Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 90
Filtrar
1.
J Magn Reson Imaging ; 2024 Feb 02.
Artigo em Inglês | MEDLINE | ID: mdl-38308397

RESUMO

BACKGROUND: Multiple sclerosis (MS) lesion evolution may involve changes in diamagnetic myelin and paramagnetic iron. Conventional quantitative susceptibility mapping (QSM) can provide net susceptibility distribution, but not the discrete paramagnetic and diamagnetic components. PURPOSE: To apply susceptibility separation (χ separation) to follow lesion evolution in MS with comparison to R2 */R2 ' /QSM. STUDY TYPE: Longitudinal, prospective. SUBJECTS: Twenty relapsing-remitting MS subjects (mean age: 42.5 ± 9.4 years, 13 females; mean years of symptoms: 4.3 ± 1.4 years). FIELD STRENGTH/SEQUENCE: Three-dimensional multiple echo gradient echo (QSM and R2 * mapping), two-dimensional dual echo fast spin echo (R2 mapping), T2 -weighted fluid attenuated inversion recovery, and T1-weighted magnetization prepared gradient echo sequences at 3 T. ASSESSMENT: Data were analyzed from two scans separated by a mean interval of 14.4 ± 2.0 months. White matter lesions on fluid-attenuated inversion recovery were defined by an automatic pipeline, then manually refined (by ZZ/AHW, 3/25 years' experience in MRI), and verified by a radiologist (MN, 25 years' experience in MS). Susceptibility separation yielded the paramagnetic and diamagnetic susceptibility content of each voxel. Lesions were classified into four groups based on the variation of QSM/R2 * or separated into positive/negative components from χ separation. STATISTICAL TESTS: Two-sample paired t tests for assessment of longitudinal differences. Spearman correlation coefficients to assess associations between χ separation and R2 */R2 ' /QSM. Significant level: P < 0.005. RESULTS: A total of 183 lesions were quantified. Categorizing lesions into groups based on χ separation demonstrated significant annual changes in QSM//R2 */R2 ' . When lesions were grouped based on changes in QSM and R2 *, both changing in unison yielded a significant dominant paramagnetic variation and both opposing yielded a dominant diamagnetic variation. Significant Spearman correlation coefficients were found between susceptibility-sensitive MRI indices and χ separation. DATA CONCLUSION: Susceptibility separation changes in MS lesions may distinguish and quantify paramagnetic and diamagnetic evolution, potentially providing additional insight compared to R2 * and QSM alone. LEVEL OF EVIDENCE: 2 TECHNICAL EFFICACY: Stage 2.

2.
Clin Transplant ; 38(9): e15455, 2024 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-39254094

RESUMO

INTRODUCTION: Sarcopenia is common in children after liver transplantation (LTx). Resistance training (RT) may be effective in combating sarcopenia. OBJECTIVES: The purpose of the study was to test the feasibility and impact of a 12-week RT program on skeletal muscle mass (SMM), muscle strength, physical performance (PP), and child-parent perspectives about RT. METHODS: Children (6-18 years) post-LTx and healthy controls (HC) underwent progressive RT using resistance bands. SMM and adipose tissue (MRI: abdomen and thigh), muscle strength (handgrip, push-ups, sit-to-stand), and PP (6-minute walk test [6MWT], timed-up-and-down-stair test [TUDS]) were measured before and after 12-weeks of RT. RESULTS: Ten children post-LTx (11.9 ± 3.5 years) and 13 HC (11.7 ± 3.9 years) participated. LTx children significantly increased abdominal SM-index (+4.6% LTx vs. a -2.7% HC; p = 0.01) and decreased visceral adipose tissue-index (-18% LTx vs. -0.8% HC; p = 0.04) compared to HC. No thigh SMI changes were noted. Significant increases in 6MWT distance (LTx; p = 0.04), number of push-ups (p = 0.04), and greater reduction times for TUDS (-10.6% vs. +1.7%; p = 0.05) occurred after 12 weeks. Higher thigh muscle-fat content was associated with worse physical performance. These results were impacted by adherence (≥75% vs. <75%) and family engagement. CONCLUSIONS: RT in children post-LTx is feasible and effective. RT in children post-LTx may alleviate adverse outcomes associated with sarcopenia.


Assuntos
Transplante de Fígado , Força Muscular , Treinamento Resistido , Sarcopenia , Humanos , Masculino , Transplante de Fígado/efeitos adversos , Projetos Piloto , Sarcopenia/etiologia , Criança , Feminino , Adolescente , Prognóstico , Estudos de Casos e Controles , Seguimentos , Treinamento Resistido/métodos , Músculo Esquelético/fisiopatologia , Complicações Pós-Operatórias , Serviços de Assistência Domiciliar
3.
Pediatr Radiol ; 53(6): 1092-1099, 2023 05.
Artigo em Inglês | MEDLINE | ID: mdl-36539566

RESUMO

BACKGROUND: Fontan associated liver disease (FALD) is an increasingly recognized complication of the single ventricle circulation characterized by hepatic venous congestion leading to hepatic fibrosis. Within the Fontan myocardium, fibrotic myocardial remodeling may occur and lead to ventricular dysfunction. Magnetic resonance imaging (MRI) T1 mapping can characterize both myocardial and liver properties. OBJECTIVE: The aim of this study was to compare myocardial and liver T1 between single ventricle patients with and without a Fontan and biventricular controls. MATERIALS AND METHODS: A retrospective study of 3 groups of patients: 16 single ventricle patients before Fontan (SVpre 2 newborns, 9 pre-Glenn, 5 pre-Fontan, 31% single right ventricle [SRV]), 16 Fontans (56% SRV) and 10 repaired d-transposition of the great arteries (TGA). Native modified Look-Locker inversion T1 times were measured in the myocardium and liver. Cardiac MRI parameters, myocardial and liver T1 values were compared in the three groups. Correlations were assessed between liver T1 and cardiac parameters. RESULTS: Myocardial T1 was higher in SVpre (1,056 ± 48 ms) and Fontans (1,047 ± 41 ms) compared to TGA (1,012 ± 48 ms, P < 0.05). Increased liver T1 was found in both SVpre (683 ± 82 ms) and Fontan (727 ± 49 ms) patients compared to TGA patients (587 ± 58 ms, P < 0.001). There was no difference between single left ventricle (SLV) versus SRV myocardial or liver T1. Liver T1 showed moderate correlations with myocardial T1 (r = 0.48, confidence interval [CI] 0.26-0.72) and ejection fraction (r = -0.36, CI -0.66-0.95) but not with other volumetric parameters. CONCLUSION: Increased liver T1 at both pre- and post-Fontan stages suggests there are intrinsic liver abnormalities early in the course of single ventricle palliation. Increased myocardial T1 and its relationship to liver T1 suggest a combination of edema from passive venous congestion and/or myocardial fibrosis occurring in this population. Liver T1 may provide an earlier marker of liver disease warranting further study.


Assuntos
Hiperemia , Transposição dos Grandes Vasos , Recém-Nascido , Humanos , Estudos Retrospectivos , Hiperemia/patologia , Miocárdio/patologia , Fibrose , Fígado/diagnóstico por imagem , Fígado/patologia , Imagem Cinética por Ressonância Magnética , Valor Preditivo dos Testes
4.
Respir Res ; 23(1): 333, 2022 Dec 08.
Artigo em Inglês | MEDLINE | ID: mdl-36482438

RESUMO

BACKGROUND: The nasal cannula is considered a trusted and effective means of administering low-flow oxygen and is widely used for neonates and infants requiring oxygen therapy, despite an understanding that oxygen concentrations delivered to patients are variable. METHODS: In the present study, realistic nasal airway replicas derived from medical scans of children less than 3 months old were used to measure the fraction of oxygen inhaled (FiO2) through nasal cannulas during low-flow oxygen delivery. Parameters influencing variability in FiO2 were evaluated, as was the hypothesis that measured FiO2 values could be predicted using a simple, flow-weighted calculation that assumes ideal mixing of oxygen with entrained room air. Tidal breathing through neonatal and infant nasal airway replicas was controlled using a lung simulator. Parameters for nasal cannula oxygen flow rate, nasal airway geometry, tidal volume, respiratory rate, inhalation/exhalation, or I:E ratio (ti/te), breath waveform, and cannula prong insertion position were varied to determine their effect on measured FiO2. In total, FiO2 was measured for 384 different parameter combinations, with each combination repeated in triplicate. Analysis of variance (ANOVA) was used to assess the influence of parameters on measured FiO2. RESULTS: Measured FiO2 was not appreciably affected by the breath waveform shape, the replica geometry, or the cannula position but was significantly influenced by the tidal volume, the inhalation time, and the nasal cannula flow rate. CONCLUSIONS: The flow-weighted calculation overpredicted FiO2 for measured values above 60%, but an empirical correction to the calculation provided good agreement with measured FiO2 across the full range of experimental data.


Assuntos
Cânula , Oxigênio , Criança , Recém-Nascido , Humanos , Lactente
5.
Respir Res ; 22(1): 289, 2021 Nov 10.
Artigo em Inglês | MEDLINE | ID: mdl-34758818

RESUMO

BACKGROUND: For children and adults, the standard treatment for obstructive sleep apnea is the delivery of continuous positive airway pressure (CPAP). Though effective, CPAP masks can be uncomfortable to patients, contributing to adherence concerns. Recently, nasal high flow (NHF) therapy has been investigated as an alternative, especially in CPAP-intolerant children. The present study aimed to compare and contrast the positive airway pressures and expired gas washout generated by NHF versus CPAP in child nasal airway replicas. METHODS: NHF therapy was investigated at a flow rate of 20 L/min and compared to CPAP at 5 cmH2O and 10 cmH2O for 10 nasal airway replicas, built from computed tomography scans of children aged 4-8 years. NHF was delivered with three different high flow nasal cannula models provided by the same manufacturer, and CPAP was delivered with a sealed nasal mask. Tidal breathing through each replica was imposed using a lung simulator, and airway pressure at the trachea was recorded over time. For expired gas washout measurements, carbon dioxide was injected at the lung simulator, and end-tidal carbon dioxide (EtCO2) was measured at the trachea. Changes in EtCO2 compared to baseline values (no intervention) were assessed. RESULTS: NHF therapy generated an average positive end-expiratory pressure (PEEP) of 5.17 ± 2.09 cmH2O (mean ± SD, n = 10), similar to PEEP of 4.95 ± 0.03 cmH2O generated by nominally 5 cmH2O CPAP. Variation in tracheal pressure was higher between airway replicas for NHF compared to CPAP. EtCO2 decreased from baseline during administration of NHF, whereas it increased during CPAP. No statistical difference in tracheal pressure nor EtCO2 was found between the three high flow nasal cannulas. CONCLUSION: In child airway replicas, NHF at 20 L/min generated average PEEP similar to CPAP at 5 cm H2O. Variation in tracheal pressure was higher between airway replicas for NHF than for CPAP. The delivery of NHF yielded expired gas washout, whereas CPAP impeded expired gas washout due to the increased dead space of the sealed mask.


Assuntos
Cânula , Dióxido de Carbono/análise , Pressão Positiva Contínua nas Vias Aéreas/métodos , Respiração , Apneia Obstrutiva do Sono/terapia , Criança , Pré-Escolar , Feminino , Humanos , Masculino , Apneia Obstrutiva do Sono/metabolismo , Apneia Obstrutiva do Sono/fisiopatologia , Traqueia
6.
Pediatr Cardiol ; 42(8): 1805-1817, 2021 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-34196756

RESUMO

Right ventricular (RV) volumetric cardiac magnetic resonance (CMR) criteria serve as indicators for pulmonary valve replacement (PVR) in repaired tetralogy of Fallot (rTOF). Myocardial deformation and tricuspid valve displacement parameters may be more sensitive measures of RV dysfunction. This study's aim was to describe rTOF RV deformation and tricuspid displacement patterns using novel CMR semi-automated software and determine associations with standard CMR measures. Retrospective study of 78 pediatric rTOF patients was compared to 44 normal controls. Global RV longitudinal and circumferential strain and strain rate (SR) and tricuspid valve (TV) displacement were measured. Correlation analysis between strain, SR, TV displacement, and volumes was performed between and within subgroups. The sensitivity and specificity of strain parameters in predicting CMR criteria for PVR was determined. Deformation variables were reduced in rTOF compared to controls. Decreased RV strain and TV shortening were associated with increased RV volumes and decreased RVEF. Longitudinal and circumferential parameters were predictive of RVESVi (> 80 ml/m2) and RVEF (< 47%), with circumferential strain (> - 15.88%) and SR (> - 0.62) being most sensitive. Longitudinal strain was unchanged between rTOF subgroups, while circumferential strain trended abnormal in those meeting PVR criteria compared to controls. RV deformation and TV displacement are abnormal in rTOF, and RV circumferential strain variation may reflect an adaptive response to chronic volume or pressure load. This coupled with associations of ventricular deformation with traditional PVR indications suggest importance of this analysis in the evolution of rTOF RV assessment.


Assuntos
Insuficiência da Valva Pulmonar , Valva Pulmonar , Tetralogia de Fallot , Disfunção Ventricular Direita , Criança , Humanos , Imageamento por Ressonância Magnética , Valva Pulmonar/diagnóstico por imagem , Valva Pulmonar/cirurgia , Insuficiência da Valva Pulmonar/diagnóstico por imagem , Insuficiência da Valva Pulmonar/cirurgia , Estudos Retrospectivos , Tetralogia de Fallot/diagnóstico por imagem , Tetralogia de Fallot/cirurgia , Disfunção Ventricular Direita/diagnóstico por imagem , Disfunção Ventricular Direita/etiologia , Função Ventricular Direita
8.
Pediatr Radiol ; 48(10): 1488-1502, 2018 09.
Artigo em Inglês | MEDLINE | ID: mdl-30079444

RESUMO

Extracorporeal membrane oxygenation (ECMO) is a life-saving treatment for pediatric patients with respiratory and/or cardiac failure. The ECMO circuit oxygenates and sometimes pumps the blood, effectively replacing lung and/or heart function temporarily. ECMO patients are clinically very complex not only because of their underlying, life-threatening pathology, but also because of the many physiological parameters that must be monitored and adjusted to maintain adequate tissue perfusion and oxygenation. Drainage and reinfusion cannulae connecting the patient to the ECMO circuit are visible on radiograph. These cannulae have different functions, different configurations, different radiographic appearances, and different positions that should be familiar to the interpreting pediatric radiologist. The primary complications of ECMO include hemorrhage, thrombosis and ischemia, as well as equipment failure and cannula malpositioning, all of which may be detected on imaging. In this pictorial essay, we discuss the basics of ECMO function and clinical management, ECMO cannula features and configurations, and the many complications of ECMO from an imaging perspective. Our goal is to educate pediatric radiologists about ECMO imaging, equipping them to properly interpret these studies and to become a useful consultant in ECMO patient care.


Assuntos
Oxigenação por Membrana Extracorpórea , Insuficiência Cardíaca/terapia , Pediatria/métodos , Radiografia Torácica , Insuficiência Respiratória/terapia , Criança , Humanos
10.
Pediatr Radiol ; 46(7): 991-1002, 2016 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-27003135

RESUMO

BACKGROUND: Standardized methods to evaluate atrial properties in single ventricles are lacking. OBJECTIVE: To determine the feasibility of quantifying right atrial volumes and function in hypoplastic left heart using MRI. MATERIALS AND METHODS: We studied 15 infants with hypoplastic left heart prior to Glenn surgery (mean age 4.2 months [standard deviation 0.3]) who underwent cardiac MRI with evaluation of atrial volumes and emptying fraction using monoplane two-chamber, monoplane four-chamber, and biplane methods, all of which were compared to the atrial short-axial oblique stack method. We compared atrial end-diastolic volume, end-systolic volume and emptying fraction among these methods. We analyzed reproducibility of the methods using Bland‒Altman plots. RESULTS: Both four-chamber and biplane methods showed high correlations for atrial end-diastolic volume (r = 0.7 and r = 0.8, respectively; P < 0.01) and end-systolic volume (r = 0.8 and r = 0.9, respectively; P < 0.01) with small mean differences (-0.2 ± 2.9 standard deviation [SD] ml and -0.8 ± 1.6 ml, respectively, for atrial end-diastolic volume and -0.8 ± 1.5 ml and -0.9 ± 0.9 ml, respectively, for atrial end-systolic volume). The short-axial oblique method was the most reproducible, followed by the four-chamber method. CONCLUSION: MRI assessment of atrial volume and function is feasible in hypoplastic left heart and might provide further insight into single-ventricle mechanics.


Assuntos
Átrios do Coração/diagnóstico por imagem , Átrios do Coração/patologia , Síndrome do Coração Esquerdo Hipoplásico/diagnóstico por imagem , Imageamento por Ressonância Magnética/métodos , Estudos de Viabilidade , Feminino , Humanos , Interpretação de Imagem Assistida por Computador , Lactente , Masculino , Reprodutibilidade dos Testes , Resultado do Tratamento
11.
Am J Orthod Dentofacial Orthop ; 150(4): 703-712, 2016 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-27692428

RESUMO

INTRODUCTION: Our objectives were to assess reliability, validity, and time efficiency of semiautomatic segmentation using Segura software of the nasal and pharyngeal airways, against manual segmentation with point-based analysis with color mapping. METHODS: Pharyngeal and nasal airways from 10 cone-beam computed tomography image sets were segmented manually and semiautomatically using Segura (University of Alberta, Edmonton, Alberta, Canada). To test intraexaminer and interexaminer reliabilities, semiautomatic segmentation was repeated 3 times by 1 examiner and then by 3 examiners. In addition to volume and surface area, point-based analysis was completed to assess the reconstructed 3-dimensional models from Segura against manual segmentation. The times of both methods of segmentation were also recorded to assess time efficiency. RESULTS: The reliability and validity of Segura were excellent (intraclass correlation coefficient, >0.9 for volume and surface area). Part analysis showed small differences between the Segura and manually segmented 3-dimensional models (greatest difference did not exceed 4.3 mm). Time of segmentation using Segura was significantly shorter than that for manual segmentation, 49 ± 11.0 vs 109 ± 9.4 minutes (P <0.001). CONCLUSIONS: Semiautomatic segmentation of the pharyngeal and nasal airways using Segura was found to be reliable, valid, and time efficient. Part analysis with color mapping was the key to explaining differences in upper airway volume and provides meaningful and clinically relevant analysis of 3-dimensional changes.


Assuntos
Algoritmos , Tomografia Computadorizada de Feixe Cônico , Interpretação de Imagem Assistida por Computador/métodos , Imageamento Tridimensional/métodos , Cavidade Nasal/diagnóstico por imagem , Faringe/diagnóstico por imagem , Ventilação Pulmonar/fisiologia , Adolescente , Criança , Feminino , Humanos , Masculino , Variações Dependentes do Observador , Reprodutibilidade dos Testes , Estudos Retrospectivos
12.
Pediatr Int ; 57(5): 974-7, 2015 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-26508178

RESUMO

Adenovirus-induced fulminant hepatitis is rare. It has been reported in children with primary immunodeficiency, following transplantation or while receiving chemotherapy for hematological malignancy. We present the case of an infant recovering from chemotherapy for atypical teratoid rhabdoid tumor (ATRT) in whom a diagnosis of hepatic necrosis due to adenovirus was made.


Assuntos
Adenoviridae/isolamento & purificação , Neoplasias Encefálicas/complicações , Hepatite Viral Humana/etiologia , Fígado/patologia , Tumor Rabdoide/complicações , Teratoma/complicações , Adenoviridae/genética , Biópsia , Neoplasias Encefálicas/diagnóstico , DNA Viral/análise , Evolução Fatal , Hepatite Viral Humana/diagnóstico , Hepatite Viral Humana/virologia , Humanos , Lactente , Fígado/virologia , Imageamento por Ressonância Magnética , Masculino , Microscopia Eletrônica , Necrose , Reação em Cadeia da Polimerase , Tumor Rabdoide/diagnóstico , Teratoma/diagnóstico
13.
Pediatr Cardiol ; 36(2): 289-94, 2015 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-25124721

RESUMO

Certain pediatric patients undergoing surgery for the most severe forms of congenital heart disease are exposed to high doses of ionizing radiation. The amount of cumulative radiation exposure from all modalities has not yet been evaluated. The purpose of our study was to evaluate the cumulative radiation exposure in a contemporary cohort of patients with congenital heart disease undergoing single-ventricle palliation. This is a single-center, retrospective study of pediatric patients undergoing Fontan completion between May 2005 and May 2010. Radiation exposure from all procedures including cardiac catheterizations, computed tomography (CT) scans, plain film radiography, and nuclear medicine scans was evaluated. Radiation dose was calculated as the dose area product (µGy m(2)) and was measured in all cardiac catheterizations, CT scans, and other imaging modalities. Seventy patients who underwent Fontan completion at a mean age of 3.6 ± 1.5 years (range 1.4-8 years) were included in the study. Mean number of chest X-rays was 32 ± 8 (range 10-285) with a mean cumulative total exposure of 1,320 µGy m(2) (range 480-12,960) per patient. Mean number of cardiac catheterizations was 2.45 ± 1.3 (range 1-8), and mean fluoroscopy and cine angiography exposures per case were 1,103 ± 245 and 1,412 ± 273 µGy m(2) giving a mean cumulative exposure of 9,054 µGy m(2) (range 2,515-201,200) per patient for all catheterizations. Mean number of CT scans performed was 0.44 ± 0.4 (0-11), and the mean exposure was 352 µGy m(2), giving a mean cumulative total of 154 µGy m(2) (range 0-3,872) per person. A total of five lung perfusion scans were carried out. Radiation exposure in patients with congenital heart disease undergoing single-ventricle palliation is quite variable. Most of the exposure to ionizing radiation occurs during cardiac catheterization. Strategies to utilize other imaging modalities such as MRI would decrease exposure in this particular group of patients who may be particularly vulnerable to its side effects.


Assuntos
Cardiopatias Congênitas/diagnóstico , Ventrículos do Coração/anormalidades , Cateterismo Cardíaco/estatística & dados numéricos , Criança , Pré-Escolar , Diagnóstico por Imagem , Feminino , Técnica de Fontan , Cardiopatias Congênitas/cirurgia , Humanos , Síndrome do Coração Esquerdo Hipoplásico/diagnóstico , Síndrome do Coração Esquerdo Hipoplásico/cirurgia , Lactente , Pulmão/diagnóstico por imagem , Imageamento por Ressonância Magnética , Masculino , Radiação Ionizante , Cintilografia , Estudos Retrospectivos , Tomografia Computadorizada por Raios X/estatística & dados numéricos
14.
Can Assoc Radiol J ; 66(3): 192-7, 2015 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-25896452

RESUMO

Medical radiation should be used appropriately and with a dose as low as reasonably achievable. Dose monitoring technologies have been developed that automatically accumulate patient dose indicators, providing effective dose estimates and patient-specific dose histories. Deleterious radiation related events have prompted increased public interest in the safe use of medical radiation. Some view individualized patient dose histories as a tool to help manage the patient dose. However, it is imperative that dose monitoring technologies be evaluated on the outcomes of dose reduction and effective patient management. Patient dose management needs to be consistent with the widely accepted linear no-threshold model of stochastic radiation effects. This essay reviews the attributes and limitations of dose monitoring technologies to provoke discussion regarding resource allocation in the current fiscally constrained health care system.


Assuntos
Doses de Radiação , Proteção Radiológica/normas , Radiometria/instrumentação , Sistema de Registros , Canadá , Humanos , Sociedades Médicas
15.
BMC Cardiovasc Disord ; 14: 91, 2014 Jul 25.
Artigo em Inglês | MEDLINE | ID: mdl-25063541

RESUMO

BACKGROUND: Nationally, symptomatic heart failure affects 1.5-2% of Canadians, incurs $3 billion in hospital costs annually and the global burden is expected to double in the next 1-2 decades. The current one-year mortality rate after diagnosis of heart failure remains high at >25%. Consequently, new therapeutic strategies need to be developed for this debilitating condition. METHODS/DESIGN: The objective of the Alberta HEART program (http://albertaheartresearch.ca) is to develop novel diagnostic, therapeutic and prognostic approaches to patients with heart failure with preserved ejection fraction. We hypothesize that novel imaging techniques and biomarkers will aid in describing heart failure with preserved ejection fraction. Furthermore, the development of new diagnostic criteria will allow us to: 1) better define risk factors associated with heart failure with preserved ejection fraction; 2) elucidate clinical, cellular and molecular mechanisms involved with the development and progression of heart failure with preserved ejection fraction; 3) design and test new therapeutic strategies for patients with heart failure with preserved ejection fraction. Additionally, Alberta HEART provides training and education for enhancing translational medicine, knowledge translation and clinical practice in heart failure. This is a prospective observational cohort study of patients with, or at risk for, heart failure. Patients will have sequential testing including quality of life and clinical outcomes over 12 months. After that time, study participants will be passively followed via linkage to external administrative databases. Clinical outcomes of interest include death, hospitalization, emergency department visits, physician resource use and/or heart transplant. Patients will be followed for a total of 5 years. DISCUSSION: Alberta HEART has the primary objective to define new diagnostic criteria for patients with heart failure with preserved ejection fraction. New criteria will allow for targeted therapies, diagnostic tests and further understanding of the patients, both at-risk for and with heart failure. TRIAL REGISTRATION: ClinicalTrials.gov NCT02052804.


Assuntos
Diagnóstico por Imagem , Insuficiência Cardíaca/diagnóstico , Insuficiência Cardíaca/terapia , Projetos de Pesquisa , Alberta/epidemiologia , Biomarcadores/sangue , Diagnóstico por Imagem/métodos , Serviço Hospitalar de Emergência/estatística & dados numéricos , Recursos em Saúde/estatística & dados numéricos , Insuficiência Cardíaca/sangue , Insuficiência Cardíaca/etiologia , Insuficiência Cardíaca/mortalidade , Transplante de Coração/estatística & dados numéricos , Hospitalização , Humanos , Visita a Consultório Médico/estatística & dados numéricos , Valor Preditivo dos Testes , Estudos Prospectivos , Medição de Risco , Fatores de Risco , Volume Sistólico , Fatores de Tempo , Resultado do Tratamento , Função Ventricular Esquerda
16.
Can Assoc Radiol J ; 65(3): 218-24, 2014 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-24650872

RESUMO

PURPOSE: To assess ultrasound intrascan variability and the potential error rate of serial ultrasounds in the diagnosis of deep venous thrombosis in children. METHODS: A retrospective cohort review of imaging results of children having at least 3 serial ultrasound examinations of the same region within a 2-month period. The results were interpreted as either (1) inadequately visualized or (2) the absence or presence of deep venous thrombosis, and were categorized by location. Serial imaging findings then were further categorized based on results and clinical information. RESULTS: Sixty-four patients and 157 vessel segments were included in the study. Deep venous thrombosis was documented in 58 patients. Concordant results were observed in 26 patients (40.1%), clot resolution in 17 patients (26.6%), clot formation in 12 patients (18.8%), and discordant results in 9 patients (14%). Twenty-one of 64 patients (32.8%) had at least 1 vessel inadequately imaged. CONCLUSIONS: The inconsistency of serial ultrasound results in up to 25% of patients calls attention to the potential inaccuracy of ultrasound for diagnosis and follow-up of deep venous thrombosis in children. The high proportion of patients with at least 1 inadequately visualized vessel also highlights the limitation of ultrasound in the diagnosis of pediatric deep venous thrombosis.


Assuntos
Trombose Venosa/diagnóstico por imagem , Adolescente , Alberta/epidemiologia , Criança , Pré-Escolar , Feminino , Humanos , Lactente , Recém-Nascido , Masculino , Reprodutibilidade dos Testes , Estudos Retrospectivos , Ultrassonografia , Trombose Venosa/epidemiologia
17.
Respir Care ; 69(4): 438-448, 2024 Mar 27.
Artigo em Inglês | MEDLINE | ID: mdl-38443141

RESUMO

BACKGROUND: The nasal cannula is widely regarded as a safe and effective means of administering low- and high-flow oxygen to patients irrespective of their age. However, variability in delivered oxygen concentration (FDO2 FDO2 ) via nasal cannula has the potential to pose health risks. The present study aimed to evaluate predictive equations for FDO2 over a large parameter space, including variation in breathing, oxygen flow, and upper-airway geometry representative of both young children and adults. METHODS: Realistic nasal airway geometries were previously collected from medical scans of adults, infants, and neonates. Nasal airway replicas based on these geometries were used to measure the FDO2 for low-flow oxygen delivery during simulated spontaneous breathing. The present study extends previously published data sets to include higher oxygen flows. The extended data sets included nasal cannula oxygen flows that ranged from 6 to 65 L/min for the adult replicas, and from 0.5 to 6 L/min for the infant replicas. For both age groups, FDO2 was measured over a range of breathing frequencies, inspiratory to expiratory time ratios, and tidal volumes. Measured FDO2 values were compared with values predicted by using a previously derived flow-weighted equation. RESULTS: For both age groups, FDO2 was observed to increase nonlinearly with the ratio between oxygen flow supplied to the nasal cannula and the average inhalation flow. The previously derived flow-weighted equation over-predicted FDO2 at higher oxygen flows. A new empirical equation, therefore, was proposed to predict FDO2 for either age group as a function of nasal cannula flow, tidal volume, and inspiratory time. Predicted FDO2 values matched measured values, with average relative errors of 2.4% for infants and 4.3% for adults. CONCLUSIONS: A new predictive equation for FDO2 was obtained that accurately matched measured data in both adult and infant airway replicas for low- and high-flow regimens.


Assuntos
Cânula , Respiração , Recém-Nascido , Adulto , Lactente , Criança , Humanos , Pré-Escolar , Nariz , Oxigênio , Intubação , Oxigenoterapia
18.
AJR Am J Roentgenol ; 200(5): W444-9, 2013 May.
Artigo em Inglês | MEDLINE | ID: mdl-23617512

RESUMO

OBJECTIVE: Testicular torsion is a common acute condition in boys requiring prompt accurate management. The objective of this article was to evaluate ultrasound accuracy, findings, and clinical predictors in testicular torsion in boys presenting to the Stollery pediatric emergency department with acute scrotal pain. METHODS: Retrospective review of surgical and emergency department ultrasound records for boys from 1 month to 17 years old presenting with acute scrotal pain from 2008 to 2011 was performed. Clinical symptoms, ultrasound and surgical findings, and diagnoses were recorded. Surgical results and follow-up were used as the reference standard. RESULTS: Of 342 patients who presented to the emergency department with acute scrotum, 35 had testicular torsion. Of 266 ultrasound examinations performed, 29 boys had torsion confirmed by surgery. The false-positive rate for ultrasound was 2.6%, and there were no false-negative findings. Mean times from presentation at the emergency department to ultrasound and surgery were 209.4 and 309.4 minutes, respectively. Of the torsed testicles, 69% were salvageable. Sensitivity, specificity, and diagnostic accuracy of ultrasound for testicular torsion were 100%, 97.9%, and 98.1%, respectively. Sonographic heterogeneity was seen in 80% of nonviable testes at surgery and 58% of patients with viable testes (p = 0.41). Sudden-onset scrotal pain (88%), abnormal position (86%), and absent cremasteric reflex (91%) were most prevalent in torsion patients. CONCLUSION: Color Doppler ultrasound is accurate and sensitive for diagnosis of torsion in the setting of acute scrotum. Despite heterogeneity on preoperative ultrasound, many testes were considered to be salvageable at surgery. The salvage rate of torsed testes was high.


Assuntos
Abdome Agudo/diagnóstico por imagem , Abdome Agudo/cirurgia , Ecocardiografia Doppler em Cores/estatística & dados numéricos , Escroto/diagnóstico por imagem , Escroto/cirurgia , Torção do Cordão Espermático/diagnóstico por imagem , Torção do Cordão Espermático/cirurgia , Abdome Agudo/epidemiologia , Adolescente , Alberta/epidemiologia , Causalidade , Criança , Pré-Escolar , Humanos , Lactente , Recém-Nascido , Masculino , Prevalência , Reprodutibilidade dos Testes , Estudos Retrospectivos , Fatores de Risco , Sensibilidade e Especificidade , Torção do Cordão Espermático/epidemiologia , Resultado do Tratamento
19.
Appl Physiol Nutr Metab ; 48(10): 730-750, 2023 Oct 01.
Artigo em Inglês | MEDLINE | ID: mdl-37319441

RESUMO

TAKE-HOME MESSAGE: Skeletal muscle morphology in healthy children changes with age. Liver disease may preferentially affect type II fibres in adults with end-stage liver disease (ESLD). More research is needed on the effects of ESLD on muscle morphology in children.


Assuntos
Doença Hepática Terminal , Fibras Musculares Esqueléticas , Adulto , Humanos , Criança , Músculo Esquelético , Atrofia Muscular
20.
IEEE Trans Nanobioscience ; 22(4): 800-807, 2023 10.
Artigo em Inglês | MEDLINE | ID: mdl-37220045

RESUMO

Cardiac segmentation from magnetic resonance imaging (MRI) is one of the essential tasks in analyzing the anatomy and function of the heart for the assessment and diagnosis of cardiac diseases. However, cardiac MRI generates hundreds of images per scan, and manual annotation of them is challenging and time-consuming, and therefore processing these images automatically is of interest. This study proposes a novel end-to-end supervised cardiac MRI segmentation framework based on a diffeomorphic deformable registration that can segment cardiac chambers from 2D and 3D images or volumes. To represent actual cardiac deformation, the method parameterizes the transformation using radial and rotational components computed via deep learning, with a set of paired images and segmentation masks used for training. The formulation guarantees transformations that are invertible and prevents mesh folding, which is essential for preserving the topology of the segmentation results. A physically plausible transformation is achieved by employing diffeomorphism in computing the transformations and activation functions that constrain the range of the radial and rotational components. The method was evaluated over three different data sets and showed significant improvements compared to exacting learning and non-learning based methods in terms of the Dice score and Hausdorff distance metrics.


Assuntos
Aprendizado Profundo , Processamento de Imagem Assistida por Computador , Processamento de Imagem Assistida por Computador/métodos , Imageamento Tridimensional/métodos , Imageamento por Ressonância Magnética , Coração/diagnóstico por imagem
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA