1.
J Appl Clin Med Phys ; 24(8): e13992, 2023 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-37086445

RESUMO

The purpose of this study was to investigate the impact of scanning orientation and lateral response artifact (LRA) effects on the dose-response of EBT4 films and compare it with that of EBT3 films. Dose-response curves for EBT3 and EBT4 films in red-green-blue (RGB) color channels in portrait orientation were created for unexposed films and for films exposed to doses ranging from 0 to 1 000 cGy. Portrait and landscape orientations of the EBT3 and EBT4 films were scanned to investigate the scanning orientation effect in the red channel. EBT3 and EBT4 films were irradiated to assess the LRA in the red channel using a field size of 15 × 15 cm2 and delivered doses of 200, 400, and 600 cGy. Films were scanned at the edge of the scanner bed, and the measured doses were compared with the treatment planning system (TPS) calculated doses at a position 100 mm lateral to the scanner center. At a dose of 200 cGy, the differences in optical density (OD) in the red, green, and blue color channels between EBT3 and EBT4 films were 0.035 (24.8%), 0.042 (49.7%), and 0.022 (64.4%), respectively. The EBT4 film slightly improved the scanning orientation compared to the EBT3 film. The OD difference in the different scanning orientations for the EBT3 and EBT4 films was 0.015 (6.8%) and 0.007 (3.9%), respectively, at a dose of 200 cGy. This is equivalent to a 20 or 10 cGy variation at a dose of 200 cGy. Compared with the TPS calculation, the measurement doses for EBT3 and EBT4 films irradiated at 200 cGy were approximately 16% and 13% higher, respectively, at the 100 mm off-centered position. The EBT4 film showed an improvement concerning the impact of LRA compared with the EBT3 film. This study demonstrated that the response of EBT4 film to a dose in the blue channel was less sensitive and showed an improvement in the scanning orientation and LRA effects.


Assuntos
Artefatos , Dosimetria Fotográfica , Humanos , Calibragem
2.
J Appl Clin Med Phys ; 19(3): 360-366, 2018 May.
Artigo em Inglês | MEDLINE | ID: mdl-29667294

RESUMO

PURPOSE: Dual-source cone-beam computed tomography (DCBCT) is currently available in the Vero4DRT image-guided radiotherapy system. We evaluated the image quality and absorbed dose for DCBCT and compared the values with those for single-source CBCT (SCBCT). METHODS: Image uniformity, Hounsfield unit (HU) linearity, image contrast, and spatial resolution were evaluated using a Catphan phantom. The rotation angle for acquiring SCBCT and DCBCT images is 215° and 115°, respectively. The image uniformity was calculated using measurements obtained at the center and four peripheral positions. The HUs of seven materials inserted into the phantom were measured to evaluate HU linearity and image contrast. The Catphan phantom was scanned with a conventional CT scanner to measure the reference HU for each material. The spatial resolution was calculated using high-resolution pattern modules. Image quality was analyzed using ImageJ software ver. 1.49. The absorbed dose was measured using a 0.6-cm3 ionization chamber with a 16-cm-diameter cylindrical phantom, at the center and four peripheral positions of the phantom, and calculated using weighted cone-beam CT dose index (CBCTDIw ). RESULTS: Compared with that of SCBCT, the image uniformity of DCBCT was slightly reduced. A strong linear correlation existed between the measured HU for DCBCT and the reference HU, although the linear regression slope was different from that of the reference HU. DCBCT had poorer image contrast than did SCBCT, particularly with a high-contrast material. There was no significant difference between the spatial resolutions of SCBCT and DCBCT. The absorbed dose for DCBCT was higher than that for SCBCT, because in DCBCT, the two x-ray projections overlap between 45° and 70°. CONCLUSIONS: We found that the image quality was poorer and the absorbed dose was higher for DCBCT than for SCBCT in the Vero4DRT.


Assuntos
Tomografia Computadorizada de Feixe Cônico/instrumentação , Tomografia Computadorizada de Feixe Cônico/métodos , Imagens de Fantasmas , Garantia da Qualidade dos Cuidados de Saúde/normas , Interpretação de Imagem Radiográfica Assistida por Computador/métodos , Radioterapia Guiada por Imagem/métodos , Tomógrafos Computadorizados/normas , Algoritmos , Humanos , Processamento de Imagem Assistida por Computador/métodos , Doses de Radiação
3.
J Appl Clin Med Phys ; 17(6): 312-322, 2016 11 08.
Artigo em Inglês | MEDLINE | ID: mdl-27929504

RESUMO

Radiochromic films are important tools for assessing complex dose distributions. Gafchromic EBT-XD films have been designed for optimal performance in the 40-4,000 cGy dose range. We investigated the dosimetric characteristics of these films, including their dose-response, postexposure density growth, and dependence on scanner orientation, beam energy, and dose rate with applications to high-dose volumetric-modulated arc therapy (VMAT) verification. A 10 MV beam from a TrueBeam STx linear accelerator was used to irradiate the films with doses in the 0-4,000 cGy range. Postexposure coloration was analyzed at postirradiation times ranging from several minutes to 48 h. The films were also irradiated with 6 MV (dose rate (DR): 600 MU/min), 6 MV flattening filter-free (FFF) (DR: 1,400 MU/ min), and 10 MV FFF (DR: 2,400 MU/min) beams to determine the energy and dose-rate dependence. For clinical examinations, we compared the dose distribu-tion measured with EBT-XD films and calculated by the planning system for four VMAT cases. The red channel of the EBT-XD film exhibited a wider dynamic range than the green and blue channels. Scanner orientation yielded a variation of ~ 3% in the net optical density (OD). The difference between the film front and back scan orientations was negligible, with variation of ~ 1.3% in the net OD. The net OD increased sharply within the first 6 hrs after irradiation and gradually afterwards. No significant difference was observed for the beam energy and dose rate, with a variation of ~ 1.5% in the net OD. The gamma passing rates (at 3%, 3 mm) between the film- measured and treatment planning system (TPS)-calculated dose distributions under a high dose VMAT plan in the absolute dose mode were more than 98.9%.


Assuntos
Dosimetria Fotográfica/instrumentação , Dosimetria Fotográfica/métodos , Neoplasias/radioterapia , Planejamento da Radioterapia Assistida por Computador/métodos , Radioterapia de Intensidade Modulada/instrumentação , Calibragem , Humanos , Aceleradores de Partículas , Dosagem Radioterapêutica , Radioterapia de Intensidade Modulada/métodos