual tube current reduction, respectively. CONCLUSION: Sparse-sampled MDCT provides adequate image quality and diagnostic accuracy for vertebral fracture detection with 50% of original projections in contrast to corresponding MDCT with lowered tube current. Thus, sparse sampling is a promising technique for dose reductions in MDCT that could be introduced in future generations of scanners. KEY POINTS: • MDCT with a reduction of projection numbers of 50% still showed high diagnostic accuracy without any missed vertebral fractures. • Clinically acceptable determination of vertebral fracture age was possible in MDCT with a reduction of projection numbers of 75%. • With sparse sampling, higher reductions in radiation exposure can be achieved without compromised image or diagnostic quality in routine MDCT of the spine as compared to MDCT with reduced tube currents.


Assuntos
Artefatos , Vértebras Cervicais/lesões , Tomografia Computadorizada Multidetectores/métodos , Fraturas da Coluna Vertebral/diagnóstico , Vértebras Torácicas/lesões , Adulto , Idoso , Idoso de 80 Anos ou mais , Vértebras Cervicais/diagnóstico por imagem , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Retrospectivos , Vértebras Torácicas/diagnóstico por imagem
12.
Eur Radiol ; 29(11): 5950-5960, 2019 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-31073861

RESUMO

OBJECTIVES: Evaluation of sparse sampling computed tomography (SpSCT) regarding subjective and objective image criteria for the detection of pulmonary embolism (PE) at different simulated dose levels. METHODS: Computed tomography pulmonary angiography (CTPA) scans of 20 clinical patients were used to obtain simulated low-dose scans with 100%-50%-25%-12.5%-6.3%-3.1% of the clinical dose, resulting in a total of six dose levels (DL). From these full sampling (FS) data, every second (2-SpSCT) or fourth (4-SpSCT) projection was used to obtain simulated sparse sampling scans. Each image set was evaluated by four blinded radiologists regarding subjective image criteria (artifacts, image quality) and diagnostic performance (confidence, sensitivity, specificity, accuracy, and area under the curve). Additionally, the contrast-to-noise ratio (CNR) was evaluated for objective image quality. RESULTS: Sensitivity was 100% with 2-SpSCT and 4-SpSCT at the 25% DL and the 12.5% DL for all localizations of PE (one subgroup 98.5%). With FS, the sensitivity decreased to 90% at the 12.5% DL. 2-SpSCT and 4-SpSCT showed higher values for sensitivity, specificity, accuracy, and the area under the curve at all DL compared with FS. Subjective image quality was significantly higher for 4-SpSCT compared with FS at each dose level (p < 0.01, paired t test). Only with 4-SpSCT, all examinations were rated as showing diagnostic image quality at the 12.5% DL. CONCLUSIONS: Via SpSCT, a dose reduction down to a 12.5% dose level (corresponding to a mean effective dose of 0.38 mSv in the current study) for CTPA is possible while maintaining high image quality and full diagnostic confidence. KEY POINTS: • With sparse sampling CT, radiation dose could be significantly reduced in clinical routine. • Sparse sampling CT is a novel hardware solution with which less projection images are acquired. • In the current study, a dose reduction of 87.5% (corresponding to a mean effective dose of 0.38 mSv) for CTPA could be achieved while maintaining excellent diagnostic performance.


Assuntos
Angiografia por Tomografia Computadorizada/métodos , Embolia Pulmonar/diagnóstico por imagem , Análise de Variância , Artefatos , Estudos de Viabilidade , Humanos , Pulmão/diagnóstico por imagem , Segurança do Paciente , Doses de Radiação , Sensibilidade e Especificidade
13.
Eur Radiol ; 29(1): 13-21, 2019 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-29948069

RESUMO

OBJECTIVES: To evaluate the diagnostic value of MR-derived CT-like images and simulated radiographs compared with conventional radiographs in patients with benign and malignant bone tumors. METHODS: In 32 patients with a benign or malignant bone lesion (mean age 33.9 ± 18.5 years, 17 females), 3-T MR imaging was performed including a 3D T1-weighted gradient echo sequence as the basis for the CT-like images. From these, intensity-inverted MR image volumes were converted into 2D images via a forward projection to obtain simulated radiographs. Two radiologists assessed these images as well as conventional radiographs for the type of periosteal reaction, matrix mineralization and destruction pattern. Agreement between the modalities was calculated using Cohen's κ. RESULTS: The agreement between conventional radiographs and MR-derived CT-like images in combination with simulated radiographs was substantial (periosteal reaction, κ = 0.67; destruction pattern, κ = 0.75), and the sensitivity of both modalities for the final diagnosis of the lesion (aggressive vs. nonaggressive) was high (MR-derived CT-like images, 86.2% vs. conventional radiographs, 90.0%). Additional information on soft tissue extension (MR-derived CT-like images, 21.9% vs. conventional radiographs, 12.5%; p = 0.009) and lobulation (9.4% vs. 0%; p < 0.001) was significantly more often found on MR-derived CT-like images compared with conventional radiographs. CONCLUSIONS: The assessment of the destruction patterns, periosteal reaction and distinction between aggressive and nonaggressive tumors was feasible using MR-derived CT-like images and simulated radiographs and is comparable to that of conventional radiographs. Moreover, MR-derived CT-like images provided additional information on soft tissue extension and tumor architecture. KEY POINTS: • CT-like images and simulated radiographs can be generated from 3D MRI. • Evaluation of bone tumors is feasible with MR-derived images. • CT-like images and simulated radiographs provide additional information on bone tumors.


Assuntos
Doenças Ósseas/diagnóstico , Neoplasias Ósseas/diagnóstico , Osso e Ossos/diagnóstico por imagem , Simulação por Computador , Imageamento por Ressonância Magnética/métodos , Tomografia Computadorizada por Raios X/métodos , Adulto , Diagnóstico Diferencial , Feminino , Humanos , Masculino , Curva ROC
14.
Eur Radiol ; 29(9): 4624-4634, 2019 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-30758656

RESUMO

OBJECTIVES: To develop and evaluate a method for areal bone mineral density (aBMD) measurement based on dual-layer spectral CT scout scans. METHODS: A post-processing algorithm using a pair of 2D virtual mono-energetic scout images (VMSIs) was established in order to semi-automatically compute the aBMD at the spine similarly to DXA, using manual soft tissue segmentation, semi-automatic segmentation for the vertebrae, and automatic segmentation for the background. The method was assessed based on repetitive measurements of the standardized European Spine Phantom (ESP) using the standard scout scan tube current (30 mA) and other tube currents (10 to 200 mA), as well as using fat-equivalent extension rings simulating different patient habitus, and was compared to dual-energy X-ray absorptiometry (DXA). Moreover, the feasibility of the method was assessed in vivo in female patients. RESULTS: Derived from standard scout scans, aBMD values measured with the proposed method significantly correlated with DXA measurements (r = 0.9925, p < 0.001), and mean accuracy (DXA, 4.12%; scout, 1.60%) and precision (DXA, 2.64%; scout, 2.03%) were comparable between the two methods. Moreover, aBMD values assessed at different tube currents did not differ significantly (p ≥ 0.20 for all), suggesting that the presented method could be applied to scout scans with different settings. Finally, data derived from sample patients were concordant with BMD values from a reference age-matched population. CONCLUSIONS: Based on dual-layer spectral scout scans, aBMD measurements were fast and reliable and significantly correlated with the according DXA measurements in phantoms. Considering the number of CT acquisitions performed worldwide, this method could allow truly opportunistic osteoporosis screening. KEY POINTS: • 2D scout scans (localizer radiographs) from a dual-layer spectral CT scanner, which are mandatory parts of a CT examination, can be used to automatically determine areal bone mineral density (aBMD) at the spine. • The presented method allowed fast (< 25 s/patient), semi-automatic, and reliable DXA-equivalent aBMD measurements for state-of-the-art DXA phantoms at different tube settings and for various patient habitus, as well as for sample patients. • Considering the number of CT scout scan acquisitions performed worldwide on a daily basis, the presented technique could enable truly opportunistic osteoporosis screening with DXA-equivalent metrics, without involving higher radiation exposure since it only processes existing data that is acquired during each CT scan.


Assuntos
Densidade Óssea/fisiologia , Osteoporose/diagnóstico por imagem , Tomografia Computadorizada por Raios X/métodos , Adulto , Fatores Etários , Idoso , Algoritmos , Estudos de Viabilidade , Feminino , Humanos , Processamento de Imagem Assistida por Computador/métodos , Pessoa de Meia-Idade , Imagens de Fantasmas , Reprodutibilidade dos Testes , Coluna Vertebral/diagnóstico por imagem , Adulto Jovem
15.
Eur Radiol ; 29(11): 6355-6363, 2019 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-31115622

RESUMO

OBJECTIVE: To investigate the in vivo applicability of non-contrast-enhanced hydroxyapatite (HA)-specific bone mineral density (BMD) measurements based on dual-layer CT (DLCT). METHODS: A spine phantom containing three artificial vertebral bodies with known HA densities was measured to obtain spectral data using DLCT and quantitative CT (QCT), simulating different patient positions and grades of obesity. BMD was calculated from virtual monoenergetic images at 50 and 200 keV. HA-specific BMD values of 174 vertebrae in 33 patients (66 ± 18 years; 33% women) were determined in non-contrast routine DLCT and compared with corresponding QCT-based BMD values. RESULTS: Examining the phantom, HA-specific BMD measurements were on a par with QCT measurements. In vivo measurements revealed strong correlations between DLCT and QCT (r = 0.987 [95% confidence interval, 0.963-1.000]; p < 0.001) and substantial agreement in a Bland-Altman plot. CONCLUSION: DLCT-based HA-specific BMD measurements were comparable with QCT measurements in in vivo analyses. This suggests that opportunistic DLCT-based BMD measurements are an alternative to QCT, without requiring phantoms and specific protocols. KEY POINTS: • DLCT-based hydroxyapatite-specific BMD measurements show a substantial agreement with QCT-based BMD measurements in vivo. • DLCT-based hydroxyapatite-specific measurements are on a par with QCT in spine phantom measurements. • Opportunistic DLCT-based BMD measurements may be a feasible alternative for QCT, without requiring dedicated examination protocols or a phantom.


Assuntos
Absorciometria de Fóton/métodos , Densidade Óssea/fisiologia , Osteoporose/diagnóstico por imagem , Coluna Vertebral/diagnóstico por imagem , Tomografia Computadorizada por Raios X/métodos , Adulto , Algoritmos , Feminino , Humanos , Masculino , Programas de Rastreamento/métodos , Pessoa de Meia-Idade , Osteoporose/fisiopatologia , Imagens de Fantasmas
16.
AJR Am J Roentgenol ; 213(2): 410-416, 2019 08.
Artigo em Inglês | MEDLINE | ID: mdl-31039015

RESUMO

OBJECTIVE. The purpose of this study was to systematically evaluate image quality, detectability of large-vessel occlusion or dissection, and diagnostic confidence in CT angiography (CTA) with virtually lowered tube current and iterative reconstruction in patients with suspected acute stroke. MATERIALS AND METHODS. Thirty patients (15 with large-vessel occlusion or dissection) underwent CTA of the supraaortal up to the intracranial arterial vessels. CTA scans were simulated as if they were made at 50% (D50), 25% (D25), and 10% (D10) of the original tube current. Image reconstruction was achieved with two levels of iterative reconstruction (A, similar to clinical reconstructions; B, two times stronger regularization). Two readers performed qualitative image evaluation considering overall image quality, artifacts, vessel contrast, detection of vessel abnormalities, and diagnostic confidence. RESULTS. Level B of iterative reconstruction was favorable regarding overall image quality and artifacts for D10, whereas level A was favorable for D100 and D50. CTA scans at D25 and both levels of iterative reconstruction still showed good vessel contrast, with even peripheral arterial branches of the anterior, middle, and posterior cerebral arteries being clearly detectable. Furthermore, CTA scans at D25 and level A of iterative reconstruction showed an adequate level of diagnostic confidence without any missed large-vessel occlusion or dissection according to evaluations by both readers. CONCLUSION. CTA with iterative reconstruction and tube currents decreased to 25% of that for original imaging is feasible without limitations in vessel contrast or detection of vessel abnormalities in patients with suspected acute stroke. Thus, the approach evaluated enables substantial reductions in radiation exposure for patients undergoing head and neck CTA.


Assuntos
Angiografia Cerebral/métodos , Angiografia por Tomografia Computadorizada/métodos , Doses de Radiação , Acidente Vascular Cerebral/diagnóstico por imagem , Adulto , Idoso , Idoso de 80 Anos ou mais , Artefatos , Meios de Contraste , Feminino , Humanos , Iopamidol/análogos & derivados , Masculino , Pessoa de Meia-Idade , Interpretação de Imagem Radiográfica Assistida por Computador , Estudos Retrospectivos
17.
J Comput Assist Tomogr ; 43(1): 61-65, 2019.
Artigo em Inglês | MEDLINE | ID: mdl-30211797

RESUMO

Statistical iterative reconstruction (SIR) using multidetector computed tomography (MDCT) is a promising alternative to standard filtered back projection (FBP), because of lower noise generation while maintaining image quality. Hence, we investigated the feasibility of SIR in predicting MDCT-based bone mineral density (BMD) and vertebral bone strength from finite element (FE) analysis. The BMD and FE-predicted bone strength derived from MDCT images reconstructed using standard FBP (FFBP) and SIR with (FSIR) and without regularization (FSIRB0) were validated against experimental failure loads (Fexp). Statistical iterative reconstruction produced the best quality images with regard to noise, signal-to-noise ratio, and contrast-to-noise ratio. Fexp significantly correlated with FFBP, FSIR, and FSIRB0. FFBP had a significant correlation with FSIRB0 and FSIR. The BMD derived from FBP, SIRB0, and SIR were significantly correlated. Effects of regularization should be further investigated with FE and BMD analysis to allow for an optimal iterative reconstruction algorithm to be implemented in an in vivo scenario.


Assuntos
Densidade Óssea , Análise de Elementos Finitos/estatística & dados numéricos , Processamento de Imagem Assistida por Computador/métodos , Tomografia Computadorizada Multidetectores/métodos , Coluna Vertebral/diagnóstico por imagem , Idoso , Cadáver , Estudos de Viabilidade , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Tomografia Computadorizada Multidetectores/estatística & dados numéricos , Razão Sinal-Ruído
18.
Acta Radiol ; 60(4): 478-487, 2019 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-29933714

RESUMO

BACKGROUND: Computed tomography pulmonary angiography (CTPA) is the standard imaging modality for detection or rule out of pulmonary embolism (PE); however, radiation exposure is a serious concern. With iterative reconstruction algorithms a distinct dose reduction could be achievable. PURPOSE: To evaluate a next generation iterative reconstruction algorithm for detection or rule-out of PE in simulated low-dose CTPA. MATERIAL AND METHODS: Low-dose CT datasets with 50%, 25%, and 12.5% of the original tube current were simulated based on CTPA examinations of 92 patients with suspected PE. All datasets were reconstructed with two reconstruction algorithms: standard filtered back-projection (FBP) and iterative model reconstruction (IMR). In total, 736 CTPA datasets were evaluated by three blinded radiologists regarding image quality, diagnostic confidence, and detectability of PE. Furthermore, contrast-to-noise ratio (CNR) was calculated. RESULTS: Images reconstructed with IMR showed better detectability of PE than images reconstructed with FBP, especially at lower dose levels. With IMR, sensitivity was over 95% for central and segmental PE down to a dose level of 25%. Significantly higher subjective image quality was shown at lower dose levels (25% and 12.5%) for IMR images whereas it was higher for FBP images at higher dose levels. FBP was rated as showing less artificial image appearance. CNR was significantly higher with IMR at all dose levels. CONCLUSION: By using IMR, a dose reduction of up to 50% while maintaining satisfactory image quality seems feasible in standard clinical situations, resulting in a mean effective dose of 1.38 mSv for CTPA.


Assuntos
Angiografia por Tomografia Computadorizada/métodos , Processamento de Imagem Assistida por Computador/métodos , Artéria Pulmonar/diagnóstico por imagem , Embolia Pulmonar/diagnóstico por imagem , Doses de Radiação , Interpretação de Imagem Radiográfica Assistida por Computador/métodos , Adulto , Idoso , Idoso de 80 Anos ou mais , Algoritmos , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Retrospectivos
19.
J Appl Clin Med Phys ; : e14429, 2024 May 29.
Artigo em Inglês | MEDLINE | ID: mdl-38808854
20.
Eur Radiol ; 28(7): 2743-2744, 2018 07.
Artigo em Inglês | MEDLINE | ID: mdl-29637267

RESUMO

This editorial comment refers to the article: Can We Perform CT of the Appendix with Less than 1 mSv? A De-escalating Dose-simulation Study. Park JH, et al., Eur Radiol, Dec 7, 2017.


Assuntos
Apêndice , Abdome , Tomografia Computadorizada por Raios X
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA