Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 15 de 15
Filtrar
1.
J Vasc Surg ; 80(2): 405-412, 2024 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-38485069

RESUMO

OBJECTIVE: This study aimed to report the long-term outcomes beyond 10 years of endovascular aneurysm repair (EVAR) for abdominal aortic aneurysms using the low-profile INCRAFT device. METHODS: This was a single-center, retrospective cohort study of all patients undergoing EVAR using the INCRAFT device as part of the regulatory trial between 2012 and 2013. Primary endpoint was aneurysm-related death. Secondary endpoints were all-cause death, reintervention, late open conversion, and aneurysm status (shrinkage, stable, and growth). RESULTS: Thirty patients with a mean age of 71.8 ± 7.7 years were included in this study. The median aneurysm diameter at EVAR was 54.5 mm (interquartile range, 53-56.8 mm). All abdominal aortic aneurysms in this study were treated following the device's instructions for use. At index EVAR, the INCRAFT device was successfully implanted in all patients using a percutaneous approach under local anesthesia. No patients experienced major adverse events or procedure-related complications 30 days after EVAR. During the median follow-up of 125 months (interquartile range, 98-131 months) with follow-up rates of 100% at 5 years and 96.7% at 10 years, aneurysm-related mortality was 0%, and freedom from all-cause mortality was 82.9% at 5 years and 75.3% at 10 years. Reintervention was required in 10 patients with 15 procedures. Sac growth was observed in 11 patients (36.7%), six of whom eventually required late open conversion; five of these patients underwent open aneurysmorrhaphy with stent graft preservation, and one underwent open surgical repair with endograft explantation. Late rupture was identified in one case, where type Ia endoleak led to rupture at 69 months, and open repair was successfully performed. Freedom from reintervention was 89.0% at 5 years but declined to 60.9% at 10 years; freedom from late open conversion was 100% at 5 years but declined to 70.8% at 10 years. CONCLUSIONS: Long-term outcomes of the INCRAFT stent graft showed no aneurysm-related deaths. However, sac growth occurred persistently throughout the follow-up period, resulting in a relatively high rate of reinterventions in the later periods, which highlights the importance of lifelong postoperative surveillance and appropriate reinterventions when indicated.


Assuntos
Aneurisma da Aorta Abdominal , Implante de Prótese Vascular , Prótese Vascular , Procedimentos Endovasculares , Desenho de Prótese , Stents , Humanos , Aneurisma da Aorta Abdominal/cirurgia , Aneurisma da Aorta Abdominal/mortalidade , Aneurisma da Aorta Abdominal/diagnóstico por imagem , Estudos Retrospectivos , Idoso , Masculino , Procedimentos Endovasculares/instrumentação , Procedimentos Endovasculares/efeitos adversos , Procedimentos Endovasculares/mortalidade , Feminino , Fatores de Tempo , Implante de Prótese Vascular/efeitos adversos , Implante de Prótese Vascular/instrumentação , Implante de Prótese Vascular/mortalidade , Resultado do Tratamento , Complicações Pós-Operatórias/etiologia , Complicações Pós-Operatórias/mortalidade , Complicações Pós-Operatórias/cirurgia , Fatores de Risco , Pessoa de Meia-Idade , Idoso de 80 Anos ou mais , Reoperação
2.
J Vasc Surg ; 80(2): 397-404, 2024 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-38631517

RESUMO

OBJECTIVE: The aim of this study was to evaluate the initial and midterm outcomes of endovascular aneurysm repair (EVAR) for abdominal aortic aneurysm (AAA) using the cuff-first technique (CFT) to prevent type II endoleak (T2EL). METHODS: CFT involves deploying an aortic cuff inside the AAA to cover the ostium of the aortic side branch vessels before deploying the main body. We performed a retrospective review of all patients undergoing EVAR with CFT or side branch embolization (SBE) for AAAs at The Jikei University Hospital between 2016 and 2022. Primary endpoint was the rate of aneurysm sac shrinkage. Secondary endpoints were procedure time, radiation exposure, technical and clinical success rates, occurrence of T2EL, and freedom from reintervention or aneurysm-related death. RESULTS: Of 406 patients who underwent EVAR for AAAs, CFT was utilized in 56 (CFT group) and SBE in 35 (SBE group); all 91 patients were included in this study. There were no differences in patient demographics between groups, but there were differences in patency rate of the inferior mesenteric artery and absent intraluminal thrombus. The technical success rate per target vessel in the CFT and SBE group was 97.8% and 91.8%, and the clinical success rate was 91.0% and 100%, respectively. The median procedure time was shorter for CFT than for SBE: CFT, 10 (interquartile range [IQR], 6-14) minutes vs SBE, 25 (IQR, 18.5-45) minutes; P < .05), and median radiation exposure was lower for CFT than for SBE (CFT, 1455 (IQR, 840-2634) mGy vs SBE, 2353 (IQR, 1552-3586) mGy; P < .05). During the median follow-up of 25 months (IQR, 12.5-47 months), sac shrinkage occurred at similar rates in both groups (CFT, 37.5% vs SBE, 40.0%; P = .812), and there were no differences in freedom from reintervention (CFT, 96.2% and 91.4% at 12 and 36 months vs SBE, 100% and 89.5% at 12 and 36 months; log-rank P = .761) and freedom from aneurysm-related death (100% at 36 months in both groups; log-rank P = .440). The odds ratio of CFT vs SBE for sac regression was calculated by adjusting for inferior mesenteric artery patency and absent intraluminal thrombus, resulting in no statistical significance (odds ratio, 1.231; 95% confidence interval, 0.486-3.122). CONCLUSIONS: CFT is feasible with a shorter procedure time and lower radiation exposure than SBE and comparable mid-term outcomes, including sac shrinkage rate, compared with SBE. We believe that CFT, if anatomically suitable, is an alternative to SBE for the prevention of T2EL during EVAR.


Assuntos
Aneurisma da Aorta Abdominal , Implante de Prótese Vascular , Endoleak , Procedimentos Endovasculares , Humanos , Aneurisma da Aorta Abdominal/cirurgia , Aneurisma da Aorta Abdominal/diagnóstico por imagem , Estudos Retrospectivos , Endoleak/etiologia , Endoleak/prevenção & controle , Masculino , Feminino , Procedimentos Endovasculares/efeitos adversos , Procedimentos Endovasculares/instrumentação , Idoso , Implante de Prótese Vascular/efeitos adversos , Implante de Prótese Vascular/instrumentação , Fatores de Tempo , Idoso de 80 Anos ou mais , Resultado do Tratamento , Fatores de Risco , Prótese Vascular , Embolização Terapêutica/efeitos adversos , Duração da Cirurgia
3.
J Vasc Surg ; 2024 May 13.
Artigo em Inglês | MEDLINE | ID: mdl-38750942

RESUMO

OBJECTIVE: Prevention of late type Ia endoleaks is the main concern in thoracic endovascular aortic aneurysm repair (TEVAR) for thoracic aortic aneurysm. Since 2017, we have performed zone 0 TEVAR with proximal fixation augmentation using a Najuta thoracic fenestrated stent graft in addition to zone 2 TEVAR for distal arch aneurysms. We report the early and midterm outcomes of TEVAR performed using this strategy. METHODS: This single-center retrospective study enrolled 386 cases of TEVAR for thoracic aortic disease between January 2013 and December 2020. Patients with thoracic aortic aneurysm treated by TEVAR landing at zone 2 was referred to as the standard group, whereas those treated by TEVAR landing at zone 0 using a Najuta fenestrated stent graft in addition to zone 2 TEVAR was referred to as the augmentation group. We retrospectively compared the clinical outcomes between the two groups. The primary end point was secondary intervention for postoperative type Ia endoleaks. Secondary end points were technical success, aneurysm-related death, and major adverse events (MAEs), including stroke, paraplegia, endoleaks, and secondary interventions. RESULTS: We performed TEVAR in 41 and 30 cases in the standard and augmentation groups, respectively. The mean aneurysm sizes in the standard and augmentation groups were 54.5 and 57.3 mm (P = .23), and the proximal neck lengths were 16.8 and 17.4 mm (P = .65), respectively. The anatomical characteristics seemed to be similar in both groups. The technical success rate in both groups was 100%. Three cases in the standard group had MAEs, including two stroke and one brachial artery pseudoaneurysm; whereas two cases had MAEs in the augmentation group, including one stroke and one paraplegia. There was no 30-day mortality or retrograde type A dissection in both groups. The mean observation periods in the standard and augmentation groups were 46 months (range, 1-123 months) and 35 months (range, 1-73 months), respectively. At 36 and 60 months after the procedure, the freedom from aneurysm-related death was 97.6% and 97.6% in the standard group, 100.0% and 100.0% in the augmentation group (P = .39); and the freedom from reintervention for type Ia endoleaks was 79.2% and 65.2% in the standard group, 100.0% and 100.0% in the augmentation group (P = .0087). A statistically significant decrease in reinterventions for type Ia endoleaks was observed in the augmentation group. CONCLUSIONS: Proximal fixation augmentation using the Najuta fenestrated stent graft during TEVAR for distal arch aneurysm is effective in preventing the postoperative late type Ia endoleaks.

4.
J Vasc Surg ; 77(3): 760-768, 2023 03.
Artigo em Inglês | MEDLINE | ID: mdl-36306936

RESUMO

OBJECTIVE: We evaluated the perioperative and mid-term clinical outcomes of open aneurysmorrhaphy (OA) for the treatment of sac expansion after endovascular aneurysm repair (EVAR) of abdominal aortic aneurysms. METHODS: OA involves sac exposure without dissection of the proximal or distal neck, sacotomy and ligation of back-bleeding vessels, preservation of the prior stent graft, and tight closure of the sac around the stent graft. We performed a retrospective review of all patients who had undergone OA for nonruptured sac expansion after standard EVAR at our institution between January 2015 and June 2021. The primary end points were 30-day mortality and aneurysm-related death. The secondary end points were postoperative complications, overall survival, freedom from reintervention, and sac regrowth rate. RESULTS: A total of 28 patients had undergone OA. Their mean age was 76.9 ± 6.7 years. The median sac diameter at OA was 79 mm (interquartile range [IQR], 76-92 mm). The median duration from the index EVAR to OA was 82 months (IQR, 72-104 months). Preoperative computed tomography angiography confirmed a type II endoleak (EL) in 20 patients, 1 of whom had had a coexisting type Ia EL; a type IIIb EL was identified in 1 patient. Concomitant endovascular procedures had been performed in six patients to treat a type I or III EL or reinforce the proximal and distal seals. The OA technique has been modified since 2017, with the addition of more aggressive dissection of the sac and complete removal of the mural thrombus to further decrease the sac diameter. Postoperative complications occurred in two patients and included abdominal lymphorrhea and failed hemostasis of the common femoral artery requiring surgical repair in one patient each. The 30-day mortality was 0%. During the median follow-up of 36 months (IQR, 14-51 months), the overall survival was 92.7% and 86.9% at 12 and 36 months, respectively, without any aneurysm-related death. In the late (2017-2021) treatment group, the median sac diameter immediately after OA was smaller than that in the early (2015-2016) treatment group (early group: median, 50 mm; IQR, 39-57 mm; vs later group: median, 41 mm; IQR, 32-47 mm; P = .083). Furthermore, in the late group, the sac regrowth rate was lower (early group: median, 0.36 mm/mo; IQR, 0.23-0.83 mm/mo; vs late group: median, 0 mm/mo; IQR, 0-0.11 mm/mo; P = .0075) and the freedom from reintervention rate was higher (late group: 94.7% at both 12 and 36 months, respectively; early group: 71.4% and 53.6% at 12 and 36 months, respectively; log-rank P = .070). CONCLUSIONS: Our results have shown that OA for the management of post-EVAR sac expansion is feasible with acceptable mid-term outcomes. Aggressive dissection and tight plication of the sac might be imperative for better mid-term outcomes after OA.


Assuntos
Aneurisma da Aorta Abdominal , Implante de Prótese Vascular , Procedimentos Endovasculares , Humanos , Idoso , Idoso de 80 Anos ou mais , Aneurisma da Aorta Abdominal/cirurgia , Implante de Prótese Vascular/efeitos adversos , Resultado do Tratamento , Procedimentos Endovasculares/efeitos adversos , Complicações Pós-Operatórias , Endoleak/etiologia , Estudos Retrospectivos , Fatores de Risco
5.
J Vasc Surg ; 75(3): 803-811.e2, 2022 03.
Artigo em Inglês | MEDLINE | ID: mdl-34742885

RESUMO

OBJECTIVE: To evaluate the early outcomes of retrograde in situ branched stent grafting (RIBS) using the gutter balloon technique for complex aortic arch aneurysms (CAAs). METHODS: The RIBS technique is an in situ needle fenestration procedure during thoracic endovascular aortic repair with the reconstruction of cervical branches. The double RIBS (D-RIBS) for the reconstruction of the left common carotid artery and the brachiocephalic artery using the gutter balloon technique was performed in 30 high-risk patients. We describe the early clinical results of the D-RIBS technique for CAAs. Primary end points were technical success and 30-day mortality. Secondary end points were postoperative complications, rates of endoleaks, overall survival, aneurysm-related death, and reinterventions. RESULTS: The mean age was 77.1 ± 6.6 years, and the mean maximum minor-axis aneurysmal diameter was 65.9 ± 8.9 mm. Twenty-six patients underwent D-RIBS for elective arch aortic aneurysm, and four patients were for reintervention after zone 2 thoracic endovascular aortic repair failure. Stent graft puncture was performed 60 times from the common carotid arteries, and technical success was achieved in all cases (100%). Postoperative complications included cerebral infarction in two patients (6.7%) and recurrent nerve palsy in one patient (3.3%). The 30-day mortality was 0%. During the median follow-up period of 14 months (6-56 months), overall survival at 12 months was 92.3% without any aneurysm-related death. Type 1 b and type 2 endoleaks were observed in one each, and no reintervention was encountered. CONCLUSIONS: Early clinical outcomes of the D-RIBS for high-risk patients with CAAs are acceptable. The gutter balloon method enables safe and reliable fenestration. Further studies and dedicated devices are warranted.


Assuntos
Aneurisma da Aorta Torácica/cirurgia , Implante de Prótese Vascular/instrumentação , Prótese Vascular , Procedimentos Endovasculares/instrumentação , Stents , Idoso , Idoso de 80 Anos ou mais , Aneurisma da Aorta Torácica/diagnóstico por imagem , Aneurisma da Aorta Torácica/mortalidade , Implante de Prótese Vascular/efeitos adversos , Implante de Prótese Vascular/mortalidade , Procedimentos Endovasculares/efeitos adversos , Procedimentos Endovasculares/mortalidade , Feminino , Humanos , Masculino , Complicações Pós-Operatórias/etiologia , Desenho de Prótese , Estudos Retrospectivos , Fatores de Risco , Fatores de Tempo , Resultado do Tratamento
6.
J Vasc Surg ; 67(2): 490-497, 2018 02.
Artigo em Inglês | MEDLINE | ID: mdl-28943006

RESUMO

OBJECTIVE: We developed a mini-incision eversion carotid endarterectomy (CEA) procedure (the Jikei method CEA) to prevent perioperative embolic stroke. The aim of this study was to retrospectively analyze perioperative and midterm outcomes after the Jikei method CEA. METHODS: We evaluated patients with the Jikei method CEA at our institution between January 2006 and June 2014. The primary end point was a major adverse event, which included death, stroke, intracranial hemorrhage, and myocardial infarction, within 30 days of CEA. Secondary end points were postoperative ipsilateral stroke and restenosis. RESULTS: We retrospectively studied 120 lesions in 110 patients. The mean age was 72.2 ± 8.0 years. With regard to the 120 lesions, 56 lesions (46.7%) were symptomatic and 73 lesions (60.8%) showed ≥90% severe stenosis. The mean length of the skin incision was 3.2 ± 0.5 cm. The mean operative time, volume of blood loss, and internal carotid artery clamp time were 171.0 ± 50.7 minutes, 161.6 ± 110.8 mL, and 35.7 ± 10.8 minutes, respectively. There were three perioperative major adverse events (2.5%), including two strokes (1.7%) and one intracranial hemorrhage (0.8%) resulting from hyperperfusion syndrome. The median postoperative hospital stay was 6 days (range, 2-303 days). The mean follow-up was 3.9 ± 2.2 years. There was no case of ipsilateral stroke during the follow-up period. The freedom from ipsilateral stroke at 5 years was 98.3%. Three lesions (2.5%) developed restenosis. The freedom from restenosis was 97.2% at 5 years. The freedom from reintervention at 5 years was 99.0% because carotid artery stent placement was necessary in one patient with severe restenosis. CONCLUSIONS: The Jikei method CEA was safe and effective in preventing perioperative and midterm stroke.


Assuntos
Artéria Carótida Interna/cirurgia , Estenose das Carótidas/cirurgia , Endarterectomia das Carótidas/métodos , Idoso , Idoso de 80 Anos ou mais , Angiografia , Artéria Carótida Interna/diagnóstico por imagem , Estenose das Carótidas/complicações , Estenose das Carótidas/diagnóstico por imagem , Estenose das Carótidas/mortalidade , Intervalo Livre de Doença , Endarterectomia das Carótidas/efeitos adversos , Endarterectomia das Carótidas/mortalidade , Feminino , Humanos , Embolia Intracraniana/etiologia , Embolia Intracraniana/prevenção & controle , Hemorragias Intracranianas/etiologia , Estimativa de Kaplan-Meier , Tempo de Internação , Masculino , Pessoa de Meia-Idade , Recidiva , Estudos Retrospectivos , Fatores de Risco , Acidente Vascular Cerebral/etiologia , Acidente Vascular Cerebral/prevenção & controle , Fatores de Tempo , Tóquio , Resultado do Tratamento
7.
Ann Vasc Surg ; 39: 288.e5-288.e12, 2017 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-27671450

RESUMO

We report a case in which a stent graft and an Amplatzer® vascular plug (AVP) were effective for the treatment of chronic aneurysmal aortic dissection. The patient was a 52-year-old man. At 45 years of age, he developed acute aortic dissection, for which he underwent surgery 4 times with prosthetic graft replacement in the abdominal aorta, descending thoracic, ascending aorta (without neck branch reconstruction), and thoracoabdominal aorta with the reconstruction of the celiac, superior mesenteric, and bilateral renal arteries. At the time of thoracoabdominal aortic surgery, strong adhesion was evident, particularly in the thoracoabdominal area. The adhesion was dissected in a part of the chest, and prosthetic graft replacement was performed the following day. Subsequently, the dissection of the residual distal aortic arch enlarged, and the patient was examined at our hospital. Computed tomography (CT) revealed a small intimal tear at the site of anastomosis distal to the graft in the ascending aorta and a large intimal tear in the descending thoracic aorta with a maximum diameter of 67 mm. Furthermore, open repair by prosthetic graft replacement seemed difficult; therefore, treatment with stent grafting was considered. Because the prosthetic graft in the abdomen was extremely tortuous, stent-graft insertion via the femoral artery seemed to be impossible. The planned treatment involved the placement of a thoracic stent graft using the chimney technique which included reconstruction of the brachiocephalic artery and left common carotid arteries using chimney stent graft and coverage of the left subclavian artery. The thoracic stent graft was planned to be inserted via the abdominal prosthetic graft site because the abdominal prosthetic graft was crooked and was located close to the body surface. However, a small intimal tear distal to the graft in the ascending aorta which had not been revealed by intraoperative aortography was detected by the selective angiography, and closure with an AVP was attempted for this. The site was successfully closed using an AVP with a wire passing through the tear and into the false lumen. Thereafter, the large tear in the descending thoracic aorta was closed using a stent graft. The patient made good postoperative progress without evidence of paraplegia, and complete thrombosis of the false lumen was confirmed by postoperative CT. CT at 1 year after thoracic endovascular aneurysm repair (TEVAR) showed complete thrombosis of false lumen and aneurysm shrinkage.


Assuntos
Aneurisma da Aorta Abdominal/cirurgia , Aneurisma da Aorta Torácica/cirurgia , Dissecção Aórtica/cirurgia , Implante de Prótese Vascular/instrumentação , Prótese Vascular , Procedimentos Endovasculares/instrumentação , Stents , Dissecção Aórtica/diagnóstico por imagem , Aneurisma da Aorta Abdominal/diagnóstico por imagem , Aneurisma da Aorta Torácica/diagnóstico por imagem , Aortografia/métodos , Doença Crônica , Angiografia por Tomografia Computadorizada , Remoção de Dispositivo , Humanos , Masculino , Pessoa de Meia-Idade , Desenho de Prótese , Reoperação , Resultado do Tratamento
8.
J Am Heart Assoc ; 13(11): e032715, 2024 Jun 04.
Artigo em Inglês | MEDLINE | ID: mdl-38780177

RESUMO

BACKGROUND: Saccular abdominal aortic aneurysms (AAAs) are considered to be at higher risk of rupture than fusiform AAAs, but not much is known about the extent of this risk. Therefore, this study aimed to compare the rupture presentation between fusiform and saccular AAAs. METHODS AND RESULTS: This is a retrospective cohort study on 27 290 patients who underwent primary endovascular repair for a degenerative AAA between 2016 and 2019, and who were registered in the National Clinical Database in Japan. At operation for nonruptured case, the aneurysm diameter was significantly smaller in saccular AAAs than in fusiform AAAs (median, 44.0 versus 51.0 mm; P<0.001). Similarly, aneurysm diameter at rupture was significantly smaller in saccular AAAs than in fusiform AAAs (median, 55.6 versus 68.0 mm; P<0.001). The likelihood of repair for rupture was significantly higher in saccular AAAs than in fusiform AAAs in the 40- to 54-mm diameter range, in which saccular morphology was found to be an independent risk factor for rupture against fusiform morphology by adjusting for sex and aneurysm diameter (odds ratio, 2.54 [95% CI, 1.75-3.69]). In addition, receiver-operating characteristic curve analysis revealed that the cutoff diameter to predict rupture was smaller in saccular AAAs than in fusiform AAAs (50.5 and 59.5 mm, respectively) based on the Youden index. CONCLUSIONS: Saccular AAAs presented at smaller diameters than fusiform AAAs in patients with ruptured AAAs treated with endovascular aortic repair, which supports the idea that saccular AAAs should be treated at smaller diameters.


Assuntos
Aneurisma da Aorta Abdominal , Ruptura Aórtica , Bases de Dados Factuais , Procedimentos Endovasculares , Humanos , Aneurisma da Aorta Abdominal/cirurgia , Aneurisma da Aorta Abdominal/diagnóstico por imagem , Procedimentos Endovasculares/métodos , Procedimentos Endovasculares/efeitos adversos , Feminino , Masculino , Japão/epidemiologia , Estudos Retrospectivos , Idoso , Ruptura Aórtica/cirurgia , Ruptura Aórtica/diagnóstico por imagem , Fatores de Risco , Idoso de 80 Anos ou mais , Implante de Prótese Vascular , Resultado do Tratamento , Medição de Risco , Pessoa de Meia-Idade
9.
J Vasc Surg Cases Innov Tech ; 10(5): 101493, 2024 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-39069991

RESUMO

A 4-year-old girl presented with complaints of transient speech disorder and left-sided weakness. Magnetic resonance imaging revealed multiple strokes, computed tomography showed a right axillary artery aneurysm of 40 mm, and an angiogram indicated retrograde embolism. She underwent aneurysm resection and reconstruction with a saphenous vein graft. Two years after surgery, a mass lesion occurred in the native artery on the proximal side of the prior surgical anastomosis. Surgical resection and reconstruction were performed. An isolated 1-mm diameter lesion was found in the retrospectively reviewed completion angiogram from the initial surgery, which was the origin of the subsequent progressive lesion. The pathological examination, including after the initial surgery, revealed a myopericytoma.

10.
J Vasc Surg Cases Innov Tech ; 9(4): 101112, 2023 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-38106353

RESUMO

Several options exist for the treatment of celiac artery (CA) aneurysms (CAAs), including surgical repair and endovascular procedures. However, treatment of CAAs can be challenging owing to their proximity to the ostium of the CA and involvement of the CA branches. In the present report, we have described a case of a giant CAA extending from the proximal CA to the hepatosplenic bifurcation. Owing to the anatomic complexity of this CAA, proximal control was a major therapeutic concern. The patient underwent open aneurysmectomy using the retrograde balloon occlusion technique to control the inflow of the CAA, with a satisfactory result.

11.
Ann Vasc Dis ; 15(1): 22-28, 2022 Mar 25.
Artigo em Inglês | MEDLINE | ID: mdl-35432654

RESUMO

Objective: Ultrasound-guided thrombin injection (UGTI) is an option for the treatment of postcatheterization pseudoaneurysms. This method is less invasive and less time-consuming compared with other procedures since it can be performed without general anesthesia, skin incision, or occlusion of the artery. Herein, we report on the efficacy of UGTI for postcatheterization bleeding complications. Methods: Postcatheterization bleeding complications include postcatheterization pseudoaneurysm and failed hemostasis. In this study, failed hemostasis was defined as cases in which hemostasis could not be accomplished by 30 min of manual compression following sheath removal. A retrospective study of eight cases in which we performed UGTI for postcatheterization bleeding complications between July 2016 and June 2019 at our institution was performed to evaluate technical success and recurrence of pseudoaneurysm or rebleeding events. Results: Among these eight cases, there were three cases of pseudoaneurysm and five cases of failed hemostasis. In all cases, technical success was achieved without any complications such as distal embolism or allergic reaction. There were no recurrences of pseudoaneurysm or rebleeding events during an average follow-up of 5.25 months. Conclusion: We believe that UGTI is effective not only for postcatheterization pseudoaneurysms but also for failed hemostasis.

12.
J Vasc Surg Cases Innov Tech ; 8(1): 102-106, 2022 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-35146219

RESUMO

At present, no consensus has been reached regarding the optimal management of stent graft thrombosis in the femoropopliteal artery. We present a case of long thrombosis of a Viabahn stent graft implanted in the superficial femoral artery that was successfully treated by thrombectomy using a trans-Viabahn approach at the mid-thigh segment. The advantages of this approach include that it preserves the common femoral artery and popliteal artery untouched without scarring, allowing for a future site of surgical anastomosis. This technique could be a reasonable approach when performing surgical thrombectomy for stent graft thrombosis in the femoropopliteal artery.

13.
J Vasc Surg Cases Innov Tech ; 8(3): 313-318, 2022 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-35812121

RESUMO

Although retrograde in situ branched stent grafting (RIBS) is one possible treatment option for thoracic aortic aneurysms, concerns exist regarding the durability of the stent graft (SG) at the junction between the main SG and the branched SG. We report on the autopsy results of a patient treated with RIBS for a complex aortic arch aneurysm. The patient had died of a nonaortic cause 14 months after the RIBS procedure. On computed tomography analysis and a leak test, the harvested SG was intact without any stent fracture, stenosis, or junctional leak at 1 atm water pressure (760 mm Hg).

14.
Medicine (Baltimore) ; 95(46): e5430, 2016 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-27861387

RESUMO

BACKGROUND: Hereditary hemorrhagic telangiectasia (HHT) is characterized by mucocutaneous telangiectasia and visceral vascular malformations (VMs). Liver involvement with VMs may lead to high-output cardiac failure, portal hypertension, and biliary disease. There is no curative treatment for the disease, and liver transplantation is indicated for life-threatening complications. Herein, we report a case of multiple hepatic artery aneurysms (HAAs) in a patient with HHT in which open arterial reconstruction was performed. There have only been a few case reports on HAA occurring with HHT. Thus, this case provides important information for the management of HHT-associated HAAs. CASE SUMMARY: A 62-year-old female with known HHT was referred to our facility to seek further treatment for a giant HAA. She denied any symptoms except recurrent epistaxis. A computed tomography (CT) scan revealed a right HAA with a diameter of 72 mm, in addition to 2 other minor HAAs. The CT scan also revealed the VMs that were scattered in the liver, and a continuously dilated and tortuous artery existing from the celiac trunk to the right and left hepatic arteries. We performed open arterial reconstruction of the HAAs. Her postoperative course was uneventful. CONCLUSIONS: When treating HAAs, there are a variety of options. However, hepatic VMs might affect HHT patients in various ways postprocedurally. Ligation and embolization of the hepatic artery may lead to complications, such as massive hepatic necrosis. Hepatectomy should be avoided if possible, because a postoperative hyperperfusive state in the remaining liver can cause adverse events. We believe that arterial reconstruction of HHT-associated HAAs might reduce the risk of postprocedural complications with minimal hemodynamic changes in the liver, thus obviating the need for hepatectomy or liver transplantation.


Assuntos
Aneurisma , Angiografia/métodos , Artéria Hepática , Telangiectasia Hemorrágica Hereditária , Procedimentos Cirúrgicos Vasculares/métodos , Aneurisma/diagnóstico , Aneurisma/etiologia , Aneurisma/cirurgia , Feminino , Artéria Hepática/anormalidades , Artéria Hepática/diagnóstico por imagem , Artéria Hepática/cirurgia , Humanos , Fígado/irrigação sanguínea , Fígado/diagnóstico por imagem , Pessoa de Meia-Idade , Procedimentos de Cirurgia Plástica/métodos , Telangiectasia Hemorrágica Hereditária/complicações , Telangiectasia Hemorrágica Hereditária/fisiopatologia , Tomografia Computadorizada por Raios X/métodos , Resultado do Tratamento
15.
J Vasc Surg Cases Innov Tech ; 2(3): 63-65, 2016 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-38827213

RESUMO

Although eversion carotid endarterectomy (CEA) has gained popularity, there are some concerns, including difficulties in handling the distal intimal flap, especially in those patients with a high lesion. Therefore, intraoperative angiography is routinely performed during CEA to check for intimal flaps and to assess the need for adjunctive maneuvers such as stent placement. We describe our adjunctive intraoperative carotid artery stenting after eversion CEA for unsatisfactory distal internal carotid artery end points detected by routine completion angiography. By conducting completion angiography when in doubt and adjunctive carotid artery stenting if indicated, the potential disadvantage of eversion CEA can be minimized.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA