Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Mais filtros

Base de dados
Tipo de documento
Ano de publicação
Intervalo de ano de publicação
1.
Langenbecks Arch Surg ; 409(1): 21, 2023 Dec 28.
Artigo em Inglês | MEDLINE | ID: mdl-38151676

RESUMO

BACKGROUND: There is controversial evidence regarding the impact of clinically relevant postoperative intra-abdominal collections (CR-IC) on the clinical course after pancreaticoduodenectomy. C-reactive Protein (CRP) has been validated as a predictor of postoperative pancreatic fistula (POPF). Still, its role in predicting CR-IC has not been studied. METHODS: A retrospective analysis was conducted on patients who underwent PD at a tertiary hospital between October 2012 and October 2017. The incidence of CR-IC, clinically relevant POPF and other complications, as well as mortality and length of hospitalisation, was retrieved. The impact of CR-IR on mortality and major complications was analysed. The serum CRP levels were retrieved on the third and fifth postoperative days (POD3 and POD5), followed by an analysis of sensitivity, specificity, and area under the curve to predict CR-IC using CRP. RESULTS: One hundred forty patients were enrolled following inclusion and exclusion criteria. The mean age was 66.5 years (15-83). The incidence of CR-IC was 33.7% (47), and CR-POPF was 24.3%. Pancreatic duct diameter ≤ 4 mm was identified as a risk factor related to CR-IC occurrence. The group of patients who developed CR-IC after PD exhibited a higher rate of complications Clavien-Dindo ≥ III compared to patients without CR-IC (40.4% vs 7.5%, p < 0.001), as well as other events such as admission to the intensive care unit (25.5% vs 4.3%, p < 0.001), the incidence of CR-POPF (66% vs 3.2%, p < 0.001), prolonged hospital stay (32 vs 13 days, p < 0.001), postoperative haemorrhage (23.4 vs 5.4%, p = 0.002), and delayed gastric empty (38.8% vs 11.8%, p < 0.001) respectively. Logistic regression analysis identified CR-IC related to POPF as a risk factor for Clavien-Dindo > III: OR = 10.6 (95% CI: 3.90-28.7). No differences in mortality were reported between the CR-IC group and non-CR-IC group. CRP at postoperative day 3 (POD3) > 17.55 mg/dl and CRP at postoperative day 5 (POD5) > 13.46 mg/dl were predictors of CR-IC (AUC: 0.731 and AUC:0.821, respectively). CONCLUSIONS: CR-IC has a significant impact after pancreaticoduodenectomy and is associated with a higher incidence of Clavien-Dindo ≥ III complications. Additionally, CRP levels at POD3 and POD5 play a role in predicting CR-IC. Prospective studies are essential to explore strategies for mitigating the occurrence of CR-IC after PD.


Assuntos
Pâncreas , Pancreaticoduodenectomia , Humanos , Idoso , Pancreaticoduodenectomia/efeitos adversos , Estudos Retrospectivos , Estudos Prospectivos , Fístula Pancreática/epidemiologia , Fístula Pancreática/etiologia , Fatores de Risco , Proteína C-Reativa , Complicações Pós-Operatórias/epidemiologia , Complicações Pós-Operatórias/etiologia
2.
Dis Colon Rectum ; 64(6): 706-713, 2021 06 01.
Artigo em Inglês | MEDLINE | ID: mdl-33496487

RESUMO

BACKGROUND: External anal sphincter contractility significantly contributes to control the passage of stool. An artificial anal sphincter placed into the intersphincteric space is a safe and effective procedure to treat fecal incontinence, even if its mechanism of action has not been fully elucidated. OBJECTIVE: The aim of this study was to evaluate external anal sphincter contractility changes after a self-expandable hyexpan prostheses was implanted into the intersphincteric space of the anal canal and clinical outcomes compared. DESIGN: This was a prospective clinical study. SETTINGS: The study was conducted at a university teaching hospital. PATIENTS: Consecutive patients affected by fecal incontinence for at least 6 months after failure of conservative treatment were included. INTERVENTIONS: All of the patients underwent 10-prostheses implantation and were examined preoperatively and postoperatively by endoanal ultrasound and anorectal manometry. MAIN OUTCOME MEASURES: Fecal incontinence symptoms were assessed by severity scores. The external anal sphincter muscle tension was calculated using a specific equation. RESULTS: Thirty-nine patients (34 women; median age = 68 y) were included in the study; no morbidity was registered. After a median follow-up period of 14 months, both the median maximum voluntary squeeze pressure and the median inner radius of the external anal sphincter significantly increased. A statistically significant increase of external anal sphincter muscle tension was detected. A decrease of any fecal incontinence symptom and an improvement in severity scores were observed at the last follow-up examination. The external anal sphincter contractility was significantly higher in patients reducing incontinence episodes to solid stool by >50% and improving their ability to defer defecation for >15 minutes. LIMITATIONS: This was a single-center experience with a relatively small and heterogeneous sample size, patients with a potentially more severe disease because our institution is a referral center, and an absence of quality-of-life evaluation. CONCLUSIONS: Artificial anal sphincter implantation improved the external anal sphincter muscle tension; there was a positive correlation between its increase and the clinical outcome. See Video Abstract at http://links.lww.com/DCR/B468. IMPLANTE DE ESFNTER ANAL ARTIFICIAL AUTOEXPANDIBLE EN PACIENTES CON INCONTINENCIA FECAL MEJORA LA CONTRACTILIDAD DEL ESFNTER ANAL EXTERNO: ANTECEDENTES:La contractilidad del esfínter anal externo contribuye significativamente al control del paso de las heces. Un esfínter anal artificial colocado en el espacio interesfinteriano es un procedimiento seguro y eficaz para tratar la incontinencia fecal, incluso si su mecanismo de acción no se ha definido por completo.OBJETIVO:El objetivo de este estudio fue evaluar los cambios en la contractilidad del esfínter anal externo después de la implantación de una prótesis de hyexpan autoexpandible en el espacio interesfinteriano del canal anal y comparar los resultados clínicos.DISEÑO:Estudio clínico prospectivo.ENTORNO CLINICO:El estudio se realizó en un hospital universitario.PACIENTES:Pacientes consecutivos afectados por incontinencia fecal durante al menos 6 meses, tras fracaso de tratamiento conservador.INTERVENCIONES:Todos los pacientes fueron sometidos a la implantación de 10 prótesis, y fueron examinados pre y postoperatoriamente mediante ecografía endoanal y manometría anorrectal.PRINCIPALES MEDIDAS DE VALORACION:Los síntomas de incontinencia fecal se evaluaron mediante puntuaciones de gravedad. La tensión del músculo del esfínter anal externo se calculó mediante una formula específica.RESULTADOS:Treinta y nueve pacientes (34 mujeres; mediana de edad 68 años) fueron incluidos en el estudio; no se registró morbilidad. Después de un período de seguimiento medio de 14 meses, tanto la presión de compresión voluntaria máxima media como el radio interior medio del esfínter anal externo aumentaron significativamente. Se detectó un aumento estadísticamente significativo de la tensión del músculo del esfínter anal externo. En el último examen de seguimiento se observó una disminución de cualquier síntoma de incontinencia fecal y una mejora en las puntuaciones de gravedad. La contractilidad del esfínter anal externo fue significativamente mayor en los pacientes que redujeron los episodios de incontinencia a heces sólidas en más del 50% y mejoraron la capacidad para diferir la defecación durante más de 15 minutos.LIMITACIONES:Experiencia de un solo centro; tamaño de muestra relativamente pequeño y heterogéneo; pacientes con una enfermedad potencialmente más grave porque nuestra institución es un centro de referencia; ausencia de evaluación de la calidad de vida.CONCLUSIONES:La implantación del esfínter anal artificial mejoró la tensión muscular del esfínter anal externo; hubo una correlación positiva entre su aumento y el resultado clínico. Consulte Video Resumen en http://links.lww.com/DCR/B468.


Assuntos
Canal Anal/cirurgia , Incontinência Fecal/prevenção & controle , Tono Muscular/fisiologia , Próteses e Implantes/efeitos adversos , Implantação de Prótese/instrumentação , Idoso , Canal Anal/fisiopatologia , Defecação/fisiologia , Endossonografia/métodos , Incontinência Fecal/fisiopatologia , Feminino , Seguimentos , Humanos , Masculino , Manometria/métodos , Pessoa de Meia-Idade , Estudos Prospectivos , Desenho de Prótese/tendências , Implantação de Prótese/métodos , Segurança , Índice de Gravidade de Doença , Resultado do Tratamento
3.
Cancers (Basel) ; 15(20)2023 Oct 12.
Artigo em Inglês | MEDLINE | ID: mdl-37894322

RESUMO

Male urethral injury during rectal cancer surgery is rare but significant. Scant information is available about the distances between the rectourethral space and neighboring structures. The aim of this study is to describe the anatomical relations of the male urethra. This three-pronged study included cadaveric dissection, retrospective MRI analysis, and clinical cases. Measurements included the R-Mu distance (shortest distance between the rectum and the membranous urethra), R-Am distance (distance from the anterior rectal wall to anal margin nearest to the membranous urethra), and the anal canal-rectum axis angle. The clinical study analyzed the incidence of urethral injury and associated factors among 244 consecutive men from January 2016 to January 2023. The overall incidence of urethral injury in our series was low (0.73%), but in men with tumors < 10 cm from the anal margin, it was 4% in abdominoperineal resection and 3.2% in TaTME. On preoperative MRI, the median R-Mu distance was 1 cm (IQR, range, 0.2-2.3), the median R-Am distance was 4.3 cm (range, 2-7.3), and the median anorectal angle was 128° (range, 87-160). In the cadaveric study (nine adult male pelvises), the mean R-Mu distance was 1.18 cm (range 0.8-2), and the mean R-Am distance was 2.64 cm (range 2.1-3). Avoiding urethral injury is crucial. The critical point for injury lies 2-7.3 cm from the anal margin, with a 0.2-2.3 cm distance between the rectum and the membranous urethra. Collaborating with anatomists and radiologists improves surgeons' anatomy knowledge.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA