Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 5 de 5
Filtrar
1.
J Heart Lung Transplant ; 22(3): 322-33, 2003 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-12633700

RESUMO

BACKGROUND: Quality of life (QOL) outcomes after left ventricular assist device (LVAD) implantation from before to after hospital discharge have been examined only in a very small sample of patients. The purposes of this study are to describe change in QOL from before to after hospital discharge in LVAD patients and to determine whether being discharged with an LVAD predicts better QOL than being hospitalized with an LVAD. METHODS: A non-random sample of 62 LVAD patients (approximately 50 years old, male, white, married, fairly well-educated) completed self-report questionnaires at >or=2 timepoints post-implant. The questionnaires (Quality of Life Index, Rating Question Form, Heart Failure Symptom Checklist, Sickness Impact Profile, LVAD Stressor Scale, Jalowiec Coping Scale), which were collated into booklets, had acceptable reliability and validity. Longitudinal analyses were performed in 2 steps using 1-sample t-tests and linear mixed effects modeling. RESULTS: Perception of QOL and health status were fairly good both before and after discharge of LVAD patients. Discharge predicted increased satisfaction with socioeconomic areas of life; decreased overall and psychologic stress and stress related to family and friends, self-care and work/school/finances; and decreased physical and self-care disability. CONCLUSIONS: QOL outcomes improved from before to after hospital discharge in LVAD patients awaiting heart transplantation. As LVADs potentially become available as destination therapy, in addition to being successful bridges to heart transplantation, QOL outcomes will become more important to study.


Assuntos
Atitude Frente a Saúde , Coração Auxiliar/psicologia , Qualidade de Vida , Nível de Saúde , Humanos , Pacientes Internados/psicologia , Estudos Longitudinais , Masculino , Pessoa de Meia-Idade , Alta do Paciente , Estudos Prospectivos , Perfil de Impacto da Doença , Fatores Socioeconômicos , Estresse Psicológico/psicologia
2.
J Heart Lung Transplant ; 22(11): 1254-67, 2003 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-14585387

RESUMO

BACKGROUND: No studies have analyzed quality of life (QOL) from before to after heart transplantation in patients with a left ventricular assist device (LVAD). Therefore, the purpose of this longitudinal, multi-site study was to compare QOL outcomes of patients listed for heart transplantation who required a left ventricular assist device (LVAD) at 3 months after implantation of an LVAD vs 3 months after heart transplantation. METHODS: A non-random sample of 40 patients (predominantly middle-aged, married, white men), who had paired data at both 3 months after LVAD implantation and 3 months after heart transplantation, were investigated. Patients completed self-report questionnaires (with acceptable reliability and validity) at both time periods, including the Quality of Life Index, Rating Question Form, Heart Failure Symptom Checklist, Sickness Impact Profile, LVAD Stressor Scale (completed only after LVAD implant), Heart Transplant Stressor Scale (completed only after heart transplant) and Jalowiec Coping Scale. Descriptive analyses and comparative analyses using paired t-tests were performed with statistical significance set at 0.01. RESULTS: Patients were significantly more satisfied with their lives overall and with their health and functioning at 3 months after heart transplantation as compared with 3 months after LVAD implantation. Mobility, self-care ability, physical ability and overall functional ability improved from 3 months after LVAD implant to 3 months after heart transplant. There was significantly less symptom distress after LVAD implant as compared with after heart transplant for the neurologic, dermatologic and physical sub-scales. Work/school/financial stress was significantly lower after heart transplant vs after LVAD implant. In contrast, 2 other areas of stress were significantly lower after LVAD implant vs after heart transplant: self-care stress and hospital/clinic-related stress. CONCLUSIONS: Differences were found in QOL outcomes at 3 months after LVAD implant as compared with 3 months after heart transplant. Our findings point out specific areas of concern with respect to QOL after LVAD implant and post-transplant, some of which are amenable to health-care provider interventions.


Assuntos
Transplante de Coração/psicologia , Coração Auxiliar/psicologia , Qualidade de Vida , Adulto , Idoso , Austrália , Feminino , Seguimentos , Humanos , Masculino , Pessoa de Meia-Idade , Inquéritos e Questionários , Estados Unidos , Listas de Espera
3.
Ann Thorac Surg ; 75(5): 1624-6, 2003 May.
Artigo em Inglês | MEDLINE | ID: mdl-12735591

RESUMO

Left ventricular assist devices unload the left ventricle and decrease left atrial pressure. This hemodynamic change may cause a right to left atrial shunt and hypoxemia in patients with patent foramen ovale. We prospectively studied the best time for performing diagnostic transesophageal echocardiography in left ventricular assist device patients. Intraoperative transesophageal echocardiography was performed in 14 patients before cardiopulmonary bypass was initiated and after left ventricular assist device was implanted. No patent foramen ovale was detected when transesophageal echocardiography was done before bypass, but a patent foramen ovale was found in 3 patients when transesophageal echocardiography was performed after left ventricular assist device was activated. Patent foramen ovale was confirmed by inspection in all three patients and surgically closed during the same procedure. There were no patent foramen ovale closure-related complications.


Assuntos
Ecocardiografia Transesofagiana , Comunicação Interatrial/diagnóstico por imagem , Coração Auxiliar , Procedimentos Cirúrgicos Cardíacos , Comunicação Interatrial/cirurgia , Coração Auxiliar/efeitos adversos , Humanos , Período Intraoperatório , Estudos Prospectivos , Fatores de Tempo
4.
Ann Thorac Surg ; 77(4): 1321-7, 2004 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-15063260

RESUMO

BACKGROUND: The HeartMate vented electric left ventricular assist device has been approved for use as destination therapy. Thus, the study of quality-of-life outcomes, as well as morbidity and mortality, is imperative. The purpose of our study was to describe change with time (from 1 month to 1 year) in patients who received a HeartMate vented electric left ventricular assist device as a bridge to heart transplantation and to identify quality-of-life predictors of survival after left ventricular assist device implantation. METHODS: A nonrandom sample of 78 patients who received a HeartMate vented electric left ventricular assist device (primarily middle-aged, white married males) who had quality-of-life data at 1, 2, 3, 6, 9, or 12 months after implant was the subject of this report. The sample size decreased with time primarily because of heart transplantation. Patients completed the following booklets of questionnaires: Quality of Life Index, Rating Question Form, Heart Failure Symptom Checklist, and Sickness Impact Profile. Analyses included both descriptive analyses and modeling procedures (mixed-effects models and Cox proportional hazards models). RESULTS: Quality-of-life outcomes were fairly good and stable from 1 month to 1 year after HeartMate vented electric left ventricular assist device implantation. Both positive and negative changes were detected in all quality-of-life domains (physical and occupational function, social interaction, somatic sensation, and psychological state) after left ventricular assist device insertion. Items from the physical domain of quality of life, specifically walking and dressing oneself, were significantly associated with the risk of dying after left ventricular assist device implantation. CONCLUSIONS: Identifying poor quality-of-life outcomes within 1 year after left ventricular assist device implantation provides direction to develop strategies to improve outcomes. Physical and occupational rehabilitation, psychosocial intervention, and monitoring symptom distress and physical disability may contribute to improved quality-of-life outcomes and survival after left ventricular assist device implantation.


Assuntos
Coração Auxiliar , Qualidade de Vida , Adulto , Idoso , Feminino , Seguimentos , Insuficiência Cardíaca/mortalidade , Insuficiência Cardíaca/terapia , Transplante de Coração , Humanos , Masculino , Pessoa de Meia-Idade , Satisfação do Paciente , Próteses e Implantes , Inquéritos e Questionários , Taxa de Sobrevida
5.
Am J Crit Care ; 11(4): 345-52, 2002 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-12102435

RESUMO

OBJECTIVES: To describe quality-of-life outcomes; determine relationships between quality of life and demographic, physical, psychosocial, and clinical variables; and identify predictors of quality of life at 1 month after implantation of a left ventricular assist device. METHODS: Patients who received either an implantable pneumatic (n = 38) or a vented electric (n = 54) left ventricular assist device as a bridge to heart transplantation between August 1, 1994, and August 31, 1999, completed 6 instruments used to measure quality of life andfactors related to quality of life. Data were analyzed by using descriptive statistics, Pearson correlations, Mann-Whitney U tests, and forward, stepwise multiple regression. RESULTS: Overall satisfaction with quality of life was quite high as determined from the total score on the Quality of Life Index (mean = 0.69). Patients were very satisfied with the implantation and thought that they would do well after future heart transplant surgery. Patients had a moderate level of stress. Significant predictors of overall quality of life were psychological symptoms, stress, and race; these accounted for 46% of variance in quality of life. CONCLUSIONS: Patients were satisfied with their quality of life at 1 month after implantation of a left ventricular assist device. However, they were least satisfied with their health and functioning and yet were optimistic about how well they thought they would do after heart transplantation. Psychological factors were the strongest predictors of satisfaction with overall quality of life.


Assuntos
Insuficiência Cardíaca/cirurgia , Coração Auxiliar , Satisfação do Paciente/estatística & dados numéricos , Qualidade de Vida , Disfunção Ventricular Esquerda/cirurgia , Adaptação Psicológica , Adulto , Idoso , Austrália , Feminino , Insuficiência Cardíaca/psicologia , Humanos , Estudos Longitudinais , Masculino , Pessoa de Meia-Idade , Análise Multivariada , Estudos Prospectivos , Resultado do Tratamento , Estados Unidos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA