Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 26
Filtrar
Mais filtros

Base de dados
Tipo de documento
Intervalo de ano de publicação
1.
Phys Rev Lett ; 113(26): 260801, 2014 Dec 31.
Artigo em Inglês | MEDLINE | ID: mdl-25615296

RESUMO

The Stark shift due to blackbody radiation (BBR) is the key factor limiting the performance of many atomic frequency standards, with the BBR environment inside the clock apparatus being difficult to characterize at a high level of precision. Here we demonstrate an in-vacuum radiation shield that furnishes a uniform, well-characterized BBR environment for the atoms in an ytterbium optical lattice clock. Operated at room temperature, this shield enables specification of the BBR environment to a corresponding fractional clock uncertainty contribution of 5.5×10(-19). Combined with uncertainty in the atomic response, the total uncertainty of the BBR Stark shift is now 1×10(-18). Further operation of the shield at elevated temperatures enables a direct measure of the BBR shift temperature dependence and demonstrates consistency between our evaluated BBR environment and the expected atomic response.

2.
Phys Rev Lett ; 108(15): 153002, 2012 Apr 13.
Artigo em Inglês | MEDLINE | ID: mdl-22587248

RESUMO

Presently, the Stark effect contributes the largest source of uncertainty in a ytterbium optical atomic clock through blackbody radiation. By employing an ultracold, trapped atomic ensemble and high stability optical clock, we characterize the quadratic Stark effect with unprecedented precision. We report the ytterbium optical clock's sensitivity to electric fields (such as blackbody radiation) as the differential static polarizability of the ground and excited clock levels α(clock) = 36.2612(7) kHz (kV/cm)(-2). The clock's uncertainty due to room temperature blackbody radiation is reduced by an order of magnitude to 3×10(-17).

3.
Phys Rev Lett ; 107(10): 103902, 2011 Sep 02.
Artigo em Inglês | MEDLINE | ID: mdl-21981504

RESUMO

We study ultracold collisions in fermionic ytterbium by precisely measuring the energy shifts they impart on the atoms' internal clock states. Exploiting Fermi statistics, we uncover p-wave collisions, in both weakly and strongly interacting regimes. With the higher density afforded by two-dimensional lattice confinement, we demonstrate that strong interactions can lead to a novel suppression of this collision shift. In addition to reducing the systematic errors of lattice clocks, this work has application to quantum information and quantum simulation with alkaline-earth atoms.

4.
Science ; 293(5531): 825-8, 2001 Aug 03.
Artigo em Inglês | MEDLINE | ID: mdl-11452082

RESUMO

Microwave atomic clocks have been the de facto standards for precision time and frequency metrology over the past 50 years, finding widespread use in basic scientific studies, communications, and navigation. However, with its higher operating frequency, an atomic clock based on an optical transition can be much more stable. We demonstrate an all-optical atomic clock referenced to the 1.064-petahertz transition of a single trapped 199Hg+ ion. A clockwork based on a mode-locked femtosecond laser provides output pulses at a 1-gigahertz rate that are phase-coherently locked to the optical frequency. By comparison to a laser-cooled calcium optical standard, an upper limit for the fractional frequency instability of 7 x 10(-15) is measured in 1 second of averaging-a value substantially better than that of the world's best microwave atomic clocks.

5.
Science ; 341(6151): 1215-8, 2013 Sep 13.
Artigo em Inglês | MEDLINE | ID: mdl-23970562

RESUMO

Atomic clocks have been instrumental in science and technology, leading to innovations such as global positioning, advanced communications, and tests of fundamental constant variation. Timekeeping precision at 1 part in 10(18) enables new timing applications in relativistic geodesy, enhanced Earth- and space-based navigation and telescopy, and new tests of physics beyond the standard model. Here, we describe the development and operation of two optical lattice clocks, both using spin-polarized, ultracold atomic ytterbium. A measurement comparing these systems demonstrates an unprecedented atomic clock instability of 1.6 × 10(-18) after only 7 hours of averaging.

6.
Phys Rev Lett ; 103(6): 063001, 2009 Aug 07.
Artigo em Inglês | MEDLINE | ID: mdl-19792559

RESUMO

We experimentally investigate an optical clock based on ;{171}Yb (I = 1/2) atoms confined in an optical lattice. We have evaluated all known frequency shifts to the clock transition, including a density-dependent collision shift, with a fractional uncertainty of 3.4 x 10;{-16}, limited principally by uncertainty in the blackbody radiation Stark shift. We measured the absolute clock transition frequency relative to the NIST-F1 Cs fountain clock and find the frequency to be 518 295 836 590 865.2(0.7) Hz.

7.
Science ; 324(5925): 360-3, 2009 Apr 17.
Artigo em Inglês | MEDLINE | ID: mdl-19372424

RESUMO

At ultracold temperatures, the Pauli exclusion principle suppresses collisions between identical fermions. This has motivated the development of atomic clocks with fermionic isotopes. However, by probing an optical clock transition with thousands of lattice-confined, ultracold fermionic strontium atoms, we observed density-dependent collisional frequency shifts. These collision effects were measured systematically and are supported by a theoretical description attributing them to inhomogeneities in the probe excitation process that render the atoms distinguishable. This work also yields insights for zeroing the clock density shift.

8.
Phys Rev Lett ; 101(19): 193601, 2008 Nov 07.
Artigo em Inglês | MEDLINE | ID: mdl-19113267

RESUMO

We report a hitherto undiscovered frequency shift for forbidden J = 0-->J = 0 clock transitions excited in atoms confined to an optical lattice. These shifts result from magnetic-dipole and electric-quadrupole transitions, which have a spatial dependence in an optical lattice that differs from that of the stronger electric-dipole transitions. In combination with the residual translational motion of atoms in an optical lattice, this spatial mismatch leads to a frequency shift via differential energy level spacing in the lattice wells for ground state and excited state atoms. We estimate that this effect could lead to fractional frequency shifts as large as 10(-16), which might prevent lattice-based optical clocks from reaching their predicted performance levels. Moreover, these effects could shift the magic wavelength in lattice clocks in three dimensions by as much as 100 MHz, depending on the lattice configuration.

9.
Phys Rev Lett ; 100(10): 103002, 2008 Mar 14.
Artigo em Inglês | MEDLINE | ID: mdl-18352181

RESUMO

We present an experimental study of the lattice-induced light shifts on the (1)S(0) --> (3)P(0) optical clock transition (nu(clock) approximately 518 THz) in neutral ytterbium. The "magic" frequency nu(magic) for the 174Yb isotope was determined to be 394 799 475(35) MHz, which leads to a first order light shift uncertainty of 0.38 Hz. We also investigated the hyperpolarizability shifts due to the nearby 6s6p(3)P(0) --> 6s8p(3)P(0), 6s8p(3)P(2), and 6s5f(3)F(2) two-photon resonances at 759.708, 754.23, and 764.95 nm, respectively. By measuring the corresponding clock transition shifts near these two-photon resonances, the hyperpolarizability shift was estimated to be 170(33) mHz for a linear polarized, 50 microK deep, lattice at the magic wavelength. These results indicate that the differential polarizability and hyperpolarizability frequency shift uncertainties in a Yb lattice clock could be held to well below 10(-17).

10.
Science ; 319(5871): 1805-8, 2008 Mar 28.
Artigo em Inglês | MEDLINE | ID: mdl-18276849

RESUMO

Optical atomic clocks promise timekeeping at the highest precision and accuracy, owing to their high operating frequencies. Rigorous evaluations of these clocks require direct comparisons between them. We have realized a high-performance remote comparison of optical clocks over kilometer-scale urban distances, a key step for development, dissemination, and application of these optical standards. Through this remote comparison and a proper design of lattice-confined neutral atoms for clock operation, we evaluate the uncertainty of a strontium (Sr) optical lattice clock at the 1 x 10(-16) fractional level, surpassing the current best evaluations of cesium (Cs) primary standards. We also report on the observation of density-dependent effects in the spin-polarized fermionic sample and discuss the current limiting effect of blackbody radiation-induced frequency shifts.

11.
Phys Rev Lett ; 96(8): 083001, 2006 Mar 03.
Artigo em Inglês | MEDLINE | ID: mdl-16606175

RESUMO

We develop a method of spectroscopy that uses a weak static magnetic field to enable direct optical excitation of forbidden electric-dipole transitions that are otherwise prohibitively weak. The power of this scheme is demonstrated using the important application of optical atomic clocks based on neutral atoms confined to an optical lattice. The simple experimental implementation of this method--a single clock laser combined with a dc magnetic field--relaxes stringent requirements in current lattice-based clocks (e.g., magnetic field shielding and light polarization), and could therefore expedite the realization of the extraordinary performance level predicted for these clocks. We estimate that a clock using alkaline-earth-like atoms such as Yb could achieve a fractional frequency uncertainty of well below 10(-17) for the metrologically preferred even isotopes.

12.
Phys Rev Lett ; 96(8): 083002, 2006 Mar 03.
Artigo em Inglês | MEDLINE | ID: mdl-16606176

RESUMO

We report direct single-laser excitation of the strictly forbidden (6s2)1S0 <--> (6s6p)3P0 clock transition in 174Yb atoms confined to a 1D optical lattice. A small (approximately 1.2 mT) static magnetic field was used to induce a nonzero electric dipole transition probability between the clock states at 578.42 nm. Narrow resonance linewidths of 20 Hz (FWHM) with high contrast were observed, demonstrating a resonance quality factor of 2.6 x 10(13). The previously unknown ac Stark shift-canceling (magic) wavelength was determined to be 759.35 +/- 0.02 nm. This method for using the metrologically superior even isotope can be easily implemented in current Yb and Sr lattice clocks and can create new clock possibilities in other alkaline-earth-like atoms such as Mg and Ca.

13.
Phys Rev Lett ; 97(16): 163905, 2006 Oct 20.
Artigo em Inglês | MEDLINE | ID: mdl-17155398

RESUMO

We have performed sub-Doppler spectroscopy on the narrow intercombination line of cold calcium atoms using the amplified output of a femtosecond laser frequency comb. Injection locking of a 657-nm diode laser with a femtosecond comb allows for two regimes of amplification, one in which many lines of the comb are amplified, and one where a single line is predominantly amplified. The output of the laser in both regimes was used to perform kilohertz-level spectroscopy. This experiment demonstrates the potential for high-resolution absolute-frequency spectroscopy over the entire spectrum of the frequency comb output using a single high-finesse optical reference cavity.

14.
Phys Rev Lett ; 95(8): 083003, 2005 Aug 19.
Artigo em Inglês | MEDLINE | ID: mdl-16196856

RESUMO

We report the direct excitation of the highly forbidden (6s2) 1S0 <--> (6s6p) 3P0 optical transition in two odd isotopes of neutral ytterbium. As the excitation laser frequency is scanned, absorption is detected by monitoring the depletion from an atomic cloud at approximately 70 microK in a magneto-optical trap. The measured frequency in 171Yb (F=1/2) is 518,295,836,591.6 +/- 4.4 kHz. The measured frequency in 173Yb (F=5/2) is 518,294,576,847.6 +/- 4.4 kHz. Measurements are made with a femtosecond-laser frequency comb calibrated by the National Institute of Standards and Technology cesium fountain clock and represent nearly a 10(6)-fold reduction in uncertainty. The natural linewidth of these J=0 to J=0 transitions is calculated to be approximately 10 mHz, making them well suited to support a new generation of optical atomic clocks based on confinement in an optical lattice.

15.
Opt Lett ; 30(6): 667-9, 2005 Mar 15.
Artigo em Inglês | MEDLINE | ID: mdl-15792011

RESUMO

We use femtosecond laser frequency combs to convert optical frequency references to the microwave domain, where we demonstrate the synthesis of 10-GHz signals having a fractional frequency instability of < or =3.5 x 10(-15) at a 1-s averaging time, limited by the optical reference. The residual instability and phase noise of the femtosecond-laser-based frequency synthesizers are 6.5 x 10(-16) at 1 s and -98 dBc/Hz at a 1-Hz offset from the 10-GHz carrier, respectively. The timing jitter of the microwave signals is 3.3 fs.

16.
Opt Lett ; 30(8): 932-4, 2005 Apr 15.
Artigo em Inglês | MEDLINE | ID: mdl-15865403

RESUMO

A frequency comb is generated with a Cr:forsterite femtosecond laser, spectrally broadened through a highly nonlinear optical fiber to span from 1.0 to 2.2 ,m, and stabilized using the f-to-2f self-referencing technique. The repetition rate and the carrier-envelope offset frequency are stabilized to a hydrogen maser, calibrated by a cesium atomic fountain clock. Simultaneous frequency measurement of a 657-nm cw laser by use of the stabilized frequency combs from this Cr:forsterite system and a Ti:sapphire laser agree at the 10(-13) level. The frequency noise of the comb components is observed at 1064, 1314, and 1550 nm by comparing the measured beat frequencies between cw lasers and the supercontinuum frequency combs.

17.
Opt Lett ; 25(21): 1603-5, 2000 Nov 01.
Artigo em Inglês | MEDLINE | ID: mdl-18066290

RESUMO

For a neutral (40)Ca-based optical frequency standard we report a fractional frequency instability of 4 x 10(-15) in 1 s, which represents a fivefold improvement over existing atomic frequency standards. Using the technique of optical Bordé-Ramsey spectroscopy with a sample of 10(7) trapped atoms, we have resolved linewidths as narrow as 200 Hz (FWHM). With colder atoms this system could potentially achieve an instability as low as 2 x 10(-16) in 1 s. Such low instabilities are important for frequency standards and precision tests of fundamental physics.

18.
Opt Lett ; 29(10): 1081-3, 2004 May 15.
Artigo em Inglês | MEDLINE | ID: mdl-15181992

RESUMO

We demonstrate that femtosecond laser frequency combs (FLFCs) can have a subhertz linewidth across their entire emission spectra when they are phase locked to a reference laser with a similarly narrow linewidth. Correspondingly, the coherence time of the comb components relative to the reference laser can be of the order of a few seconds. Thus we are able to detect high-contrast spectral interferograms at up to 10-s integration time between two FLFCs locked to a common optical reference.

19.
Science ; 306(5700): 1318-24, 2004 Nov 19.
Artigo em Inglês | MEDLINE | ID: mdl-15550659

RESUMO

After 50 years of development, microwave atomic clocks based on cesium have achieved fractional uncertainties below 1 part in 10(15), a level unequaled in all of metrology. The past 5 years have seen the accelerated development of optical atomic clocks, which may enable even greater improvements in timekeeping. Time and frequency standards with various levels of performance are ubiquitous in our society, with applications in many technological fields as well as in the continued exploration of the frontiers of basic science. We review state-of-the-art atomic time and frequency standards and discuss some of their uses in science and technology.

20.
Opt Lett ; 26(2): 102-4, 2001 Jan 15.
Artigo em Inglês | MEDLINE | ID: mdl-18033520

RESUMO

With a fiber-broadened, femtosecond-laser frequency comb, the 76-THz interval between two laser-cooled optical frequency standards was measured with a statistical uncertainty of 2x10(-13) in 5 s , to our knowledge the best short-term instability thus far reported for an optical frequency measurement. One standard is based on the calcium intercombination line at 657 nm, and the other, on the mercury ion electric-quadrupole transition at 282 nm. By linking this measurement to the known Ca frequency, we report a new frequency value for the Hg(+) clock transition with an improvement in accuracy of ~10(5) compared with its best previous measurement.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA