RESUMO
We evaluated a novel scintigraphic method using new parameters of mechanical left ventricular (LV) dyssynchrony and correlated it with clinical outcomes in heart failure patients with reduced ejection fraction receiving cardiac resynchronization therapy (CRT). METHODS: Sixty-six advanced heart failure patients referred for CRT with an LV ejection fraction (EF) of < 35% and QRS ≥ 120 ms were studied. We performed equilibrium radionuclide angiography (ERNA) before and 6 mo after CRT. We assessed ventricular dyssynchrony with parameters derived from the first harmonic phase (Ø) analysis of the ERNA time-activity curve and evaluated change in these parameters after 6 mo of CRT. These parameters include novel indices of synchrony (S), a measure of intraventricular contraction order, and entropy (E), a measure of intraventricular contraction disorder, and interventricular synchrony (IVS), a measure of synchronous biventricular function. RESULTS: Forty-seven (71%) patients improved clinically (responders) at 6 mo after CRT whereas 19 (28.8%) showed no change in New York Heart Association class or worsened (nonresponders). The post-CRT changes in QRS duration (P = 0.006), echocardiographic (P = 0.03) and ERNA LVEF (P = 0.0007), LVS (P = 0.004), LVE (P = 0.006), LV standard deviation of ventricular phase (LVSDØ) (P = 0.004), and IVS (P = 0.05) were significantly different between responders and nonresponders. Sixty-two percent of responders had either an LVS < 0.84 or an IVS ≥ 18.8° as opposed to only 16% of nonresponders (P = 0.001). Twenty-nine of 32 (91%) patients with either of these measures responded to CRT (P < 0.01). CONCLUSION: LVS and IVS are novel measures of LV dyssynchrony derived from ERNA planar analysis. A baseline value of LVS < 0.84 or IVS ≥ 18.8° predicts a positive response to CRT.
Assuntos
Terapia de Ressincronização Cardíaca , Imagem do Acúmulo Cardíaco de Comporta , Insuficiência Cardíaca/diagnóstico por imagem , Insuficiência Cardíaca/terapia , Feminino , Insuficiência Cardíaca/fisiopatologia , Humanos , Masculino , Pessoa de Meia-Idade , Valor Preditivo dos Testes , Prognóstico , Volume Sistólico , Disfunção Ventricular Esquerda/diagnóstico por imagemRESUMO
BACKGROUND: Arrhythmogenic right ventricular cardiomyopathy (ARVC) is a heritable arrhythmia syndrome entailing a high risk of sudden cardiac death. Discernment from benign arrhythmia disorders, particularly right ventricular outflow tract ventricular tachycardia (RVOT VT), may be challenging, providing an impetus to explore alternative modalities that may facilitate evaluation of patients with suspected ARVC. OBJECTIVE: We evaluated the role of equilibrium radionuclide angiography (ERNA) as a diagnostic tool for ARVC. METHODS: ERNA measures of ventricular synchrony-synchrony (S) and entropy (E)-were examined in patients with ARVC (n = 16), those with RVOT VT (n = 13), and healthy controls (n = 49). The sensitivity and specificity of ERNA parameters for ARVC diagnosis were compared with those of echocardiography (ECHO) and cardiovascular magnetic resonance (CMR). RESULTS: ERNA right ventricular synchrony parameters in patients with ARVC (S = 0.91 ± 0.07; E = 0.61 ± 0.1) differed significantly from those in patients with RVOT VT (S = 0.99 ± 0.01 [P = .0015]; E = 0.46 ± 0.05 [P < .001]) and healthy controls (S = 0.97 ± 0.02 [P = .003]; E = 0.48 ± 0.07 [P = .001]). The sensitivity of ERNA synchrony parameters for ARVC diagnosis (81%) was higher than that for ECHO (38%; P = .033) and similar to that for CMR (69%; P = .162), while specificity was lower for ERNA (89%) than that for ECHO and CMR (both 100%; P = .008). CONCLUSION: ERNA right ventricular synchrony parameters can distinguish patients with ARVC from controls with structurally normal hearts, and its performance is comparable to that of ECHO and CMR for ARVC diagnosis. These findings suggest that ERNA may serve as a valuable imaging tool in the diagnostic evaluation of patients with suspected ARVC.