Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 41
Filtrar
1.
Thromb J ; 21(1): 104, 2023 Oct 04.
Artigo em Inglês | MEDLINE | ID: mdl-37794418

RESUMO

BACKGROUND: Fluorogenic thrombin generation (TG) is a global hemostasis assay that provides an overall representation of hemostasis potential. However, the accurate detection of thrombin activity in plasma may be affected by artifacts inherent to the assay-associated fluorogenic substrate. The significance of the fluorogenic artifacts or their corrections has not been studied in hemophilia treatment applications. METHODS: We sought to investigate TG in hemophilia plasma samples under typical and worst-case fluorogenic artifact conditions and assess the performance of artifact correction algorithms. Severe hemophilic plasma with or without added Factor VIII (FVIII) was evaluated using commercially available and in-house TG reagents, instruments, and software packages. The inner filter effect (IFE) was induced by spiking elevated amounts of fluorophore 7-amino-4-methylcoumarin (AMC) into plasma prior to the TG experiment. Substrate consumption was modeled by adding decreasing amounts of Z-Gly-Gly-Arg-AMC (ZGGR-AMC) to plasma or performing TG in antithrombin deficient plasma. RESULTS: All algorithms corrected the AMC-induced IFE and antithrombin-deficiency induced substrate consumption up to a certain level of either artifact (edge of failure) upon which TG results were not returned or overestimated. TG values in FVIII deficient (FVIII-DP) or supplemented plasma were affected similarly. Normalization of FVIII-DP resulted in a more accurate correction of substrate artifacts than algorithmic methods. CONCLUSIONS: Correction algorithms may be effective in situations of moderate fluorogenic substrate artifacts inherent to highly procoagulant samples, but correction may not be required under typical conditions for hemophilia treatment studies if TG parameters can be normalized to a reference plasma sample.

2.
Int J Mol Sci ; 24(16)2023 Aug 18.
Artigo em Inglês | MEDLINE | ID: mdl-37629101

RESUMO

Preclinical evaluation of drugs in animals helps researchers to select potentially informative clinical laboratory markers for human trials. To assess the utility of animal thrombin generation (TG) assay, we studied the sensitivity of animal plasmas to triggers of TG, human Tissue Factor (TF), and Activated Factor XI (FXIa). Pooled human, mouse, rat, guinea pig, rabbit, bovine, sheep, and goat plasmas were used in this study. TF- or FXIa-triggered TG and clotting were measured via fluorescence and optical density, respectively. Thrombin peak height (TPH) and time (TPT), clot time (CT), and fibrin clot density (FCD) were all analyzed. The trigger low and high sensitivity borders (LSB and HSB) for each assay parameter were defined as TF and FXIa concentrations, providing 20 and 80% of the maximal parameter value, unless the baseline (no trigger) value exceeded 20% of the maximal, in which case, LSB was derived from 120% of baseline value. Normal human samples demonstrated lower TPH HSB than most of the animal samples for both TF and FXIa. Animal samples, except mice, demonstrated lower TPT LSB for FXIa versus humans. Most rodent and rabbit samples produced baseline TG in the absence of TG triggers that were consistent with the pre-activation of blood coagulation. FCD was not sensitive to both TF and FXIa in either of the plasmas. Animal plasmas have widely variable sensitivities to human TF and FXIa, which suggests that optimization of trigger concentration is required prior to test use, and this complicates the extrapolation of animal model results to humans.


Assuntos
Fator XIa , Tromboplastina , Humanos , Animais , Bovinos , Camundongos , Ratos , Cobaias , Coelhos , Ovinos , Trombina , Plasma , Fibrina , Cabras
3.
Int J Mol Sci ; 23(15)2022 Jul 23.
Artigo em Inglês | MEDLINE | ID: mdl-35897712

RESUMO

Single-chain variable fragments (scFv) are antigen-recognizing variable fragments of antibodies (FV) where both subunits (VL and VH) are connected via an artificial linker. One particular scFv, iKM33, directed against blood coagulation factor VIII (FVIII) was shown to inhibit major FVIII functions and is useful in FVIII research. We aimed to investigate the properties of iKM33 enabled with protease-dependent disintegration. Three variants of iKM33 bearing thrombin cleavage sites within the linker were expressed using a baculovirus system and purified by two-step chromatography. All proteins retained strong binding to FVIII by surface plasmon resonance, and upon thrombin cleavage, dissociated into VL and VH as shown by size-exclusion chromatography. However, in FVIII activity and low-density lipoprotein receptor-related protein 1 binding assays, the thrombin-cleaved iKM33 variants were still inhibitory. In a pull-down assay using an FVIII-affinity sorbent, the isolated VH, a mixture of VL and VH, and intact iKM33 were carried over via FVIII analyzed by electrophoresis. We concluded that the isolated VL and VH assembled into scFv-like heterodimer on FVIII, and the isolated VH alone also bound FVIII. We discuss the potential use of both protease-cleavable scFvs and isolated Fv subunits retaining high affinity to the antigens in various practical applications such as therapeutics, diagnostics, and research.


Assuntos
Fator VIII , Anticorpos de Cadeia Única , Antígenos , Baculoviridae/metabolismo , Fator VIII/genética , Fator VIII/metabolismo , Proteína-1 Relacionada a Receptor de Lipoproteína de Baixa Densidade , Anticorpos de Cadeia Única/genética , Anticorpos de Cadeia Única/metabolismo , Trombina
4.
Biologicals ; 67: 88-93, 2020 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-32847723

RESUMO

In recent years, several modified recombinant factor (F) VIII and FIX therapeutics with extended half-life have been licensed internationally for the treatment of haemophilia. Safe and effective use of these products requires monitoring of factor activity in patient plasma. The potency of all FVIII and FIX products is currently assigned in International Units (IU) which anchors the relationship between potency labelling, dosing and clinical monitoring. However, varying degrees of discrepancies in factor activity assays are observed between and within the factor activity analytical methods (one-stage clotting and chromogenic), when measuring these modified products against plasma and plasma-derived (concentrate) International Standards (IS) or in-house reference standard traceable to the IS. Availability of product-specific reference reagents would mitigate assay discrepancies, facilitate independent testing of assay methods and reagents, and ensure long-term continuity of the IU related to each product. A hearing meeting was organised by the WHO to discuss the requirements for product-specific reference materials for these products and whether these reference materials should be produced by the WHO. Advantages and disadvantages of product-specific reference materials were identified and discussed.


Assuntos
Fator IX/normas , Fator VIII/normas , Proteínas Recombinantes/normas , Testes de Coagulação Sanguínea/métodos , Testes de Coagulação Sanguínea/normas , Técnicas de Laboratório Clínico/métodos , Técnicas de Laboratório Clínico/normas , Fator IX/genética , Fator IX/uso terapêutico , Fator VIII/genética , Fator VIII/uso terapêutico , Hemofilia A/tratamento farmacológico , Humanos , Proteínas Recombinantes/uso terapêutico , Padrões de Referência , Organização Mundial da Saúde
5.
Cell Mol Life Sci ; 75(20): 3781-3801, 2018 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-29427073

RESUMO

Platelet extracellular vesicles (PEVs) have emerged as potential mediators in intercellular communication. PEVs exhibit several activities with pathophysiological importance and may serve as diagnostic biomarkers. Here, imaging and analytical techniques were employed to unveil morphological pathways of the release, structure, composition, and surface properties of PEVs derived from human platelets (PLTs) activated with the thrombin receptor activating peptide (TRAP). Based on extensive electron microscopy analysis, we propose four morphological pathways for PEVs release from TRAP-activated PLTs: (1) plasma membrane budding, (2) extrusion of multivesicular α-granules and cytoplasmic vacuoles, (3) plasma membrane blistering and (4) "pearling" of PLT pseudopodia. The PLT extracellular vesiculome encompasses ectosomes, exosomes, free mitochondria, mitochondria-containing vesicles, "podiasomes" and PLT "ghosts". Interestingly, a flow cytometry showed a population of TOM20+LC3+ PEVs, likely products of platelet mitophagy. We found that lipidomic and proteomic profiles were different between the small PEV (S-PEVs; mean diameter 103 nm) and the large vesicle (L-PEVs; mean diameter 350 nm) fractions separated by differential centrifugation. In addition, the majority of PEVs released by activated PLTs was composed of S-PEVs which have markedly higher thrombin generation activity per unit of PEV surface area compared to L-PEVs, and contribute approximately 60% of the PLT vesiculome procoagulant potency.


Assuntos
Plaquetas/metabolismo , Micropartículas Derivadas de Células/metabolismo , Exossomos/metabolismo , Plaquetas/citologia , Membrana Celular/metabolismo , Quimiocinas/metabolismo , Citocinas/metabolismo , Humanos , Lipídeos/análise , Proteínas de Membrana Transportadoras/metabolismo , Microscopia Confocal , Microscopia Eletrônica de Transmissão , Proteínas Associadas aos Microtúbulos/metabolismo , Proteínas do Complexo de Importação de Proteína Precursora Mitocondrial , Mitofagia , Tamanho da Partícula , Fragmentos de Peptídeos/metabolismo , Proteômica , Receptores de Superfície Celular/metabolismo , Proteínas SNARE/metabolismo , Trombina/metabolismo
7.
Birth Defects Res C Embryo Today ; 105(3): 167-84, 2015 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-26406886

RESUMO

This review is focused on the epidemiology of venous thromboembolism (VTE), including deep vein thrombosis (DVT) and pulmonary embolism (PE), associated with pregnancy. Superficial vein thrombosis, a less hazardous and less studied type of thrombosis in pregnant women, is beyond the scope of this review. This study discusses the VTE incidence rate in women from developed countries for both antepartum and postpartum periods and for subpopulations of women affected by additional risk factors, such as thrombophilias, circulatory diseases, preeclampsia of varying degrees of severity, and Caesarean section. To minimize bias due to historical changes in medical and obstetric practices, lifestyle, diet, etc., this review is generally limited to relatively recent studies, i.e., those that cover the last 35 years. The absolute risk or incidence rate was used to ascertain risk of VTE associated with pregnancy. For the studies where the direct incidence rates of VTE were not reported, we calculated an estimate of the observed but not reported absolute incidence rates using the data presented in respective articles.


Assuntos
Complicações Hematológicas na Gravidez/epidemiologia , Tromboembolia Venosa/epidemiologia , Feminino , Humanos , Gravidez , Complicações na Gravidez , Fatores de Risco , Trombose Venosa/epidemiologia
8.
Biochemistry ; 54(2): 481-9, 2015 Jan 20.
Artigo em Inglês | MEDLINE | ID: mdl-25486042

RESUMO

Low-density lipoprotein receptor-related protein 1 (LRP) mediates clearance of blood coagulation factor VIII (FVIII). In LRP, FVIII binds the complement-type repeats (CRs) of clusters II and IV, which also bind a majority of other LRP ligands. No ligand is known for LRP cluster I, and only three ligands, including the LRP chaperone alpha-2 macroglobulin receptor-associated protein (RAP), bind cluster III. Using surface plasmon resonance, we found that in addition to clusters II and IV, activated FVIII (FVIIIa) binds cluster III. The specificity of this interaction was confirmed using an anti-FVIII antibody fragment, which inhibited the binding. Recombinant fragments of cluster III and its site-directed mutagenesis were used to localize the cluster's site for binding FVIIIa to CR.14-19. The interactive site of FVIIIa was localized within its A1/A3'-C1-C2 heterodimer (HDa), which is a major physiological remnant of FVIIIa. In mice, the clearance of HDa was faster than that of FVIII and prolonged in the presence of RAP, which is known to inhibit interactions of LRP with its ligands. In accordance with this, the cluster III site for RAP (CR.15-19) was found to overlap that for FVIIIa. Altogether, our findings support the involvement of LRP in FVIIIa catabolism and suggest a greater significance of the biological role of cluster III compared to that previously known.


Assuntos
Fator VIIIa/metabolismo , Proteína-1 Relacionada a Receptor de Lipoproteína de Baixa Densidade/metabolismo , Animais , Sítios de Ligação , Fator VIII/química , Fator VIII/metabolismo , Fator VIIIa/química , Proteína Associada a Proteínas Relacionadas a Receptor de LDL/metabolismo , Proteína-1 Relacionada a Receptor de Lipoproteína de Baixa Densidade/química , Camundongos , Camundongos Endogâmicos BALB C , Ligação Proteica , Mapeamento de Interação de Proteínas , Multimerização Proteica , Proteínas Recombinantes/química , Proteínas Recombinantes/metabolismo
9.
Blood ; 120(4): 891-9, 2012 Jul 26.
Artigo em Inglês | MEDLINE | ID: mdl-22563088

RESUMO

Recombinant factor VIIa (rFVIIa) is used for treatment of hemophilia patients with inhibitors, as well for off-label treatment of severe bleeding in trauma and surgery. Effective bleeding control requires supraphysiological doses of rFVIIa, posing both high expense and uncertain thrombotic risk. Two major competing theories offer different explanations for the supraphysiological rFVIIa dosing requirement: (1) the need to overcome competition between FVIIa and FVII zymogen for tissue factor (TF) binding, and (2) a high-dose-requiring phospholipid-related pathway of FVIIa action. In the present study, we found experimental conditions in which both mechanisms contribute simultaneously and independently to rFVIIa-driven thrombin generation in FVII-deficient human plasma. From mathematical simulations of our model of FX activation, which were confirmed by thrombin-generation experiments, we conclude that the action of rFVIIa at pharmacologic doses is dominated by the TF-dependent pathway with a minor contribution from a phospholipid-dependent mechanism. We established a dose-response curve for rFVIIa that is useful to explain dosing strategies. In the present study, we present a pathway to reconcile the 2 major mechanisms of rFVIIa action, a necessary step to understanding future dose optimization and evaluation of new rFVIIa analogs currently under development.


Assuntos
Coagulação Sanguínea/efeitos dos fármacos , Fator VIIa/farmacologia , Hemofilia A/tratamento farmacológico , Modelos Teóricos , Fosfolipídeos/farmacologia , Tromboplastina/farmacologia , Western Blotting , Precursores Enzimáticos , Humanos , Proteínas Recombinantes/sangue , Proteínas Recombinantes/farmacologia , Trombina/metabolismo
10.
Transfusion ; 54(10): 2553-65, 2014 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-24804899

RESUMO

BACKGROUND: Thrombotic events (TEs) are rare and serious adverse events after administration of immune globulin (IG) products. Our study evaluated the occurrence of same-day TEs for different IG products and ascertained potential risk factors. STUDY DESIGN AND METHODS: This retrospective cohort study utilized HealthCore's Integrated Research Database (HIRD) to assess individuals exposed to IGs during 2008 to 2012. IG products were identified using recorded procedure codes and TEs were ascertained using ICD-9-CM diagnosis codes. The unadjusted same-day TE rates (per 1000 persons exposed) were estimated overall and by IG products, age, and sex. Multivariable logistic regression analyses were used to estimate odds ratios (ORs) and 95% confidence intervals (CIs) for same-day TEs by IG products. RESULTS: Of 14,944 individuals exposed to IG products, 233 (15.6 per 1000 persons) had TE diagnosis code(s) recorded on the same-day as the IG exposure. Compared to Gammagard Liquid, Gammaplex (OR, 20.96; 95% CI, 2.45-179.33) and Vivaglobin (OR, 2.74; 95% CI, 1.19-6.32) users had a significantly increased same-day TE risk. Elevated, but nonsignificant TE risks were identified for Octagam, Gamunex, Privigen, and Lyophilized IG(s). An increased TE risk was also found with older age (≥45 years), prior TEs, and other health conditions. CONCLUSION: Our claims-based cohort study suggests a potentially elevated TE risk with different IG products and shows importance of recipient factors such as older age, previous TE, hypercoagulable state(s), and other health conditions. The results of this study suggest the need for continuous evaluation of procoagulant activity and manufacturing processes for IG products to further assure their safety.


Assuntos
Bases de Dados Factuais , Imunoglobulinas/sangue , Trombose/epidemiologia , Adulto , Idoso , Idoso de 80 Anos ou mais , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Sistema de Registros/estatística & dados numéricos , Estudos Retrospectivos , Fatores de Risco , Trombose/imunologia , Fatores de Tempo
11.
Thromb Res ; 233: 189-199, 2024 01.
Artigo em Inglês | MEDLINE | ID: mdl-38101192

RESUMO

INTRODUCTION: Growing evidence supports the importance of factor (F) XI activation for thrombosis and hemostasis as well as inflammation and complement systems. In this study, we evaluated the effect of activated FXI (FXIa) on the detection of factor deficiencies by global hemostasis assays of thrombin generation (TG), plasmin generation (PG), and clot formation and lysis (CFL). MATERIALS AND METHODS: An absorbance and fluorescence microplate assay was used to simultaneously observe TG, PG, and CFL in FV-, FVII-, FVIII-, and FIX-deficient plasmas supplemented with purified factors. Coagulation was initiated with tissue factor with or without FXIa in the presence of tissue plasminogen activator. Thrombin and plasmin peak heights (TPH and PPH), maximal clot density (MCD), times to clotting (CT), thrombin and plasmin peaks (TPT and PPT) and clot lysis (LyT) and a new parameter, clot lifetime (LiT), were evaluated. RESULTS: TG/CFL were elevated by the FXIa at low FV (below 0.1 IU/mL), and at FVIII and FIX above 0.01 IU/mL. FXIa affected PG only at low FV and FVII. At high factor concentrations, FXIa reduced MCD. Thrombin and plasmin substrates had effect on CT, LyT, LiT and MCD parameters. CONCLUSIONS: FXIa reveals new relationships between TG, PG and CFL parameters in factor deficiencies suggesting potential benefits for discrimination of bleeding phenotypes.


Assuntos
Trombina , Trombose , Humanos , Fator XIa , Fibrinolisina , Ativador de Plasminogênio Tecidual , Testes de Coagulação Sanguínea
12.
Nat Commun ; 15(1): 3912, 2024 May 09.
Artigo em Inglês | MEDLINE | ID: mdl-38724509

RESUMO

Direct oral anticoagulants (DOACs) targeting activated factor Xa (FXa) are used to prevent or treat thromboembolic disorders. DOACs reversibly bind to FXa and inhibit its enzymatic activity. However, DOAC treatment carries the risk of anticoagulant-associated bleeding. Currently, only one specific agent, andexanet alfa, is approved to reverse the anticoagulant effects of FXa-targeting DOACs (FXaDOACs) and control life-threatening bleeding. However, because of its mechanism of action, andexanet alfa requires a cumbersome dosing schedule, and its use is associated with the risk of thrombosis. Here, we present the computational design, engineering, and evaluation of FXa-variants that exhibit anticoagulation reversal activity in the presence of FXaDOACs. Our designs demonstrate low DOAC binding affinity, retain FXa-enzymatic activity and reduce the DOAC-associated bleeding by restoring hemostasis in mice treated with apixaban. Importantly, the FXaDOACs reversal agents we designed, unlike andexanet alfa, do not inhibit TFPI, and consequently, may have a safer thrombogenic profile.


Assuntos
Inibidores do Fator Xa , Hemorragia , Hemostasia , Pirazóis , Piridonas , Animais , Humanos , Masculino , Camundongos , Anticoagulantes/farmacologia , Anticoagulantes/efeitos adversos , Fator Xa/metabolismo , Inibidores do Fator Xa/farmacologia , Hemorragia/tratamento farmacológico , Hemorragia/induzido quimicamente , Hemostasia/efeitos dos fármacos , Pirazóis/farmacologia , Piridonas/farmacologia , Proteínas Recombinantes
13.
Sci Rep ; 14(1): 9225, 2024 04 22.
Artigo em Inglês | MEDLINE | ID: mdl-38649717

RESUMO

Thrombin generation (TG) and fibrin clot formation represent the central process of blood coagulation. Up to 95% of thrombin is considered to be generated after the clot is formed. However, this was not investigated in depth. In this study, we conducted a quantitative analysis of the Thrombin at Clot Time (TCT) parameter in 5758 simultaneously recorded TG and clot formation assays using frozen plasma samples from commercial sources under various conditions of activation. These samples were supplemented with clotting factor concentrates, procoagulant lipid vesicles and a fluorogenic substrate and triggered with tissue factor (TF). We found that TCT is often close to a 10% of thrombin peak height (TPH) yet it can be larger or smaller depending on whether the sample has low or high TPH value. In general, the samples with high TPH are associated with elevated TCT. TCT appeared more sensitive to some procoagulant phenotypes than other commonly used parameters such as clotting time, TPH or Thrombin Production Rate (TPR). In a minority of cases, TCT were not predicted from TG parameters. For example, elevated TCT (above 15% of TPH) was associated with either very low or very high TPR values. We conclude that clotting and TG assays may provide complementary information about the plasma sample, and that the TCT parameter may serve as an additional marker for the procoagulant potential in plasma sample.


Assuntos
Coagulação Sanguínea , Fibrina , Trombina , Trombina/metabolismo , Humanos , Fibrina/metabolismo , Testes de Coagulação Sanguínea/métodos , Tromboplastina/metabolismo , Tromboplastina/análise
14.
Protein Expr Purif ; 88(2): 201-6, 2013 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-23306063

RESUMO

A recombinant single-chain variable antibody fragment (scFv) KM33 was previously described as a ligand that can inhibit the function of blood coagulation factor VIII (FVIII). This scFv was previously derived from an individual with anti-FVIII antibodies manifested in FVIII functional deficiency (Hemophilia A) and expressed in bacteria. In the present work, we describe an alternative approach for fast and easy production of KM33 in insect cells (Spodoptera frugiperda). The KM33 gene was codon-optimized and expressed in secreted form using a baculovirus system. The protein was isolated using metal-affinity and size-exclusion chromatography to purity of about 96% and yield of 0.4-1.2 mg per 120 mL of culture, based on several independent expression experiments. In a binding assay using surface plasmon resonance, the insect cell-derived KM33 (iKM33) was qualified as a high-affinity ligand for FVIII. Epitope specificity of iKM33 on FVIII (C1 domain) was confirmed by testing the binding with a relevant mutant of FVIII. In several FVIII functional tests (factor Xa generation, APTT clotting, thrombin generation and video microscopy clot growth assays), iKM33 strongly inhibited FVIII activity in accordance with the clinical effect of the parental antibody. Therefore, the expressed protein was concluded to be fully functional and applicable in various assays with FVIII.


Assuntos
Fator VIII/imunologia , Anticorpos de Cadeia Única/genética , Anticorpos de Cadeia Única/imunologia , Animais , Baculoviridae/genética , Coagulação Sanguínea , Linhagem Celular , Fator VIII/antagonistas & inibidores , Fator VIII/metabolismo , Fator Xa/metabolismo , Expressão Gênica , Insetos/citologia , Insetos/genética , Plasmídeos/genética , Proteínas Recombinantes/genética , Proteínas Recombinantes/imunologia , Proteínas Recombinantes/isolamento & purificação , Anticorpos de Cadeia Única/isolamento & purificação , Trombina/metabolismo
15.
Am J Hematol ; 88(12): 1035-40, 2013 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-23907744

RESUMO

Thrombotic events (TEs) are rare serious complications following administration of hyperimmune globulin (HIG) products. Our retrospective claims-based study assessed occurrence of same-day TEs following administration of HIGs during 2008-2011 and examined potential risk factors using HealthCore's Integrated Research Database (HIRD(SM) ) and laboratory testing of products' procoagulant Factor XIa activity by U.S. Food and Drug Administration. Multivariable regression was used to estimate same-day TE risk for different products. Of 101,956 individuals exposed to 23 different HIG product groups, 86 (0.84 per 1,000 persons) had a TE diagnosis code (DC) recorded on the same day as HIG administration. Unadjusted same-day TE DC rates (per 1,000 persons) ranged from 0.4 to 148.9 for different products. GamaSTAN S/D IG >10 cc had statistically significantly higher same-day TE DC risk compared to Tetanus IG (OR = 57.57; 95% CI = 19.72-168.10). Increased TE risk was also observed with older age (≥45 years), prior thrombotic events, and hypercoagulable state(s). Laboratory investigation identified elevated Factor XIa activity for GamaSTAN S/D, HepaGam B, HyperHep B S/D, WinRho SDF, HyperRHO S/D full dose, and HyperTET S/D. Our study, for the first time, identified increase in the same-day TE DC risk with GamaSTAN S/D IG >10 cc and suggests potentially elevated TE risk with other HIGs.


Assuntos
Bases de Dados Factuais/estatística & dados numéricos , Embolia/etiologia , Imunoglobulinas/efeitos adversos , Trombose/etiologia , Adulto , Fatores Etários , Testes de Coagulação Sanguínea , Planos de Seguro Blue Cross Blue Shield/estatística & dados numéricos , Fatores de Confusão Epidemiológicos , Embolia/epidemiologia , Fator XIa/análise , Feminino , Humanos , Imunoglobulinas/química , Imunoglobulinas Intravenosas/efeitos adversos , Imunoglobulinas Intravenosas/química , Masculino , Recidiva , Estudos Retrospectivos , Fatores de Risco , Trombina/biossíntese , Trombofilia/complicações , Trombose/epidemiologia , Fatores de Tempo , Estados Unidos/epidemiologia
16.
Thromb J ; 11(1): 12, 2013 Jul 05.
Artigo em Inglês | MEDLINE | ID: mdl-23829491

RESUMO

BACKGROUND: Microplate-based thrombin generation test (TGT) is widely used as clinical measure of global hemostatic potential and it becomes a useful tool for control of drug potency and quality by drug manufactures. However, the convenience of the microtiter plate technology can be deceiving: microplate assays are prone to location-based variability in different parts of the microtiter plate. METHODS: In this report, we evaluated the well-to-well consistency of the TGT variant specifically applied to the quantitative detection of the thrombogenic substances in the immune globulin product. We also studied the utility of previously described microplate layout designs in the TGT experiment. RESULTS: Location of the sample on the microplate (location effect) contributes to the variability of TGT measurements. Use of manual pipetting techniques and applications of the TGT to the evaluation of procoagulant enzymatic substances are especially sensitive. The effects were not sensitive to temperature or choice of microplate reader. Smallest location effects were observed with automated dispenser-based calibrated thrombogram instrument. Even for an automated instrument, the use of calibration curve resulted in up to 30% bias in thrombogenic potency assignment. CONCLUSIONS: Use of symmetrical version of the strip-plot layout was demonstrated to help to minimize location artifacts even under the worst-case conditions. Strip-plot layouts are required for quantitative thrombin-generation based bioassays used in the biotechnological field.

17.
Blood Adv ; 7(11): 2622-2631, 2023 06 13.
Artigo em Inglês | MEDLINE | ID: mdl-36724509

RESUMO

Inhibitors of coagulation factor XIa (FXIa) are currently being investigated as potential anticoagulant therapies. We hypothesize that circulating FXIa could be a potential target for these therapies. Using previous analyses of FXIa impurities in immune globulin products involved in thrombotic adverse events, we estimated that picomolar levels of FXIa can be thrombogenic. In an in vitro clot-growth assay, 0.1-3 pM of FXIa did not, by itself, activate clotting but increased the size of growing clots. Spatio-temporal reconstruction of thrombin activity inside the clot revealed that FXIa's effect was limited to the clot-plasma interface, in which FXIa produced a taller than standard wave of thrombin. Factor-depleted plasma and a panel of selective anti-FXIa antibodies showed that exogenous FXIa effects are (1) blocked by anti-FXIa antibodies, (2) independent of FXI activation inside the clot, and (3) larger than the contribution of in situ FXIa. In a thrombin generation (TG) assay, picomolar FXIa did not initiate TG but rather promoted TG triggered by tissue factor or thrombin, suggesting that the effect of FXIa on the thrombin wave is mediated by the elevation of thrombin-triggered TG. In circulating bovine blood, low doses of human FXIa did not initiate clotting but increased the size of stenosis-triggered thrombi. FXIa injection in mice enhanced TG in plasma for at least 6 hours ex vivo, confirming the persistence of circulating FXIa. Our findings suggest that picomolar levels of circulating FXIa may not be able to initiate thrombosis but can facilitate thrombus growth through the facilitation of TG inside the clot.


Assuntos
Fator XIa , Trombose , Animais , Bovinos , Humanos , Camundongos , Trombina , Coagulação Sanguínea , Trombose/etiologia , Anticoagulantes
18.
Transfusion ; 52(10): 2113-21, 2012 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-22448967

RESUMO

BACKGROUND: Thrombotic events (TEs) are rare but often serious adverse events that could occur after administration of immune globulin (IG) products. Our study objective was to assess occurrence of recorded TEs after administration of different US-licensed IG products and investigate potential risk factors using a large administrative database. STUDY DESIGN AND METHODS: This is a retrospective claims-based cohort study of individuals exposed to IG products from January 1, 2008, through September 30, 2010, using HealthCore's Integrated Research Database, a longitudinal health care database. IG products were identified by recorded Healthcare Common Procedure Coding System codes. TEs were ascertained via International Classification of Diseases, Ninth Revision, Clinical Modification diagnosis codes. Logistic regression was used to estimate odds ratios (ORs) and 95% confidence intervals (CIs) for same-day TEs by IG product, while controlling for confounders. RESULTS: Of 11,785 individuals exposed to IG products in the study period, 122 (1%) had TE(s) recorded on the same day as IG administration. TE rates per 1000 persons exposed ranged from 6.1 to 20.5 for different IG product groups. Vivaglobin users had an increased same-day TE risk compared to reference Gammagard Liquid users (OR, 3.56; 95% CI, 1.54-8.23). An increased TE risk was also found with older age (≥ 45 years), prior TE(s), and hypercoagulable state(s). CONCLUSION: The study suggests potentially elevated TE rates for different IG products, including subcutaneous. It also identifies important recipient TE risk factors and suggests that risk-benefit profiles should be weighed before IG administration. The observed differences may be due to various factors such as dosage, administration rates, and product manufacturing processes that warrant further evaluation.


Assuntos
Imunoglobulinas Intravenosas/efeitos adversos , Trombose/etiologia , Adolescente , Adulto , Fatores Etários , Idoso , Planos de Seguro Blue Cross Blue Shield/estatística & dados numéricos , Criança , Comorbidade , Bases de Dados Factuais/estatística & dados numéricos , Suscetibilidade a Doenças , Relação Dose-Resposta Imunológica , Feminino , Humanos , Hiperlipidemias/epidemiologia , Hipertensão/epidemiologia , Inflamação/epidemiologia , Classificação Internacional de Doenças , Masculino , Pessoa de Meia-Idade , Obesidade/epidemiologia , Estudos Retrospectivos , Fatores de Risco , Trombofilia/epidemiologia , Trombose/epidemiologia , Estados Unidos/epidemiologia , Adulto Jovem
20.
Blood Adv ; 6(13): 3932-3944, 2022 07 12.
Artigo em Inglês | MEDLINE | ID: mdl-35413099

RESUMO

Hemophilia B is a blood clotting disorder caused by deficient activity of coagulation factor IX (FIX). Multiple recombinant FIX proteins are currently approved to treat hemophilia B, and several gene therapy products are currently being developed. Codon optimization is a frequently used technique in the pharmaceutical industry to improve recombinant protein expression by recoding a coding sequence using multiple synonymous codon substitutions. The underlying assumption of this gene recoding is that synonymous substitutions do not alter protein characteristics because the primary sequence of the protein remains unchanged. However, a critical body of evidence shows that synonymous variants can affect cotranslational folding and protein function. Gene recoding could potentially alter the structure, function, and in vivo immunogenicity of recoded therapeutic proteins. Here, we evaluated multiple recoded variants of F9 designed to further explore the effects of codon usage bias on protein properties. The detailed evaluation of these constructs showed altered conformations, and assessment of translation kinetics by ribosome profiling revealed differences in local translation kinetics. Assessment of wild-type and recoded constructs using a major histocompatibility complex (MHC)-associated peptide proteomics assay showed distinct presentation of FIX-derived peptides bound to MHC class II molecules, suggesting that despite identical amino acid sequence, recoded proteins could exhibit different immunogenicity risks. Posttranslational modification analysis indicated that overexpression from gene recoding results in suboptimal posttranslational processing. Overall, our results highlight potential functional and immunogenicity concerns associated with gene-recoded F9 products. These findings have general applicability and implications for other gene-recoded recombinant proteins.


Assuntos
Hemofilia B , Códon , Fator IX/genética , Fator IX/metabolismo , Hemofilia B/genética , Hemofilia B/terapia , Humanos , Proteínas Recombinantes/genética , Mutação Silenciosa
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA