Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 32
Filtrar
1.
Radiology ; 300(1): 2-16, 2021 07.
Artigo em Inglês | MEDLINE | ID: mdl-34032509

RESUMO

Venous variants and pathologic abnormalities are the most common causes of pulsatile tinnitus. These conditions include causes of turbulence within normally located veins and sinuses, and abnormally enlarged or abnormally located veins in close transmissive proximity to the conductive auditory pathway. Such disorders include pathologic abnormalities of the lateral sinus (transverse sinus stenosis and sigmoid sinus wall anomalies), abnormalities and variants of the emissary veins, and anomalies of the jugular bulb and jugular vein. Despite being the most common causes for pulsatile tinnitus, venous variants and pathologic abnormalities are often overlooked in the workup of pulsatile tinnitus. Such oversights can result in delayed patient care and prolonged patient discomfort. Advances in both cerebrovascular imaging and endovascular techniques allow for improved diagnostic accuracy and an increasing range of endovascular therapeutic options to address pulsatile tinnitus. This review illustrates the venous causes of pulsatile tinnitus and demonstrates the associated endovascular treatment. © RSNA, 2021.


Assuntos
Procedimentos Endovasculares/métodos , Veias Jugulares/anormalidades , Zumbido/etiologia , Zumbido/cirurgia , Seios Transversos/anormalidades , Humanos , Veias Jugulares/diagnóstico por imagem , Imageamento por Ressonância Magnética/métodos , Tomografia Computadorizada por Raios X/métodos , Seios Transversos/diagnóstico por imagem
2.
J Magn Reson Imaging ; 44(6): 1580-1591, 2016 12.
Artigo em Inglês | MEDLINE | ID: mdl-27122183

RESUMO

PURPOSE: Gadolinium-based contrast agents have associated risks. Normal saline (NS) is a nontoxic sodium chloride water solution that can significantly increase the magnetic resonance imaging (MRI) relaxation times of blood via transient hemodilution (THD). The purpose of this pilot study was to test in vivo in the head the potential of normal saline as a safer, exogenous perfusion contrast agent. MATERIALS AND METHODS: This Health Insurance Portability and Accountability Act (HIPAA)-compliant prospective study was approved by the local Institutional Review Board (IRB): 12 patients were scanned with T1 -weighted inversion recovery turbo spin echo pulse sequence at 1.5T. The dynamic inversion recovery pulse sequence was run before, during, and after the NS injection for up to 5 minutes: 100 ml of NS was power-injected via antecubital veins at 3-4 ml/s. Images were processed to map maximum enhancement area-under-the-curve, time-to-peak, and mean-transit-time. These maps were used to identify the areas showing significant NS injection-related signal and to generate enhancement time curves. Hardware and pulse sequence stability were studied via phantom experimentation. Main features of the time curves were tested against theoretical modeling of THD signal effects using inversion recovery pulse sequences. Pearson correlation coefficient (R) mapping was used to differentiate genuine THD effects from motion confounders and noise. RESULTS: The scans of 8 out of 12 patients showed NS injection-related effects that correlate in magnitude with tissue type (gray matter ∼15% and white matter ∼3%). Motion artifacts prevented ascertaining NS signal effects in the remaining four patients. Positive and negative time curves were observed in vivo and this dual THD signal polarity was also observed in the theoretical simulations. R-histograms that were approximately constant in the range 0.1 < |R| < 0.8 and leading to correlation fractions of Fcorr (|R| > 0.5) = 0.45 and 0.59 were found to represent scans with genuine THD signal effects. CONCLUSION: A measurable perfusion effect in brain tissue was demonstrated in vivo using NS as an injectable intravascular contrast agent. J. Magn. Reson. Imaging 2016;44:1580-1591.


Assuntos
Velocidade do Fluxo Sanguíneo/fisiologia , Encéfalo/fisiologia , Angiografia Cerebral/métodos , Circulação Cerebrovascular/fisiologia , Angiografia por Ressonância Magnética/métodos , Cloreto de Sódio , Adulto , Meios de Contraste , Estudos de Viabilidade , Feminino , Humanos , Aumento da Imagem/métodos , Interpretação de Imagem Assistida por Computador/métodos , Masculino , Projetos Piloto , Reprodutibilidade dos Testes , Sensibilidade e Especificidade
4.
Stroke ; 45(1): 141-5, 2014 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-24302483

RESUMO

BACKGROUND AND PURPOSE: Efficient and timely recanalization is an important goal in acute stroke endovascular therapy. Several studies demonstrated improved recanalization and clinical outcomes with the stent retriever devices compared with the Merci device. The goal of this study was to evaluate the role of the balloon guide catheter (BGC) and recanalization success in a substudy of the North American Solitaire Acute Stroke (NASA) registry. METHODS: The investigator-initiated NASA registry recruited 24 clinical sites within North America to submit demographic, clinical, site-adjudicated angiographic, and clinical outcome data on consecutive patients treated with the Solitaire Flow Restoration device. BGC use was at the discretion of the treating physicians. RESULTS: There were 354 patients included in the NASA registry. BGC data were reported in 338 of 354 patients in this subanalysis, of which 149 (44%) had placement of a BGC. Mean age was 67.3±15.2 years, and median National Institutes of Health Stroke Scale score was 18. Patients with BGC had more hypertension (82.4% versus 72.5%; P=0.05), atrial fibrillation (50.3% versus 32.8%; P=0.001), and were more commonly administered tissue plasminogen activator (51.6% versus 38.8%; P=0.02) compared with patients without BGC. Time from symptom onset to groin puncture and number of passes were similar between the 2 groups. Procedure time was shorter in patients with BGC (120±28.5 versus 161±35.6 minutes; P=0.02), and less adjunctive therapy was used in patients with BGC (20% versus 28.6%; P=0.05). Thrombolysis in cerebral infarction 3 reperfusion scores were higher in patients with BGC (53.7% versus 32.5%; P<0.001). Distal emboli and emboli in new territory were similar between the 2 groups. Discharge National Institutes of Health Stroke Scale score (mean, 12±14.5 versus 17.5±16; P=0.002) and good clinical outcome at 3 months were superior in patients with BGC compared with patients without (51.6% versus 35.8%; P=0.02). Multivariate analysis demonstrated that the use of BGC was an independent predictor of good clinical outcome (odds ratio, 2.5; 95% confidence interval, 1.2-4.9). CONCLUSIONS: Use of a BGC with the Solitaire Flow Restoration device resulted in superior revascularization results, faster procedure times, decreased need for adjunctive therapy, and improved clinical outcome.


Assuntos
Cateterismo Venoso Central/métodos , Revascularização Cerebral/métodos , Procedimentos Endovasculares/métodos , Stents , Acidente Vascular Cerebral/cirurgia , Idoso , Angiografia Cerebral , Circulação Cerebrovascular/fisiologia , Feminino , Humanos , Trombose Intracraniana/complicações , Masculino , Sistema de Registros , Fatores de Risco , Resultado do Tratamento
5.
J Comput Assist Tomogr ; 37(2): 272-8, 2013.
Artigo em Inglês | MEDLINE | ID: mdl-23493218

RESUMO

OBJECTIVE: To study age-related characteristics of T1 and T2 relaxation times and volume of the major salivary glands. METHODS: Thirty-five subjects (0.5-87 years old) with normal salivary glands were imaged with mixed turbo spin-echo pulse sequences at 1.5-T magnetic resonance units. Bilateral parotid, submandibular, and sublingual glands were segmented manually. Histograms for each salivary gland were generated and modeled with Gaussian functions for every parameter. RESULTS: Seventy parotid glands, 52 submandibular glands, and 50 sublingual glands were segmented and the histograms were analyzed. The parotid gland exhibited shorter-peak T1s and longer-peak T2s relative to the submandibular and sublingual glands. The peak T2s for all glands showed a minimum value between 2 and 4 years of age and increased monotonically thereafter. From birth to early adulthood, all glands increased in size logarithmically. CONCLUSION: Age-related relaxo-volumetric changes of the major salivary glands show clear T2 and volumetric age-related patterns for all glands.


Assuntos
Imageamento por Ressonância Magnética/métodos , Glândulas Salivares/anatomia & histologia , Adolescente , Adulto , Fatores Etários , Idoso , Idoso de 80 Anos ou mais , Algoritmos , Artefatos , Criança , Pré-Escolar , Feminino , Humanos , Processamento de Imagem Assistida por Computador , Lactente , Masculino , Pessoa de Meia-Idade
6.
Interv Neuroradiol ; 29(2): 196-200, 2023 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-35286223

RESUMO

BACKGROUND: Challenging arterial anatomy delays, or prevents timely endovascular treatment (EVT) of acute ischemic stroke (AIS). We introduce a new technique called 'Balloon Gliding Technique (BGT)' to overcome difficult arterial anatomy during EVT of AIS, utilizing flow-assistance to access challenging circulations. METHODS: Retrospective review of a prospectively collected database of all patients presenting to a single institution with AIS who underwent EVT was performed from January 2021 to June 2021. Patients in whom BGT was performed were assessed. BGT consists of advancing the balloon guide catheter in the cervical carotid artery while its balloon is inflated, and therefore carried by downstream flow. RESULTS: Of 51 patients presenting with AIS secondary to large vessel occlusion during the study period, five patients underwent BGT. All five patients had anterior circulation large vessel occlusions. Mean age of the BGT patients was 92.2 years, and all patients were females. A type 3 arch was present in all patients. BGT was performed in all cases following initial failure of conventional techniques to cannulate the target circulation. BGT was successful in achieving distal cervical carotid access in 4 out of the 5 patients in whom BGT was attempted. Successful recanalization (modified treatment in cerebral ischemia 2b-3) was obtained in all cases with no complications. CONCLUSIONS: Balloon Gliding Technique (BGT) is a safe technique that can safely overcome challenging anatomy during endovascular treatment of acute ischemic stroke. Further studies can assist in demonstrating both its safety and effectiveness.


Assuntos
Isquemia Encefálica , Procedimentos Endovasculares , AVC Isquêmico , Acidente Vascular Cerebral , Feminino , Humanos , Idoso de 80 Anos ou mais , Masculino , Acidente Vascular Cerebral/diagnóstico por imagem , Acidente Vascular Cerebral/cirurgia , AVC Isquêmico/complicações , Isquemia Encefálica/diagnóstico por imagem , Isquemia Encefálica/cirurgia , Cateterismo/métodos , Procedimentos Endovasculares/métodos , Catéteres/efeitos adversos , Estudos Retrospectivos , Resultado do Tratamento , Trombectomia/métodos
7.
J Neurol ; 270(11): 5131-5154, 2023 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-37535100

RESUMO

BACKGROUND: Coronavirus disease 2019 (COVID-19) has been associated with nervous system involvement, with more than one-third of COVID-19 patients experiencing neurological manifestations. Utilizing a systematic review, this study aims to summarize brain MRI findings in COVID-19 patients presenting with neurological symptoms. METHODS: Systematic review was conducted in accordance with the Preferred Reporting Items for Systematic Reviews and Meta-analysis (PRISMA) checklist. The electronic databases of PubMed/MEDLINE, Embase, Scopus, and Web of Science were systematically searched for literature addressing brain MRI findings in COVID-19 patients with neurological symptoms. RESULTS: 25 publications containing a total number of 3118 COVID-19 patients with neurological symptoms who underwent MRI were included. The most common MRI findings and the respective pooled incidences in decreasing order were acute/subacute infarct (22%), olfactory bulb abnormalities (22%), white matter abnormalities (20%), cerebral microbleeds (17%), grey matter abnormalities (12%), leptomeningeal enhancement (10%), ADEM (Acute Disseminated Encephalomyelitis) or ADEM-like lesions (10%), non-traumatic ICH (10%), cranial neuropathy (8%), cortical gray matter signal changes compatible with encephalitis (8%), basal ganglia abnormalities (5%), PRES (Posterior Reversible Encephalopathy Syndrome) (3%), hypoxic-ischemic lesions (4%), venous thrombosis (2%), and cytotoxic lesions of the corpus callosum (2%). CONCLUSION: The present study revealed that a considerable proportion of patients with COVID-19 might harbor neurological abnormalities detectable by MRI. Among various findings, the most common MRI alterations are acute/subacute infarction, olfactory bulb abnormalities, white matter abnormalities, and cerebral microbleeds.

8.
Med Phys ; 39(6): 3456-65, 2012 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-22755725

RESUMO

PURPOSE: To retrospectively compare different topogram-based patient body size indices and to determine the optimal topogram-based body size index as a basis for body computed tomography (CT) dose consideration and scan protocol optimization. METHODS: Forty-three routine thorax and abdomen CT scans are studied retrospectively, with patient ages ranging from 18 to 67 yr. The individual patient's water-equivalent diameter (D(w)) of the scanned body region is computed from CT DICOM images as the "gold standard," after first converting from Hounsfield units values to µa values, where µ is the normalized tissue attenuation coefficient and a is the area per pixel. Four topogram-based body size indices [average diameter (D), girth (G), topogram projection area (E(topo)), and improved topogram projection area (E(topo)('))] are computed and correlated with D(w) using linear regression analysis. Specifically, D is calculated by averaging the coronal and sagittal diameters; G is computed by modeling the patient's cross-section as an ellipse; E(topo) is the product of the mean topogram pixel value and the width of the scanned body region; and (E(topo)(')) incorporates E(topo) with correction of patient miscentering and water attenuation coefficient. The accuracy of these four approaches for estimation of D(w) is assessed using linear regression models. Results are given in terms of 95% confidence intervals (CIs). RESULTS: Regression analysis results in four different linear models. The standard error (95% CI) for estimation of D(w) from D and G was ±2.8 and ±3.1 cm, respectively (p = 0.297). The standard error for estimation of D(w) from E(topo) was significantly less than that from D (±2.1 cm, p < 0.01). The standard error for estimation of D(w) from (E(topo)(')) was ±1.3 cm, significantly less than that from E(topo) (p < 0.01). CONCLUSIONS: Among the four topogram-based patient body indices, (E(topo)(')) is the most accurate for estimation of individual x-ray attenuation of the scanned body region. Thus, (E(topo)(')) is an optimal topogram-based patient body size index that is relevant for determining the proper CT dose level for individual patients.


Assuntos
Tamanho Corporal , Doses de Radiação , Tomografia Computadorizada por Raios X/métodos , Adolescente , Adulto , Humanos , Pessoa de Meia-Idade , Imagens de Fantasmas , Radiografia Abdominal , Radiografia Torácica , Análise de Regressão , Estudos Retrospectivos , Água/metabolismo , Adulto Jovem
9.
Neuroradiol J ; 35(1): 25-35, 2022 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-34398721

RESUMO

The simultaneous growth of robotic-assisted surgery and telemedicine in recent years has only been accelerated by the recent coronavirus disease 2019 pandemic. Robotic assistance for neurovascular intervention has garnered significant interest due to opportunities for tele-stroke models of care for remote underserved areas. Lessons learned from medical robots in interventional cardiology and neurosurgery have contributed to incremental but vital advances in medical robotics despite important limitations. In this article, we discuss robot types and their clinical justification and ethics, as well as a general overview on available robots in thoracic/abdominal surgery, neurosurgery, and cardiac electrophysiology. We conclude with current clinical research in neuroendovascular intervention and a perspective on future directions.


Assuntos
COVID-19 , Neurocirurgia , Procedimentos Cirúrgicos Robóticos , Robótica , Humanos , SARS-CoV-2
10.
Stroke ; 42(1): 107-11, 2011 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-21071722

RESUMO

BACKGROUND AND PURPOSE: whether stenting is superior to angioplasty in the treatment of intracranial atherosclerotic disease is unknown. Dissections, vessel rupture, and lesion recoil observed with primary angioplasty using balloon catheters designed for coronary arteries have undermined the role of primary angioplasty as a preferred treatment for intracranial atherosclerotic disease. The goal of this study is to report the immediate and 3-month outcomes of treating patients with intracranial atherosclerotic disease with angioplasty balloon catheters in a multicenter study. METHODS: this is a retrospective review of 74 patients from 4 institutions treated with primary angioplasty for intracranial atherosclerotic disease over a 6-year time period. Technical success (residual stenosis ≤ 50%), periprocedural success (no vascular complication within 72 hours), and 3-month outcomes are reported. RESULTS: the mean degree of stenosis pretreatment was 79% ± 14% and reduced to 34% ± 18% after angioplasty. Technical success was achieved in 68 (92%; 95% CI, 83% to 97%) of the 74 patients. Periprocedural success was achieved in 65 (88%; 95% CI, 78% to 94%) of the 74 patients. There were 4 (5%; 95% CI, 1.5% to 13%) major procedure-related strokes, 2 of which resulted in death within 6 hours of the procedure. The 30-day stroke/death rate was 5% (4 of 74; CI, 1.5% to 13%). Three-month follow-up was available in 71 patients. In this interval, 2 patients had new stroke, 1 in the ipsilateral territory and the other in the contralateral territory. The 3-month stroke or death rate was 8.5% (6 of 71; CI, 3.1% to 17.5%); the retreatment rate was 2.8% (2 of 71; CI, 0.3% to 10%). CONCLUSIONS: balloon angioplasty is a relatively safe alternative treatment for intracranial atherosclerotic disease. Its role in the long-term secondary prevention of recurrent stroke as compared with intracranial stenting and medical therapy remains to be determined, preferably in a randomized study.


Assuntos
Angioplastia com Balão/efeitos adversos , Arteriosclerose Intracraniana/mortalidade , Arteriosclerose Intracraniana/terapia , Idoso , Angioplastia com Balão/métodos , Feminino , Seguimentos , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Retrospectivos , Acidente Vascular Cerebral/etiologia , Acidente Vascular Cerebral/mortalidade , Fatores de Tempo
11.
Med Phys ; 37(3): 1183-90, 2010 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-20384255

RESUMO

PURPOSE: Although the diffusion-weighted spin-echo single-shot echo-planar-imaging (DW-SE-sshEPI) is an established quantitative MRI (qMRI) pulse sequence, it is known to be vulnerable to geometric distortions. The purpose of this work is to study is to study brain volumetry accuracy with DW-SE-sshEPI relative previously published volumetry-validated qMRI pulse sequence, specifically the mixed turbo spin-echo (mixed-TSE) pulse sequence, which is robust to magnetic field inhomogeneities and affords much higher spatial resolution. METHODS: Twenty-eight subjects were imaged with both DW-SE-sshEPI and mixed-TSE pulse sequences. For each subject, the intracranial structures were segmented using a single-qMRI-channel dual-clustering algorithm (for DW-SE-sshEPI) and a three-qMRI-channel dual-clustering algorithm (for mixed-TSE). The respective intracranial volumes were calculated with both data sets and then compared. RESULTS: The intracranial volumes derived from DW-SE-sshEPI and mixed-TSE data sets are highly and linearly correlated (R2 = 0.9353) with a slope of 0.9911, with one distorted DW-SE-sshEPI data set demonstrating remarkable volume underestimation. Excluding this outlier resulted in improved linear correlation (R2 = 0.9681) with a slope of 1.0003. CONCLUSIONS: Brain volumetry with DW-SE-sshEPI at 1.5 T data sets can be very accurate for most patients for whom the major magnetic field inhomogeneities result from typical tissue interfaces (e.g., air-tissue or bone-tissue) and typical dental fillings, but not from larger metallic implants.


Assuntos
Algoritmos , Encefalopatias/patologia , Encéfalo/patologia , Imagem de Difusão por Ressonância Magnética/métodos , Imagem Ecoplanar/métodos , Aumento da Imagem/métodos , Interpretação de Imagem Assistida por Computador/métodos , Imageamento Tridimensional/métodos , Humanos , Reprodutibilidade dos Testes , Sensibilidade e Especificidade , Marcadores de Spin
12.
J Neurointerv Surg ; 12(5): 505-511, 2020 May.
Artigo em Inglês | MEDLINE | ID: mdl-31662464

RESUMO

BACKGROUND: Coil migration is a complication of endovascular coiling of cerebral aneurysms that has not been well studied. OBJECTIVE: To report the frequency, risk factors, management strategies, and outcomes of coil migration. METHODS: This was a retrospective analysis of the clinical and radiological data of patients who underwent cerebral aneurysm coiling complicated by coil migration at five neuroendovascular centers in the United States, Canada, and France between 2008 and 2018. RESULTS: Eighteen cases of coil migration met our study criteria with an occurrence of 0.3% (18/6071 cases) (procedural migration: 55%, delayed migration: 45%). The mean aneurysm maximal diameter, neck, and height to neck ratio in migration cases were 3.4±1.4 mm (range 2-7.6 mm), 2.4±0.9 mm (range 1.2-4.4 mm), and 1.4±0.4 (range 1-2.15), respectively. The 2 mm diameter coil was the most common (39%, range 1-2.5 mm) migrated coil. The length of the migrated coil was ≤4 cm in 95% of cases.Patients managed conservatively (5/18, 28%) did well. Thromboembolic and/or hemorrhagic complications were noted in 6/10 migration patients treated by endovascular modalities and in all migration patients who underwent surgical treatment (4/4). Three deaths occurred (3/18, 17%) related to high Hunt and Hess grade subarachnoid hemorrhage. CONCLUSION: Coil migration is an uncommon but important complication of cerebral aneurysm coiling. Small aneurysms, aspect ratio <1.6, and small coils are significant risk factors. Endovascular treatment, such as using a stent retriever, can be considered for procedural, proximal migration, and/or in cases of vessel occlusion. Delayed or distal migration should be managed conservatively.


Assuntos
Procedimentos Endovasculares/efeitos adversos , Procedimentos Endovasculares/instrumentação , Migração de Corpo Estranho/diagnóstico por imagem , Migração de Corpo Estranho/epidemiologia , Aneurisma Intracraniano/epidemiologia , Aneurisma Intracraniano/terapia , Adulto , Idoso , Canadá/epidemiologia , Angiografia Cerebral/métodos , Feminino , França/epidemiologia , Humanos , Aneurisma Intracraniano/diagnóstico por imagem , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos , Estudos Retrospectivos , Stents/efeitos adversos , Resultado do Tratamento , Estados Unidos/epidemiologia
13.
J Am Coll Radiol ; 17(9): 1086-1095, 2020 09.
Artigo em Inglês | MEDLINE | ID: mdl-32717183

RESUMO

OBJECTIVE: The coronavirus disease 2019 (COVID-19) pandemic resulted in significant loss of radiologic volume as a result of shelter-at-home mandates and delay of non-time-sensitive imaging studies to preserve capacity for the pandemic. We analyze the volume-related impact of the COVID-19 pandemic on six academic medical systems (AMSs), three in high COVID-19 surge (high-surge) and three in low COVID-19 surge (low-surge) regions, and a large national private practice coalition. We sought to assess adaptations, risks of actions, and lessons learned. METHODS: Percent change of 2020 volume per week was compared with the corresponding 2019 volume calculated for each of the 14 imaging modalities and overall total, outpatient, emergency, and inpatient studies in high-surge AMSs and low-surge AMSs and the practice coalition. RESULTS: Steep examination volume drops occurred during week 11, with slow recovery starting week 17. The lowest total AMS volume drop was 40% compared with the same period the previous year, and the largest was 70%. The greatest decreases were seen with screening mammography and dual-energy x-ray absorptiometry scans, and the smallest decreases were seen with PET/CT, x-ray, and interventional radiology. Inpatient volume was least impacted compared with outpatient or emergency imaging. CONCLUSION: Large percentage drops in volume were seen from weeks 11 through 17, were seen with screening studies, and were larger for the high-surge AMSs than for the low-surge AMSs. The lowest drops in volume were seen with modalities in which delays in imaging had greater perceived adverse consequences.


Assuntos
Infecções por Coronavirus/prevenção & controle , Diagnóstico por Imagem/estatística & dados numéricos , Controle de Infecções/organização & administração , Pandemias/prevenção & controle , Pneumonia Viral/prevenção & controle , Tomografia por Emissão de Pósitrons combinada à Tomografia Computadorizada/estatística & dados numéricos , Radiologia/estatística & dados numéricos , COVID-19 , Infecções por Coronavirus/epidemiologia , Diagnóstico por Imagem/métodos , Feminino , Previsões , Humanos , Incidência , Aprendizagem , Masculino , Pandemias/estatística & dados numéricos , Pneumonia Viral/epidemiologia , Radiologia/tendências , Medição de Risco , Estados Unidos
14.
Top Magn Reson Imaging ; 17(1): 19-30, 2006 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-17179894

RESUMO

OBJECTIVES: To review published magnetic resonance imaging (MRI) iron quantification techniques in the context of quantitative MRI and MR relaxation theories. To analyze comparatively and as a function of age the simultaneous measurements of the proton density (PD), the relaxation times (T1 and T2), and the longitudinal to transverse relaxation times ratio (T1/T2) of brain regions known to accumulate iron preferentially. METHODS: Twenty-seven human subjects were scanned with the mixed turbo spin echo pulse sequence, which is multispectral in PD, T1, and T2. Quantitative MRI (Q-MRI) maps of PD, T1, T2, and T1/T2 were generated, and region of interest measurements were performed in 5 brain regions, namely, frontal white matter (WM), genu of corpus callosum, caudate nucleus, putamen, and globus pallidus. RESULTS: Relaxation time measurements are consistent with results of others and provide further confirmation to our basic understanding of the relaxation effects of iron stores in the brain. Specifically, we found that the iron-rich globus pallidus exhibits enhanced T1 and T2 relaxation relative the iron poorer gray matter tissues (caudate nucleus and putamen) and also relative to the WM matter tissues (frontal WM and genu of the corpus callosum). We also observe that under riding this hypothesis-because we do not have independent confirmation-that iron caused relaxation enhancement, are the normal brain aging patterns, which suggest that the brain tissues become wetter with increasing age. Also noted is the virtual removal of age dependence observed for the T1/T2 ratio of WM tissues, further suggesting that this ratio may become of clinical significance in the diagnosis of neoplastic processes as well as for quantifying iron in tissue. CONCLUSIONS: The theoretical underpinnings of published brain iron Q-MRI techniques have been reviewed. We also examined MR relaxation theory essentials in relation to H-proton relaxation phenomena in diamagnetic tissues as well as theoretical extensions to describe relaxation effects in tissues containing iron deposits with a focus on ferritin. Also reported are in vivo Q-MRI results of 27 human brains obtained with a multispectral technique that uses the mixed turbo spin echo pulse sequence and a model conforming Q-MRI algorithms.


Assuntos
Encéfalo/metabolismo , Interpretação de Imagem Assistida por Computador/métodos , Ferro/análise , Ferro/metabolismo , Imageamento por Ressonância Magnética/métodos , Espectroscopia de Ressonância Magnética/métodos , Modelos Neurológicos , Simulação por Computador , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Distribuição Tecidual
15.
Interv Neurol ; 4(3-4): 75-82, 2016 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-27051402

RESUMO

Mechanical thrombectomy using retrievable stents or stent retriever devices has become the mainstay of intra-arterial therapy for acute ischemic stroke. The recent publication of a series of positive trials supporting intra-arterial therapy as standard of care for the treatment of large vessel occlusion will likely further increase stent retriever use. Rarely, premature stent detachment during thrombectomy may be encountered. In our multicenter case series, we found a rate of detachment of less than 1% (n = 7/1,067), and all were first-generation Solitaire FR devices. A review of the US Food and Drug Administration database of device experience yielded 90 individual adverse reports of detachment. There were 82, 1 and 7 detachments of Solitaire FR (first generation), Solitaire FR2 (second generation) and Trevo devices, respectively. We conclude with a brief overview of the technical and procedural considerations which may be helpful in avoiding this rare complication.

16.
Interv Neurol ; 4(1-2): 59-63, 2015 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-26600799

RESUMO

BACKGROUND: Very small ruptured aneurysms (≤3 mm) demonstrate a significant risk for procedural rupture with endovascular therapy. Since 2007, 1.5-mm-diameter coils have been available (Micrus, Microvention, and ev3), allowing neurointerventionalists the opportunity to offer patients with very small aneurysms endovascular treatment. In this study, we review the clinical and angiographic outcome of patients with very small ruptured aneurysms treated with the 1.5-mm coil. METHODS: This is a retrospective cohort study in which we examined consecutive ruptured very small aneurysms treated with coil embolization at a single institution. The longest linear aneurysm was recorded, even if the first coil was sized to a smaller transverse diameter. Very small aneurysms were defined as ≤3 mm. Descriptive results are presented. RESULTS: From July 2007 to March 2015, 81 aneurysms were treated acutely with coils in 78 patients presenting with subarachnoid hemorrhage. There were 5 patients with 3-mm aneurysms, of which the transverse diameter was ≤2 mm in 3 patients. In all 5 patients, a balloon was placed for hemostatic prophylaxis in case of rupture, and a single 1.5-mm coil was inserted for aneurysm treatment without complication. Complete aneurysm occlusion was achieved in 1 patient, residual neck in 2, and residual aneurysm in 2 patients. Aneurysm recanalization was present in 2 patients with an anterior communicating artery aneurysm; a recoiling attempt was unsuccessful in 1 of these 2 patients due to inadvertent displacement and distal coil embolization, but subsequent surgical clipping was successful. Another patient was retreated by surgical clipping for a residual wide-neck carotid terminus aneurysm. One patient died of ventriculitis 3 weeks after presentation; all 4 other patients had an excellent outcome with no rebleed at follow-up (mean 21 months, range 1-62). CONCLUSION: The advent of the 1.5-mm coil may be used in the endovascular treatment of patients with very small ruptured aneurysms, providing a temporary protection to the site of rupture in the acute phase. If necessary, bridging with elective clipping may provide definitive aneurysm treatment.

17.
Interv Neurol ; 4(1-2): 64-7, 2015 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-26600800

RESUMO

We present a rare case of bilateral posterior cerebral artery variant anatomy seen in a patient presenting with acute ischemic stroke. An embryological explanation of the variant configuration is discussed along with demonstrative radiologic images and a display of the vascular territory supplied.

18.
Hum Gene Ther ; 13(11): 1349-59, 2002 Jul 20.
Artigo em Inglês | MEDLINE | ID: mdl-12162817

RESUMO

tgAAVCF, an adeno-associated cystic fibrosis transmembrane conductance regulator (CFTR) viral vector/gene construct, was administered to 23 patients in a Phase II, double-blind, randomized, placebo-controlled clinical trial. For each patient, a dose of 100,000 replication units of tgAAVCF was administered to one maxillary sinus, while the contralateral maxillary sinus received a placebo treatment, thereby establishing an inpatient control. Neither the primary efficacy endpoint, defined as the rate of relapse of clinically defined, endoscopically diagnosed recurrent sinusitis, nor several secondary endpoints (sinus transepithelial potential difference [TEPD], histopathology, sinus fluid interleukin [IL]-8 measurements) achieved statistical significance when comparing treated to control sinuses within patients. One secondary endpoint, measurements of the anti-inflammatory cytokine IL-10 in sinus fluid, was significantly (p < 0.03) increased in the tgAAVCF-treated sinus relative to the placebo-treated sinus at day 90 after vector instillation. The tgAAVCF administration was well tolerated, without adverse respiratory events, and there was no evidence of enhanced inflammation in sinus histopathology or alterations in serum-neutralizing antibody titer to adeno-associated virus (AAV) capsid protein after vector administration. In summary, this Phase II trial confirms the safety of tgAAVCF but provides little support of its efficacy in the within-patient controlled sinus study. Various potentially confounding factors are discussed.


Assuntos
Regulador de Condutância Transmembrana em Fibrose Cística/genética , Fibrose Cística/terapia , Dependovirus/genética , Terapia Genética/métodos , Seio Maxilar , Administração Intranasal , Adolescente , Adulto , Fibrose Cística/diagnóstico , Fibrose Cística/imunologia , Método Duplo-Cego , Feminino , Técnicas de Transferência de Genes , Genes Virais , Vetores Genéticos/administração & dosagem , Vetores Genéticos/uso terapêutico , Humanos , Instilação de Medicamentos , Interleucina-10/análise , Masculino , Seio Maxilar/imunologia , Seio Maxilar/microbiologia , Sinusite Maxilar/genética , Sinusite Maxilar/cirurgia , Sinusite Maxilar/terapia , Líquido da Lavagem Nasal/citologia , Líquido da Lavagem Nasal/microbiologia , Prevenção Secundária , Fatores de Tempo
19.
AJNR Am J Neuroradiol ; 25(10): 1783-6, 2004.
Artigo em Inglês | MEDLINE | ID: mdl-15569746

RESUMO

Few reports of temporary disruption of the blood-brain barrier (BBB) following neurointerventional procedures, presumably caused by nonionic radiographic contrast medium (CM), exist in the literature. We described such a case in a 72-year-old man presenting with acute subarachnoid hemorrhage, who underwent coil embolization of a ruptured anterior communicating artery complex aneurysm. At the time of his follow-up CT examination, a large amount of iodine was found in the cerebrospinal fluid (CSF). Because of this experience, the iodine concentration in the CSF of five other patients who also underwent an intracranial endovascular procedure was measured. It was concluded that this increased iodine might have been caused by temporary leakage or breakdown of the BBB. Even if the total amount of CM may not be excessive, the disproportionately high concentration injected into a single vascular territory may pose a unique set of variables increasing the risk of BBB disruption.


Assuntos
Aneurisma Roto/terapia , Barreira Hematoencefálica/efeitos dos fármacos , Meios de Contraste/efeitos adversos , Embolização Terapêutica , Aneurisma Intracraniano/terapia , Idoso , Aneurisma Roto/líquido cefalorraquidiano , Aneurisma Roto/complicações , Embolização Terapêutica/instrumentação , Humanos , Aneurisma Intracraniano/líquido cefalorraquidiano , Aneurisma Intracraniano/complicações , Iodo/líquido cefalorraquidiano , Masculino , Hemorragia Subaracnóidea/diagnóstico por imagem , Hemorragia Subaracnóidea/etiologia , Tomografia Computadorizada por Raios X
20.
AJNR Am J Neuroradiol ; 25(6): 1058-61, 2004.
Artigo em Inglês | MEDLINE | ID: mdl-15205148

RESUMO

BACKGROUND AND PURPOSE: Although the selection of microcatheter for endovascular aneurysmal treatment is one important factor in patient outcome, the use of steam shaping for achieving safe entry and stability during coil placement has not, to our knowledge, been systematically evaluated. The goal of this study was to compare the durability of distal microcatheter steam shaping in five different catheters with typical intraprocedural stresses that are similar to those encountered during aneurysm coil placement. METHODS: Distal tips of microcatheters were shaped into a 90 degrees turn with distal straight-segment lengths of 3, 5, or 7 mm by using steam, performed according to the instructions for use included with each catheter. In a water bath kept at body temperature, the changes in catheter tip angle were recorded and measured following microcatheter insertion into a guiding catheter, microguidewire insertion through the microcatheter, and Guglielmi detachable coil (GDC) placement through the microcatheter. RESULTS: The degree of distal microcatheter straightening with typical intraprocedural manipulations was more pronounced on braided microcatheters and on microcatheters with 3- or 5-mm distal-shaped segments. The degree of spontaneous recovery of the initially steamed shape was more pronounced with nonbraided catheters. The most significant single variable contributing to straightening of a steam-shaped catheter tip was the effect of microguidewire insertion. The catheter-tip straightening effect encountered with inserting GDCs was less than that encountered with microguidewire insertion. We demonstrated that the decreased catheter-tip angle encountered with a large-magnitude straightening stress spontaneously recovered once the stress was removed or when it was reduced to a smaller magnitude stress. CONCLUSION: Our study shows that, although braided microcatheters are suitable for maintaining durable configurations when long distal-tip lengths are permissible, nonbraided microcatheters demonstrate the most durable distal-tip configurations when short distal-tip lengths are called for. This may be one of significant factors in catheter choice for endovascular treatment of aneurysm.


Assuntos
Cateterismo/instrumentação , Aneurisma Intracraniano/terapia , Desenho de Equipamento , Miniaturização , Estresse Mecânico
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA